• Title/Summary/Keyword: Medial surface

Search Result 209, Processing Time 0.021 seconds

Anatomical Studies on the Skeleton of Thoracic Limb of Korean Native Goat (한국재래산양의 전지골격에 관한 해부학적 연구)

  • Kim, Jin-sang;Lee, Heung-shik S.;Lee, In-se
    • Korean Journal of Veterinary Research
    • /
    • v.27 no.2
    • /
    • pp.167-183
    • /
    • 1987
  • The anatomical structure of the Skeleton of thoracic limb of thirty-one adult Korean native goats(body weight: 14~17kg) was observed after skeletal preparation, and the osteometry was performed in each bone. The results were as follows; 1. The thoracic limb of the Korean native goat was composed of scapula, humerus, radius, ulna, carpal bones, metacarpal bones, phalanges and sesamoid bones. 2. The scapula was flat and triangular in shape. There were no distinct tuber of spine and acromion in the spine. The subscapular fossa was deep and triangular in shape and the vertebral border was sigmoid form. The coracoid bone was formed as the coracoid process at the medial aspect of the supraglenoid tubercle but the clavicle wa.s not observed. The left and right scapular indexes were 57.92 and 58.31 and the glenoid cavity indexes were 89.23 and 86.82, respectively. 3. The greater tubercle of the humerus was devided into cranial and caudal parts. The third tubercle was observed and the face for the infraspinatus muscle was rectangular form. The left and right humerus indexes were 32.44 and 32.63, the head indexes were 94.13, 96.62 and the trochlear-epidondyle indexes were 67.32 and 65.81, respectively. 4. The radius and ulna were fused entirely except at the broad proximal and narrow distal interosseous spaces. The ulna was longer than the radius, and its reduced body and distal end were fused at the caudomedial surface of the radius. 5. The carpal bones were six in number. There were radial, intermediate, ulnar, accessory, second-third and fourth carpal hones in carpal bones. 6. The metacarpal bone was composed of a large metacarpal bone resulted from the fusion of the third and fourth metacarpal bones, and there was a metacarpal tubercle at the dorsolateral part of the proximal end. There were no vestiges of the second and fifth metacarpal bones. 7. The digits were composed of third and fourth digits and each digit was composed of the proximal, middle and distal phalanges. 8. The sesamoid bones were six in number. There were two at the fetlock joint and one at the coffine joint palmarly in each digit. 9. The ratios of the lengths among the scapula, humerus, antebrachium and metacarpal bone were 1.42 : 1.47 : 1.77 : 1.00 in the left and 1.42 : 1.45 : 1.77 : 1.00 in the right, respectively.

  • PDF

Effect of Different Heel Plates on Muscle Activities During the Squat (스쿼트 동작 시 발뒤꿈치 보조물 경사각에 따른 하지근과 척추기립근의 근육활동 비교)

  • Chae, Woen-Sik;Jeong, Hyeun-Kyeong;Jang, Jae-Ik
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.2
    • /
    • pp.113-121
    • /
    • 2007
  • The purpose of this study was to determine the effect of three different plates($0^{\circ}$, $10^{\circ$}, $20^{\circ}$)under heels on the lower limb muscles and erector spinae during squat exercise. Ten high school korean traditional wrestling players(age: $18.5{\pm}0.7$, weight: $1972.2{\pm}128.5N$, height: $177.8{\pm}6.0cm$, weight of barbell: $1004.5{\pm}132.4N$) performed squat exercise using three different tilting plates under heels at a cadence of 40beats/sec with 80% one repetition maximum load. Surface electrodes were placed on the participants' left and right erector spinae, and rectus femoris, vastus medialis, vastus lateralis, tibialis anterior, biceps femoris, medial gastrocnemius, and lateral gastrocnemius in the right lower extremity. One S-VHS camcorder(Panasonic AG456, 60fields/s) was placed 10m to the side of the participant. To synchronize the video and EMG data, a synchronization unit was used for this study. Average and Peak IEMG values were determined for each participant. For each variable, a one-way analysis of variance was used to determine whether there were significant differences among three different tilting plates under heels. When a significant difference was found in plates type, post hoc analyses were performed using the Tukey procedure. A confidence level of p<.05 was used to determine statistical significance. As a result of this study, maximum nEMG values of the tibialis anterior in $0^{\circ}$ plates was significantly higher than the corresponding values for the other plates during the knee extension. This increased activation in the tibialis anterior muscle indicates an increase in displacement of center of gravity of body. It is very likely that additional muscle activation are needed to stop the forward and backward movement. The results also showed that muscular activities of quadriceps femoris and erector spinae were decreased with increasing angle of plates. This suggests that increasing angle of plate may help to sustain the balance and posture of squat exercise. It is considered that very few significant differences were found among three different plates($0^{\circ}$, $10^{\circ}$, $20^{\circ}$) since elite players with much experience in squat exercise, were chosen as a participant of this study. In order to obtain meaningful results regarding the tilting angle of heel plates in squat exercise, kinetic and 3D kinematic analysis will be needed in the future study.

The Effects of Wearing Roller Shoes on Muscle Activity in The Lower Extremity During Walking (롤러신발과 일반신발의 착용 후 보행 시 하지근의 근전도 비교)

  • Chae, Woen-Sik;Lim, Young-Tae;Lee, Min-Hyung;Kim, Jung-Ja;Kim, Youn-Joung;Jang, Jae-Ik;Park, Woen-Kyoon;Jin, Jae-Hong
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.3
    • /
    • pp.137-148
    • /
    • 2006
  • The purpose of this study was to compare muscle activity in the lower extremity during walking wearing jogging and roller shoes. Twelve male middle school students (age: 15.0 yrs, height 173.7 cm, weight 587.7 N) who have no known musculoskeletal disorders were recruited as the subjects. Seven pairs of surface electrodes (QEMG8, Laxtha Korea, gain = 1,000, input impedance >$1012{\Omega}$, CMMR >100 dB) were attached to the right-hand side of the body to monitor the rectus femoris (RF), vastus medialis (VM), vastus lateralis (VL), biceps femoris (BF), tibialis anterior (TA), and medial (GM) and lateral gastrocnemius (GL) while subjects walked wearing roller and jogging shoes in random order at a speed of 1.1 m/s. An event sync unit with a bright LED light was used to synchronize the video and EMG recordings. EMG data were filtered using a 10 Hz to 350 Hz Butterworth band-passdigital filter and further normalized to the respective maximum voluntary isometric contraction EMG levels. For each trial being analyzed, five critical instants and four phases were identified from the recording. Averaged IEMG and peak IEMG were determined for each trial. For each dependent variable, paired t-test was performed to test if significant difference existed between shoe conditions (p<.05). The VM, TA, BF, and GM activities during the initial double limb stance and the initial single limb stance reduced significantly when going from jogging shoe to roller shoe condition. The decrease in EMG levels in those muscles indicated that the subjects locked the ankle and knee joints in an awkward fashion to compensate for the imbalance. Muscle activity in the GM for the roller shoe condition was significantly greater than the corresponding value for the jogging shoe condition during the terminal double limb stance and the terminal single limb stance. Because the subjects tried to keep their upper body weight in front of the hip to prevent falling backward, the GM activity for the roller shoe condition increased. It seems that there are differences in muscle activity between roller shoe and jogging shoe conditions. The differences in EMG pattern may be caused primarily by the altered position of ankle, knee, and center of mass throughout the walking cycle. Future studies should examine joint kinematics during walking with roller shoes.

The Comparative Analysis of EMG Activities on the Lower Limb Muscles during Power Walking and Normal Walking (파워보행과 일반보행 시 하지근의 근전도 비교 분석)

  • Gi, Se-Joon;Chae, Woen-Sik;Kang, Nyeon-Ju;Jang, Jae-Ik;Yoon, Chang-Jin
    • Korean Journal of Applied Biomechanics
    • /
    • v.18 no.4
    • /
    • pp.125-133
    • /
    • 2008
  • The purpose of this study was to compare EMG activities on the lower limb muscles during power walking and mormal walking. Seventeen subjects who have no known musculoskeletal disorders performed walking exercise at a cadence of 140 beats/min. After surface electrodes were attached to rectus femoris, vastus medialis, vastus lateralis, biceps femoris, tibialis anterior, medial gastrocnemius, averageed IEMG and peak IEMG, were measured. The result showed that the power walking did influence the averaged IEMG and peak IEMG. The EMG activity of the quadriceps during power walking was significantly higher than the corresponding values in normal walking during most phases. The averaged IEMG and peak IEMG of gastrocnemius muscles at the end of the double limb stance increased significantly when going from normal walking to power walking. The results indicate that power walking had greater effect on EMG activities on the lower limb muscles and demonstrate that the wide range of benefits can be obtained from power walking in respect to health and fitness. This study suggests that power walking has the potential to improve aerobic fitness and assist in weight management.

Anatomical Observation on Components Related to Foot Gworeum Meridian Muscle in Human

  • Park, Kyoung-Sik
    • The Journal of Korean Medicine
    • /
    • v.32 no.3
    • /
    • pp.1-9
    • /
    • 2011
  • Objectives: This study was carried out to observe the foot gworeum meridian muscle from a viewpoint of human anatomy on the assumption that the meridian muscle system is basically matched to the meridian vessel system as a part of the meridian system, and further to support the accurate application of acupuncture in clinical practice. Methods: Meridian points corresponding to the foot gworeum meridian muscle at the body surface were labeled with latex, being based on Korean standard acupuncture point locations. In order to expose components related to the foot gworeum meridian muscle, the cadaver was then dissected, being respectively divided into superficial, middle, and deep layers while entering more deeply. Results: Anatomical components related to the foot gworeum meridian muscle in human are composed of muscles, fascia, ligament, nerves, etc. The anatomical components of the foot gworeum meridian muscle in cadaver are as follows: 1. Muscle: Dorsal pedis fascia, crural fascia, flexor digitorum (digit.) longus muscle (m.), soleus m., sartorius m., adductor longus m., and external abdominal oblique m. aponeurosis at the superficial layer, dorsal interosseous m. tendon (tend.), extensor (ext.) hallucis brevis m. tend., ext. hallucis longus m. tend., tibialis anterior m. tend., flexor digit. longus m., and internal abdominal oblique m. at the middle layer, and finally posterior tibialis m., gracilis m. tend., semitendinosus m. tend., semimembranosus m. tend., gastrocnemius m., adductor magnus m. tend., vastus medialis m., adductor brevis m., and intercostal m. at the deep layer. 2. Nerve: Dorsal digital branch (br.) of the deep peroneal nerve (n.), dorsal br. of the proper plantar digital n., medial br. of the deep peroneal n., saphenous n., infrapatellar br. of the saphenous n., cutaneous (cut.) br. of the obturator n., femoral br. of the genitofemoral n., anterior (ant.) cut. br. of the femoral n., ant. cut. br. of the iliohypogastric n., lateral cut. br. of the intercostal n. (T11), and lateral cut. br. of the intercostal n. (T6) at the superficial layer, saphenous n., ant. division of the obturator n., post. division of the obturator n., obturator n., ant. cut. br. of the intercostal n. (T11), and ant. cut. br. of the intercostal n. (T6) at the middle layer, and finally tibialis n. and articular br. of tibial n. at the deep layer. Conclusion: The meridian muscle system seemed to be closely matched to the meridian vessel system as a part of the meridian system. This study shows comparative differences from established studies on anatomical components related to the foot gworeum meridian muscle, and also from the methodical aspect of the analytic process. In addition, the human foot gworeum meridian muscle is composed of the proper muscles, and also may include the relevant nerves, but it is as questionable as ever, and we can guess that there are somewhat conceptual differences between terms (that is, nerves which control muscles in the foot gworeum meridian muscle and those which pass nearby) in human anatomy.

Electromyographic Activities of Lower Leg Muscles During Static Balance Control in Normal Adults (정상성인에서 정적 균형 제어 시 다양한 조건에 따른 하퇴 근육 활성도의 특성)

  • Woo, Young-Keun;Park, Ji-Won;Choi, Jong-Duk;Hwang, Ji-Hye;Kim, Yun-Hee
    • Physical Therapy Korea
    • /
    • v.11 no.2
    • /
    • pp.35-45
    • /
    • 2004
  • The purpose of this study was to investigate the correlation and characteristics between electromyographic (EMG) activities of lower leg muscles and the posturographic assessment of static balance control in normal adults. Twenty-four young, healthy adults(12 males, 12 females) participated in the study. Center of pressure (COP) parameters were obtained using force platform as total path distance, total sway area, X mean frequency and Y mean frequency for 20 seconds in the following conditions: (1) comfortable standing with eyes opened or closed, (2) uncomfortable standing (feet together) with eyes opened or closed, (3) virtual moving surround delivered using Head mount display (HMD) with four different moving patterns. The virtual moving patterns consisted of close-far, superior-inferior tilting (pitch), right-left tilting (roll), and horizontal rotation (yaw) movements. Surface electromyographic activites were recorded on the tibialis anterior, peroneus longus, medial and lateral heads of gastrocnemius muscles under each condition. Correlation between the posturographic measures and EMG activities were evaluated. Total path distance and total sway area of COP were significantly increased during uncomfortable standing. EMG activity of tibialis anterior was significantly more during uncomfortable standing and virtual moving surround stimulation than during comfortable standing. Total path distance and sway area of COP during comfortable standing with closed eyes showed significant positive correlation with the EMG activities of the lateral head of gastrocnemius muscle. Total path distances and total sway area of COP during muscle. Total path distances and total sway area of COP during presentation of virtual moving surround also had significant positive correlations with EMG activities of the lateral head of gastrocnemius muscle under close-far movement.

  • PDF

Comparative Analysis of Muscle Activity and Ground Reaction Force between Skilled and Unskilled Player during a Free Throw (농구 자유투 동작 시 숙련자 및 미숙련자의 근전도 및 지면 반력 분석)

  • Gu, Hyung-Mo;Chae, Woen-Sik;Kang, Nyeon-Ju;Yoon, Chang-Jin;Jang, Jae-Ik
    • Korean Journal of Applied Biomechanics
    • /
    • v.19 no.2
    • /
    • pp.347-357
    • /
    • 2009
  • The purpose of this study was to compare EMG and GRF during a free throw. Seven pairs of surface electrodes were attached to the right-hand side of the body to monitor the flexor carpi radialis (FC), extensor carpi radialis longus (EC), biceps brachii (BB), triceps brachii (TB), rectus femoris (RF), tibialis anterior (TA) and medial gastrocnemius (GM). GRF data from two force platform were collected during a free throw. The results showed that the muscle activities in the unskilled group must be highly activated prior to the moment of release. This means that a skilled participant can shoot a free throw more efficiently while producing less muscle activeness than an unskilled participant. The DCP of unskilled group in the medio-lateral direction were greater than the corresponding values in skilled group. This showed that the unskilled group were not able to shoot the free throws stably. Thus, when a teacher or instructor teaches students how to shoot free throw, it is considered that the teacher show the learner how to use not only the upper limbs but also lower limbs on the basis of the efficent connecting movement and the flexibility in a stable procedure.

Efficacy of Ilizarov External Fixation and Autologous Bone Grafting for Performing Arthrodesis on the Ankle Arthropathy with Risk Factors (불유합의 위험 인자를 가진 족관절 병변에 시행한 족관절 유합술로서 Ilizarov 외고정 기구 장착술 및 자가골 이식술의 유용성)

  • Lee, Yong-Sik;Nam, Il-Hyun;Lee, Tae-Hun;Ahn, Gil-Yeong;Lee, Yeong-Hyeon;Lee, Hee-Hyung;Hwang, Sung-Hyun
    • Journal of Korean Foot and Ankle Society
    • /
    • v.23 no.4
    • /
    • pp.189-195
    • /
    • 2019
  • Purpose: The aim of this study is to evaluate if the Ilizarov external fixation procedure with axial compression can help to obtain fusion across the ankle joint in patients with a high risk of nonunion. Materials and Methods: From January 2006 to December 2015, the study reviewed 17 patients who underwent ankle arthropathy with a high risk of nonunion and who underwent ankle fusion using the Ilizarov external fixator with axial compression and auto bone grafting. After the lateral surface of the ankle joint was exposed through a lateral trans-fibular approach, massive removal of the articular cartilage and excision of any loose or avascular bone were done. With the cortical bone harvested from the pelvis as corticocancellous bone blocks, we inserted the two cortical blocks longitudinally into the anterior and posterior part of the free ankle space from lateral to medial to make the rectangular chamber to fill the cancellous bones. After the Ilizarov external fixator was equipped, we tightened the frame by 5 mm to compress the bone graft space. We accessed the American Orthopaedic Foot and Ankle Society (AOFAS) AnkleHindfoot score both preoperatively and postoperatively. Results: The average age at the time of operation was 63.4 years (range, 47~78 years). The mean frame time was 17.4 weeks (range, 15~23 weeks). The average follow-up period was 3.7 years (range, 2~6 years). Osseous fusion was obtained in 15 patients (88.2%). There were two stable pseudarthroses among the rheumatoid arthritis patients, and we continued their follow-up. The mean AOFAS AnkleHindfoot score improved from 48.5 to 73.7 points. Conclusion: Ankle arthrodesis using the Ilizarov external fixation with axial compression and auto bone grafting on the ankle arthropathy that had difficult conditions to achieve union is considered one of the useful methods with a correspondingly low incidence of complications.

The Influence of Angle Change of the Forefoot's Adhesive Outsole Designs on the Electromyographic Activity of the Erector Spinae and Selected Lower Limb Muscles during Downhill Walking (내리막 보행시 발 전족부 부착형 아웃솔의 각도 변화가 척추기립근과 하지근의 근활성도에 미치는 영향)

  • Lee, Haeng-Seob;Chae, Woen-Sik;Jung, Jea-Hu;Kim, Dong-Soo;Lim, Young-Tae;Jang, Jea-Ik
    • Korean Journal of Applied Biomechanics
    • /
    • v.24 no.2
    • /
    • pp.139-149
    • /
    • 2014
  • The purpose of this study was to evaluate the effect of angle change of forefoot's adhesive outsole on the electromyographic activity (EMG) of the erector spinae and selected lower limbs muscle during downhill walking over $-20^{\circ}$ ramp. Thirteen male university students (age: $25.4{\pm}3.9$ yrs, height: $176.2{\pm}5.1$ cm, weight: $717.4{\pm}105.0$ N) who have no musculoskeletal disorder were recruited as the subjects. To assess the myoelectric activities of selected muscles, six of surface EMG electrodes with on-site pre-amplification circuitry were attached to erector spinae (ES), rectus femoris (RF), biceps femoris (BF), tibialis anterior (TA), lateral gastrocnemius (LG), and medial gastrocnemius (MG). To obtain maximum EMG levels of the selected muscles for normalization, five maximum effort isometric contraction were performed before the experimental trials. Each subject walked over $0^{\circ}$ and $20^{\circ}$ ramp with three different forefeet's EVA outsole (0, 10, $20^{\circ}$) in random order at a speed of $1.2{\pm}0.1$ m/s. For each trial being analyzed, five critical instants and four phases were identified from the recording. The results of this study showed that the average muscle activities of MG and LG decreased in $20^{\circ}$ shoes compared to $0^{\circ}$ and $10^{\circ}$ ones in the initial double limb stance (IDLS). In initial single limb stance (ISLS) phase, the average muscle activities of ES increased with the angle of forefoot's adhesive outsole, indicating that the increment of shoes' angle induce upper body to flex anteriorly in order to maintain balance of trunk. In terminal double limb stance (TDLS) phase, average muscle activities of TA significantly increased in $20^{\circ}$ outsole compared to $0^{\circ}$ and $10^{\circ}$ ones. There was no external forces acting on the right foot other than the gravity during terminal single limb stance (TSLS) phase, all muscles maintained moderate levels of activity.

Transareolar-Perinipple Dual Pockets Breast Augmentation (횡유륜 유두주위절개를 통한 이중포켓 유방확대술)

  • Lee, Paik Kwon;Kim, Jee Hoon;Seo, Byung Chul;Oh, Deuk Young;Rhie, Jong Won;Ahn, Snag Tae
    • Archives of Plastic Surgery
    • /
    • v.34 no.1
    • /
    • pp.93-98
    • /
    • 2007
  • Purpose: Many options are available for the incision and pocket selection in breast augmentation. Each method has its advantages and disadvantages. To leave an invisible operation scar and to achieve easier pocket dissection by the central location of the incision on the breast, we made a transareolar-perinipple incision. To overcome the disadvantages of the transareolar incision, originally advocated by Pitanguy in 1973, we modified the direction of incision line and dissection plane. Methods: To avoid the injury of 4th intercostal nerve responsible for nipple sensation, we made perinipple incision on the medial side of the nipple instead of trans-nipple incision and made the transareolar incision as 11-5 o'clock on the left side and 1-7 o'clock on the right side instead of 3-9 o'clock on both sides. To avoid the possible infection and breast feeding problem caused by the injury to the lactiferous duct, and the possible implant hernia caused by the incisions lying on a same plane of pocket dissection, we made a subcutaneous dissection just above the breast tissue medially down to the bottom of breast tissue and made a subglandular or subfascial pocket, which may avoid the injury of lactiferous duct and create different planes for skin incision and pocket dissection. Other advantages of the transareolar-perinipple incision include easier pocket dissection, less chance of hematoma, and as a result less postoperative pain because of the central location of the approach which allow finger dissection and meticulous bleeding control with direct vision, without any specialized instrument such as an endoscope or long mammary dissectors. As for pocket selection, we made dual pockets. We prefer subglandular or subfascial pocket. Also, we made a subpectoral pocket in the upper 1/4 of the pocket to add more volume on the upper part of the augmented breast, which can make aesthetically more desirable breasts in thin Asian women with small breasts. Possible disadvantages of our method are subclinical infection and scar widening, which could be overcome by meticulous operation techniques, antibiotic therapy, and intradermal tattooing. Results: From September, 2003 to August, 2005, 12 patients underwent breast augmentation using round smooth surface saline implants by our method. During the mean follow-up period of 13 months, there were no complications such as infection, hematoma, capsular contracture, and sensory change of nipple, and results were satisfactory. Conclusion: We suggest breast augmentation via transareolar-perinipple incision and dual pockets(subpectoral-subglandular or subfascial) as a valuable method in thin oriental women with small breasts.