• 제목/요약/키워드: Mechanical power test

검색결과 1,286건 처리시간 0.031초

파워 스티어링 기어의 밸브 밸런스 테스트 장비 개발 (Development of Valve Balance Test Equipment for Power Steering Gear)

  • 고석조;박민규;원태현;김현식;김갑혁
    • 한국기계기술학회지
    • /
    • 제13권1호
    • /
    • pp.65-71
    • /
    • 2011
  • Steering gear is the part of an automobile that change circular movement of steering wheel to lateral movement of rack to change driving direction. This can be classified with manual and power steering gear. Manual steering gear is operated only with human power while power steering gear use oil pressure support. These days power steering gear is more common to almost of the car. Recently a korean company manufactures a speed sensitive power steering which provide variable steering feel depend on the speed of car. The Broens company of Australia produces and exports the test equipments for the manufacture of power steering valves and assemblies to major vehicle manufactures. Some korean companies imported the test equipments from Australia, thus increasing the cost. The purpose of this study is development of the valve balance test equipment to measure the valve torque of the power steering gear. This study designed and manufactured the valve balance test equipment to take hold of the power steering valve using CAE analysis. In order to evaluate the performance of the developed valve balance test equipment, the R&R tests have been conducted.

180kV HVDC 해저케이블 기계적/전기적 특성 평가 (Mechanical and Electrical Performance of 180kV HVDC Submarine Cable System)

  • 김남열;이태호;지봉기;이상진;김정년;전승익;윤희석;정수길;강채홍;안용호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.616-618
    • /
    • 2007
  • This paper describes the mechanical and electrical test on HVDC submarine cable, Flexible Repair Joint and termination for 180kV. This HVDC submarine cable was manufactured using LS cable's unique skill and would be applied the HVDC submarine cable system in korea. The performance test consist of mechanical test and electrical test. The tensile bending test and tensile test was done as the mechanical test and Electrical test is DC voltage and Impulse test. The tensile bending test carried out 6 times(double of specified times) for maximum reliability. The DC test voltage is $\pm$400kV/1hr. We estimate the lower limit of DC breakdown voltage is 600kV. The impulse test voltage is $\pm$800kV/10shots. The type of developed cables is the MI type. Its insulation consist of paper tapes impregnated with a high viscosity oil. The development of new HVDC cable is available for HVDC underground or submarine power transmission. The developed HVDC cable, FRJ and termination have passed the mechanical and electrical test successfully and showed excellent performance.

  • PDF

Micro-cracks에 의한 PV 모듈의 전기적 특성 분석 (The analysis of electrical characteristics with Micro-crack in PV module)

  • 송영훈;지양근;;강기환;유권종;안형근;한득영
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 춘계학술발표대회 논문집
    • /
    • pp.25-30
    • /
    • 2011
  • In this paper, we analyzed the electrical characteristics with Micro-cracks in Photovoltaic module. Micro cracks are increasing the breakage risk over the whole value chine from the wafer to the finished module, because the wafer or cell is exposed to mechanical stress. And The solar cells have to with stand the stress under out door operation in the finished module. Here the mechanical stress is induced by temperature changes and mechanical loads from wind and snow. So, we experimentally analyze the direct impact of micro-cracks on the module power and the consequences after artificial aging. The first step, we made micro-cracks in PV module by mechanical load test according to IEC 61215. Next, PV modules applied the thermal cycling test, because micro-cracks accelerated aging by thermal cycling test, according to IEC61215. Before every test, we checked output and EL image of PV module. As the result of first step, we detected little power loss(0.9%). But after thermal cycling test increased power loss about 3.2%.

  • PDF

지중 배전케이블용 자켓 컴파운드의 특성평가 (Evaluation of Jacket Compounds for Underground Distribution Power Cables)

  • 한재홍;송일근;김동명;이재봉;정창수
    • 한국전기전자재료학회논문지
    • /
    • 제15권8호
    • /
    • pp.687-694
    • /
    • 2002
  • In order to replace the jacket material for URD power cables, the 6 kinds of polyethylene compounds were manufactured and evaluated. The characteristics of the compounds were investigated by water vapor transmission (WVT) test, thermal and mechanical test. In WVT test, all the polyethylene compounds showed the superior water resistance to conventional PVC. The molecular structure and density of polyethylene play an important role in WVT. Also, the polyethylene compounds showed the suitable characteristics in thermal and mechanical test. Especially, the linear polyethylene compounds showed the superior characteristics to LDPE ones. Due to the fillers in compounds, the abrasion resistance was decreased and the cut-through resistance was increased. From this study, it can be considered that the polyethylene compounds may be suitable to jacket material for URD power cables.

지중 케이블용 외피 컴파운드 개발 (Development of Jacket Compounds for URD Power Cables)

  • 한재홍;김주용;김동명;송일근
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 일렉트렛트 및 응용기술
    • /
    • pp.7-10
    • /
    • 2002
  • In this study, polyolefin compounds were developed and evaluated for replacing a jacket material of URD power cables. The characteristics of compounds were investigated by water vapor transmission (WVT) test and mechanical test. In WVT test, all polyolefin compounds showed the superior water resistance to conventional PVC. The molecular structure and density of polyolefin play an important role in WVT. Also, polyolefin compounds showed the suitable characteristics in mechanical test. Especially, polyolefin compounds having linear molecules showed the superior characteristics to LDPE ones. From this study, it can be considered that polyolefin compounds may be suitable to jacket material for URD power cables.

  • PDF

와이블-역승법을 이용한 기계류부품의 가속시험 방법 개발 (Development of accelerated life test method for mechanical components using Weibull-IPL(Inverse Power Law) model)

  • 이근호;김형의;강보식
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.445-450
    • /
    • 2003
  • This study was performed 10 develop the accelerated life test method using Weibull-IPL(Inverse Power Law) model for mechanical components. Weibull-IPL model is concerned with determining the assurance life with confidence level and the accelerated life test time From the relation of weibull distribution factors and confidence limit, the testing times on the no number of failure acceptance criteria arc determined. The mechanical components generally represent wear and fatigue characteristics as a failure mode. IPL based on the cumulative damage theory is applied effectively the mechanical components to reduce the testing time and to achieve the accelerating test conditions. As the actual application example, accelerated life test method of agricultural tractor transmission was described. Life distribution of agricultural tractor transmission was supposed to follow Weibull distribution and life test time was calculated under the conditions of average life (MTBF) 3,000 hours and 90% confidence level for one test sample. According to IPL, because test time call be shorten in case increase test load test time could be reduced by 482 hours when we put the load 1.1 times of rated load than 0.73 times of rated load that is equivalent load calculated by load spectrum of the agricultural tractor. This time, acceleration coefficient was 11.7.

  • PDF

고강도철근 기계적정착의 원전구조물 적용을 위한 성능평가실험 (Performance Evaluation Test for Applying the Mechanical Development of the High-Strength Reinforcing Bars to the Nuclear Power Plant Structures)

  • 이병수;방창준;임상준;김석철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 추계 학술논문 발표대회
    • /
    • pp.197-198
    • /
    • 2012
  • If the mechanical development be applied to the Nuclear Power Plant Structures instead of the standard hook development, the problem of overcrowding re-bars in the anchorage zone can be solved and the construction quality of the concrete work will be improved. But there are some problems in applying it to the NPP structures because of the restriction on the re-bar yield strength and diameter. After the performance evaluation test for the mechanical development, we can develop the new design equation of the mechanical development length in order to solve the limitation and apply it to NPP structures.

  • PDF

Experimental testing and evaluation of coating on cables in container fire test facility

  • Aurtherson, P. Babu;Hemanandh, J.;Devarajan, Yuvarajan;Mishra, Ruby;Abraham, Biju Cherian
    • Nuclear Engineering and Technology
    • /
    • 제54권5호
    • /
    • pp.1652-1656
    • /
    • 2022
  • Fire tests were conducted on cables using fire-retardant paint employed in nuclear power plants that transmit electrical power, control and instrument signals. The failure criteria of various power and control cables coated with fire retardant coating at three different coating thicknesses (~0.5 mm, 1.0 mm & 1.5 mm) were studied under direct flame test using Container Fire Test Facility (CFTF) based on standard tests for bare cables. A direct flame fire test was conducted for 10 min with an LPG ribbon burner rated at ten by fixing the cable samples in a vertical cable track. Inner sheath temperature was measured until ambient conditions were achieved by natural convection. The cables are visually evaluated for damage and the mass loss percentage. Cable functionality is ascertained by checking for electrical continuity for each sample. The thickness of cable coating on fire exposure is also studied by comparing the transient variation of inner sheath temperature along the Cable length. This study also evaluated the adequacy of fire-retardant coating on cables used for safety-critical equipment in nuclear power plants.

Development and Testing of a 10 kV 1.5 kA Mobile DC De-Icer based on Modular Multilevel Converter with STATCOM Function

  • Hu, Pengfei;Liang, Yiqiao;Du, Yi;Bi, Renming;Rao, Chonglin;Han, Yang
    • Journal of Power Electronics
    • /
    • 제18권2호
    • /
    • pp.456-466
    • /
    • 2018
  • This paper introduces the development of a de-icer based on a full-bridge modular multilevel converter (FMMC). The FMMC can generate a wide range of DC voltages owing to its modularity, scalability, and redundancy, which makes it suitable for ice-melting applications. First, operating principles and voltage ranges are analyzed when FMMC is applied as a mobile de-icer. Second, two new startup strategies, constant modulation index and constant power startup strategies, are proposed. Third, the main control strategies of the de-icer are proposed. Fourth, a novel rated-current zero-power test scheme is proposed to simplify test conditions. Finally, a 10 kV 1.5 kA mobile MMC de-icer is designed and built, and experiments are carried out to validate the proposed startup, control strategies, and rated-current zero-power test scheme.

10kW급 태양광 발전시스템의 정보 전송방식 (An Information Transmission Method of Photovoltaic Power System for 10kW Class)

  • 이현두;전세봉;이수병;김종규;류승표
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2006년도 전력전자학술대회 논문집
    • /
    • pp.228-230
    • /
    • 2006
  • This paper describes the information transmission method using communication networks between the devices in Photovoltaic Power System, and also represents the test result which carried out in the field. In this test, transmission signal waveform, polling time, response time and request/response frame were measured between the devices. The measured results show the excellent transmission characteristics.

  • PDF