• 제목/요약/키워드: Mechanical operation

검색결과 3,412건 처리시간 0.028초

아크유도형 DC 차단기의 동작 특성 (Operating Characteristics of Arc-induction Type DC Circuit Breaker)

  • 박상용;최효상
    • 전기학회논문지
    • /
    • 제67권7호
    • /
    • pp.981-986
    • /
    • 2018
  • AC(alternating current) CB(circuit breaker) at the fault occurred in the existing AC distribution system is limiting the fault current through zero cross-point. However, DC(direct current) CB does not have zero cross-point. Therefore, arc occurred by on-off operation of DC CB is very huge. Nowadays, many research team are studying the way to decrease breaking time, which is one of the essential conditions in DC CB. We suggested novel arc-induction type DC CB in this paper. The proposed arc-induction type DC CB is composed of the mechanical Arc ring and DC CB. We confirmed the operation of arc-induction type DC CB through the HFSS(High Frequency Structure Simulator) 3D simulation program and performed the experiment for operation characteristics. Results showed that arcing time of the arc-induction type DC CB by using induction ring was faster than existing mechanical DC CB. On the transient system, we confirmed stable operation characteristics of the arc-induction type DC CB through the simulation and experimental results. We expect that the proposed arc-induction type DC CB technology is will go to stay ahead of the existing DC CB technology.

열펌프 시스템의 난방 운전 시 최적 성능 제어에 관한 연구 (A Study on the Optimal Performance Control of Heat Pump System for Heating Mode Operation)

  • 유근중;이일환;이길봉;김민수
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.669-674
    • /
    • 2006
  • The optimal control of heat pump performance for heating mode operation was investigated. Fuzzy logic was applied to control the heating performance of heat pump system and superheat at compressor discharge was taken as a control variable. Regression model was adapted to determine the optimal points where COP is maximized. Optimization of fuzzy rule table was investigated to improve operation performance of heat pump system. Experiments were carried out using original fuzzy table and the modified fuzzy rule table for heating mode operation of heat pump system. The results show that control performance of heat pump system with the modified fuzzy rule table was better than that with the original rule table.

  • PDF

PEMFC의 열관리가 시스템의 성능에 미치는 영향 (The Effect of Thermal Management on the Performance of a Polymer Electrolyte Membrane Fuel Cell System)

  • 이정호;명노성;김동섭
    • 대한기계학회논문집B
    • /
    • 제35권6호
    • /
    • pp.593-601
    • /
    • 2011
  • 다양한 작동 조건에서 고분자 전해질형 연료전지의 성능 변화를 예측하기 위한 해석 프로그램을 구성하여 열관리가 시스템의 성능에 미치는 영향을 해석하였다. 전체 시스템은 연료전지 스택, 공기공급계, 연료공급계, 열 관리계로 구성 되었으며 각 구성부의 설계점을 고려하여 열역학적 모델링을 적용 하였다. 외기온 변화와 냉각 시스템의 성능 변화에 따라 연료전지 스택의 온도 및 출력 변화가 예상되므로 탈설계 해석을 하여 전체 시스템의 성능 변화를 예측하였다.

다구찌 방법을 이용한 Inconel 718 소재의 선삭가공에서 표면거칠기 최적화 (Searching Optimal Cutting Condition for Surface Roughness In Turning Operation on Inconel 718 using Taguchi Method)

  • 차진훈;한상보
    • 한국생산제조학회지
    • /
    • 제19권2호
    • /
    • pp.295-300
    • /
    • 2010
  • Inconel 718 alloy, widely used as material of aircraft engine, has a good mechanical property in high temperature, strong anti-oxidation characteristics in oxidated current over $900^{\circ}C$, and also is not easily digested in the air containing sulfur, therefore, its usage as mechanical component is expanding rapidly. Even though Inconel alloy 718 is difficult to machine, it requires highly precise processing/machining to sustain its component quality of high accuracy. In this paper, general turning operation conditions arc tested to select the best cutting process condition by measuring surface roughness through implementing experiments with orthogonal array of cutting speed, feeding speed and cutting depth as processing parameters based on the Taguchi method. Optimal turning operation conditions are extracted from the proposed experimental models.

선삭가공시의 인코넬 718합금의 표면거칠기 최적 절삭조건 (Optimal Cutting Conditions of Surface Roughness for Inconel 718 Alloy in Turning Operation)

  • 박종민;최원식;권순홍;차진훈
    • 한국기계가공학회지
    • /
    • 제8권4호
    • /
    • pp.48-53
    • /
    • 2009
  • Inconel 718 alloy, widely used as material of aircraft engine, has a good mechanical property in high temperature, strong anti-oxidation characteristics in oxidated current over $900^{\circ}C$, and also is not easily digested in the air containing sulfur, therefore, its usage as mechanical component is expanding rapidly. Even though Inconel alloy 718 is difficult to machine, it requires highly precise processing/machining to sustain its component quality of high accuracy. In this paper, general turning operation conditions are tested to select the best cutting process condition by measuring surface roughness through implementing experiments with orthogonal array of cutting speed, feeding speed and cutting depth as processing parameters based on the Taguchi method. Optimal turning operation conditions are extracted from the proposed experimental models.

  • PDF

선삭가공에서 절삭력을 일정하게 유지하기 위한 적응제어 (Adaptive Control for Cutting Force Regulating in Turning Operation)

  • 노상현;김진락;김교형
    • 대한기계학회논문집
    • /
    • 제17권1호
    • /
    • pp.69-77
    • /
    • 1993
  • 본 연구에서는 Koren과 Masory가 개발하여 적분제어기에 적용한 제어알고리즘 을, 제어기 반응속도를 향상시키기 위하여 비례적분제어기에 적용하는 방법을 제시하 고자 한다. 실험을 통하여 제어시스템을 모델링하고, 근궤적법을 이용하여 시스템을 안정하게 유지하기 위한 개회로 이득을 선정하며, 기존의 보통선반을 적응제어시스템 으로 개발하여 고정이득 비례적분제어기와 가변이득 비례적분제어기의 성능을 실험을 통하여 비교하고자 한다.

고온가스 및 액체 바이패스 적용 용량가변 히트펌프의 성능특성에 관한 실험적 연구 (An Experimental Study on the Performance Characteristics of Hot-gas and Liquid Bypass Heat Pump Systems for Capacity Modulation)

  • 안재환;주영주;윤원재;강훈;김용찬
    • 설비공학논문집
    • /
    • 제25권3호
    • /
    • pp.137-142
    • /
    • 2013
  • A small air-conditioner or chiller for a constant temperature bath normally uses a constant speed compressor. The constant speed compressor is relatively inexpensive, but it uses on/off control for capacity modulation. The on/off control has several disadvantages, specifically energy loss and large temperature fluctuation. Continuous operation with a bypass system can be an alternative to on/off control, for capacity modulation. In this study, a heat pump system having a hot-gas bypass and a liquid bypass was adopted. The performance of the bypass-type heat pump was measured, by varying the bypass valve opening. The differences of the COP between the hot-gas bypass and the liquid bypass, in the cooling and heating operations, were within 2% and 1%, respectively. The liquid bypass showed a wider range of capacity control in the cooling operation but the hot-gas bypass showed a wider range of capacity control in the heating operation.

Power Cable Ampacity and Influential Factors Analysis under Operation

  • Tong, Qiang;Qi, Jianping;Wang, Yanling;Liang, Likai;Meng, Xiangxing;Zhang, Qiang
    • Journal of Information Processing Systems
    • /
    • 제14권5호
    • /
    • pp.1136-1149
    • /
    • 2018
  • With the increasing of urban electricity demand, making the most use of the power cable carrying capacity has become an important task in power grid system. Contrary to the rated ampacity obtained under extremely conservative conditions, this paper presents the various steady value of cable ampacity by using the changing surrounding parameters under operation, which is based on cable ampacity calculation equation under the IEC-60287 standard. To some degree, the cable ampacity analysis of actual surroundings improves the transmission capacity of cables. This paper reveals the factors that influence cable ampacity such as insulating layer thickness, allowable long-term conductor temperature, the ambient temperature, soil thermal resistance coefficient, and so on, then gives the class of the influence of these parameters on the ampacity, which plays a great role in accurately calculating the real-time ampacity and improving the utilization rate of cable in the complex external environment condition. Furthermore, the transient thermal rating of the cable is analyzed in this paper, and temperature variation of the conductor under different overload conditions is discussed, which provides effective information for the operation and control of the system.

FATIGUE LIFE ASSESSMENT OF REACTOR COOLANT SYSTEM COMPONENTS BY USING TRANSFER FUNCTIONS OF INTEGRATED FE MODEL

  • Choi, Shin-Beom;Chang, Yoon-Suk;Choi, Jae-Boong;Kim, Young-Jin;Jhung, Myung-Jo;Choi, Young-Hwan
    • Nuclear Engineering and Technology
    • /
    • 제42권5호
    • /
    • pp.590-599
    • /
    • 2010
  • Recently, efficient operation and practical management of power plants have become important issues in the nuclear industry. In particular, typical aging parameters such as stress and cumulative usage factor should be determined accurately for continued operation of a nuclear power plant beyond design life. However, most of the major components have been designed via conservative codes based on a 2-D concept, which do not take into account exact boundary conditions and asymmetric geometries. The present paper aims to suggest an effective fatigue evaluation methodology that uses a prototype of the integrated model and its transfer functions. The validity of the integrated 3-D Finite Element (FE) model was proven by comparing the analysis results of individual FE models. Also, mechanical and thermal transfer functions, known as Green's functions, were developed for the integrated model with the standard step input. Finally, the stresses estimated from the transfer functions were compared with those obtained from detailed 3-D FE analyses results at critical locations of the major components. The usefulness of the proposed fatigue evaluation methodology can be maximized by combining it with an on-line monitoring system, and this combination, will enhance the continued operations of old nuclear power plants.

승용차의 부분부하제어를 위한 스크류형 과급기 개발 (Development of a Screw Type Super-Charger for Part Load Control of Passenger Car)

  • 배재일;배신철
    • 대한기계학회논문집B
    • /
    • 제27권10호
    • /
    • pp.1427-1434
    • /
    • 2003
  • Turbo- or Super-charging has been used to boost engine power for Gasoline- and Diesel Engine since beginning of 20th century. So far turbo-charger has enjoyed a high reputation in the charging field for its technical advantages such as no demand of operation power from engine and an excellent charging effect in a static operation at mid- and high engine speed. A mechanically driven super-charger, however, is now popular due to the high engine power at quick change of the driving mode - high engine torque even at low engine speed. Since super-charger needs operation power from engine, it is difficult to improve its relatively higher fuel consumption than that of turbo-charger. This negative point is still an obstacle to the wide use of supercharger. Super-charger using screw-type compressor will fulfill the purpose to reduce fuel consumption by minimizing operation power owing to no charge at idling or part load driving condition. This study aims to develop power control concept to achieve the minimization of operation power. A screw type super-charger was modified in design partially and installed with an internal bypass valve and a bypass tube to control charging pressure at part load. The various control concepts show a possibility to reduce operation power of super-charger.