• 제목/요약/키워드: Mechanical Ventilation System

검색결과 277건 처리시간 0.027초

환기상태 분석에 따른 급 배기구 위치 평가 (Evaluation of the location of the Outlets according to the Analysis of Ventilation conditions)

  • 문용준;김혁순;곽명근;오명도
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1207-1212
    • /
    • 2008
  • The purpose of this study is to evaluate the location of the outlets in the mechanical ventilation system installed in apartment. We performed the numerical analysis to estimate the ventilation effectiveness and the indoor $CO_2$ concentration considering the occupants and the condition with inlet and outlet in each room. From the numerical results, modified location of the outlets is about 10% high than designed one with respect to the ventilation effectiveness when the occupants are not considered. But designed location of inlet and outlet in living room and kitchen is better than modified one with respect to the reduction of $CO_2$ concentration in the living room and kitchen with occupants. In case of our model, Air change per hour (0.7) is not enough to sustain the acceptable criteria of $CO_2$ concentration (1000ppm) in the room with the occupants

  • PDF

PCV(Positive Crankcase Ventilation) 밸브의 유동특성에 관한 수치해석 (Computational Analysis of Flow Characteristics of a PCV Valve)

  • 이종훈;최윤환;이연원
    • 한국자동차공학회논문집
    • /
    • 제13권4호
    • /
    • pp.66-73
    • /
    • 2005
  • A great deal of exhaust gas inside a combustion room goes out through exhaust pipe. But residual gas 'Blowby gas' enters the crankcase through a small gap between the piston and the cylinder wall. Here, if the blowby gas isn't vented, this causes many bad efffcts such as lubricant oil contamination, corrosion by that and crankcase explosion by rising pressure. So most automobiles are constituted with a PCV(Positive Crankcase Ventilation) system to prevent previous problems. PCV valve is the most important part in this ventilation system. When companies are manufacturing new cases, engineers are designing it depending on their experiments than theoretical knowledges. Much efforts and times are needed for new development. This study will show quantitative results to increase the possibilities for the optimal design.

장기간 인공환기가 필요한 유기인계 중독환자의 연관인자 분석 (Clinical Characteristics of Patients with Acute Organophosphate Poisoning Requiring Prolonged Mechanical Ventilation)

  • 신황진;이미진;박규남;박준석;박성수
    • 대한임상독성학회지
    • /
    • 제6권1호
    • /
    • pp.32-36
    • /
    • 2008
  • Purpose: The major complication of acute organophosphate (OP) poisoning is respiratory failure as a result of cholinergic toxicity. Many clinicians find it difficult to predict the optimal time to initiate mechanical ventilation (MV) weaning, and as a result have tended to provide a prolonged ventilator support period. The purpose of this study is to determine any clinical predictors based on patients characteristics and laboratory findings to assist in the optimal timing of mechanical ventilator weaning. Methods: We reviewed medical and intensive care records of 44 patients with acute OP poisoning who required mechanical ventilation admitted to medical intensive care unit between July 1998 and June 2007. Patient information regarding the poisoning, clinical data and demographic features, APACHE II score, laboratory data, and serial cholinesterase (chE) levels were collected. Base on the time period of MV, the patients were divided into two groups: early group (wean time < 7 days, n = 28) and delayed group (${\geq}$ 7 days, n = 16). Patients were assessed for any clinical characteristics and predictors associated with the MV weaning period. Results: During the study period, 44 patients were enrolled in this study. We obtained the sensitivity and specificity values of predictors in the late weaning group. APACHE II score and a reciprocal convert of hypoxic index but specificity (83.8%) is only APACHE II score. Also, the chE concentration (rho = -0.517, p = 0.026) and APACHE II score (rho = 0.827, p < 0.001) correlated with a longer mechanical ventilation duration. Conclusion: In patients with acute OP poisoning who required mechanical ventilation, the APACHE II scoring system on a point scale of less than 17 and decrements in cholinesterase levels on 1-3 days were good predictors of delayed MV weaning.

  • PDF

기도 이중 양압(BiPAP)을 이용한 비강 간헐 양압환기의 임상적 적용 (Clinical Application of Nasal Intermittent Positive Pressure Ventilation with Bi-level Positive Airway Pressure(BiPAP))

  • 조재연;이상엽;이상화;박상면;서정경;심재정;인광호;강경호;유세화
    • Tuberculosis and Respiratory Diseases
    • /
    • 제42권5호
    • /
    • pp.723-730
    • /
    • 1995
  • Background: Noninvasive ventilation has been used extensively for the treatment of patients with neuromuscular weakness or restrictive chest wall disorders complicated by hypoventilatory respiratory failure. Recently, noninvasive positive pressure ventilation has been used in patients with alveolar hypoventilation, chronic obstructive pulmonary disease(COPD), and adult respiratory distress syndrome. Sanders and Kern reported treatment of obstructive sleep apnea with a modification of the standard nasal CPAP device to deliver seperate inspiratory positive airway pressure(IPAP) and expiratory positive airway pressure(EPAP). Bi-level positive airway pressure(BiPAP) unlike nasal CPAP, the unit delivers a different pressure during inspiration from that during expiration. The device is similar to the positive pressure ventilator or pressure support ventilation. Method and purpose: Bi-level positive airway pressure(BiPAP) system(Respironics, USA) was applied to seven patients with acute respiratory failure and three patients on conventional mechanical ventilation. Results: 1) Two of three patients after extubation were successfully achieved weaning from conventional mechanical ventilation by the use of BiPAP ventilation with nasal mask. Five of seven patients with acute respiratory failure successfully recovered without use of conventional mechanical ventilation. 2) $PaO_2$ 1hour after BiPAP ventilation in acute respiratory failure patients significantly improved more than baseline values(p<0.01). $PaCO_2$ 1hour after BiPAP ventilation in acute respiratory failure patients did not change significantly more than baseline values. Conclusion: Nasal mask BiPAP ventilation can be one of the possible alternatives of conventional mechanical ventilation in acute respiratory failure and supportive method for weaning from mechanical ventilation.

  • PDF

도로 터널내의 공기유동 양상을 예측하기 위한 수치해석 (Numerical Analysis to Predict Air Flow Phenomena in a Road Tunnel)

  • 최인수;박병덕;윤일로
    • 한국산업융합학회 논문집
    • /
    • 제5권4호
    • /
    • pp.313-320
    • /
    • 2002
  • A 2-dimensional $k-{\varepsilon}$ numerical model was developed to explore the effects of vehicle movement, jet fan and wind speed for the ventilation of road tunnels. To consider the temperature distribution in the tunnel, the energy equation was solved with a source term of the energy exhausted from vehicles. Although the tunnel ventilation can be made by the piston effect of vehicle movement, an additional ventilation is necessary when a head wind is existing. Jet fans may assist the air flow in the tunnel. However, more efficient ventilation system should be necessary, because the exhaust gas from vehicles flow along the road surface and it cannot be diffused in the longitudinal tunnel.

  • PDF

코팅 룸 배기시스템 수치해석 및 성능개선에 대한 연구 (A Study on Numerical Analysis and Performance Improvement of Ventilation Systems in Coating Room)

  • 이기연;김국원
    • 한국산학기술학회논문지
    • /
    • 제14권5호
    • /
    • pp.2086-2091
    • /
    • 2013
  • 산업환기의 근본 목적은 유해물질로부터 작업자의 건강을 지키는 것으로, 제품생산과정에서 발생하는 유해물질 등을 빠른 시간에 외부로 배출하여 공기의 질을 높이고자 한다. 최근 산업환기에 대한 인식이 생산중심에서 인간중심으로 변하면서 이에 대한 중요성이 증가하고 있다. 본 연구에서는 아연말 코팅 룸에서 발생하는 악취제거를 목적으로 코팅 룸 내부의 공기유동에 대한 전산 시뮬레이션을 수행하였다. 3차원 CAD 프로그램인 SolidWorks를 이용하여 코팅 룸 전체와 배기시스템을 모델링하였으며 Flow Simulation 프로그램을 이용하여 오염물 발생 부위 중심으로 배기성능을 분석하였다. 또한 국소배기 장치를 이용하여 코팅 룸 내부 공기의 흐름 방향과 공기의 유속을 개선하였다.

돈사용 환기팬을 위한 돈사 내 온도 분포 특성 (Characteristics of Temperature Distribution of Pen for Exhaust Fan of Ventilation System)

  • 김현태;김웅
    • 한국축산시설환경학회지
    • /
    • 제20권4호
    • /
    • pp.155-160
    • /
    • 2014
  • This study was researched for use by data for the improvement of ventilation system of optimum environmental control systems. The ventilation system for windowless swine housing was installed negative pressure system that circular pipe duct for inlet was installed on the ceiling and axial flow fan for exhaust was installed on the sidewall. The temperatures in the pen was measured using infrared thermography camera and thermocouple with data-logger. The temperature measurement points was selected by infrared thermography camera is alley (G), inlet (A), front-upper (B), front-lower (C), rear-upper (D), rear-lower (E), forward fan (F). The temperature measured at those selected points for temperature distribution was $28^{\circ}C$ that was maintained setting temperature in suitably. The temperature deviations of F point and A~E points in windowless swine housing was less then average $0.5^{\circ}C$. The result of air velocity of measured points was suitable to the breeding of pigs.

실내 급.배기구 위치변화에 따른 실 공기유동에 관한 연구 (A Study on the Indoor Airflow Pattern by Changing the Location of Mechanical Terminal Unit)

  • 최정민;조성우
    • 설비공학논문집
    • /
    • 제21권3호
    • /
    • pp.193-200
    • /
    • 2009
  • The ventilation system of apartments can be divided by supply and exhaust fan, supply fan and exhaust free and supply free and exhaust fan. Recently, the individual ventilation system and central ventilation system which is combined cooling system with duct system are applied to apartment ventilation system. The airflow pattern is affected by location of supply unit and exhaust unit in indoor. This study is to investigate the proper distance between supply unit and exhaust unit using CFD. As a result of this study, the proper distance between supply unit and exhaust unit could be suggested at the interval of 3 m in supply and exhaust fan system and 2.5 m in supply fan and exhaust free.

초고층 공동주택의 하이브리드 환기시스템의 성능평가에 관한 연구 (A study on the Performance of Hybrid ventilation system in High-rise Apartment Houses)

  • 김옥;박창봉;박진철;김남규;이언구
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.113-118
    • /
    • 2007
  • As the economic living standards are higher, the demands for more comfortable living space are also larger. In the response of this requirements, studies for improving indoor air environment have been conducted. In case of newly-built apartment buildings, the standard for the minimum ventilation to improve their indoor air quality was made. This study analysed the experimental results from the mock-up test of the hybrid ventilation system which is composed of natural and mechanical ventilation.

  • PDF

오염발생원의 위치인식에 의한 환기장치 제어방안 (Ventilation System Control by Location-Aware of Pollution Source)

  • 한화택;한정일;권용일
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.405-410
    • /
    • 2006
  • This paper presents a control algorithm of supply and exhaust diffusers by recognizing a contaminant source location. CFD analysis has been conducted to calculate steady state airflow and concentration distributions in a model room, which has two supply and two exhaust openings on the ceiling. Calculations have been performed for five cases out of nine different ventilation modes by combining on/off control of the supply and exhaust openings. Local mean residual life times are obtained and compared at 9 internal points for each ventilation case. Depending on the contaminant source location, the ventilation system is operated at an optimum ventilation mode, which can results in maximum exhaust performance.

  • PDF