• Title/Summary/Keyword: Medical Characteristic

Search Result 1,379, Processing Time 0.045 seconds

Research on the Status Inquiry and Complex Characters of Public Facilities for the Community Life Style in Seoul (서울시 주민생활지원을 위한 공공시설의 현황 및 복합화 특성에 관한 조사연구)

  • Suh, Kuee-Sook
    • Journal of the Korean housing association
    • /
    • v.21 no.2
    • /
    • pp.19-30
    • /
    • 2010
  • The aim of this research is to understand the characteristics and status of existing public facilities, in order to propose the necessary basic materials for the planning and development of improved public facilities to assist communities. Objects of this research are the public facilities provided by the Government throughout the 25gu in Seoul. The methods of this research were carried out through the home page of each facility, telephone inquiries and gujung backseo. Investigations were carried out 3 times between the periods of January-June and September in 2009. Results of the research are as follows - 1) Through the investigations of classifications and distribution status of 5 public facilities over 25gu, quantity supply problems were analyzed. 2) Building distributions of 5 public facilities were classified by types and analyzed. 3) A number of compound facilities were classified and analyzed to determine the complexities of the 5 public facilities. 4) Complex types and characteristics of public facilities in 25gu in Seoul were analyzed. Based on the results of the research, the following conclusions are drawn: 1) Public facilities throughout the 25gu in Seoul have common characteristics and functions and they are spread out evenly in each gu. This means that public facilities are standardized in Seoul. Characteristic public facilities suitable to each gu should be planned accordingly. 2) Public facilities in Seoul show a single form of one facility. Therefore, initiative plans for the complexity of facilities are required. 3) Complex public facilities in Seoul need to be the center of community life in each gu. It is necessary to take into account the diverse life styles and classified needs of residents for complex facilities. Based on the research, complex types such as public administrative+cultural facilities, culture+welfare facilities, medical+welfare facilities can be presented. These complex types should not be classified according to any particular use, but they should be commonly used by diverse generations and every social class. The inquiries of users of public facilities and the programs of each public facility are not included in this research. Thus, the reseaarch limits the proposals for complex public facilities. In the future, the characteristics of each gu in Seoul should be studied and understood, so that appropriate public facilities and their complex plans can be researched continuously and necessarily.

Spectral Properties of the Sound From the Mechanical Valve Employed in an Implantable Biventricular Assist Device (이식형 양심실 보조 장치에 사용된 기계식 판막의 음향 스펙트럼 특성)

  • 최민주;이서우;이혁수;민병구
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.5
    • /
    • pp.439-448
    • /
    • 2001
  • This paper considers the acoustical characteristics of the closing click sounds of the mechanical valves employed in an implantable biventricular assist device (BYAD) and their re1evance to the Physical states of the valved. Bj rk Shiley Convexo Concave tilting disk valve was chosen for the study and acoustic measurement was made for the BYAD operated in a mock circulatory system as well as implanted in an animal (sheep). In the BYAD operated in the mock circulatory system. three different states of the valve were examined, ie. normal. mechanically damaged. pseudo-thrombus attached. Microphone measurement for the BVAD implanted in the animal was carried out for five days at a regular time interval from one day after implantation. Characteristic spectrum of the sound from the valve was estimated using Multiple Signal Classification (MUSIC) in which the optimal order was determined according to Bayesian Information Criterion (BIC) . It was observed that the mechanical damage of the valve resulted in changes of the structure of the acoustic spectrum. In contrast. the thrombus formed on the valve did not change much the basic structure of the spectrum but brought about altering the spectral Peak frequencies and energies. Maximum spectral Peak (MSP) with the greatest energy was seen at 2 kHz for the normal valve and it was shifted to 3 kHz for the calve attaching the Pseudo-thrombus. Unlike the normal valve, strong spectral Peak appeared around 7 kHz in the sound from the valve mechanically damaged. In the case of the BYAD implanted in the animal. as the thrombus grew, acoustic energy was reduced relatively more in the low frequency components (〈 2 kHz) and the frequencies of the 1st, 2nd and 3rd MSP were increased little. The thrombus formation would result in reduction in both the variability of the 1st, 2nd and 3rd MSP and the value of the BIC optimal order.

  • PDF

A Clinical and Polysomnographic Study of Parkinson's Disease Patients with Sleep Benefit (수면이득이 있는 파킨슨병 환자의 임상특징 및 수면다원검사에 대한 연구)

  • Chun, Dong-Yeol;Yang, Chang-Kook;Kim, Jae-Woo;Yoo, Seung-Yoon;Hahn, Hong-Moo
    • Sleep Medicine and Psychophysiology
    • /
    • v.7 no.2
    • /
    • pp.102-108
    • /
    • 2000
  • Objectives: Parkinson's disease (PD) patients may experience fluent mobility upon awakening from a night's sleep, which is called sleep benefit (SB). Although SB is a phenomenon closely associated with sleep, sleep features of PD are not well characterized. The objectives of this study were, first, to investigate if there are any clinical characteristic features between patients with SB and without SB (NSB), and second, to examine if SB patients are associated with any specific sleep variables compared with NSB patients. Methods: Thirty-three PD patients (14 men and 19 women) participated in this study. All subjects were interviewed to examine whether or not they had SB and overnight polysomnography was performed at the sleep center. Various clinical variables were collected through medical record review. Results: The 331 PD patients were divided into 16 SB group (48.5%) and 17 NSB group (51.5%). SB patients were younger (p<0.02), had higher sleep efficiency (p<0.05), and showed shortened sleep latency (p<0.02) as compared with NSB patients. However, no difference was found between SB and NSB with respect to gender, duration or stage of PD, antiparkinsonian medications prescribed, and predominant motor symptoms. SB did not clearly relate to a specific sleep stage and other sleep variables except sleep efficiency and sleep latency. Although primary snoring was more prevalent in SB patients (p<0.05), other sleep disorders were seen with equal frequency in SB and NSB groups. Conclusion: Our results suggest that good sleep efficiency, shortened sleep latency, and age may have an effect on morning motor function (i.e., SB) in Parkinson's disease.

  • PDF

Foot/Ankle Roll-Over Characteristics According to Different Heel Heights of Shoe during Walking (보행 시 신발 굴 높이어 따른 발/발목 복합체의 Roll-Over특성)

  • Kim, Young-Ho;Choi, Hue-Seok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.4
    • /
    • pp.247-253
    • /
    • 2005
  • This study investigated the effects on foot and ankle roll-over characteristics according to different heel heights during walking. Fifteen female volunteers who have neither musculoskeletal nor foot problems were participated in gait analyses, wearing four different pairs of shoes in different heel heights. To obtain roll-over shape of foot/ankle complex, we used trajectories of knee and ankle joints as well as the renter of pressure between initial contact and opposite initial contact. Results revealed that the entire roll-over shape moved distally as the heel height increased but roll-over characteristics showed uniformly with different heel heights. In addition, we found that nondisablea persons automatically adapted to their foot/ankle complex to varying heel heights within 6cm, by moving the origin of roll-over shape distally to maintain roll-over characteristics. However, since the balance of the gait only by the ankle joint could not be achieved beyond the heel height of 6cm, compensations at the knee and the hip joints occurred simultaneously. Roll-over characteristics in human walking would provide simpler and wider understanding of human walking, and furthermore could be applied to the wide understanding of prosthetics and orthotics of the lower extremity as well as orthopaedic shoes.

A Study on Characteristics of Exposure to Tetrahydrofuran of Manufacturing and Handling Workers (테트라하이드로퓨란 제조 및 취급 근로자의 노출특성에 관한 연구)

  • Chio, Ho Chun;Hong, Jwa Ryung;Lee, Gye Young;Kim, Doo Ho;Park, Chung Yill
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.21 no.3
    • /
    • pp.156-161
    • /
    • 2011
  • Objectives: Tetrahydrofuran (THF) is a colorless, water-miscible organic liquid with low viscosity at standard temperature and pressure. THF has been used as a solvent and a precursor for various syntheses of polymers. However, THF is known to irritate to the eyes, skin and mucus membranes. Overexposure by inhalation, ingestion or skin contact may produce nausea, dizziness, headaches, respiratory irritation and possible skin burns. The purpose of this study is to evaluate of the worker exposure and characteristics of workers in the workplaces that use or manufacture THF. Methods: Sixteen factories in Korea, which manufacture or use THF, were selected for this study and a total of 130 air samples including 104 time-weighted average (TWA) samples and 26 short-term exposure limit (STEL) samples, were collected. Air samples were collected with charcoal tube (100mg/50mg) and analyzed by gas chromatograph/flame ionization detector(GC/FID). Results: The TWA concentration of THF was 16.05ppm (GM) at PS script printing, 2.32ppm (GM) at PVC stabilizer, 1.03ppm (GM) at Lithium triethylborohydride, 0.63ppm (GM) at Polytetramethylene ether glycol(PTMEG), 0.42ppm (GM) at Manufacturing THF, 0.13ppm (GM) at Glue and 0.12ppm (GM) at synthetic rubber/resins. Two out of sampes for PS script printing exceeded 50ppm as 8-hour exposure limit of MOEL. The short term exposure to THF was 54.77ppm (GM) at PS script printing, 17.10ppm (GM) at PTMEG, 13.76ppm (GM) at Manufacturing THF, 2.86ppm (GM) at Lithium triethylborohydride, 0.87ppm (GM) at synthetic rubber/resins and 0.13ppm (GM) Glue. We found that the highest exposure process for both the TWA and STEL samples was PS script process. Two samples exceeded 100ppm as short term exposure limit of Ministry of Employment and Labor(MOEL). Conclusions: Characteristic of STEL concentration for THF is considerably different from TWA concentration in workplaces because workers could exposure high concentration of THF in a moment when they work irregularly schedule. So exposure controls for momentary works have to be prepared, and considered the skin absorption and inhale of THF.

Clinical outcomes of adjuvant radiation therapy and prognostic factors in early stage uterine cervical cancer

  • Kim, Hyun Ju;Rhee, Woo Joong;Choi, Seo Hee;Nam, Eun Ji;Kim, Sang Wun;Kim, Sunghoon;Kim, Young Tae;Kim, Gwi Eon;Kim, Yong Bae
    • Radiation Oncology Journal
    • /
    • v.33 no.2
    • /
    • pp.126-133
    • /
    • 2015
  • Purpose: To evaluate the outcomes of adjuvant radiotherapy (RT) and to analyze prognostic factors of survival in the International Federation of Gynecology and Obstetrics (FIGO) IB-IIA uterine cervical cancer. Materials and Methods: We retrospectively reviewed the medical records of 148 patients with FIGO IB-IIA uterine cervical cancer who underwent surgery followed by adjuvant RT at the Yonsei Cancer Center between June 1997 and December 2011. Adjuvant radiotherapy was delivered to the whole pelvis or an extended field with or without brachytherapy. Among all patients, 57 (38.5%) received adjuvant chemotherapy either concurrently or sequentially. To analyze prognostic factors, we assessed clinicopathologic variables and metabolic parameters measured on preoperative 18F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT). To evaluate the predictive performance of metabolic parameters, receiver operating characteristic curve analysis was used. Overall survival (OS) and disease-free survival (DFS) were analyzed by the Kaplan-Meier method. Results: The median follow-up period was 63.2 months (range, 2.7 to 206.8 months). Locoregional recurrence alone occurred in 6 patients, while distant metastasis was present in 16 patients, including 2 patients with simultaneous regional failure. The 5-year and 10-year OSs were 87.0% and 85.4%, respectively. The 5-year and 10-year DFSs were 83.8% and 82.5%, respectively. In multivariate analysis, pathologic type and tumor size were shown to be significant prognostic factors associated with both DFS and OS. In subset analysis of 40 patients who underwent preoperative PET/CT, total lesion glycolysis was shown to be the most significant prognostic factor among the clinicopathologic variables and metabolic parameters for DFS. Conclusion: Our results demonstrated that adjuvant RT following hysterectomy effectively improves local control. From the subset analysis of preoperative PET/CT, we can consider that metabolic parameters may hold prognostic significance in early uterine cervical cancer patients. More effective systemic treatments might be needed to reduce distant metastasis in these patients.

A Trial for Development of Health Profile (KHP 1.0) to Measure the Self-Perceived Health Status of Korean (한국인의 자가평가 건강수준 측정도구(KHP 1.0) 개발)

  • Yang, Jin-Sun;Chun, Jin-Ho
    • Journal of Preventive Medicine and Public Health
    • /
    • v.36 no.1
    • /
    • pp.11-23
    • /
    • 2003
  • Objectives : The 1990s has seen advances in the conceptualization of self-perceived health status which has important roles for individual health and the quality of life. Many types of standardized questionnaires have been developed with the current wide use of SF-36, NHP, andEuroQol. However, the outcomes of these tools may be different with regard to regional, cultural and emotional backgrounds. The purpose of this study was to trial the development of a Korean Health Profile (KHP 1.0) to measure the self-perceived health stati of Koreans. Methods : The KHP 1.0 was designed on the basis of the Medical Outcome Study Form 36 (SF-36), the Nottingham Health Profile (NHP), and the EuroQOL. It was composed of 9 scales; physical functioning, role limitation-physical, pain, general health, energy, social isolation, sleep, role limitation-emotional, and e-motional health. Self-reported chronic disease conditions, and the Zung's Self-Rating Depression Scale (SDS), were also checked for the evaluation of clinical validity. This study was conducted, from December 2000 to January 2001, on 800 middle-aged parents, with four high school students, with 100 retest sets being conducted two weeks later. From the 800 subjects there were 588 complete responses (effective response 73.5%). The reliability of the test-retest results, and the factor analysis on the validity of the KHP 1.0 components, were evaluated using the SPSS (ver 10.0) software. Results : The reliability of the KHP 1.0 was good with Cronbach's alpha (>0.6), test-retest correlation coefficients (>0.5), but with no significant differences from the paired t-test. From the psychometric validity tests, the 9 scales of the KHP 1.0 were divided into two components; physical and mental, and trimmed to the established model with 55% of the total variance, with the exception of role limitation-emotional. The clinical validity on the basis of the comparison for the four characteristic groups; healthy, physical conditions only, mental conditions only, and physical and mental conditions were also good. Conclusions : The KHP 1.0 appears to be a valid measurement tool of self-perceived health stati of Koreans, although there are limitations, i.e. sample size was too small, a limited number of middle-aged subjects, and it was based on unconfirmed diagnoses, etc. Therefore, further study is required to standardize the assessment.

Quality Improvement Nurses' Experiences of Working for Healthcare Quality in Public Hospitals (공공병원 의료 질 관리 전담자의 의료 질 향상 활동 경험연구)

  • Hwang, Jeonghae;Park, Seong-Hi;Choi, Yun-Kyoung
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.10
    • /
    • pp.19-29
    • /
    • 2017
  • Purpose : To describe and understand the experience of QI (quality improvement) nurses related to the hospital QI activities in public general hospitals. Methods : Purposive sampling was conducted 10 QI nurses and who have QI work experience for more than 1 year. Data were collected through focus group interviews. Interviews were recorded, transcribed and analyzed with qualitative content analysis using Strauss and Corbin's methodology. Results : The core categories of experience with QI activities were 'the success and failure of the medical care and overall health service sector', 'the degree of activation of current QI activities', 'characteristics of public hospital QI activities', 'what is needed to activate future QI activities'. The key themes were derived as follows. 'Success of quality enhancement activities according to the characteristic of public hospitals', 'activation of public hospital QI activities through leadership and QI education', 'reorganizing the role of regional hospitals in public hospitals'. Conclusion : Physician participation is important in the success of QI activities in public hospital practice. To lead these physician participation, Sharing doctor's QI experience and providing the necessary knowledge in QI activities and helping their leadership in QI activities are needed. QI nurses at public hospitals should lead QI activities to improve national hospitals' care quality through cooperating with local hospitals.

Research on the Interior Environment Planning of a Postpartum Care Center. (산후 조리원 실내 환경 계획에 관한 연구)

  • Lee, Jong-Hee
    • Archives of design research
    • /
    • v.20 no.1 s.69
    • /
    • pp.253-262
    • /
    • 2007
  • The postpartum care center is a facility which made its debut only about 10 years ago but has now changed the nation's postpartum care culture. Women delivered of a child use the postpartum care center at this time since the low rate of childbirth has become a social phenomenon. However, while the postpartum care center is not supported legally and systematically, anybody can run it after they only file a report on businessman status with the tax office. So there are disordered wave of postpartum care startups which do not have basic facilities. Thus, this study is intended to suggest an interior environment plan considering an efficient space and users' benefits of a postpartum care center which has a characteristic difference from that of ordinary facilities in terms of targeted persons or operations but for which standards are not clear in terms of the Health and Welfare Law and the Medical Service Law. This study was conducted by investigating the actual condition of the entrance space, living space, common-use space, nursing space, administration and attached space in the six postpartum care centers selected from Seoul and Kyeonggi-do region and suggesting the direction of improvements, thus establishing the direction of interior designs and an interior environment plan. Hopefully, this study would be used as basic data on interior building plans, thus being helpful in enhancing the satisfaction of the postpartum care center user and operating the facility.

  • PDF

The Study of Driving Fatigue using HRV Analysis (HRV 분석을 이용한 운전피로도에 관한 연구)

  • 성홍모;차동익;김선웅;박세진;김철중;윤영로
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.1
    • /
    • pp.1-8
    • /
    • 2003
  • The job of long distance driving is likely to be fatiguing and requires long period alertness and attention, which make considerable demands of the driver. Driving fatigue contributes to driver related with accidents and fatalities. In this study, we investigated the relationship between the number of hours of driving and driving fatigue using heart rate variability(HRV) signal. With a more traditional measure of overall variability (standard deviation, mean, spectral values of heart rate). Nonlinear characteristics of HRV signal were analyzed using Approximate Entropy (ApEn) and Poincare plot. Five subjects drive the four passenger vehicle twice. All experiment number was 40. The test route was about 300Km continuous long highway circuit and driving time was about 3 hours. During the driving, measures of electrocardiogram(ECG) were performed at intervals of 30min. HRV signal, derived from the ECG, was analyzed using time, frequency domain parameters and nonlinear characteristic. The significance of differences on the response to driving fatigue was determined by Student's t-test. Differences were considered significant when a p value < 0.05 was observed. In the results, mean heart rate(HRmean) decreased consistently with driving time, standard deviation of RR intervals(SDRR), standard deviation of the successive difference of the RR intervals(SDSD) increased until 90min. Hereafter, they were almost unchanging until the end of the test. Normalized low frequency component $(LF_{norm})$, ratio of low to high frequency component (LF/HF) increased. We used the Approximate Entropy(ApEn), Poincare plot method to describe the nonlinear characteristics of HRV signal. Nonlinear characteristics of HRV signals decreased with driving time. Statistical significant is appeared after 60 min in all parameters.