• Title/Summary/Keyword: Mechanical Stress

Search Result 7,841, Processing Time 0.044 seconds

Expression of UNC-50 DNA in periodontal tissue of rats after application of intermittent orthodontic force (간헐적 교정력 적용 후 백서 치주인대에서 UNC-50 유전자의 발현)

  • Park, Mi-Kyoung;Lim, Sung-Hoon;Kim, Kwang-Won;Park, Joo-Cheol
    • The korean journal of orthodontics
    • /
    • v.36 no.4
    • /
    • pp.242-250
    • /
    • 2006
  • Objective: Periodontal ligament fibroblasts have an ectomesenchymal origin and are thought to play a crucial role for not only homeostasis of periodontal tissues but also bone remodeling, wound healing and regeneration of tissues. Recently, it has been reported that UNC-50 is not expressed in gingival fibroblasts but in PDL fibroblasts. The purpose of this study was to examine the expression of UNC-50 and osteocalcin in the periodontium after application of intermittent force. Methods: Twelve rats had 40 grams of mesially-directed force applied at the upper molar for 1 hour/day. Four rats were sacrificed at 1, 3 and 5 days. Immunohistochemical localization of UNC-50 and osteocalcin antibody was carried out. The results showed apposition of new cellular cementum and a slight increase in periodontal space at the tension side. Results: Strong UNC-50 expression was observed in the differentiating cementoblasts close to PDL fibroblasts in the tension side whereas it was barely expressed at the compression side. Expression was strong at day 3, and decreased at day 5. Osteocalcin immunoreactivity expression was strong in differentiating cementoblasts at the tension side. Conclusion: It can be suggested that UNC-50 is related to the differentiation of cementoblasts, and may be responsible for the molecular event in PDL cells under mechanical stress.

Studies on the Effect of Fiber Reinforcing upon Mechanical Properties of Concrete and Crack Mode of Reinforoed Concrete (섬유보강이 콘크리트의 역학적 특성과 철근콘크리트의 균열성상에 미치는 영향에 관한 연구)

  • 박승범
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.20 no.2
    • /
    • pp.4645-4687
    • /
    • 1978
  • This study was attempted to investigate the mechanical properties of concrete and crack control effects of reinforced concrete with steel and glass fiber. The experimental program includes tests on the properties of fresh concrete containing fibers, compressive strength, tensile strength, flexural strength, Young's modulus, Shrinkage and deformation of steel or glass fiber reinforced concrete. Also this study was carried out to investigate the effect of steel or glass fiber to retard the development in reinforced concrete subject to uniaxial tension and thus facilitate the use of steels of higher strength. The major conclusions that can be drawn from the studies are as follows: 1. The effect of the fibers in various mixes on fresh concrete confirmed that fibers do have a significant effect on the properties of fresh concrete, bringing much more stable and exhibiting a signiflcant reduction in surface bleeding, and that the cohesion is greatly improved and the internal resistance increases with fiber concentration. But the addition of an excess contents and length of fibers brings about the reduction of workability. 2. With the addition of steel fibers(1.5% Vol.) to concrete, the compressive strength as compared with plain concrete showed a very slight increase, but excess addition, over 1.5% Vol. of steel and glass fiber reduced its strength. 3. Splitting tensile strength of fiber reinforced concrete showed a significant increase tendency, as compared with plain concrete. In case of containing steel fiber (2.5%, 30mm), it showed that the maximum increase rate of 1.48 times as much rate, and in case of containing glass fiber (2.5%, 30mm), the increase rate of strength was 1.25 times as much rate. 4. Flexural strength of fiber reinforced concrete showed a significant tendency, as compared with plain concrete. Containing steel fiber (2.5%, 30mm) showed the maximum increase rate of 1.64 times as much rate and containing glass fiber (2.5%, 30mm) showed the increase rate of strength of 1.32 times as much rate, and in general, the 30mm length brougth the best results. 5. The strength ratio ($\sigma$b/$\sigma$c and $\sigma$t/$\sigma$c) increased, when steel fiber's average spacing was up to 3.05mm, but decreased when beyond 3.05mm, and it was confirmed that tensile or flexural strengths of steel fiber reinforced concrete are apparently governed by fiber's average spacing. 6. The compressive strain of fiber reinforced concrete showed a significant increasing tendency as the fiber was added, but Young's modulus. with the addition of steel and glass fibers, showed a slight decrease tendency. And according to the increase of flexural strength, a considerable increase was seen in toughness. 7. With the addition of fiber's the shrinkage of concrete was significantly decreased, in both case of adding steel fibers 12.5%, 30mm, and showed a significant decrease ratio, in average 30.4% and 36.7%, as compared with plain concrete. 8. With the increase of fiber volume fraction and length, the gained stress in reinforcing bar in concrete specimens increased in all crack widths, but at different rates, with the decrease of fiber diameter, the stress showed a considerable increasing tendency. And the duoform steel fibers showed the greatest improvement, as compared with the other types tested. 9. The influence of fiber dimensions in order of significanse on the machanical properties of concrete and the crack control of reinforced concrete was explained as follows: content, length, aspect ratio and dimeter.

  • PDF

Clinical Results of ACL Reconstruction in the Immature Adolescent via Transphyseal Approach in Tibia Based on a New Indication Paradigm (새로운 수술적응증에 의한 골 미성숙 전방십자인대 손상 환자에서의 성장판을 통과하는 전방십자인대 재건술의 결과)

  • Lee, Dong Chul;Shon, Oog Jin;Park, Chul-Hyun;Kwon, Moon Soo
    • Journal of the Korean Arthroscopy Society
    • /
    • v.16 no.1
    • /
    • pp.1-8
    • /
    • 2012
  • Purpose: To evaluate clinical and radiologic outcomes of transphyseal anterior cruciate ligament (ACL) reconstruction in patients with open physes who were selected with authors' new operative indications. Materials and Methods: We evaluated 15 patients with open physes who underwent a transtibial ACL reconstruction and were followed up for 4~6 years after surgery. Our operative indications involved 1) choronologic age of ${\geq}$ 16 in male and ${\geq}$ 14 in female, 2) open physes of ${\leq}$ 2 mm width, and 3) Risser sign and Tanner stage of ${\geq}$ 3. Tibialis anterior tendon allograft was used in all patients, and endobutton and bioscrew were used for femoral and tibial fixations, respectively. Functional outcomes were evaluated using Lysholm Knee Scoring scale, Tegner activity scale, and International Knee Documentation Committee (IKDC) 2000 subjective score. Physical examinations to evaluate stability involved Lachman and pivot shift tests. For radiographic results, we evaluated side to side differences of anterior displacement in stress views. In addition, with use of scannograms taken at last follow-up, we examined side to side differences of femorotibial angles, anatomical and mechanical lateral distal femoral angles, mechanical medial proximal tibial angles and leg lengths. Results: The mean Lysholm Knee score was 51(40-61) points preoperatively and 97(94-100) points at last follow up. The mean Tegner activity score was 2.6 points preoperatively and 7.1 points at last follow up. The mean IKDC score was 32.6 points preoperatively and 88.3 points at last follow up. The mean anterior displacement of the tibia was improved from 6.7(${\pm}1.0$) mm to 1.9(${\pm}0.9$) mm. There were no leg length discrepancies over 5 mm and no statistically significant differences in all the radiographic variables representing growth disturbance. Conclusion: This study suggests that patients with open physes who selected by authors' new indication would safely undergo transphyseal ACL reconstruction with successful outcomes.

  • PDF

The effect of labial inclination on intrusion of the upper and lower incisors by three-dimensional finite element analysis (분절호선법으로 상하악 절치부 압하 시 순측경사도가 미치는 영향에 관한 3차원 유한요소법적 연구)

  • Kim, Dong Woo;Yang, Hoon Chul;Kim, Gi Tae;Kim, Sung Sik;Son, Woo Sung
    • The korean journal of orthodontics
    • /
    • v.33 no.4 s.99
    • /
    • pp.259-277
    • /
    • 2003
  • This study was designed to investigate the position of anteroposterior center of resistance for genuine intrusion and the mode of change of the minimum distal force for simultanous intrusion and retraction of the upper and lower incisors according to the increase of labial inclination. For this purpose, we used the three-piece intrusion arch appliance and three-dimensional finite element models of upper and lower incisors. 1. Positions of the center of resistance in upper incisors according to the increase of the labial inclination were as follows; 1) In normal inclination situation, the center of resistance was located in 6m behind the distal surface of the lateral incisor bracket. 2) In $10^{\circ}$ increase of the labial inclination situation, the center of resistance was located in 9mm behind the distal surface of the lateral incisor bracket. 3) In $20^{\circ}$ increase of the labial inclination situation, the center of resistance was located in 12m behind the distal surface of the lateral incisor bracket. 4) In $30^{\circ}$ increase of the labial inclination situation, the center of resistance was located in 16m behind the distal surface of the lateral incisor bracket. 2. Positions of the center of resistance in lower incisors according to the increase of the labial inclination were as follows; 1) In normal inclination situation, the center of resistance was located in 10mm behind the distal surface of the lateral incisor bracket. 2) In $10^{\circ}$ increase of the labial inclination situation, the center of resistance was located in 13m behind the distal surface of the lateral incisor bracket. 3) In $20^{\circ}$ increase of the labial inclination situation, the center of resistance was located in 15m behind the distal surface of the lateral incisor bracket. 4) In $30^{\circ}$ increase of the labial inclination situation, the center of resistance was located in 18m behind the distal surface of the lateral incisor bracket. 3. The patterns of stress distribution were as follows; 1) There were even compressive stresses In and periodontal ligament when intrusion force was applied through determined center of resistance. 2) There were gradual increase of complexity in compressive stress distribution pattern with Increase of the labial inclination when intrusion and retraction force were applied simultaneously. 4. With increase of the labial inclination of the upper and lower incisors, the position of the center of resistance moved posteriorly. And the distal force for pure intrusion was increased until $20^{\circ}$increase of the labial inclination.

Effect of Ta/Cu Film Stack Structures on the Interfacial Adhesion Energy for Advanced Interconnects (미세 배선 적용을 위한 Ta/Cu 적층 구조에 따른 계면접착에너지 평가 및 분석)

  • Son, Kirak;Kim, Sungtae;Kim, Cheol;Kim, Gahui;Joo, Young-Chang;Park, Young-Bae
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.28 no.1
    • /
    • pp.39-46
    • /
    • 2021
  • The quantitative measurement of interfacial adhesion energy (Gc) of multilayer thin films for Cu interconnects was investigated using a double cantilever beam (DCB) and 4-point bending (4-PB) test. In the case of a sample with Ta diffusion barrier applied, all Gc values measured by the DCB and 4-PB tests were higher than 5 J/㎡, which is the minimum criterion for Cu/low-k integration without delamination. However, in the case of the Ta/Cu sample, measured Gc value of the DCB test was lower than 5 J/㎡. All Gc values measured by the 4-PB test were higher than those of the DCB test. Measured Gc values increase with increasing phase angle, that is, 4-PB test higher than DCB test due to increasing plastic energy dissipation and roughness-related shielding effects, which matches well interfacial fracture mechanics theory. As a result of the 4-PB test, Ta/Cu and Cu/Ta interfaces measured Gc values were higher than 5 J/㎡, suggesting that Ta is considered to be applicable as a diffusion barrier and a capping layer for Cu interconnects. The 4-PB test method is recommended for quantitative adhesion energy measurement of the Cu interconnect interface because the thermal stress due to the difference in coefficient of thermal expansion and the delamination due to chemical mechanical polishing have a large effect of the mixing mode including shear stress.

THE EFFECT OF ALTERED FUNCTIONAL FORCE ON THE EXPRESSION OF SPECIFIC MRNAS IN THE DEVELOPING MOUSE MANDIBLE (하악골의 발육중인 생쥐에서 기능력의 변화가 특이-유전자 발현에 미치는 영향)

  • Kim, Hyung-Tae;Park, Joo-Cheol;Lee, Chang-Seop;Park, Heon-Dong
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.2
    • /
    • pp.308-319
    • /
    • 2003
  • Mechanical forces are known to have an effect on bone formation, maintenance and remodeling, and there is evidence that the development of the mandibular condyle in the rat or mouse is influenced by altered functional force. However, studies are lacking in molecular-biologic mechanism such as the identification of differentiation factor induced from functional force. Here a mouse model was used to investigate the functional stress-responsive gene or factors which is related to the altered force by comparing the expression genes of functional state and hypo-functional state of the mouse mandible. ICR mice were provisioned with either a soft, mushy diet (soft-diet group) or hard rat pellets (hard-diet group) beginning at weaning for the alteration of functional force and subsequently sacrificed at 89 days of age. Incisor of mice in group 1 were trimmed twice a week to reduce occlusal forces. After killing the animals, mandibular bone including condyle were collected for RNA extraction, subtractive hybridization, northern blot analysis and mRNA in-situ hybridization. The results as follows; 1. A total of 39 clones were sequenced, and 11 individual sequence types were subsequently identified by subtractive hybridization, as 28 clones were represented twice in the analyzed sets. 2. Consequently four candidate clones, FS-s (functional stress-specific)2, -5, -18, and -22 were identified and characterized by homolgy search and northern analysis. Four of these clones, FS-s2, -5, -18, and -22, were shown to be expressed differentially in the hard-diet group. 3. Histologic sections showed that osteoblastic activity along the bone trabeculae and active bone remodeling were significantly lower in soft than in hard diet animals. A soft diet seems to enable a longer period of endochondral ossification in the mandibular condyle. 4. Although the mRNAs of FS-s2, -5, -18, and -22 were expressed rarely by cells of the soft-diet group, highest expression was detected in the cells of the hard-diet group. Together with the above results, it is suggested that FS-s2, -5, -18, and -22 could act as an important factors controlling the tissue changes in response to functional stress. The exact functional significance of these findings remains to be established.

  • PDF

Three point bending test of recycled Nickel-Titanium alloy wires (재생한 니켈 티타늄 호선의 3점 굴곡물성실험)

  • Lee, Sung-Ho;Chang, Young Il
    • The korean journal of orthodontics
    • /
    • v.30 no.6 s.83
    • /
    • pp.731-738
    • /
    • 2000
  • The purpose of this study was to investigate the change of 3 point bending properties of various nickel titanium wires after recycling. Four Types of nickel-titanium (Align: martensitic type, NiTi, Optimalloy, Sentalloy: austenitic type) wires were divided to three groups: as-received condition (T0: control group), treated in artificial saliva for four weeks (T1) and autoclaved after being treated in artificial saliva (T2). Detrimental changes were observed for the selected mechanical properties in three point bending test. Loading force at 3mm deflection, unloading force at 3mm deflection, stress hysteresis, loading force at 1mm deflection, unloading force at 1mm deflection and stress hysteresis at 1mm deflection were calculated. The findings suggest that : 1. Align demonstrated statistically significant increase In loading force (p<0.05) and unloading force (p<0.01) at 3mm deflection after recycling(T2), but NiTi, Optimalloy and Sentalloy showed no statistically difference after recycling. 2. Align demonstrated statistically significant decrease in hysteresis(p<0.01) after recycling(T2) but NiTi, Optimalloy and Sentalloy showed no statistically significant difference after recycling. 3. All wires showed no statistically significant difference in loading force at 1mm deflection after recycling(T2). 4. Align demonstrated statistically significant decrease in unloading force in 1mm deflection (p<0.05) after recycling(T2) but NiTi, Optimalloy and Sentalloy showed no statistically difference after recycling 5. Loading force and unloading force of T1 showed no significant change compared with those of T0, but loading force and unloading force of T2 showed significant changes compared with those of T0(p<0.05, p<0.01 respectively). 6. Align demonstrated a tendency to lose some of this pseudoelasticity in T1 and pseudoplasticity and pseudoelasticity in T2.

  • PDF

Analysis on dynamic numerical model of subsea railway tunnel considering various ground and seismic conditions (다양한 지반 및 지진하중 조건을 고려한 해저철도 터널의 동적 수치모델 분석)

  • Changwon Kwak;Jeongjun Park;Mintaek Yoo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.25 no.6
    • /
    • pp.583-603
    • /
    • 2023
  • Recently, the advancement of mechanical tunnel boring machine (TBM) technology and the characteristics of subsea railway tunnels subjected to hydrostatic pressure have led to the widespread application of shield TBM methods in the design and construction of subsea railway tunnels. Subsea railway tunnels are exposed in a constant pore water pressure and are influenced by the amplification of seismic waves during earthquake. In particular, seismic loads acting on subsea railway tunnels under various ground conditions such as soft ground, soft soil-rock composite ground, and fractured zones can cause significant changes in tunnel displacement and stress, thereby affecting tunnel safety. Additionally, the dynamic response of the ground and tunnel varies based on seismic load parameters such as frequency characteristics, seismic waveform, and peak acceleration, adding complexity to the behavior of the ground-tunnel structure system. In this study, a finite difference method is employed to model the entire ground-tunnel structure system, considering hydrostatic pressure, for the investigation of dynamic behavior of subsea railway tunnel during earthquake. Since the key factors influencing the dynamic behavior during seismic events are ground conditions and seismic waves, six analysis cases are established based on virtual ground conditions: Case-1 with weathered soil, Case-2 with hard rock, Case-3 with a composite ground of soil and hard rock in the tunnel longitudinal direction, Case-4 with the tunnel passing through a narrow fault zone, Case-5 with a composite ground of soft soil and hard rock in the tunnel longitudinal direction, and Case-6 with the tunnel passing through a wide fractured zone. As a result, horizontal displacements due to earthquakes tend to increase with an increase in ground stiffness, however, the displacements tend to be restrained due to the confining effects of the ground and the rigid shield segments. On the contrary, peak compressive stress of segment significantly increases with weaker ground stiffness and the effects of displacement restrain contribute the increase of peak compressive stress of segment.

Comparative Study on Mechanical Properties and Dimensional Stability of Staypak and Wood-Polymer Composites from Populus alba × P. Glandulosa wood (현사시나무로 제조(製造)된 열압축목재(熱壓縮木材)와 목재(木材)-고분자(高分子) 복합체(複合體) 재질(材質)의 비교연구(比較硏究))

  • Pak, Sang-Bum;Ahn, Won-Yung
    • Journal of the Korean Wood Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.14-34
    • /
    • 1985
  • One of the techniques for altering the properties of wood that has received considerable attention in the last twenty years is the formation of a wood-polymer composite (WPC) by irradiation and heat-catalyst polymerization of a monomer incorporated into the wood matrix. Wood-polymer composites are the new products having the superior mechanical and physical properties and the combinated characteristics of wood and plastic. The purpose of this experiment was to obtain the basic data for the improvement of wooden materials by manufacturing WPC and Staypak. The species examined was Hyunsasi-Namoo (Populus alba ${\times}$ P. glandulosa) which had not been utilized yet. Methylmethacrylate (MMA) as monomer, benzoyl peroxide (BPO) as initiator and methyl alcohol as bulking agent were used. The monomer containing BPO was impregnated into wood pieces by the dipping and the vacuum process for 2 hours. After impregnation, the treated samples were polymerized on the hot press with pressure and heat-catalyst methods. The results obtained were summarized as follows 1. The monomer loading into wood by the dipping process was 12.13 percent and 29.99 percent by the vacuum. The polymer loading into wood by the dipping process was 6.79 percent and 15.44 percent by the vacuum. 2. Comparing with Staypak, antishrink efficiency (ASE) of WPC was 12.5 to 13.6 percent on the radial direction and 14.70 to 18.63 percent on the tangential. Antiswelling efficiency (AE) was 14.40 to 17.22 percent on the radial direction and 17.18 to 42.1 8 to 42.14 percent on the tangential. Reduction in water absorptivity (RWA) was 8.19 to 15.5 percent. As a whole, the vacuum process was better than the dipping. 3. The specific gravity of control, Staypak and WPC were 0.44, 0.66 and 0.61 to 0.62, respectively. 4. In the bending strength test, the strength in case that the load direction is on the radial surface was greater than that which the load direction is on the tangential. 5. Increasing rate of stress at proportional limit in compression perpendicular to grain was 72.26 percent in case of WPC by the dipping process, 78.93 percent by the vacuum and 99.09 percent in case of Staypak.

  • PDF

CNT-Ni-Fabric Flexible Substrate with High Mechanical and Electrical Properties for Next-generation Wearable Devices (차세대 웨어러블 디바이스를 위한 높은 기계적/전기적 특성을 갖는 CNT-Ni-Fabric 유연기판)

  • Kim, Hyung Gu;Rho, Ho Kyun;Cha, Anna;Lee, Min Jung;Ha, Jun-Seok
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.27 no.2
    • /
    • pp.39-44
    • /
    • 2020
  • Recently, numerous researches are being conducted in flexible substrate to apply to wearable devices. Particularly, Conductive substrate researches that can implement the wearable devices on clothing are massive. In this study, we formed fiber substrate spraying CNT and Pd mixed solution on it and plated metal layer with electroless plating. Used SEM equipment and EDS analysis to analysis structure of the plated fiber substrate and discovered Ni layer was created. For check electrical properties, mapping was performed to check surface resistance and distribution of resistance of electroless plated fiber substrate with 4-point probe. It was confirmed that conductivity was improved as the duration of electroless plating was increased, and it was found that distribution of resistance by surface location was uniform. Changes in resistance due to mechanical stress were measured through tensile, bending, and twisting tests. As a result, it was confirmed that resistance change of flexible substrate gradually disappeared as plating time increased. Using UTM (Universal testing machine), it was analyzed mechanical properties of the electroless plated substrate with respect to changes in plating time were improved. In the case of conductive fiber substrate in which electroless plating was performed for 2 hours, tensile strength was increased by 16 MPa than fiber substrate. Based on these results, we found that Ni-CNT-Fabric flexible substrate is adequate for clothing-intergrated conductive substrate and we positively expect that this experiment shows flexible substrate can adapt to and develop not only a wearable device technology but also other fields needing flexibility such as battery, catalyst and solar cell.