• Title/Summary/Keyword: Medical Device Design

Search Result 262, Processing Time 0.026 seconds

Design and Implementation of a Mobile-based Sarcopenia Prediction and Monitoring System (모바일 기반의 '근감소증' 예측 및 모니터링 시스템 설계 및 구현)

  • Kang, Hyeonmin;Park, Chaieun;Ju, Minina;Seo, Seokkyo;Jeon, Justin Y.;Kim, Jinwoo
    • Journal of Korea Multimedia Society
    • /
    • v.25 no.3
    • /
    • pp.510-518
    • /
    • 2022
  • This paper confirmed the technical reliability of mobile-based sarcopenia prediction and monitoring system. In implementing the developed system, we designed using only sensors built into a smartphone without a separate external device. The prediction system predicts the possibility of sarcopenia without visiting a hospital by performing the SARC-F survey, the 5-time chair stand test, and the rapid tapping test. The Monitoring system tracks and analyzes the average walking speed in daily life to quickly detect the risk of sarcopenia. Through this, it is possible to rapid detection of undiagnosed risk of undiagnosed sarcopenia and initiate appropriate medical treatment. Through prediction and monitoring system, the user may predict and manage sarcopenia, and the developed system can have a positive effect on reducing medical demand and reducing medical costs. In addition, collected data is useful for the patient-doctor communication. Furthermore, the collected data can be used for learning data of artificial intelligence, contributing to medical artificial intelligence and e-health industry.

Design of A Downlink Power Control Scheme in Unequal Error Protection Multi-Code CDMA Mobile Medicine System

  • Lin, Chin-Feng;Lee, Hsin-Wang;Hung, Shih-Ii;Li, Ching-Yi
    • Proceedings of the Korea Society of Information Technology Applications Conference
    • /
    • 2005.11a
    • /
    • pp.335-338
    • /
    • 2005
  • In this paper, we propose a downlink power control scheme to apply in the unequal error protection multi-code CDMA mobile medicine system. The mobile medicine system contains (i) blood pressure and body temperature measurement value, (ii) ECG medical signals measured by the electrocardiogram device, (iii) mobile patient's history, (iv) G.729 audio signal, MPEG-4 CCD sensor video signal, and JPEG2000 medical image. By the help of the multi-code CDMA spread spectrum communication system with downlink power control scheme and unequal error protection strategy, it is possible to transmit mobile medicine media and meet the quality of service. Numerical analysis and simulation results show that the system is a well transmission platform in mobile medicine.

  • PDF

The effect of applying a head-weight device on cervical angle and pain of neck muscles

  • Kim, Jin-Hong;Kim, Jong-Gun;Do, Kwang-Sun;Yim, Jongeun
    • Physical Therapy Rehabilitation Science
    • /
    • v.5 no.2
    • /
    • pp.101-105
    • /
    • 2016
  • Objective: The purpose of this study was to measure the change in pain threshold of levator scapular muscle, carniovertebral angle, and head position angle when applying a head-weight device on healthy adult. Design: Cross-sectional study. Methods: This study was conducted with 21 healthy adult male and female who voluntarily agreed to participate in this study after being informed of the purpose and method of this study. After measuring the cervical angle and pain threshold of levator scapular muscle, subject was instructed to walk for 5 minutes on a treadmill at a speed of less than 5 km/h while wearing after wearing head-weight device of 0.5 kg. Then, cervical spine angle and pain threshold of levator scapula muscle were re-measured. Measurement of cervical spine angle was conducted with photo by using the Bluebeam Revu software and the pain pressure thresholds (PPTs) were measured using an electronic algometer over potential trigger points on the body. Results: The results cervical angle showed a significant change, from $49.62^{\circ}$ to $52.10^{\circ}$ (p<0.05). PPT showed a significant change, from 30.71 to 36.89 (p<0.05). Conclusions: These findings suggest that applying head-weight device has a positive influence on increasing cervical angle and reducing pain when applied as a therapeutic intervention method of forward head posture.

Design of Deep De-nosing Network for Power Line Artifact in Electrocardiogram (심전도 신호의 전력선 잡음 제거를 위한 Deep De-noising Network 설계)

  • Kwon, Oyun;Lee, JeeEun;Kwon, Jun Hwan;Lim, Seong Jun;Yoo, Sun Kook
    • Journal of Korea Multimedia Society
    • /
    • v.23 no.3
    • /
    • pp.402-411
    • /
    • 2020
  • Power line noise in electrocardiogram signals makes it difficult to diagnose cardiovascular disease. ECG signals without power line noise are needed to increase the accuracy of diagnosis. In this paper, it is proposed DNN(Deep Neural Network) model to remove the power line noise in ECG. The proposed model is learned with noisy ECG, and clean ECG. Performance of the proposed model were performed in various environments(varying amplitude, frequency change, real-time amplitude change). The evaluation used signal-to-noise ratio and root mean square error (RMSE). The difference in evaluation metrics between the noisy ECG signals and the de-noising ECG signals can demonstrate effectiveness as the de-noising model. The proposed DNN model learning result was a decrease in RMSE 0.0224dB and a increase in signal-to-noise ratio 1.048dB. The results performed in various environments showed a decrease in RMSE 1.7672dB and a increase in signal-to-noise ratio 15.1879dB in amplitude changes, a decrease in RMSE 0.0823dB and a increase in signal-to-noise ratio 4.9287dB in frequency changes. Finally, in real-time amplitude changes, RMSE was decreased 0.3886dB and signal-to-noise ratio was increased 11.4536dB. Thus, it was shown that the proposed DNN model can de-noise power line noise in ECG.

Intra- and inter-rater reliability of muscle thickness measurement of the tibialis anterior using different inward pressures

  • Lee, Seong-Joo;Lim, Ji Young;Lee, Chang-Hyung;Park, Dae-Sung
    • Physical Therapy Rehabilitation Science
    • /
    • v.8 no.4
    • /
    • pp.218-224
    • /
    • 2019
  • Objective: This reliability study examined the effects of applying varying induced inward pressures using a transducer placed at 0° neutral ankle position (NEU) and 15° ankle dorsiflexion (DF) on tibialis anterior (TA) muscle thickness using a custom-made device with a force indicator during rehabilitative ultrasound imaging. Design: Cross-sectional study. Methods: Twenty-four healthy subjects were recruited in this study. Two examiners measured the muscle thickness of the TA at 0° NEU and 15° DF in 3 conditions of inward pressures (1.0 N, 2.0 N, and 4.0 N) using a custom-made holder. The muscle thickness was measured three times for each of the conditions arranged in random order. For intra- and inter-rater reliability, the intraclass correlation coefficients (ICCs) with 95% confidence intervals, standard error of measurement, minimal detectable change, and coefficient of variation were analyzed. One-way repeated measures analysis of variance was conducted for investigating changes of TA muscle thickness according to the inward pressures of the transducers. Results: The intra-rater reliability of TA muscle thickness measurement was excellent (ICC3,1: 0.92-0.96) for all conditions (at both ankle joint angles per varying inward pressure). Likewise, the inter-rater reliability of TA muscle thickness measurement was excellent (ICC2,1: 0.89-0.97) under same conditions. The mean of TA thickness showed the trend of decreasing significantly with increased inward pressures at all ankle joint angles (p<0.05). Conclusions: Use of this custom-made device with a force indicator is useful to accomplish the high intra- and inter-rater reliability of TA muscle thickness measurement at both ankle joint angles in reducing the measurement error.

Reliability and Validity of an Electronic Inspiratory Loading Device for Assessing Pulmonary Function in Patients with COPD

  • Lee, Seugcheol;You, Seongkwang;Yang, Subin;Park, Daesung
    • Physical Therapy Rehabilitation Science
    • /
    • v.10 no.1
    • /
    • pp.40-47
    • /
    • 2021
  • Objective: The purpose of this study is to prove the reliability and validity of the Power breath K5 and to compare it with pony FX. Power breathe K5 is one type of device can assess automatically Maximum inspiratory pressure (MIP), Peak inspiratory pressure, Peak inspiratory flow (PIF). Design: Cross-sectional study. Methods: Thirty-five COPD patients participated in the test to investigate for the intra relater reliability and concurrent validity. The tests MIP, Vital capacity (VC), PIF were measured by Powerbreathe K5 and Pony Fx. Data was analyzed by intraclass correlation reliability (ICC) value and a standard error of measurement and Bland-Altman plots for reliability and pearson correlation for validity. Results: Intra rater reliability of the Powerbreathe K5 was very high at MIP (ICC=0.977 95%CI 0.956~0.989, SEM=8.665, MDC=0.295), PIF (ICC=0.966 95%CI 0.933~0.93, SEM=8.665, MDC=0.295), VC (ICC=0.949 95CI 0.902~0.974, SEM=0.042, MDC=0.116). The Powerbreath K5 was significant correlation compared with Pony Fx in assessment for MIP (r=0.971, p<0.05) and vital capacity (r=0.534, p<0.05). Conclusion: In this study, We investigated the clinical usefulness of the Powerbreath K5 in evaulating the MIP, VC and PIF with COPD patients with high reliability and validity.

A Study on Developing Safety and Performance Assessment Guideline for Electronic Warm-Acupuncture Apparatus (전기식 온침기에 대한 안전성 및 성능평가 가이드라인 개발 연구)

  • Hansol Jang;U-Ryeong Chung;Jeong-Hyun Moon;Seong-Kyeong Choi;Won-Suk Sung;Min-Seop Hwang;Seung-Deok Lee;Kyung-Ho Kim;Jong-Hwa Yoon;Eun-Jung Kim
    • The Journal of Korean Medicine
    • /
    • v.43 no.3
    • /
    • pp.150-163
    • /
    • 2022
  • Objectives: This research aimed to develop a guideline for evaluating safety and performance of electronic warm-acupuncture apparatus. With the development of medical devices like electronic warm-acupuncture apparatus with improved performance, convenience and safety measures compared to traditional warm-acupuncture needling, safety and performance guideline is a necessity. Methods: By referring to existing standards and guidelines of other electronic devices for Korean medicine with heating function, guideline for safety and performance assessment of electronic warm-acupuncture apparatus was drafted Results: The guideline, presents explanation for adequate temperature and settings of the apparatus, and safety measurements providing against thermal runaway situations along with guidelines for the manual. Guideline for detailed test method for the performance of the apparatus such as accuracy of temperature increase and the timer, and safety unit was also provided. The test items and suggested test methods for the requirements of biological, electrical and electromagnetic safety were referred to Korean approval documents of ministry of Food and Drug Safety. Conclusion: We proposed the relevant items to verify performance and safety of warm-acupuncture apparatus to assure patient safety and improve the quality of currently developing devices for application in clinical field.

A Design of Service Improvement Model for Emergency Medical System using Augmented Reality (증강현실을 이용한 응급환자 의료서비스 향상 모델 설계)

  • Jeong, Yoon-Su;Kim, Yong-Tae;Park, Gil-Cheol
    • Journal of Convergence for Information Technology
    • /
    • v.7 no.1
    • /
    • pp.17-24
    • /
    • 2017
  • In the medical field, augmented reality is being used for surgical and medical education. However, augmented reality technology is not applied to emergency patients. In this paper, we propose a medical service support model that can support rapid medical service to emergency patients through an augmented reality - based IT device. The proposed model has the function of collecting the information necessary for the first aid simply through the IT equipment based on the reality of reality, and also receiving the first aid method appropriate for the emergency situation to the medical staff and supporting the service. In addition, the proposed model hierarchically collects information related to emergency patient information inquiry, emergency patient status and emergency treatment based on Analytic Hierarchy Process (AHP). The collected information uses a pair of comparison matrices to compensate for the ambiguity between the information. In particular, the collected information is stored in the server of the medical staff, and in addition to the unique information of the collected information, the collected information can be reflected in the medical service of the medical staff.

A Health Assessment Platform with IoT Devices (IoT 디바이스를 이용한 건강 평가 플랫폼)

  • La, Hyun Jung;Kim, Moon Kwon;Kim, Soo Dong
    • KIISE Transactions on Computing Practices
    • /
    • v.22 no.5
    • /
    • pp.225-234
    • /
    • 2016
  • The emergence of diverse medical Internet of Things (IoT) devices has facilitated the collection and analysis of medical contexts to assess health conditions. However, the complexity of IoT-based systems for health assessment is quiet high and it requires high development cost, since the designs of the systems highly depend on the heath aspects to be evaluated. In this paper, we propose a design of the platform that provides generic functionalities to various health evaluation applications. We first define a metric for computing a health index, which is a generic health assessment model. And, based on the proposed generic health index, we propose a design of the platform to evaluate diverse aspects of the health including its hardware architecture, software architecture and database design. We describe the result of developing Rainbow Toilet System based on the proposed platform, and assess the practical applicability.

A Proposal for Improving Techniques of GTS Utilization Based on WBAN (WBAN 기반의 GTS 채널 이용률 향상기법 제안)

  • Park, Joo-Hee;Jung, Won-Soo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.16 no.10
    • /
    • pp.73-81
    • /
    • 2011
  • The WBAN(Wireless Body Area Network) technology is a short distance wireless network which provides each device's interactive communication by connecting devices inside and outside of body located within 3 meters. Standardization on the physical layer, data link layer, network layer and application layer is in progress by IEEE 802.15.6 TG BAN. The The WBAN servides consists of both medical and non-medical applications. The medical application service uses the sensor that transfer the periodic traffic and have different data rates. It uses GTS method to guarantee QoS. In this paper, a new method is proposed, which are suitable design for MAC Protocol. Firstly, MAC frame structure and a primitive based on the WBAN are proposed. Secondly, we proposed the GTS algorithm improved the channel utilization based on the WFQ(Weighted Fair Queuing). The proposed scheduling method is improved channel utilization compared with i-Game(Round Robin scheduling method).