• 제목/요약/키워드: Mechanical performance test

검색결과 2,606건 처리시간 0.036초

Test Results of Refrigerant R152a in a Mobile Air-Conditioning System

  • Shin, Jeong-Sub;Park, Won-Gu;Kim, Man-Hoe
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제16권2호
    • /
    • pp.44-50
    • /
    • 2008
  • This study presents test results of a mobile air-conditioning system using a potential alternative refrigerant, R152a. A series of performance tests have been carried out and cycle characteristics such as cooling capacity, energy efficiency ratio, suction and discharge pressures, and temperatures are presented, compared to those for the baseline R134a system. Tests were conducted with evaporation temperature of $5^{\circ}C$, condensation temperature of $45^{\circ}C$, subcooling temperature of $5^{\circ}C$, superheating temperature of $5^{\circ}C$, and compressor speed of 500-1500 rpm. The performance of R152a system with readjustment of an expansion valve showed better than those of R134a. The effect of oil on the pressure drop in the evaporator was also addressed.

삼차원 좌표 측정을 위한 부피 간섭계의 오차분석 및 성능평가 (Error analysis and Performance test of the Volumetric interferometer for Absolute distance measurement)

  • 이혁교;주지영;김승우
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.387-390
    • /
    • 2002
  • In this paper, we accomplish uncertainty evaluation and performance test of the volumetric interferometer using two spherical wavefronts emitted from the ends of two single mode fibers. We verify that the volumetric interferometer has the volume uncertainty of 690nm through the error analysis and it has the resolution of 0.1 0.1$\mu\textrm{m}$ for x axis which is the same order of repeatability for x axis. Also, we obtain the systematic error of $1\mu\textrm{m}$ for $60\times 60\times 20 mm^3$ working volume using self-calibration with an artifact plate.

  • PDF

이송조립기술로 제조된 나노 박막의 기계적인 특성 평가에 관한 연구 (A study on mechanical characterization of nano-thick films fabricated by transfer assembly technique)

  • 최현주;김재현;이상주;이학주
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.30-34
    • /
    • 2008
  • The transfer assembly (or transfer printing) technique is a promising method for fabricating multi-scale structures on various substrates including semiconductors and polymers, and has been applied to fabrication of flexible devices with superior performance to conventional organic flexible devices. The mechanical behaviors of the structures fabricated by the transfer assembly is a very important information for design and reliability evaluation purpose, but the measurement of the behaviors is difficult since their critical-dimensions are very tiny. In this study, Au films with nano-scale thickness were fabricated on a silicon substrate and their mechanical properties were measured using micro-tensile test. The Au films on the silicon substrate were then transferred to a PDMS substrate using the transfer assembly technique. Self-assembled monolayer (SAM) with a thiol group was used to enhance the transfer of Au films, and the mechanical behaviors were characterized using wrinkle-based test. The test results from micro-tensile and wrinkle-based test are compared to each other, and their implication to the transfer assembly technique is discussed.

  • PDF

내접형 기어펌프용 로터의 소음저감을 위한 치형 최적설계 (Optimal Design of Rotor Profile of Internal Gear Pump for Noise Reduction)

  • 배준호;배원병;주웅탁;김철
    • 대한기계학회논문집A
    • /
    • 제38권3호
    • /
    • pp.295-302
    • /
    • 2014
  • 내접형 기어펌프의 경우 내구성과 소형화의 장점을 가지고 있으나, 유량증대 및 소음저감의 성능개선이 요구되고 있다. 본 논문에서는 외부로브 형상이 다양한 곡선 조합(타원 1-인볼루트-타원 2)인 경우에 대하여 기구학적 치형 형상 관계식을 유도하고, 창성된 치형에 대해 소음에 관계된 성능인자(압력각, 유량맥동과 미끄럼률)를 예측하여 소음정도를 수치적으로 비교하였다. 또한 이론 해석을 통해 구한 치형형상과 성능인자 예측 알고리즘을 통하여 설계변수와 성능인자간의 영향도를 분석하였고, 분석 결과를 바탕으로 일정한 유량성능을 유지하면서 소음이 저감된 치형의 최적설계를 수행하였다. 해석결과를 바탕으로 제시된 치형의 최적설계에 대한 시제품 제작 및 소음 시험을 통해 설계의 타당성을 검증하였다.

가압고정 기계적이음을 활용한 프리캐스트 콘크리트 구조물의 준정적 및 진동대 실험 (Quasi-Static and Shaking Table Tests of Precast Concrete Structures Utilizing Clamped Mechanical Splice)

  • 성한석;안성룡;박시영;강현구
    • 한국지진공학회논문집
    • /
    • 제27권1호
    • /
    • pp.37-47
    • /
    • 2023
  • A new clamped mechanical splice system was proposed to develop structural performance and constructability for precast concrete connections. The proposed mechanical splice resists external loading immediately after the engagement. The mechanical splices applicable for both large-scale rebars for plants and small-scale rebars for buildings were developed with the same design concept. Quasi-static lateral cyclic loading tests were conducted with reinforced and precast concrete members to verify the seismic performance. Also, shaking table tests with three types of seismic wave excitation, 1) random wave with white noise, 2) the 2016 Gyeongju earthquake, and 3) the 1999 Chi-Chi earthquake, were conducted to confirm the dynamic performance. All tests were performed with real-scale concrete specimens. Sensors measured the lateral load, acceleration, displacement, crack pattern, and secant system stiffness, and energy dissipation was determined by lateral load-displacement relation. As a result, the precast specimen provided the emulative performance with RC. In the shaking table tests, PC frames' maximum acceleration and displacement response were amplified 1.57 - 2.85 and 2.20 - 2.92 times compared to the ground motions. The precast specimens utilizing clamped mechanical splice showed ductile behavior with energy dissipation capacity against strong motion earthquakes.

Measurement of Indoor Air Quality for Ventilation with the Existence of Occupants in Schools

  • Shin Hee-Soo;Lee Jai-Kwon;Ahn Young-Chull;Yeo Chang-Shin;Byun Sang-Hyun;Lee Jae-Keun;Kang Tae-Wook;Lee Kam-Gyu;Park Hyo-Soon
    • Journal of Mechanical Science and Technology
    • /
    • 제19권4호
    • /
    • pp.1001-1005
    • /
    • 2005
  • This paper evaluates the performance of ventilation for the removal of indoor pollutants as a function of ventilation rate and the number of occupants in a test room and school classroom. An experimental apparatus consists of a test room, a tracer gas supply system, a gas detector, and a fan for ventilation air supply with a controller. The ventilation performance is evaluated in a step-down method based on ASTM Standard E741-83 using $CO_{2}$ gas as a tracer gas in the test room of 35 $m^{3}.$ For the ventilation air flow rate of 1.0 ACH, a recommended ventilation flow rate of Korea school standard for acceptable indoor air quality in the case of one person, CO_{2}$ gas concentration decreases up to $55{\%}$ within 50 minutes without occupancy and increases up to $75{\%}$ in the case of one occupant. Also indoor air quality at the school classroom is investigated experimentally.

조임쇠 경사길이에 따른 체결식 커플러의 이음성능 평가 (Splice Performance Evaluation of Fastening Coupler According to the Slope Length of Internal Fasteners)

  • 정현석;최창식
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제26권4호
    • /
    • pp.11-19
    • /
    • 2022
  • 본 연구에서는 기계식 커플러의 이음성능을 향상시키기 위해 다른 접합방식을 가진 두 가지의 새로운 커플러를 개발하였다. 두 가지 방식의 기계식 이음장치에 대하여 응력 해석을 수행하였다. 커플러의 재료특성, 접합방식, 내부 조임쇠의 경사길이를 변수로 최대 인장강도의 영향성을 분석하기 위해 일축인장시험을 수행하였다. 일축인장시험결과를 만족하는 시험체를 대상으로 KS D 0249에 의거하여 정적내력시험 및 반복하중 시험을 수행하였다. 이에 대한 연구결과는 다음과 같다. (1) 커플러의 인장강도와 내부 조임쇠의 경사길이는 최대 인장강도에 영향을 끼친다. (2) 연결 방식에 따라 접합된 철근의 강성, 슬립량, 강성감소율에 영향이 있다. 연구결과는 새롭게 제안된 향상된 기계식 이음장치의 현장 적용에 대한 가능성을 검증하였다.

HFO-1234yf를 적용한 가정용 냉동/냉장고의 성능평가 (Performance Evaluation of HFO-1234yf as a substitute for R-134a in a Household Freezer/Refrigerator)

  • 이장석;한준수;이명렬;전시문
    • 대한기계학회논문집B
    • /
    • 제35권7호
    • /
    • pp.743-748
    • /
    • 2011
  • R-134a 대체 냉매인 HFO-1234yf의 성능을 가정용 냉동/냉장고에서 평가하였다. AHAM(Associ- ation of Home Appliance Manufacturers) 규격에 의거하여 HFO-1234yf를 Drop-in하여 냉매 봉입량 시험, Pulldown 시험, 냉각속도 시험 그리고 소비전력 시험을 수행하였으며, R-134a 실험 결과와 비교하였다. $43^{\circ}C$ 고온 가혹 조건에 서도 시험을 수행하였다. 결과적으로 HFO-1234yf 냉매는 Cycle 성능면에서는 R-134a와 유사하나, 냉각속도는 모세관경을 더 크게 변경시켜야 한다.

EGR 밸브 평가 장치 개발을 위한 EGR 장착 엔진 성능 및 배출 가스 특성 연구 (A Study on Exhaust Gas Characteristics and Engine Performance of EGR Valve Installed Engine for Development of EGR Valve Test System)

  • 나동하;고춘식;서형준;이창언
    • 드라이브 ㆍ 컨트롤
    • /
    • 제9권4호
    • /
    • pp.52-57
    • /
    • 2012
  • In this study, in order to understand contents and ranges of design for the EGR Valve test system for improving quality and performance of EGR Valve, engine performance and exhaust gas characteristic of 3L-class diesel engine was analyzed. Experimental operation of engine performance test was performed with 50% engine load and 20% and 100% opening ratio of EGR Valve. From test of performance and exhaust gas characteristic of engine, torque output of engine and temperature and pressure of inlet and outlet of EGR Valve were measured. As a result, for design of EGR Valve test system, input fluid flow of EGR Valve must be set the same amount with exhaust gas flow that was below of engine speed of 2,500 rpm, and temperature of inlet of EGR Valve must be set under about $510^{\circ}C$. And the difference of temperature between inlet and outlet of EGR Valve must be over than about $200^{\circ}C$. Exhaust gas of inlet and outlet of EGR Valve were under 1 bar that was not considerable, and the difference of pressure between inlet and outlet of EGR Valve were under 1 bar that could not effect on mechanical operation of EGR Valve.

장기 보관된 분리장치의 성능 및 노화에 관한 연구 (Study of Aging and Performance About Separation Devices Has Been Stored)

  • 김동성;진홍식
    • 한국항공우주학회지
    • /
    • 제49권7호
    • /
    • pp.565-572
    • /
    • 2021
  • 본 연구에서는 국방 분야에서 분리장치로 사용되고 있는 파이로 장치 중 장기간 보관된 폭발볼트의 성능 및 노화에 관한 연구를 수행하였다. 연구를 위해 약 10년간 무기체계에 탑재되어 있던 폭발볼트를 확보하였으며, AIAA Standard 및 MIL-STD를 기반으로 성능 및 수명 평가 절차를 수립하였다. 성능 평가를 위해 먼저 비기능 검사를 수행하여 외적인 변화나 고장이 발생하였는지 확인하였으며, 내부 회로 및 구조에 이상이 없는지 회로검사와 X-ray 검사를 수행하였다. 비기능 검사가 통과된 시료에 대해서 작동 확인을 위한 성능 시험을 실시하였다. 성능 시험을 통해 폭발볼트의 분리 여부 및 분리시간을 측정하였으며, 일부 시료의 경우 잔여 수명 및 연장 가능성을 확인하기 위해 고온저장시험 후 성능 시험을 실시하였다. 마지막으로 시험 결과와 아레니우스 모델을 바탕으로 잔여 수명 및 신뢰도를 예측하였으며, 수명에 따른 신뢰도를 확인하였다.