• Title/Summary/Keyword: Mechanical parking equipment

Search Result 3, Processing Time 0.017 seconds

Risk Assessment of Mechanical Parking Facility during Construction based on AHP Analysis (AHP 분석을 이용한 기계식 주차설비 건설 중 위험성 평가방안 연구)

  • Lee, Jeong Han;Kim, Yong Gon;Lee, Jae Won;Kim, Jong Hoon
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.5
    • /
    • pp.33-41
    • /
    • 2022
  • As the number of automobile registrations increases yearly, parking spaces that are located in downtown areas are increasing, and mechanical parking facilities are also increasing. Therefore, there is a high risk of accidents when installing and repairing a mechanical parking facility. In the preceding six years (from 2012 to 2018), the statistics that pertain to accidental disasters indicated that a total of 137 disaster victims were generated by the construction sector, 33 accidents occurred, and 10 people died. However, only the safety management items pertaining to accidents that occur during maintenance work and the use of the installed mechanical parking facilities are being studied; furthermore, there is no ongoing research with respect to the risk management that is conducted at the construction site. In 2017, the Korea Occupational Safety and Health Agency (KOSHA) announced the "Guidelines for Safe Installation and Maintenance of Mechanical Parking Equipment"; however, it is a safety guideline that is limited to the installation of basic protective equipment and to facility installation. There is no model for mechanical parking facilities that is indicated in the "Risk Assessment Model by Construction Industry Type", which is issued by the Safety and Health Corporation and is widely utilized for risk assessment in the construction industry; moreover, elevator installation work CODE N0: 22 is the only major example of a disaster. In this study, "risk assessment through a focus group interview" was performed, and data was derived from the "risk assessment of Article 41 (2) of the Industrial Safety and Health Act", which reflects the characteristics of the construction industry based on AHP analysis. The results of this study can be utilized for the risk assessment that is conducted during the construction stage of mechanical parking facilities.

Improved transient performance of mechanical parking facilities through simultaneous PLC and inverter control (PLC와 인버터의 동시 제어를 통한 기계식 주차설비의 과도 상태 성능 향상)

  • Kim, Chang-Young;Lee, Kyo-Beum
    • Journal of IKEEE
    • /
    • v.25 no.1
    • /
    • pp.116-127
    • /
    • 2021
  • In this paper, we propose simultaneous control which improve in transient state performance of mechanical parking facilities through simultaneous control of PLC and inverter. In conventional mechanical parking facilities, it is controlled only by PLC, and it is more likely to generate over-currents in induction motors, and the ride comfort is reduced due to wear and damage caused by friction on the brake pads, and the life is shortened. To improve this problems the application of control techniques through simultaneous control of PLC and inverter prevents over-currents in induction motors, protects brake pads, improves ride comfort, increases control and ensures safety. We verify its validity by applying the proposed control method via simultaneous control of PLC and inverter to a mechanical parking facility.

A Study on the Environmental Planning Guidelines for Crime Safety at Elementary School settings (초등학교 교육환경의 범죄안전 환경계획방안에 관한 연구)

  • Byun, Gi-Dong;Ha, Mi-Kyoung
    • Korean Institute of Interior Design Journal
    • /
    • v.22 no.2
    • /
    • pp.211-219
    • /
    • 2013
  • The purpose of this study is to propose the environmental planning guidelines of elementary school settings for a crime safety. The research methodologies To achieve the goal, the literature review analysis and the survey were used as main research methodologies. The survey is organized as follows. First, elementary education facilities were divided into 20 spaces based on the major space. Second, after analyzing the domestic and foreign CPTED Guidelines, elements of environmental planning were classified to fit in the space. Based on this, the expert survey was conducted. The results of this study are as follows; First, it is necessary to consider specific places such as 'toilets', 'parking lot', 'in-between space', 'main access road', 'sub-access road' and 'harmful facilities around school' for safer school environment. Second, it is significant to plan 'equipment facilities' and 'outdoor space in the school setting' with priority for elementary education environment. Third, environmental planning elements for safer elementary schools can be classified into 9 factors(types) including 'natural surveillance planning', 'territoriality reinforcement planning', 'mechanical surveillance planning', 'access control planning' and 'neighborhood reinforcement planning'. Forth, regarding 'indoor space', crime-free elementary school environment can be build through 'natural surveillance planning' and 'territoriality reinforcement planning'. Finally, regarding 'outdoor space', the crime can be prevented through 'natural surveillance planning' and 'access control planning'.