전동차 출입문 개폐에 따른 객실 이산화탄소 농도변화의 실험적 연구 (Experimental Study on $CO_2$ Level Fluctuation by Door-opening of Subway)

  • 권순박;박덕신;조영민;박은영;김세영;정미영;함대주
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.1652-1655
    • /
    • 2008
  • Indoor air quality (IAQ) of subway becomes a key issue as the IAQ guidelines for public transportation published. There are two major sources regarding IAQ of subway; One is the sources coming from outdoor air and the other is sources of inside. Particulate matters smaller than 10 micrometer (PM10) and carbon dioxide ($CO_2$) are recognized as the one of the most severe pollutants in Korea. The source of PM10 is mainly coming from outdoor air, however, the source of $CO_2$ is coming from passengers exhaust. According to the guidelines, the level of $CO_2$ should be lower than 2500ppm for normal operating time and lower than 3500ppm for rush hour. In order to satisfy these guidelines, the volume of mechanical ventilation should be increase which consumes extra energy for heating or cooling. Therefore, the optimum volume of mechanical ventilation should be calculated for energy saving. In this study, we measured the natural ventilation rate by door-opening which can reduce the load of mechanical ventilation. The $CO_2$ generator and sensors were used to measure the change of $CO_2$ by periodic door-opening of subway.

  • PDF

강의실에서 환기시스템과 난방시스템의 풍량에 따른 PMV와 $CO_2$ 농도 특성 비교 (Comparison of the PMV and $CO_2$ concentration Characteristic in the Lecture Room with a Different Airflow rate of the Ventilation System and Heating System for heating season)

  • 한창우;노광철;오명도
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.411-416
    • /
    • 2006
  • In this paper, we performed the experimental and numerical study on the thermal comfort(TC) and indoor air quality(IAQ) in the lecture room with a different airflow rate of the ventilation system and heating system for heating season. Through the experimental results, we found out that there was considerably difference of the PMV but there was little difference of $CO_2$ concentration with a different heating system. From a numerical results, the best operating condition was that discharge airflow rate of SAC is 29 CMM and supply airflow rate of the ventilation system is 1,200 CMH from a viewpoint of TC and IAQ.

  • PDF

공동주택에서 환기장치류 가동특성에 따른 실내공기질 변화특성에 관한 연구 (The Effects to Indoor Air Quality as Ventilation System Operation in Apartment House Using CFD Simulation)

  • 김석근;이정재
    • 설비공학논문집
    • /
    • 제19권2호
    • /
    • pp.142-148
    • /
    • 2007
  • The purpose of this study is to suggest the effective ventilation strategies and control methods that can minimize energy cost maintaining acceptable IAQ level in apartment house. The effects of the air-cleaning and heat-recovery ventilation system on IAQ under various operating conditions are investigated based on the experimental and CFD analyzed results. The results can be summarized as follows. (1) When a ventilator is not operated, the concentration of several pollutants may highly show in the house even though environment-friendly building materials are applied. Therefore, a mechanical ventilation system is required to obtain proper ventilation. (2) The pollutant concentration is noticeably deceased under air-cleaning/ventilation mode of air-clinic system, however, pollutant of kitchen is stagnant, because fresh air is not carried into the kitchen. (3) When air-clinic system is only equipped at master bedroom and living room, the system does not effectively deliver fresh air throughout the whole house, and then high pollutant concentration is obtained in each room. In contrast the average pollutant concentration meets the guideline when air-clinic system is installed at each room. (4) The air-cleaning/ventilation mode significantly affects on room ventilation in comparison with ventilation mode only.

Mechanical ventilation-associated pneumothorax presenting with paroxysmal supraventricular tachycardia in patients with acute respiratory failure

  • Eom, Jeong Ho;Lee, Myung Goo;Lee, Chang Youl;Kwak, Kyong Min;Shin, Won Jae;Lee, Jung Wook;Kim, Seong Hoon;Choi, Sang Hyeon;Park, So Young
    • Journal of Yeungnam Medical Science
    • /
    • 제32권2호
    • /
    • pp.106-110
    • /
    • 2015
  • The prevalence of pneumothorax cases among Intensive Care Unit patients who require mechanical ventilation ranges from 4%-15%. A pneumothorax remains one of the most serious complications of positive pressure ventilation. It can be diagnosed in a critically ill patient through a physical examination or radiographic studies that include chest radiographs, ultrasonography, or computed tomography scanning. However, in a critically ill patient, the diagnosis of a pneumothorax is often complicated by other diseases and by difficulties in imaging sick and unconscious patients. Although electrocardiogram changes associated with a pneumothorax have been described for many years, there has been no report of such among patients who require mechanical ventilation. In this paper, we report 2 cases of a spontaneous pneumothorax with paroxysmal supraventricular tachycardia in patients who required invasive mechanical ventilation due to acute respiratory failure.

건강주택 실현을 위한 공동주택 거주자의 환기행태 및 환기기기 관리 특성에 관한 연구 (The Characteristics of Behavior for Ventilation and Maintenance for Ventilation Equipments by Multi-family Housing Residents to Actualize Healthy Housing)

  • 이윤재
    • 한국주거학회논문집
    • /
    • 제21권5호
    • /
    • pp.93-101
    • /
    • 2010
  • The purpose of the study is to investigate the behaviors for ventilation to control indoor air quality and characteristics of the maintenance for ventilation equipments by multi-family housing residents. This study was conducted by the survey in the area of Seoul and Kyungki-do. The results of the study are as follows: the majority of respondents conduct ventilation once a day, below 20 minutes with opening some windows of the inside of the house. The time for ventilation is generally between 9-11 am. and 5-7 pm. Most of the wives are responsible for ventilation activities. In addition, so far building materials and furniture are not seriously considered as the source of indoor air pollution by the respondents. Their satisfaction for indoor air before and after ventilation is perceived as just the level of average. As the mechanical ventilation equipments such as a hood and an exhaust fan, half of the respondents are using them frequently. However, the ventilation equipments are not maintained well. Specially maintenance and checks for exhaust fans are hardly conducted. In conclusion, the frequency of ventilation is very limited and residents show passive attitudes about ventilation and maintenance of ventilation equipments. Therefore, for the actualization of healthy housing, educational programs and guidelines on the way of ventilation targeting the residents should be set up and a certain organization has to check periodically the performance of the ventilation equipments of each house in the multi-family housing complex.

급기-흡기 국소환기시스템의 성능개선에 관한 수치해석 (Numerical Analysis on the Improvement of Fume Mixing Ratio in the Push-Pull Local Ventilation System)

  • 이중섭;서정세;윤지훈
    • 설비공학논문집
    • /
    • 제22권12호
    • /
    • pp.867-872
    • /
    • 2010
  • Numerical analysis has been conducted to investigate the fluid flow and fume mixing ratio characteristics of scattering fume in a push-pull ventilation system and optimally improve the flow patterns of scattering fume in the existing ventilation system. This ventilation system has been simulated by using commercial CFD code. In the case of the existing system, although the air is sprayed from air-curtain to prevent the fume from being scattered in upper hood, the improved air supply hood can remove the fume from the wide area in the high pressure. It is verified that the deeper plating storage is more advantageous. Also, by installing the shied around the plating storage, the scattering of the fume to the atmosphere was prevented effectively by surrounding flux.

유조선 화물취급구역내 동력환기특성에 관한 연구 (A Study on Mechanical Ventilation Characteristics in Cargo Handling Area of Tanker)

  • 조대환
    • 해양환경안전학회지
    • /
    • 제7권1호
    • /
    • pp.15-23
    • /
    • 2001
  • In regulation of IGC code 12.1 mechanical ventilation should be arranged to ensure sufficient air movement through the space to avoid the accumulation of flammable or toxic vapours and ensure a safe working environment, but in no case should the ventilation system have a capacity of less than 30 changes of air per hour baed upon the total volume of the space. In this study, a scaled mode chamber was constructed to investigate the ventilation characteristics and stagnation area in the hood room of LNG carrier and pump room in tanker. An experimental study was performed on the model by using visualization equipment with a laser apparatus and an image intensifier CCD camera. Twelve different kinds of measuring areas were selected as the experimental condition. Instant simultaneous velocity vectors in the whole fields were measured by a 2-D PIV system A three-dimensional numerical simulation was also carried out for three different Reynolds numbers. Then the CFD predictions were discussed with the experimental results. The results show the spiral L-shape flow that moves from the opening on the left wall diagonally to the upper right part dominates the ventilation structure. The stationary area of hood room in the velcoity distributions was located in the upper left stern part.

  • PDF

제트 팬 위치에 따른 곡선형 장대터널의 환기해석 (Ventilation Analysis According to Jet Fan Location in Curved Long Road Tunnel)

  • 변주석;강신형;김지성;이진호
    • 설비공학논문집
    • /
    • 제19권9호
    • /
    • pp.669-678
    • /
    • 2007
  • In this study, the ventilation characteristics is investigated numerically of the longitudinal ventilation method in the curved long road tunnel. Numerical work has been conducted for the jet fan location by utilizing the commercial finite-volume code, FLUENT. Configuration of the tunnel is three-lane, 1600 m long, $120m^2$ in area, 3000 m curvature radius. The velocity profile, distribution of mono-dioxide carbon and flow rate of air are examined in the tunnel. Through the analysis, it is found that the difference of ventilation flow rate Is a little by the jet fan location, but tunnel outlet setup (CASEIII) of jet fans is the most efficient concerned with CO concentration.

PDP용 배기로내 열전달 현상 해석 (Heat Transfer Analysis in a PDP Ventilation Chamber)

  • 박형규;정재동;김찬중;이준식;박희재;조영만;조해균;박득일
    • 대한기계학회논문집B
    • /
    • 제25권3호
    • /
    • pp.347-355
    • /
    • 2001
  • A heat transfer analysis in a ventilation chamber of Plasma Display Panel(PDP) has been conducted. The process requirement is to precisely follow prescribed temperature trajectory while maintaining temperature uniformity for each panel. Firstly, experiment in a test chamber has been carried out and the results are compared with the unsteady 3D numerical data. Reasonable agreement was found, which suggested that the employed numerical model had its credibility in actual PDP ventilation processes. On this ground, a tact-type heating/cooling system was analyzed. The panel temperature in the 40$^{\circ}C$ tact-type system was more uniform than that in the 80$^{\circ}C$ one. For improving the uniformity of panel temperature, relocation of ventilation head to the rear part and inlet flow control are required. Comparison of full simulation of a cart and simplified simulation of one panel indicates the optimized panel pitch can also be predicted.

장대형 터널 내 제트 팬 위치에 따른 환기해석 (Ventilation Analysis according to Jet Fan Location in Long Tunnel)

  • 강신형;변주석;이진호
    • 설비공학논문집
    • /
    • 제19권5호
    • /
    • pp.386-393
    • /
    • 2007
  • This paper studies the ventilation characteristics according to the jet fan location at the long road tunnel using the CFD software 'FLUENT' which is based on the finite volume method. The tunnel model used in the analysis has a length of 1600m, a cross sectional area of $120m^3$, and is composed of 3 lanes and one way. The velocity profile, the distribution of CO concentration and the ventilation flow rate within the tunnel are analyzed, respectively. In the analysis, it is found that the dependence of the ventilation flow rate upon the jet fan location is small, but the CO concentration in the tunnel is at the lowest when the jet fans are installed near the tunnel outlet. An air stream right below the jet fan is almost inactive due to the strong stream injection near the jet fan. Thus, the pollution level below the jet fan must be higher than the other area.