• 제목/요약/키워드: Mechanical Ventilation System

검색결과 279건 처리시간 0.022초

도로터널에서 종류식 환기 시설의 운전 방안 (An Operation Methed for Longitudinal Flow Ventilation System in a Road Tunnel)

  • 김태형;황인주;홍대희;정종승;정종경
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집B
    • /
    • pp.87-92
    • /
    • 2001
  • In automobile highway tunnels, in order to maintain a suitable environment for drivers and traffic, visibility in the tunnel must be maintained, and the concentrations of poisonous substances including carbon monoxide must be kept at or below allowable levels. For this reason, in long tunnels and tunnels with heavy traffic, ventilation facilities are installed. When the ventilation facilities are run at full capacity, the environment in the tunnel is obviously adequately maintained, but this consumes a great deal of electric power. Consequently, a central problem in highway tunnel ventilation control systems is to keep the pollution concentration at or below the allowable level, and thus provide a safe environment for traffic, while consuming as little electricity as possible. This paper introduces an operation method of longitudinal flow ventilation systems with jet-fan, dust collector and vertical ducts.

  • PDF

환기방식별 실내 환기효율 분석에 관한 실험적 연구 (An Experimental Analysis of Ventilation Effectiveness using Tracer Gas)

  • 강태욱
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권2호
    • /
    • pp.260-266
    • /
    • 2006
  • A tracer gas technique based on ASTM Standard E741-83 was used to measure ventilation performances in a model chamber ($0.84m{\times}0.68m{\times}0.7m$) with an exhaust fan and a supply fan. Experiments were performed for the ventilation effectiveness on three types of mechanical ventilation systems. For all cases. higher ventilation effectiveness was found in the type to ventilation system due to shorter residual time of air compared to type 1 and type 3.

스페이서의 재질변화에 따른 전열교환기 성능변화에 관한 연구 (A Study on The Performance of a Heat Recovery Ventilator According to the Properties of Spacers)

  • 임태건;전병헌;김종원;정성학;이승갑;안영철
    • 설비공학논문집
    • /
    • 제24권3호
    • /
    • pp.224-229
    • /
    • 2012
  • The importance of ventilation system is being emphasized by interest of indoor air quality. Especially, heat recovery ventilation system has attracted attention as most effective ventilation plan. Because it can reduce hazardous construction materials, indoor air pollutions, and also can reduce air conditioning energy cost. In heat recovery ventilator, the element core is the most important part. The element core is composed of liner and spacer. And liner and spacer are stacked alternately. On the Liner, heat and humidity transfer are made between supply and exhaust air. And spacer plays a role as a tunnel of exhaust and supply. In this study, we investigated and analyzed the efficiency of a heat recovery ventilator, when the spacer's properties are changed. As a result, difference spacer's properties affect an efficiency of heat recovery ventilator.

지하철 역사의 실내공기질 개선을 위한 공조기 적용 공기청정장치 선정에 대한 기초연구 (Study of HVAC system with air cleaning system for indoor air quality of subway station)

  • 정의경;박재홍;이양화;윤기영;황정호
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.537-540
    • /
    • 2008
  • A numerical study has been carried out on the optimization of an air cleaning system which was installed in a heating, ventilation and air conditioning system (HVAC) system of subway station for particle removal. Required particle removal efficiencies of three different air cleaning systems were calculated from ventilation rate, and indoor/outdoor concentration of PM10. Mass balance equations of PM10 were used to solve the required particle removal efficiencies. Fibrous filter was considered as an air cleaning system. Calculations were carried out about two different places which were waiting area and platform of subway station, respectively. This study proposed optimized design and operation condition of each air cleaning system.

  • PDF

시멘트 포장공정에서 환기시스템에 따른 발생분진의 제어 (Control of Suspended Dust in Various Ventilation Systems of Cement Packaging Process)

  • 이승철;김수창;노광철;박명호
    • 한국산학기술학회논문지
    • /
    • 제10권3호
    • /
    • pp.463-469
    • /
    • 2009
  • 시멘트 포장공정에서 발생하는 비산분진을 효율적으로 제거하기 위해 3가지 환기방식(국소배기시스템, 정전식스크러버시스템, 국소급기시스템)을 도입하고 풍량을 변화시키며 총 9가지의 조건에서 실험을 수행하였다. 분진의 농도는 시멘트분진 입자분포 특성을 고려하여 PM2.5, PM10, TSP로 구분하여 측정하였다. 3가지 환기방식에 대한 집진효율을 분석한 결과, 기존의 국소배기시스템과 정전식스크러버시스템이 같이 사용되는 경우 가장 효율적인 것으로 나타났다. 또한 정정식스크러버시스템의 풍량 증가에 따른 입자의 질량농도감소율이 큰 차이가 없는 것을 확인할 수 있었고 이로부터 정정식스크러버시스템을 $2,700m^3/h$ 풍량으로 운전하는 것이 에너지절약 관점에서 효율적인 것이라고 판단되었다. 각 환기방식별 환기성능을 국소배기시스템의 풍량으로 환산한 결과, 대체시스템(정전식스크러버시스템, 국소급기시스템)분진제거성능이 우수한 젓으로 나타났고 정전식스크러버시스템이 국소급기시스템보다 상당히 효율적인 것으로 나타났다. 따라서 기존의 국소배기시스템파 정전식스크러버시스템을 동시에 가동한다면 국소배기시스템의 풍량만을 증가시키는 경우에 비해 반송동력을 줄일 수 있어 분진제거와 에너지절감측면에서 훨씬 효율적이라는 것을 알 수 있었다.

자연환기용 공장창호의 빗물유입 저감대책에 관한 실험적 연구 (Experimental study on reduction in rain water penetration through industrial windows used for natural ventilation)

  • 박승욱;김태형;하현철;허영빈
    • 한국산업보건학회지
    • /
    • 제20권3호
    • /
    • pp.175-183
    • /
    • 2010
  • Windows are widely used for natural ventilation of the various buildings. Especially high level windows as a part of industrial ventilation systems, play a crucial role in natural ventilation. Compared to mechanical ventilation system, natural ventilation has the advantage of lower installation and operating costs. In general, high level windows for industrial buildings have three types; louver type, 45$^{\circ}$ open type and 90$^{\circ}$ open type. Based on previous studies, it was found that the louver type and 45$^{\circ}$ open type are very effective in reducing rainwater penetration, but they did not have enough ventilation efficiencies. Preliminary tests were performed with the various types of windows. It was found that a 90$^{\circ}$ open double layer type window was the best among those which tested in our preliminary tests. Simulated rain was used to estimate the amount of rain penetrated through windows and to observe the paths of rain penetration. Various 90$^{\circ}$ open windows were tested to find the windows with minimum rain penetration and maximum ventilation efficiency.

침실 공기질 개선을 위한 강제 환기횟수에 관한 연구 (A study on Forced Ventilation Rate for Bedroom Indoor Air Quality Improvement)

  • 김동규;이성;김세환
    • KIEAE Journal
    • /
    • 제9권1호
    • /
    • pp.85-90
    • /
    • 2009
  • The indoor air quality is one of the most important issues of designing ventilation in high rise apartment buildings. This study suggested proper ventilation rate in the apartment bedroom where mechanical ventilation system has installed. Six university students(four male and two female) were participating in the experiment. Experiments were performed in environmental chamber. Experimental conditions were combinations from three ventilation rate 0, 0.4 and 0.7. Measurement items during 8 hours of experimental time were temperature, humidity, carbon dioxide concentrations and questionnaire surveyed aftrer sleeping. The concentration of Carbon Dioxide depending on ventilation rate in the chamber was analyzed for proper ventilation rate. The results of this paper can be summarized as follows. (1) When two persons experiment, 0.7 ventilation rate was in excess of 1000ppm. (2) When one person experiment, 0.7 and 0.4 ventilation rates were satisfied the criteria of IAQ. (3) It compared 0.4 with 0.7 in the ventilation rate, 0.4 ventilation rate could reduced about 80% of the power by fan similarity law.

공동주택의 환기설비설계기준제정에 관한 연구 (A Study on the Code of Designs for Residential Mechanical Ventilation System)

  • 홍진관;권용일
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.97-103
    • /
    • 2005
  • The purpose of this code is to relate the various controllable factors to the comfort and well-being of the people using the building, so that the requirements of the system design and installation of residential mechanical ventilation. The recommendations made in this code recognize the need to optimize the use of energy, reduce hazards and minimize effects detrimental to the environment. This code was prepared by a committee convened by SAREK. The code provides broad guidance only on certain topics. The titles of standard and code referred to in this code are listed on the reference.

  • PDF

수면시 바닥표면온도에 따른 적정 환기량에 관한 연구 (A Study on the Proper Quantity of Ventilation through Changing Floor Temperature in Sleeping)

  • 김동규;이성;김세환
    • KIEAE Journal
    • /
    • 제10권1호
    • /
    • pp.19-24
    • /
    • 2010
  • Modern people are spending most of time in interior area. Indoor air environmental problem is one of the most effective factors influenceable to human health. Furthermore, saving energy and making ventilation system for pleasant indoor environment are necessary when it is faced shortage of energy over the world. In our country's case, it is already imposed that required quantity of air ventilation in buildings is 0.7 times per hour on "The regulation on building engineering system". As on the rise of the interests about Indoor air environment, Heat and Carbon dioxide emissions from User's metabolism, activity, furniture, and construction materials etc. could be the causes of Indoor air pollution. If these materials stays in Indoor air for so long, it could directly influence the user's health condition with a disease. As of building's sterilization improved that raised more mechanical ventilation. It also leads much energy waste in a period of high price of fossil fuel. Therefore, the way that saves energy and effective control of indoor ventilation is urgently needed. So, this study places the purpose on validating volume of indoor ventilation and user's comfortable degree by comparison CO2 emission rate through changing floor temperature.

강제환기가 적용된 시험공간에서 냉난방부하의 시뮬레이션 및 실증실험 (Simulation and Verification Experiment of Cooling and Heating Load for a Test Space with Forced Ventilation)

  • 김동혁;홍희기;유호선;김욱중
    • 설비공학논문집
    • /
    • 제18권12호
    • /
    • pp.947-954
    • /
    • 2006
  • Building energy consumption according to the ventilation has been considered to be an important subject. The purpose of this study is to investigate the cooling and heating loads in a test space with a forced ventilating system. In the test space, on/off controlled air-conditioning and forced ventilating facility were operated between 8 : 30 to 21 : 00 during 4 days and some important data like temperatures and energy consumption were measured to obtain actual thermal loads. The simulation was carried out in a mode of temperature level control using a TRNSYS 15.3 with a precisely measured air change amount and performance data of air-conditioner. Heating load and cooling load including sensible and latent were compared between by experiment and by simulation. Both of thermal loads associated with ventilation show a close agreement within an engineering tolerance.