• 제목/요약/키워드: Mechanical performance test

검색결과 2,614건 처리시간 0.028초

Performance Analysis of a Mixed-Flow Pump for Waterjet Propulsion

  • Ahn Jong-Woo;Kim Ki-Sup;Park Young-Ha;Kim Kyung-Youl;Oh Hyoung-Woo
    • Journal of Ship and Ocean Technology
    • /
    • 제9권2호
    • /
    • pp.11-20
    • /
    • 2005
  • A mixed-flow pump is largely applied for waterjet propulsion in high-speed vessels because of excellent cavitation performance. For the present study, we analyze the performance of mixed-flow pump, which is composed of impeller and stator. The test device for a mixed-flow pump was installed in the test section in the KRISO cavitation tunnel. The performance tests of two mixed-flow pumps were carried out with the test device at various flow rates using various nozzles. The test results agree fairly well with the predicted results by commercial CFD code. The test device is available for verification of impeller performance together with CFD analysis

Design of a CubeSat test platform for the verification of small electric propulsion systems

  • Corpino, Sabrina;Stesina, Fabrizio;Saccoccia, Giorgio;Calvi, Daniele
    • Advances in aircraft and spacecraft science
    • /
    • 제6권5호
    • /
    • pp.427-442
    • /
    • 2019
  • Small satellites represent an emerging opportunity to realize a wide range of space missions at lower cost and faster delivery, compared to traditional spacecraft. However, small platforms, such as CubeSats, shall increase their actual capabilities. Miniaturized electric propulsion systems can provide the satellite with the key capability of moving in space. The level of readiness of miniaturized electric propulsion systems is low although many concepts have been developed. The present research intends to build a flexible test platform for the assessment of selected small propulsion systems in relevant environment at laboratory level. Main goal of the research is to analyze the mechanical, electrical, magnetic, and chemical interactions of propulsion systems with the modern CubeSat-technology and to assess the performance of the integrated platform. The test platform is a 6U CubeSat hosting electric propulsion systems, providing mechanical, electrical and data interfaces, able to handle a variety of electric propulsion systems, thanks to the ability to regulate and distribute electric power, to exchange data according to several protocols, and to provide different mechanical layouts. The test platform is ready to start the first verification campaign. The paper describes the detailed design of the platform and the main results of the AIV activities.

70 N급 하이드라진 추력기의 추력실 최적설계와 시험평가 (Part II: 추력실 길이변화에 따른 펄스모드 성능특성) (Test & Evaluation for the Configuration Optimization of Thrust Chamber in 70 N-class N2H4 Thruster (Part II: Pulse-mode Performance According to the Chamber Length Variation))

  • 정훈;김종현;김정수
    • 한국추진공학회지
    • /
    • 제18권1호
    • /
    • pp.50-57
    • /
    • 2014
  • 70 N급 액체로켓엔진 개발모델의 추력실 최적설계형상 도출을 위한 지상연소시험을 수행하였다. 단일추진제급(순도: ${\geq}98.5%$) 하이드라진이 연소시험용 추진제로 선정되었고, 특성길이($L^*$) 2.79, 2.95, 그리고 3.13 m를 갖는 추력실에 대한 성능평가가 수행되었다. 시험조건 내에서의 촉매대 $L^*$ 증가는 추력기의 성능저하를 야기하는 것이 관찰되었으며, 개발모델의 펄스응답 성능이 현재 상용화되어 있는 하이드라진 추력기와 비교하여 우수한 것이 확인되었다.

콘크리트의 휨성능 증진 및 균열제어에 대한 특수 가공된 셀룰로오스섬유의 효과 (Effects of Specialty Cellulose Fibers on Improvement of Flexural Performance and Control of Cracking of Concrete)

  • 원종필;박찬기
    • 콘크리트학회논문집
    • /
    • 제12권2호
    • /
    • pp.89-98
    • /
    • 2000
  • The mechanical properties of specialty cellulose fiber reinforced concrete and the contribution of specialty cellulose fiber to drying shrinkage crack reduction potential of concrete and theirs evaluation are presented in this paper. The effects of differing fiber volume fraction(0.03%, 0.06%, 0.08%, 0.1%, 0.15%, 0.2%) were studied. The results of tests of the specialty cellulose fiber reinforced concrete were compared with plain and polypropylene fiber reinforced concrete. Flexural performance(flexural strength and flexural toughness) test results indicated that specialty cellulose fiber reinforcement showed an ability to increase the flexural performance of normal- and high- strength concrete(as compared to plain and polypropylene fiber reinforced concrete). Optimum specialty cellulose fiber reinforced concrete were obtianed using 0.08% fiber volume fraction. Drying shrinkage cracking test results confirmed specialty cellulose fibers are effective in reducing the drying shrinkage cracking of normal and high-strength concrete(as compared to popylene fiber reinforced concrete).

Linear모터의 위치 제어 성능 시험을 위한 Dynamometer 개발 (Development of a Linear Motor Dynamometer for Positioning Control Performance Test)

  • 노창렬;노명환;김주경;박종진;이응석
    • 대한기계학회논문집A
    • /
    • 제30권5호
    • /
    • pp.609-614
    • /
    • 2006
  • Recently linear motor has been used mainly for high speed feeding performance of machine tools. The advantages of linear motor are not only high speed but high accuracy, because it is not required the coupling and ballscrew for converting rotary to liner motion. Before applying in different moving system, the dynamometer is necessary to test the performance. In Korea, the linear motor is producing in a couple of company However, the liner motor dynamometer is not commercialized yet, like as rotary motor dynamometer. In this paper, a linear motor dynamometer is designed and manufactured using a MR damper. The dynamometer system developed in this study could be used for testing the positioning accuracy fur different loading conditions, traction forces, dynamic performance and so on.

공랭식 3단 왕복동 공기압축기의 시스템 설계 및 성능시험 (System design of an air-cooled 3-stage reciprocating air compressor and performance testing)

  • 이안성;김영철;정영식
    • 대한기계학회논문집B
    • /
    • 제21권10호
    • /
    • pp.1380-1391
    • /
    • 1997
  • A 150 m$^{3}$/hr, 30 kg/cm$^{2}$, air-cooled 3-stage reciprocating air compressor is designed to be used in starting large diesel engines. A basic design procedure is presented to meet the targeted pressure and flow rate, and especially the volumetric efficiency. Temperature and stress analyses of the cylinder are performed using FEM modelings. The dynamics of valve system is analyzed and stress at the valve seat due to valve impact is evaluated. To reduce friction loss and wear at the compressor engine system, tribological design practices are suggested. Fin-type coolers are designed to dissipate generated compression heat at each stage. Finally, a prototype is manufactured and performance test is carried out utilizing an air tank. Performance results are compared to the design targets, other foreign specifications, and some quality standards.

A Numerical Investigation of Flow and Performance Characteristics of a Small Propeller Fan Using Viscous Flow Calculations

  • Oh, Keon-Je;Kang, Shin-Hyoung
    • Journal of Mechanical Science and Technology
    • /
    • 제16권3호
    • /
    • pp.386-394
    • /
    • 2002
  • The present work is aimed at investigating an unusual variation in flow and performance characteristics of a small propeller fan at low flow rates. A performance test of the fan showed dual performance characteristics, i.e., radial type characteristics at low flow rates and axial type at high flow rates. Dual performance characteristics of the fan are numerically investigated using viscous flow calculations. The Finite Volume Method is used to solve the continuity and Navier-Stokes equations in the flow domain around a fan. The performance parameters and the circumferentially averaged velocity components obtained from the calculations are compared with the experimental results. Numerical values of the performance parameters show good agreement with the measured values. The calculation simulates the steep variations of performance parameters at low flow rates and shows the difference in the flow structure between high and low flow rates. At a low flow coefficient of $\Phi$=0.2, the flow enters the fan in an axial direction and is discharged radially outward at its tip, which is much like the flow characteristics of a centrifugal fan. The centrifugal effect at low flow rates makes a significant difference in performance characteristics of the fan. As the inlet flow rate increases, flow around the fan changes into the mixed type at $\Phi$=0.24 and the axial discharge at $\Phi$=0.4.

DEVELOPMENT OF DCT VEHICLE PERFORMANCE SIMULATOR TO EVALUATE SHIFT FORCE AND TORQUE INTERRUPTION

  • Park, S.J.;Ryu, W.S.;Song, J.G.;Kim, H.S.;Hwang, S.H.
    • International Journal of Automotive Technology
    • /
    • 제7권2호
    • /
    • pp.161-166
    • /
    • 2006
  • This paper presents shift characteristics of a dual clutch transmission(DCT). To obtain the shift force, dynamic models of the DCT are constructed by using MATLAB/Simulink and considering the rotational inertia of every component and the target pre-select time. Dynamic models of the shift and clutch actuators are derived based on the experimental results of the dynamic characteristics test. Based on the dynamic model of the DCT synchronizer, control actuator and vehicle model, a DCT vehicle performance simulator is developed. Using the simulator, the shift force and speed of the relevant shafts are obtained. In addition, the torque and acceleration of actuators are calculated during the shift process by considering the engaging and disengaging dynamics of the two clutches. It is observed from the performance simulator that uninterrupted torque can be transmitted by proper control of the two clutches.

소면적 PEM연료전지 성능개선 연구 (A Study on Performance Improvement in PEMFC)

  • 천광우;박창권;이호열;오병수
    • 한국수소및신에너지학회논문집
    • /
    • 제15권4호
    • /
    • pp.291-300
    • /
    • 2004
  • Performance of PEMFC is affected by many factors such as that of MEA, configuration of flow field, operating conditions, humidification, cooling and so on. In this study, in order to improve the performance of fuel cell, a small area fuel cell stack was made and its performance was tested under various operating conditions. Stack consists of 3 single PEM fuel cells. Channel is serpentine type and the active area of the electrode is $50cm^2$. The test results show that the peak power is 60W at $70^\circ{C}$ of stack temperature with humidification condition.

냉각 유량이 가스 포일 스러스트 베어링의 성능에 미치는 영향 (Effects of Cooling Flow Rate on Gas Foil Thrust Bearing Performance)

  • 황성호;김대연;김태호
    • Tribology and Lubricants
    • /
    • 제39권2호
    • /
    • pp.76-80
    • /
    • 2023
  • This paper describes an experimental investigation of the effect of cooling flow rate on gas foil thrust bearing (GFTB) performance. In a newly developed GFTB test rig, a non-contact type pneumatic cylinder provides static loads to the test GFTB and a high-speed motor rotates a thrust runner up to the maximum speed of 80 krpm. Force sensor, torque arm connected to another force sensor, and thermocouples measures the applied static load, drag torque, and bearing temperature, respectively, for cooling flow rates of 0, 25, and 50 LPM at static loads of 50, 100, and 150 N. The test GFTB with the outer radius of 31.5 mm has six top foils supported on bump foil structures. During the series of tests, the transient responses of the bearing drag torque and bearing temperature are recorded until the bearing temperature converges with time for each cooling flow rate and static load. The test data show that the converged temperature decreases with increasing cooling flow rate and increases with increasing static load. The drag torque and friction coefficient decrease with increasing cooling flow rate, which may be attributed to the decrease in viscosity and lubricant (air) temperature. These test results suggest that an increase in cooling flow rate improves GFTB performance.