• Title/Summary/Keyword: Medial Rotation

Search Result 104, Processing Time 0.024 seconds

Restoring blood flow to the lateral plantar artery after elevation of an instep flap or medialis pedis flap

  • Velazquez-Mujica, Jonathan;Amendola, Francesco;Spadoni, Davide;Chen, Hung-Chi
    • Archives of Plastic Surgery
    • /
    • v.49 no.1
    • /
    • pp.80-85
    • /
    • 2022
  • The instep flap and medialis pedis flap are both originate based on the medial plantar artery. The medialis pedis flap is based from the deep branch and the instep flap is based from the superficial branch. To increase the axial rotation, it is acceptable to ligate the lateral plantar artery. However, this can partially affect the blood supply of the plantar metatarsal arch. We restored the blood flow with a vein graft between the posterior tibial artery and the ligated stump. From 2012 to 2020, 12 cases of heel reconstruction, including seven instep flaps and five medialis pedis flaps, were performed with ligation of the lateral plantar artery. The stump of the lateral plantar artery was restored with a vein graft and between the posterior tibial artery and the ligated stump. Patients were followed for 18 months. Long-term results showed the vascular restoration of the lateral plantar artery remained patent demonstrated by doppler ultrasonography. Restoring blood flow to the lateral plantar artery maintains good blood supply to the toes. If the patient in the future develops a chronic degenerative disease, with microvascular complications, bypass surgery can still be performed because of the patency of both branches.

KNEE: Basic Science and Injury of Bone (슬관절 주위 글격의 기초과학 및 스포츠 손상)

  • Kim Hee-Chun
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.2 no.2
    • /
    • pp.77-81
    • /
    • 2003
  • Purpose: The biomechanics and kinematics of knee joint were reviewed in this article. And then the common sports injuries were presented. Anatomy and Kinetics: None of the pairs of bearing surfaces in the knee joint is exactly congruent This allows the knee six degrees of freedom of motion. Tibiofemoral Kinematics: In flexion and extension, the axis of motion is not perpendicular to the medial-lateral plane of the joint, nor is it perpendicular to the axis of longitudinal rotation. This results in coupled varus angulation and internal rotation with flexion and in valgus angulation and external rotation with extension. Patellofemoral Articulation: Loads across the patellofemoral joint are indirectly related to the angle of knee flexion and directly related to the force generated within the quadriceps mechanism. Fractures of the Patella: Nonoperative treatment is indicated if the extensor mechanism is intact and if displacement of fragment is minimal. The specific type of internal fixation depends on the fracture pattern. It is important to repair retinaculum. Acute and Recurrent Patellar Instability: The degree of dysplasia and the extent of the instability play a large part in determining the success of nonoperative treatment. Patients who experience recurrent dislocations and patients with major anatomic variations require surgery to minimize their instability. Sports Injuries in School-age Atheletes: Patellar pain in young athletes groups a number of conditions, including Idiopathic Adolescent Anterior Knee Pain, Osgood- Schlatter Disease, and Sinding-Larsen-Johansson Disease.

  • PDF

Three-Dimensional Video Analysis of the Gate Patterns in Normal Children and Hemiplegic Children with Cerebral Palsy (정상아와 편마비 뇌성마비아의 삼차원 보행분석)

  • Lee Jin-Hee;Bae Sung-Soo;Kim Chung-Sun
    • The Journal of Korean Physical Therapy
    • /
    • v.9 no.1
    • /
    • pp.127-145
    • /
    • 1997
  • The purpose of this study wa9 to analyse the gait patterns of two female children with hemiplegic cerebral palsy by using the three-dimensional video motion analysis technique. Case 1 has mild spastic hemiplegia on the right side while Case 3 has moderate spastic hemiplegia on the left side. A group of 10, normal female children of the same age(7-8 years old) were selected as the control group for comparison. Time and distance variables as well as the Center of Mass displacement, and the pelvic and joint motions in three anatomical planes were analysed for this purpose. The following observations were made through the analysis : Case 1 revealed an asymmetrical gait pattern in which the step length of the unaffected side was shorter than that of the affected side, which wan a result of the effort to minimize loading on the affected leg by shortening the swing phase of the unaffected leg. Case 1 scored similar phase ratios, cadence and walking velocity to the normal group. A slight posterior tilt of the pelvis was observed throughout the gait cycle. Less hip and knee flexion than the normal group was observed, and demonstrated hyperextension of the knee in the terminal stance phase. The main problem in case 1 originated from the insufficient dorsiflexion of the affected foot during the swing phase. Therefore, Case 1 has difficulty with foot clearance in the swing phase. Usually, this is compensated for by using exessive hip abduction and medial rotation in conjuction with trunk elevation as well as increased vortical displacement of the center of mass. Case 1 revealed a foot-flat initial contact pattern. Case 2 was characterized by a consistent retraction ef the affected aide of the body througout the gait cycle, As a result, an asymmetrical gait pattern with increased stance phase ratios of the unaffected side was observed. In spite of this the step lengths of both sieds were similar. Case 2 scored lower cadence and walking speed than the normal group with lower gait stability. The main problem in Case 2 originated from an excessive plantaflexion of the affected foot which, in turn, rebutted in high hip and knee flexion. Hyperextension of the knee was observed at mid-stance, and execessive anterior tilt of the pelvis throughout the gait cycle was noticed. A gait pattern with high hip abduction and medial circumduction was maintained for the stability in the stance phase and foot clearance in the swing phase. Case 2 revealed a forefoot-contact initial contact pattern.

  • PDF

Correlation Between Pectoralis Minor, Shoulder Mobility and Neck Range of Motion on Rounded Shoulder Posture for Life-Care Increase in Women University Student (여대생의 라이프 케어 증진을 위한 둥근 어깨 자세의 작은가슴근, 어깨가동성과 목 관절가동범위의 상관연구)

  • Seo, Tae-Hwa;Kim, Min-Sun;Jeong, Yeon-Woo
    • Journal of Korea Entertainment Industry Association
    • /
    • v.13 no.5
    • /
    • pp.239-246
    • /
    • 2019
  • This study aims to examine the correlation between pectoralis minor, shoulder mobility, and neck range of motion on rounded shoulder posture for Life-care increase in Women university student. The 80 female adults with rounded shoulder posture were selected for this study. Measurements of shoulder height were obtained by measuring the rounded shoulder posture using a caliper. To measure the length of pectoralis minor, a tape measure was used to measure from the point where the 4th rib and sternum meets to the inferior medial side of coracoid process. Shoulder mobility was measured by holding fists in both hands, then raising one side of the elbow until the palm on that side can be placed on the back, while lowering the other side of the elbow until the back of the hand on that side can be placed on the back. Neck range of motion was used to measure the neck movement including the flexion and the extension, lateral flexion to the right or to the left, and rotation to the right or to the left. The results of this study showed that there are significant negative correlations between pectoralis minor index, shoulder mobility, and neck range of motion in rounded shoulder posture(p<0.05). From these results, in female students with rounded shoulder, the lateral flexion of the neck to the left decreased as the left shoulder mobility increased, the neck extension decreased as the right pectoralis minor shortened, and the rotation of the neck to the left decreased as the left shoulder mobility increased.

Improvement of Motor Behavior of Parkinson′s Disease Animal Model by Nurr1-Transfected Human Embryonic Stem Cells.

  • Lee, Chang-Hyun;Cho, Hwang-Yoon;Kil, Kwang-Soo;Lee, Gun-Soup;Yoon, Ji-Yeon;Lee, Young-Jae;Kim, Eun-Young;Park, Se-Pill;Lim, Jin-Ho
    • Proceedings of the Korean Society of Developmental Biology Conference
    • /
    • 2003.10a
    • /
    • pp.103-103
    • /
    • 2003
  • The purpose of this study is to evaluate an efficacy of in vitro differentiated human embryonic stem (hES, MB03) cells expressing Nurr1 in relief of symptomatic motor behavior of Parkinson's disease (PD) animal models MB03 was genetically modified to express Nurr1 protein and was induced to differentiate according to 2-/4+ protocol using retinoic acid and ascorbic acid. The differentiation-induced cells were selected for 10 to 20 days thereafter in N2 medium. Upon selection, cells expressing GFAP, TH, or NF200 were 38.8%, 11%, and 20.5%, respectively. in order to examine therapeutic effects of the differentiated cells in PD animal model, rats were unilaterally lesioned by administration of 6-kydroxydopamine HCI (6-OHDA) into medial forebrain region (MFB, AP -4.4 mm, ML 1.2 mm, DV 78 mm with incision bar set at -2.4 mm), as a reference to bregma and the surface of the skull. Confirmation of successful lesion by apomorphine-induced rotational behavior, differentiated cells were transplanted into the striatum (AP 1.0, ML 3.5, DV -5.0; AP 0.6, ML 2.5, DV -4.5). Improvements of asymmetric motor behavior by the transplantation were examined every two weeks after the surgery. In two weeks, numbers of rotation by the experimental rats were $-14.8 \pm 33.9%$ (P<0.05) of the number before transplantation, however, the ratio increased slightly to $13.6 \pm 56.3%$ in six weeks. In contrast, the ratio of sham-grafted animals ranged from 112.3+8.5% to 139.2+28.9% during the examination. Immunohistochemical studies further confirmed the presence, survival, migration, and expression of TH of the transplanted human cells.

  • PDF

Development and validation of a computational multibody model of the elbow joint

  • Rahman, Munsur;Cil, Akin;Johnson, Michael;Lu, Yunkai;Guess, Trent M.
    • Advances in biomechanics and applications
    • /
    • v.1 no.3
    • /
    • pp.169-185
    • /
    • 2014
  • Computational multibody models of the elbow can provide a versatile tool to study joint mechanics, cartilage loading, ligament function and the effects of joint trauma and orthopaedic repair. An efficiently developed computational model can assist surgeons and other investigators in the design and evaluation of treatments for elbow injuries, and contribute to improvements in patient care. The purpose of this study was to develop an anatomically correct elbow joint model and validate the model against experimental data. The elbow model was constrained by multiple bundles of non-linear ligaments, three-dimensional deformable contacts between articulating geometries, and applied external loads. The developed anatomical computational models of the joint can then be incorporated into neuro-musculoskeletal models within a multibody framework. In the approach presented here, volume images of two cadaver elbows were generated by computed tomography (CT) and one elbow by magnetic resonance imaging (MRI) to construct the three-dimensional bone geometries for the model. The ligaments and triceps tendon were represented with non-linear spring-damper elements as a function of stiffness, ligament length and ligament zero-load length. Articular cartilage was represented as uniform thickness solids that allowed prediction of compliant contact forces. As a final step, the subject specific model was validated by comparing predicted kinematics and triceps tendon forces to experimentally obtained data of the identically loaded cadaver elbow. The maximum root mean square (RMS) error between the predicted and measured kinematics during the complete testing cycle was 4.9 mm medial-lateral translational of the radius relative to the humerus (for Specimen 2 in this study) and 5.30 internal-external rotation of the radius relative to the humerus (for Specimen 3 in this study). The maximum RMS error for triceps tendon force was 7.6 N (for Specimen 3).

Intra- and Inter-rater Reliabilities of Infrasternal Angle Measurement

  • Kim, Moon-Hwan;Weon, Jong-Hyuck
    • The Journal of Korean Physical Therapy
    • /
    • v.27 no.3
    • /
    • pp.154-158
    • /
    • 2015
  • Purpose: The purpose of this study was to propose a new reference point for measurement of the infrasternal angle and to investigate the intra- and inter-rater reliabilities of infrasternal angle measurement using photographs. Methods: Twenty-four healthy male college students participated as subjects in this study. Photographs were taken of subjects in two postures, one standing with the shoulders relaxed and one standing with the shoulders at $150^{\circ}$ abduction. All photographs were analyzed using Image J software. Raters used the photographs to measure the infrasternal angle between the xiphoid process, the medial margin of rib and navel on the right and left sides. The reliability of the infrasternal angle measurement was assessed by means of intraclass correlation coefficients [ICC (3,1)]. The level of statistical significance was set at p<0.05. Results: The intra- and inter-rater reliabilities of the infrasternal angle measurement for the right side at rest were excellent (ICC=0.866 and 0.813, respectively), as were those for the left side at rest (ICC=0.919 and 0.846, respectively). At $150^{\circ}$ shoulder abduction, the intra- and inter-rater reliabilities for measurement of the infrasternal angle on the right side were excellent (ICC=0.972 and 0.778, respectively), as were those for the left side (ICC=0.914 and 0.826, respectively). Conclusion: These findings suggest that this technique can be successfully used to measure the infrasternal angle, thus suggesting a new reference point for determining the length of the internal oblique and external oblique muscles in clinical situations.

Postural Control During Virtual Moving Surround Stimulation in Patients with Brain Injury (뇌기능 장애 환자의 가상 환경 움직임(Virtual Moving Surround) 자극에 따른 자세 균형 제어)

  • 김연희;최종덕;이성범;김종윤;이석준;박찬희;김남균
    • Science of Emotion and Sensibility
    • /
    • v.5 no.4
    • /
    • pp.67-75
    • /
    • 2002
  • The purpose of this study is to assess the ability of balance control in virtual moving surround stimulation using head mount display (HMD) device and force platform in patients with brain injury. Fifteen patients with stroke (mean age 54.47 yrs) and fifteen healthy normal persons participated. COP parameters were obtained total path distance, frequency of anterior-posterior and medial-lateral component by FFT analysis, weight-spectrum analysis in the two different conditions; (1) during comfortable standing with opened or closed eyes, (2) during virtual moving surround stimulation delivered using HMD with four different moving pattern. Moving patterns consisted of close-far, superior-inferior lilting (pitch) , right-left tilting (roll) and horizontal rotation (yaw) movement. In all parameters, the test-retest reliability was high. Also, the construct validity of virtual moving surround stimulation was excellent (p<0.05). A posturographic balance assessment system equiped with virtual moving surround stimulation using HMD is considered clinically useful in evaluation of balance control in patients with brain injury.

  • PDF

Changes in Balance Ability and Muscle Thickness of the Transverse Abdominis and Multifidus of Elderly Females after Eight Weeks of the Lumbar Stabilization Exercise (8주간의 요부안정화운동 시 여성노인의 균형능력 및 복횡.다열근 두께의 변화)

  • Ko, Dae-Sik;Kim, Gwon-Yeong;Lee, Chul-Gab;Lee, Kyoung-Il;Kim, Chan-Kyu;Jeong, Dae-In
    • Korean Journal of Applied Biomechanics
    • /
    • v.19 no.4
    • /
    • pp.689-696
    • /
    • 2009
  • This study was conducted to examine the effects of the lumbar stabilization exercise (LSE) on fall prevention in elderly females (n = 21) by measuring changes in the isometric strength, multifidus, transverse abdominis muscle thickness, and posture stability index. The strength of isometric contraction was measured by the 3-D Pegasus system ; the thickness of the multifidus and transverse abdominis were measured by using Sonoace 6000C, and the posture stability index was measured using a computerized Biodex Balance System SD apparatus analysis. These results lead us to the conclusion that flexion and extension, left rotation on strength of isometric contraction, and thickness of the transverse abdominis (when released) statically increased. Overall, the anterior/posterior and medial/lateral elements in the posture stability index statically decreased, Consequently, the LSE should the prevent falls in elderly females.

Study on Noise Reduction by Optimizations of In-line Duct Flow (덕트의 유로 최적화를 통한 소음저감 연구)

  • Han, Jae-Oh;Lee, Soo-Young;Mo, Jin-Yong;Lee, Jai-Kwon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.803-808
    • /
    • 2006
  • This paper was a study about noise reduction through flow stabilization in duel using experimental method and numerical analysis at the same time. To determine the fan's type three kinds of fans(axial fan, centrifugal fan, and axial fan with centrifugal type) was examined to investigate the suitability for duct. As a result, under the equal number of rotation 2000 RPM, performance of an axial fan with centrifugal type was the most superior by 55dBA at 4.3CMM among other fans. After this, analyzed the results of the numerical analysis to find out the optimum design of pitch angle such as $0^{\circ},\;10^{\circ},\;15^{\circ}\;and\;20^{\circ}$. The intensity of turbulence was low when pitch angle was $15^{\circ}$ and air volume became peak by 5.08 CMM. It was observed that axis component of velocity increased gradually when pitch angle increased from $0^{\circ}\;to\;20^{\circ}$. Finally, designed the shapes of D/S(Down Stream) in duct that agreed inlet angle($\delta$) of stationary blades with pitch angle($\beta$) of axial fan with centrifugal type and derived flow to duct medial, and changed the shape of motor-mount to reduce occurance of unstable vortex in tip of impeller, and embodied noise reduction and improvement of air flow rate through flow stabilization.

  • PDF