Special quality research about action output waveform change by gap (1.0mm and 1.6mm) difference of $CO_2$ laser for skin disease (피부질환을 위한 $CO_2$ 레이저의 공극 (1.0mm 및 1.6mm)차이에 따른 동작출력 파형변화에 관한 특성연구)

  • Kim, Whi-Young
    • Proceedings of the KIEE Conference
    • /
    • 2007.04c
    • /
    • pp.156-158
    • /
    • 2007
  • Laser wave length can have evaporation effect by absorption because outer skin or tissue of focus is consisted of water almost though absorption of water occurs more than 90% almost in formation thickness of very thin floor Can operate outer skin, steam by floor and correct incision of formation is available. Suture surgical operation is avaliable to vein or lymph system and surgical operation region can dry and see as eye and radish bleeding surgical operation is avaliable Specially, stability of tube both end output about pulse by weight very, this research can cause various curative effect because can reduce bulk and control easily current wave style of medical laser using electric power conversion device of high frequency way. If introduce ZVS (Zero Voltage Switching) or ZVZCS (Zero Voltage and Zero Current Switching), is more profitable because can reduce switching damage Because electric power department of proposed medical laser can do stable soft-switching in wide subordinate extent introducing ZVZCS technique by the first help and control department composes microcontroller, output current waveform user have free form make. Result that experiment because design and manufacture, brought result that improve of 20% than existing equipment, and will be bought to get into superior result if supplement as systematic late.

  • PDF

Design of Home&Mobile Healthcare System Based on Smart Phone PMG(personal mobile gateway) (스마트폰 PMG(personal mobile gateway) 기반의 홈&모바일 헬스케어 시스템 설계)

  • Jean, Jae-Hwan;Kim, Sung-Hyun;Gang, Seong-In;Kim, Kwan-Hyung;Oh, Am-Suk
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.05a
    • /
    • pp.757-759
    • /
    • 2011
  • 본 논문에서는 홈 헬스케어에서 건강측정을 위하여 가장 많이 사용되는 개인 건강 기기(personal health device)인 혈당계, 혈압계, 심박측정계(heart rate monitor), 산소포화도 측정계(pulse-oximeter), 심전도 측정계(ECG monitor)의 5가지 홈 헬스케어 의료기기를 구성하고 표준 핵심 기술 요소인 ISO/IEEE 11073, HL7을 준용하는 게이트웨이 플랫폼을 스마트폰에 적용하여 기존의 홈 헬스케어 시스템을 구성하는 단말기 형태의 게이트웨이나 홈 서버 하드웨어 구성을 필요로 하지 않으면서 집안의 고정된 게이트웨이로 인해서 생기는 위치종속성 문제를 해결할 수 있는 PMG(personal mobile gateway) 기반의 홈&모바일 헬스케어 시스템을 개발하고자 한다.

  • PDF

Evaluation of the 256ch Flat Panel PS-PMT on Positioning Image Histogram for PET

  • Orita, Narimichi;Murayama, Hideo;Kawai, Hideyuki;Inadama, Naoko;Umehara, Takaya;Kasahara, Takehiro;Tsuda, Tomoaki
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.324-327
    • /
    • 2002
  • For a next generation PET that realizes high sensitivity and high resolution, we proposed a design of a depth of interaction detector. A unit of the detector is constructed of four stages rectangular blocks of 2 by 2 Gd$_2$SiO$\sub$5/: Ce (GSO) crystal array optically coupled to position sensitive photomultiplier tube (PS-PMT). The 256ch flat panel PS-PMT is under development by Hamamatsu Photonics K.K., JAPAN. It has large cathode area, 51.7 by 51.7 mm$^2$, and the ratio of the effective area to external size is about 90%. The feature will contribute high packing fraction, accordingly high sensitivity. The 256 anodes are arranged in 16 by 16 at intervals of 3.0 mm. So as to evaluate the detector capability for identifying crystal of interaction, we got positioning image histograms with coupling a 16 by 5 array of GSO crystals, 2.9 by 2.9 by 7.5 mm$^3$, to the PS-PMT by irradiating a gamma ray uniformly from a point source. Flat panel PS-PMT is a new promising device for PET. We need to evaluate it if its performance is sufficiency. The performance was compared to the one with a 16ch PS-PMT.

  • PDF

Special quality research about action output waveform change by gap (1.0mm and 1.6mm) difference of $CO_2$ laser for skin disease (피부질환을 위한 $CO_2$ 레이저의 공극차이에 따른 동작출력 변화에 관한 연구)

  • Kim, Whi-Young
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.52-54
    • /
    • 2007
  • Laser wave length can have evaporation effect by absorption because outer skin or tissue of focus is consisted of water almost though absorption of water occurs more than 90% almost in formation thickness of very thin floor. Can operate outer skin, steam by floor and correct incision of formation is available. Suture surgical operation is available to vein or lymph system and surgical operation region can dry and see as eye and radish bleeding surgical operation is available. Specially, stability of tube both end output about pulse by weight very, this research can cause various curative effect because can reduce bulk and control easily current wave style of medical laser using electric power conversion device of high frequency way. If introduce ZVS (Zero Voltage Switching) or ZVZCS (Zero Voltage and Zero Current Switching), is more profitable because can reduce switching damage. Because electric power department of proposed medical laser can do stable soft-switching in wide subordinate extent introducing ZVZCS technique by the first help and control department composes microcontroller, output current waveform user have free form make. Result that experiment because design and manufacture, brought result that improve of 20% than existing equipment, and will be bought to get into superior result if supplement as systematic late.

  • PDF

Development of a Cantilevered Patient Table Considering X-ray Transparency (X-선 투과특성을 고려한 외주형 수술용 테이블 개발)

  • Won B.H.;Chun K.J.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.189-190
    • /
    • 2006
  • A patient table considering x-ray transparency, mechanical safety and compact multi-axis moving mechanism has been developed. The goal of medical imaging technology is to keep radiation exposure of patients during x-raying to a minimum. In order to obtain clear pictures at low dose, however, the x-ray table which supports the patient must be sufficiently permeable to radiation to allow good image resolution. The table top is made of low density foam for x-ray transparent effective area and structural aluminum plate to connect moving mechanism under the table, covered with thin carbon fiber. This sandwich construction is very rigid and lightweight, so the table top can handle relatively heavy load comparing to its cantilevered structure which is unavoidable as long as cooperate with C-arm radiography. To verify the design results finite element static analysis and experimental tests have been done. According to the verification the results well satisfy certification guide lines as a medical device.

  • PDF

A Study on the Evaluation of Hydrodynamic Performance of Trileaflet Prosthetic Heart Valves (삼엽식 인공판막의 수력학적 성능평가에 관한 연구)

  • 김혁필;이계한
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.2
    • /
    • pp.147-156
    • /
    • 1997
  • Various prosthetic heart valves have been developed and used clinically, but they have problems, such as thrombogenecity, hemoltsis, high cost and low durability. New types of trileaflet polymer heart valves have been developed in order to use them as inlet and outlet valves in a ventricular assist device. The aim of this study is to determine the hydrodynamic effectiveness of the newly designed trileaflet polymer valves and their feasibility for temporary use in the blood pumps. Trileaflet polymer valves are made of polyurethane, because of its good blood compatibility, high tonsil strength and good resistance to fatigue. An in vitro experimental investigation was perf'ormed in order to ev91ua1e hydrodynamic performance of the trileaflet polymer valves having different design and fabrication tech- niques. The St. Jude Medical valve (SJMV) and floating-type monoleaflet polymer valve (MLPV) were also tested The pressure drop across the valve, leakage volume, and the flow patterns mere investigated for valves. The result of comparative tests showed that the trileaflet polymer valves had a better hydrodynamic performance than the others. TPV which has two stable membrane shape showed the lowest back flow. The pressure hops of TPVs were lower than that of MLPV, but slightly higher than SJMV. The hydrodynamic performance of valves under the pulastile flow showed the similar results as steady flow. The velocity profiles and turbulent intensities were measured at the distal sites of valves using a hot-film anemometer. Central flow was maintained in trileaflet polymer valves, and the maximum turbulent intensities were lower in TPVs comparing to MLPV.

  • PDF

Quantum cryptography-used Key Distribution Model Design of U-healthcare environment (양자 암호를 이용한 유헬스케어 환경의 키 분배 모델 설계)

  • Jeong, Yoon-Su;Han, Kun-Hee
    • Journal of Digital Convergence
    • /
    • v.11 no.11
    • /
    • pp.389-395
    • /
    • 2013
  • As fusing IT and medical technique, the number of patients who adhere medical equipment inside of them is increasing. However there is a problem of for the third person to tap or modulate the patient's biometric data viciously. This paper suggests quantum encryption-based key distribution model to share key for the third person not to tap or modulate the patient's biometric data between patient and hospital staff. The proposed model uses one-time pad key that shares key sending random bits not direct sending message of quantum data. Also, it guarantees patient's anonymity because the biometric data of injected-device in the body doesn't be exposed unnecessarily.

A Study on the Development of Telephone for Improvement of the Hearing Impaired's Listening (난청인의 통화 청취도 향상을 위한 전화기 개발연구)

  • Lee, S.M.;Woo, B.C.;Kim, D.W.;Song, C.G.;Lee, Y.M.;Kim, W.K.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.111-113
    • /
    • 1996
  • The impaired person and the elderly who has hearing loss have been continuously increased and these people's desire for participating society as a producer has been increased also. So they strongly request the aid device which can compensate their handicap. The healing aid telephone is one of the basic aid devices that helps the hearing impaired to communicate with other people and to acquire useful information. We design the new model of the hearing aid telephone and test it's efficiency in three fields - electrical, speech perception, user test. From the result of the test we certify that the new model is better for the hearing impaired to understand the meaning of telephone speech than the old general models. We expect that the advanced healing aid telephone can be developed by the research about speech perception characteristics of the hearing impaired in engineering and clinical side.

  • PDF

In-Vitro Model Design of Mitral Valve Regurgitation and Comparative Study of Quantification between PISA and 4D flow MRI (승모판 역류 In-Vitro 모델을 활용한 초음파 및 4D flow MRI 기반 혈류 정량화 비교연구)

  • Juyeon Lee;Minseong Kwon;Hyungkyu Huh
    • Journal of the Korean Society of Visualization
    • /
    • v.22 no.1
    • /
    • pp.40-48
    • /
    • 2024
  • This study presents an in-vitro model designed to simulate mitral valve regurgitation, aiming to compare the quantification results between Proximal Isovelocity Surface Area(PISA) and 4D Flow MRI on both fixed and valve annulus tracking(VAT) views. The in-vitro model replicates the dynamic conditions of the mitral valve in a pulsatile environment, utilizing a piston pump set at 60 bpm. Through systematic experiments and analysis, the study evaluates the accuracy and effectiveness of PISA and 4D Flow MRI in assessing regurgitation severity, considering both fixed and valve annulus tracking. The displacement length measured in echo closely resembled that of optical measurements, making it advantageous for structural analysis. VAT-4D flow MRI exhibited the smallest deviation from actual flow rate values, establishing it as most accurate method for quantitative regurgitation assessment.

Design and Implementation of IoT Terminal Equipment for Vessels using Thuraya Geo-stationary Orbit Satellite (Thuraya 정지궤도 위성을 이용한 선박용 IoT 단말 장치 설계 및 구현)

  • Jang, Won-Chang;Lee, Myung-Eui
    • Journal of Advanced Navigation Technology
    • /
    • v.24 no.2
    • /
    • pp.67-72
    • /
    • 2020
  • Satellite communication is not used by many people like mobile communication, but it is a necessary technology for public service and communication services, such as providing the Internet in military, disaster, remote education and medical services, island areas, and infrastructure vulnerable areas. However, on ships and aircraft, mobile communications requiring base stations are either unavailable or restricted in their use. In this paper, we used a Raspberry Pi board as the terminal device to communicate network through satellite modem and PPP protocol, and implemented two-way data link using the text message of the modem to connect to the Thuraya geo-stationary orbit network. In addition, I/O devices were connected to the controller of the terminal equipment to design and implement an IoT device system for ships that can remotely access the system under control and control I/Os and transmit measured data through various sensors.