• Title/Summary/Keyword: Medical Application

Search Result 3,933, Processing Time 0.039 seconds

경험학습이론의 의학교육에의 적용 (Application of Experiential Learning Theory to Medical Education)

  • 채수진
    • 의학교육논단
    • /
    • 제22권2호
    • /
    • pp.93-98
    • /
    • 2020
  • This paper examined the principles of experiential learning theory (ELT) relevant to learning from experience and introduces examples which were applied to medical education from a theoretical perspective. The experiential learning theory encompasses the theories of Dewey, Kolb, and Schon, whose key ideas highlight the continuity of experience, interaction of experience, and reflection. According to ELT, growth is education, and education is a reconstruction of experience. Experiential learning is a way of thinking about the educational process by constructing meaningful learning through reflection-in-action. This paper examines the learning principles of ELT and presents practical examples of the application of ELT and its implications for medical education. An in-depth understanding and application of ELT could benefit the field of medical education.

치과용 임플란트에 대한 ISO 14971 기반의 리스크관리 (Application of Risk Management for Dental Implants Based on ISO 14971)

  • 윤지훈;김영진;전계록;정창모
    • 한국안전학회지
    • /
    • 제27권2호
    • /
    • pp.92-97
    • /
    • 2012
  • Risk management is the process that helps to identify hazards, analyze them, and then to create an action plan to avoid and mitigate these hazards. The main objective of risk management in product development and manufacturing is to provide safe and efficient products without spending too many resources. Medical device manufacturers also face enormous risks - regulatory, legal, and financial - based on their products and processes, and the concepts of risk management are particularly important because any single failure may result in serious damages to body or loss of life. In this regard, a set of guidelines for the application of risk management to medical devices has been issued by ISO and specified in the document ISO 14971 Medical devices - Application of risk management to medical devices. The main objective of this study is to investigate the application of risk management to dental implant development and manufacturing processes based on ISO 14971. A general risk management process is first introduced, and the application of ISO 14971 to dental implants is further investigated.

독립성분 분석을 이용한 순수 스펙트럼 분리 (Pure-spectrum separation From simulated IR spectral data using Independent-component analysis)

  • 한상준;조혜민;윤길원
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2002년도 하계학술발표회
    • /
    • pp.148-149
    • /
    • 2002
  • 중적외선 분광학(mid-IR spectrocopy) 에서는 2.5~15 $\mu\textrm{m}$ 의 파장을 갖는 적외선을 시료에 조사하여 absorption spectrum 을 측정하는데 이 대역은 주로 분자들의 fundamental band 가 나타나는 영역으로 각 분자의 characteristic absorption band 가 비교적 깨끗하게 분리되어 있어 특정 compound 의 존재 유무를 확인하는데 쓰여 왔다. 그러나 보통의 경우에 시료에는 한 가지 화합물만이 존재하는 것이 아니고 여러 가지 화합물이 섞여 있는 경우가 많다. (중략)

  • PDF

의료기기 허가.기술문서 원자재 작성 가이드라인 개발 (The Development for guideline of raw matrials on technical document of Medical Device)

  • 박기정;유규하;이성희;이창형;정진백;이재근;허찬회;김형범;최민용;김용우;황상연;정재훈;구자중;홍혜경;임경택;강세구;곽지영
    • 대한의용생체공학회:의공학회지
    • /
    • 제31권6호
    • /
    • pp.434-437
    • /
    • 2010
  • For approval of medical devices manufactured or imported, submission of technical documents as well as the application form is required. The manufacturer (or importer) should properly identify the raw materials the applied product is made of and the manufacturing processes the product undergoes before it is shipped in the application form. In the technical documents, scientific data to evaluate the efficacy, safety, and quality of the applied product that has been described in the application form should be provided. Therefore, identifying the raw materials that were used for the parts of the applied product and describing the physical and chemical characteristics of the raw materials are quite important and essential in ensuring the efficacy, safety, and quality of the applied product. To describe the physical and chemical characteristics of the raw materials correctively, the applicant is required to have broad knowledge in the scientific fields such as chemical, polymer, metal, and ceramic science and engineering. But most of the applicant are not experts in these fields, so that the description in the application form often includes wrong and improper descriptions. Thus, we developed a guideline which explains the raw materials for medical devices, show the their examples. The purpose of this description guideline is to help the applicant properly completing the "Raw materials or constituents and their volumes" part in the application form.

바이오-메디컬 응용을 위한 마이크로 플라즈마 분사 소자 (Microplasma-Jet Device for Bio-medical Application)

  • 김강일;홍용철;김근영;양상식
    • 전기학회논문지
    • /
    • 제58권12호
    • /
    • pp.2474-2479
    • /
    • 2009
  • This paper presents an atmospheric microplasma-jet device for bio~medical application. The microplasma-jet device consists of four components; a thin Ni anode, porous alumina insulator, a stainless steel cathode and an aluminum case. The anode has 8 holes, and hole diameter and depth are $200 {\mu}m$ and $60 {\mu}m$, respectively. The discharge test was performed in atmospheric pressure using nitrogen gas and AC voltage at the optimum gas flow rate of 4 Vmin. The plasma-jet is ejected stably for the input voltage ranging from 5.5 to $9.5 kV_{p-p}$. The plasma becomes dense as the input voltage increases, which was verified by the hydrophilicity change of PMMA surface treated by the plasma. The temperature increasement of the aluminum film exposed to plasma-jet illustrates that the micro plasma-jet device is feasible for bio-medical application.

약사법규 중의 기존한약서 활용에 대한 고찰 (Study on the Application of Established Korean Medical Classics in the Korean Pharmaceutical Affairs Act)

  • 엄석기
    • 대한한의학회지
    • /
    • 제35권3호
    • /
    • pp.135-154
    • /
    • 2014
  • Purpose: There is an issue in applying various principles introduced in established Korean medical classics to "Pharmaceuticals Approval, Notification and Review" of "herbal medicinal preparations" and "new drugs from natural products" that are used for western forms of medical treatment. Thus, an analysis of the origin, purpose, and application of established Korean medical classics in the Korean Pharmaceutical Affairs Act is essential. Methods: We collected data regarding the origin, purpose, and application of established Korean medical classics in the Korean Pharmaceutical Affairs Act, and classified them by periodical change and subjects. Results: Established Korean medical classics are applied as follows: 1) as criteria for Korean medicine distributors' sales of mixed herbal drugs (Pharmaceutical Affairs Act; since 1953), 2) as official compendiums for pharmacists' preparation of Korean medicine (Ministry of Health and Welfare's authoritative interpretation; from early 1970s to 1993), 3) as standards for oriental pharmacists' quality measurement of preparations (notification of the Ministry of Health and Welfare; since 1995), 4) as criteria for "Pharmaceuticals Approval, Notification and Review" of herbal medicinal preparations and crude drug preparations (notifications regarding drug approval process by the Ministry of Health and Welfare and the Ministry of Food and Drug Safety; since 1978), and 5) as standards for the quality of materials of health functional food (from 2004 to 2011). Conclusion: The application of Korean medical classics has been closely related with the change of the laws, regulations, and systems that are relevant to Korean medicine, and it seems to be more favorable for pharmacists than oriental pharmacists. Meanwhile, regulations that apply prescriptions that are recorded in Korean medical classics - dosage, indications, and preparation methods - as criteria for the approval of crude drug preparations for western medical treatment should be abolished.

의료서비스 소비자들의 의료 웹사이트 및 어플리케이션 사용확산에 관한 연구 (An Empirical Study on a Use-Diffusion Model of Medical Service Consumer's Web Based Application Usage)

  • 장영일;정유수
    • 경영과정보연구
    • /
    • 제32권5호
    • /
    • pp.19-43
    • /
    • 2013
  • 전통적으로 새로운 기술에 대한 사용과 확산은 수용적 관점에서 많은 연구자들에게 관심거리였으며 신기술 수용후의 사용행동에 대한 설명을 위해 사용-확산(use-diffusion) 패러다임이 제시되었다. 본 연구는 새로운 마케팅 도구로서의 의료 웹사이트와 어플리케이션에 대한 소비자들의 사용유형과 지속적 사용의도를 파악하기 위해 사용확산모형을 바탕으로 의료정보의 품질, 의료 웹사이트와 어플리케이션의 사용성, 개인의 혁신성, 주관적 규범 등 사용량과 사용다양성의 선행변수로 보았다. 연구결과 주관적 규범이 의료 웹사이트나 어플리케이션의 사용량에 미치는 영향을 제외하고 모든 선행변수들이 사용다양성과 사용량에 영향을 미치는 것으로 나타났다. 이 사용량과 사용다양성의 사용유형은 의료 웹사이트와 어플리케이션이라는 새로운 의료 온라인마케팅 도구에 대한 지속적 사용과 유의한 연관성이있음을 알 수 있었다.

  • PDF

방사선 내부흡수선량의 의학적 적용 (Medical Application of Radiation Internal Dosimetry)

  • 김경민;임상무
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제42권2호
    • /
    • pp.164-171
    • /
    • 2008
  • Medical internal radiation dosimetry (MIRD) is an important part of nuclear medicine research field using therapeutic radioisotope. There have been many researches using MIRD for the development of new therapeutic approaches including radiopharmaceutical, clinical protocol, and imaging techniques. Recently, radionuclide therapy has been re-focused as new solution of intractable diseases, through to the advances of previous achievements. In this article, the basic concepts of radiation and internal radiation dosimetry are summarized to help understanding MIRD and its application to clinical application.

오적산(五積散)의 임상(臨床) 활용(活用)에 대한 방제학적(方劑學的) 고찰(考察) (A Prescriptional Study of Ojeoksan on Clinical Application)

  • 윤지연;윤용갑
    • 대한한의학방제학회지
    • /
    • 제20권2호
    • /
    • pp.153-164
    • /
    • 2012
  • Objectives : This study was intended to establish for medical treatment range of Ojeoksan and to help extending application of medical insurance through prescriptive research. Methods : We analyzed "Dongeuibogam", "Taepyeonghaeminhwajegukbang" and other books Result : 1. composition of Ojeoksan in "Dongeuibogam" is same as in "Gogeumeuigam" 2. Ojeoksan is composed of five kinds of basic prescripitions; Er Chen Tang, Ping Wei San, Ma Huang Tang, Si Wu Tang etc. and it used for five pathological factors; cold, energy, eating, phlegm, blood. 3. Property of Ojeoksan is warm so it can be used for any cold diseases. 4. Ojeoksan is used for 16 kinds of diseases including chest pain, abdominal pain etc. Conclusion : Ojeoksan can be used for cardiovascular disorders and Ojeoksan is possible to apply or to extend medical insurance coverage.

RFID를 이용한 헬스시스템에서의 정보보안 향상을 인증 메카니즘 분석 (Analyses of Enhancement of Authentication Mechanism for Security and Privacy Under Healthcare System With RFID Application)

  • 김정태
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2012년도 추계학술대회
    • /
    • pp.154-156
    • /
    • 2012
  • This paper presents a user authentication scheme for healthcare application using wireless medical sensor networks, where wireless medical sensors are used for patients monitoring. These medical sensors' sense the patient body data and transmit it to the professionals (e.g., doctors, nurses, and surgeons). Since, the data of an individual are highly vulnerable; it must ensures that patients medical vital signs are secure, and are not exposed to an unauthorized person. In this regards, we have proposed a user1 authentication scheme for healthcare application using medical sensor networks. The proposed scheme includes: a novel two-factor professionals authentication (user authentication), where the healthcare professionals are authenticated before access the patient's body data; a secure session key is establish between the patient sensor node and the professional at the end of user authentication. Furthermore, the analysis shows that the proposed scheme is safeguard to various practical attacks and achieves efficiency at low computation cost.

  • PDF