• Title/Summary/Keyword: Mechanical glove

Search Result 13, Processing Time 0.033 seconds

Development of Exoskeleton-Type Data Glove for Position/Force Feedback (위치/힘 피드백이 가능한 외골격 구조의 데이터 글로브 개발)

  • Kim, Min-Jeong;Kim, Dae-Gyeong;Park, Han-Gil;Kim, Ui-Kyum;Choi, Byung-June;Choi, Hyouk-Ryeol
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.12
    • /
    • pp.1585-1591
    • /
    • 2011
  • In this paper, we present a new exoskeleton-type data glove that can sense the movement of the human finger and reflect the force to the finger. The data glove is designed on the basis of the skeletal structure of the human hand, and the finger module has 1 degree-of-freedom because it includes three four-bar mechanism joints in series and a wire-coupling mechanism. In addition, the transmission ratio of the finger module is maintained at 1:1.4:1 over the entire movement range, and hence, the module can perform both extension and flexion. In addition, to enable adduction/abduction motion of the human hand, a unique MCP joint is designed by using two universal joints. To validate the feasibility of the data glove, master-slave control experiments based on force-position control between the data glove and the robot hand are conducted.

A Study on the Improvement of Flow Characteristics of the Glove Valve for Compressible Fluid (압축성 유체용 글로브 밸브의 유량특성 향상에 관한 연구)

  • Bae, Ji Won;Chung, Woo Young;Jang, Ji Seong
    • Journal of Drive and Control
    • /
    • v.16 no.4
    • /
    • pp.32-37
    • /
    • 2019
  • Glove valves are used for various purposes in the process control field because such valves enable easy control of temperature and pressure. However, such valves are associated with significant loss of pressure and also have the disadvantage of complicating the shape of the cage or plug to facilitate linear flow rate change. In this paper, the shape of the plug, one of the valve flow control elements, was designed to improve the flow characteristics of the glove valve, and then CFD analysis was performed using compressible fluid. The numerical analysis results of the glove valve were analyzed according to the opening ratio and the pressure ratio of the valve. From these results, it was found that the proper notch on the side of the plug contributed to reducing the energy loss of the fluid through the valve and improving the linearity of the valve.

Valve Seat Design for Full Contact Effect Using Grey Relational Analysis (회색 관계 분석법을 이용한 누수 방지용 밸브 시트 설계)

  • Lee, Jung-Hee;Kang, Gyeong-Ah;Kwak, Jae-Seob
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.4
    • /
    • pp.17-22
    • /
    • 2018
  • A glove valve regulates the flow in a pipeline as a kind of control valve. However, when the disc and seat contact, the valve structure can be distorted and flow can leak due to the elongation of the valve material under high pressure. The surface texture is not good enough to seal the contact surface (in practice) because the lapping process is usually done manually. Furthermore, assembly performance is analyzed by structural analysis. Compared with a standard seat, the newly designed seat had a smaller radial deformation and a larger longitudinal deformation. Therefore, the newly designed seat can maintain a tight and uniform contact with the disc with a reduced radial deformation and an expanded available seal area with an increased longitudinal deformation. The seal performance of the glove valve has been improved in a cost-effective manner.

Device for Assisting Grasping Function

  • Jeong, Gu-Young;Yu, Kee-Ho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.77.5-77
    • /
    • 2002
  • A mechanical device was developed for assisting the grasping function of a person whose fingers suffered cervical injury and thus are unable to grasp. This device is composed of a mechanical glove put on the user's hand and a muscle sensor to measure the activity of his or her muscle. The mechanical glove consists of a finger frame, a base and an air cylinder mounted on the base. With the kinematics carefully designed, the finger frame can achieve the grasping motion under the actuation of the air cylinder. For controlling this motion, an innovative sensor was developed to detect the user's motion intention. The sensor measures the change of the muscle stiffness...

  • PDF

Manufacturing Micrometer Scale Structures by an Optical Tweezers System Controlled by CyberGlove (가상장갑으로 제어되는 광핀셋 시스템을 이용한 마이크로 구조물의 제작)

  • Park, I.Y.;Lee, J.H.;Lee, Y.G.
    • Korean Journal of Computational Design and Engineering
    • /
    • v.12 no.4
    • /
    • pp.298-307
    • /
    • 2007
  • In recent years, researchers are actively investigating new methods that are applicable for manufacturing micrometer to nanometer scale structures. Among them, optical tweezers that can manipulate microscopic objects using a laser is receiving one of the key attentions. Optical tweezers have been used actively in the field of science. For example, for measuring mechanical characteristics in the scale of piconewtons or for manipulating and sorting large numbers of particles, bacteria, cells. etc. However, little works have been reported for "manufacturing" objects. In this paper, we present a new method for manufacturing micrometer scale structures using micrometer scale biotin coated polystyrene particles. Particles will be controlled with a user interface that utilizes a CyberGlove and glued together by the bonding force between biotin and streptavidin.

A Wireless Glove-Based Input Device for Wearable Computers

  • An, Sang-Sup;Park, Kwang-Hyun;Kim, Tae-Hee;Jeon, Jae-Wook;Lee, Sung-Il;Choi, Hyuck-Yeol;Choi, Hoo-Gon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1633-1637
    • /
    • 2003
  • Existing input devices for desktop computers are not suitable for wearable computers because they are neither easy to carry nor convenient to use in a mobile working environment. Different input devices for wearable computers must be developed. In this paper, a wireless glove-based input device for wearable computers is proposed. The proposed input device consists of a pair of chording gloves. Its keys are mounted on the fingers and their chording methods are similar to those of a Braille keyboard. RF (Radio Frequency) and IrDA (Infrared Data Association) modules are used to make the proposed input device wireless. Since the Braille representation for numbers and characters is efficient and has been well established for many languages in the world, the proposed input device may be one of good input devices to computers. Furthermore, since the Braille has been used for visually impaired people, the proposed one can be easily used as an input device to computers for them.

  • PDF

Dynamic Property Identification of Structural Systems with Hinge Joint Using Equivalent Stiffness (등가강성모델을 활용한 힌지체결부 동특성 동정)

  • Won, Junho;Lim, Che Kyu;Lee, Doo-Ho;Choi, Joo-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.12
    • /
    • pp.1635-1642
    • /
    • 2012
  • The identification of the dynamic properties of structural joints is important for predicting the dynamic behavior of assembled systems. However, the identification of the properties using analytical or experimental approaches is extremely difficult or even impossible. Several studies have proposed hybrid or synthesis methods that simultaneously used analytical and experimental approaches to identify the dynamic properties of a joint. However, among the many types of joints, only the bolt joint was treated as a practical example in these studies. In this study, for a simple assembly system comprising two plates and one hinge joint, a simple methodology involving the use of the static-based subpart analysis method to identify the dynamic properties is proposed. Finally, the proposed method is applied to a glove box in a passenger vehicle that includes hinge joints.

Reliability Analysis of Finger Joint Range of Motion Measurements in Wearable Soft Sensor Gloves (웨어러블 소프트 센서 장갑의 손가락 관절 관절가동범위 측정에 대한 신뢰도 분석)

  • Eun-Kyung Kim;Jin-Hong Kim;Yu-Ri Kim;Ye-Ji Hong;Gang-Pyo Lee;Eun-Hye Jeon;Joon-bum Bae;Su-in Kim;Sang-Yi Lee
    • PNF and Movement
    • /
    • v.21 no.2
    • /
    • pp.171-183
    • /
    • 2023
  • Purpose: The purpose of this study was to compare universal goniometry (UG), which is commonly used in clinical practice to measure the range of motion (ROM) of finger joints with a wearable soft sensor glove, and to analyze the reliability to determine its usefulness. Methods: Ten healthy adults (6 males, 4 females) participated in this study. The metacarpophalangeal joint (MCP), interphalangeal joint (IP), and proximal interphalangeal joint (PIP) of both hands were measured using UG and Mollisen HAND soft sensor gloves during active flexion, according to the American Society for Hand Therapists' measurement criteria. Measurements were taken in triplicate and averaged. The mean and standard deviation of the two methods were calculated, and the 95% limits of agreement (LOA) of the measurements were calculated using the intraclass correlation coefficient (ICC) and Bland-Altman plot to examine the reliability and discrepancies between the measurements. Results: The results of the mean values of the flexion angles for the active range of motion (AROM) of the finger joints showed large angular differences in the finger joints, except for the MCP of the thumb. In the inter-rater reliability analysis according to the measurement method, the ICC (2, 1) value showed a low level close to 0, and the mean difference by the Bland-Altman plot showed a value greater than 0, showing a pattern of discrepancy. The 95% LOA had a wide range of differences. Conclusion: This study is a preliminary study investigating the usefulness of the soft sensor glove, and the reliability analysis showed a low level of reliability and inconsistency. However, if future studies can overcome the limitations of this study and the technical problems of the soft sensor glove in the development stage, it is suggested that the measurement instrument can show more accurate measurement and higher reliability when measuring ROM with UG.

Inexpensive Visual Motion Data Glove for Human-Computer Interface Via Hand Gesture Recognition (손 동작 인식을 통한 인간 - 컴퓨터 인터페이스용 저가형 비주얼 모션 데이터 글러브)

  • Han, Young-Mo
    • The KIPS Transactions:PartB
    • /
    • v.16B no.5
    • /
    • pp.341-346
    • /
    • 2009
  • The motion data glove is a representative human-computer interaction tool that inputs human hand gestures to computers by measuring their motions. The motion data glove is essential equipment used for new computer technologiesincluding home automation, virtual reality, biometrics, motion capture. For its popular usage, this paper attempts to develop an inexpensive visual.type motion data glove that can be used without any special equipment. The proposed approach has the special feature; it can be developed as a low-cost one becauseof not using high-cost motion-sensing fibers that were used in the conventional approaches. That makes its easy production and popular use possible. This approach adopts a visual method that is obtained by improving conventional optic motion capture technology, instead of mechanical method using motion-sensing fibers. Compared to conventional visual methods, the proposed method has the following advantages and originalities Firstly, conventional visual methods use many cameras and equipments to reconstruct 3D pose with eliminating occlusions But the proposed method adopts a mono vision approachthat makes simple and low cost equipments possible. Secondly, conventional mono vision methods have difficulty in reconstructing 3D pose of occluded parts in images because they have weak points about occlusions. But the proposed approach can reconstruct occluded parts in images by using originally designed thin-bar-shaped optic indicators. Thirdly, many cases of conventional methods use nonlinear numerical computation image analysis algorithm, so they have inconvenience about their initialization and computation times. But the proposed method improves these inconveniences by using a closed-form image analysis algorithm that is obtained from original formulation. Fourthly, many cases of conventional closed-form algorithms use approximations in their formulations processes, so they have disadvantages of low accuracy and confined applications due to singularities. But the proposed method improves these disadvantages by original formulation techniques where a closed-form algorithm is derived by using exponential-form twist coordinates, instead of using approximations or local parameterizations such as Euler angels.

Device for Assisting Grasping Function (2nd Report : Maneuverability Evaluation)

  • Moromugi, S.;Okamoto, A.;Kim, S.H.;Tanaka, H.;Ishimatsu, T.;Koujina, Y.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2665-2669
    • /
    • 2003
  • A wearable device to assist fingering function for disabled is developed in this study. This is the second paper to report the progress in development of this assisting device. The device is developed for a patient who suffers from cervical spinal cord injury. In the first paper, it was reported that the patient could successfully pick up several types of objects with his paralyzed fingers by using this device. As a next step, the maneuverability of the device under grasping operation is discussed in this paper. Maneuverability of the system is experimentally evaluated. The dexterity in controlling finger force is compared between the cases that non-disabled examinees operate their finger with inherent abilities and that a disabled examinee operates his finger by using the assisting device.

  • PDF