• Title/Summary/Keyword: Mechanical Failure

Search Result 3,003, Processing Time 0.032 seconds

Efficacy of Early Steroid Therapy in Acute Interstitial Pneumonia (급성 간질성 폐렴에서 조기 부신피질호르몬 치료의 효과)

  • Lee, Kye-Young;Jee, Young-Koo;Kim, Youn-Seup;Myong, Na-Hye;Park, Jae-Seuk
    • Tuberculosis and Respiratory Diseases
    • /
    • v.52 no.5
    • /
    • pp.519-528
    • /
    • 2002
  • Background : Steroid therapy has been shown to improve the clinical outcome in acute respiratory distress syndrome (ARDS) patients with histological evidence of fibroproliferation in the lung tissue and no identifiable source of infection. Because the histopathological features of acute interstitial pneumonia(AIP) are identical with that of ARDS, early steroid therapy was used in AIP patients who had histological evidence of fibroproliferation in the lung tissue and no identifiable source of infection. We analyzed seven years of our experience to evaluate the efficacy of early steroid therapy in AIP. Materials and Methods : A retrospective review was performed on AIP patients who received steroid therapy within 7 days of mechanical ventilatory support in Dankook university Hospital between May 1995 and May 2002. AIP was diagnosed clinically by ARDS without a known cause of the etiology and pathologically by a lung biopsy showing a fibroproliferative stage of diffuse alveolar damage. The clinical response and physiologic parameters were evaluated during steroid therapy. Results : Five AIP patients received intravenous methylprednisolone (1-2 mg/kg every 6 hours) after $0.6{\pm}1.7$ days of mechanical ventilatory support. Lung biopsies were performed after $1.8{\pm}1.4$ days of mechanical ventilatory support. Four patients(80%) survived and were extubated after $2.8{\pm}0.4$ days of steroid therapy with improvement in the $PaO_2/FiO_2$ ratio ($127.4{\pm}10.0$ at day 0 to $223.8{\pm}37.6$ at day 7) by steroid therapy. However, one patient(20%) died of respiratory failure after 15 days of steroid therapy. Conclusion : Early steroid therapy sppears to be beneficial in AIP patients without evidence of infection. However, as our study group was too small, further large scale studies to define the effectiveness of steroids are required.

Peripheral Neutrophil Count and Respiratory Failure in Preterm Infant (조산아에서 말초혈액 중성구수와 호흡 부전증과의 연관성)

  • Lee, Kum Joo;Yun, Soo Young;Lee, Ran;Hean, Jae Ho;Jung, Ghee Young;Park, Jin Hee;Park, Young Sun
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.5
    • /
    • pp.596-602
    • /
    • 2002
  • Purpose : The purpose of this study was to analyze the association of peripheral neutrophil count with the development of respiratory failure in preterm infants. Methods : A retrospective study was conducted from January 1993 to December 1999 on 44 preterm infants, who were admitted to the neonatal intensive care unit of St. Francisco hospital. Preterm infants(birth weight 500 to 1,350 gm) who had a complete blood count obtained within 2 hours after delivery. Patients in the lowest of neutrophil count(early neutropenia, < $1.0{\times}10^9/L$) were compared with patients in the remaining group. Results : Low neutrophil count were transient in early neutropenia group. The concentration the circulating neutrophil count rose from $0.85{\pm}0.11{\times}10^9/L$ at average of 2 hours after delivery to $5.3{\pm}2.7{\times}10^9/L$ at 24 hours after delivery in the early neutropenia group and from $3.6{\pm}1.6{\times}10^9/L$ to $5.8{\pm}3.2{\times}10^9/L$ in the non-neutropenia group during the same time period. Compare to the non-neutropenia group, the neutropenia group had a lower birth weight($1,046.50{\pm}180.76gm$ Vs $1,156.70{\pm}124.99gm$), a lower Apgar score(1 min : $3.41{\pm}1.18$ Vs $4.30{\pm}1.46$, 5 min : $5.41{\pm}0.87$ Vs $6.15{\pm}0.95$), and a higher incidence of bronchopulmonary dysplasia(27.27% Vs 7.0%). Patients who had early neutropenia were more likely to require mechanical ventilation, supplemental oxygen and hospital stay. Also, main effect factors for the two groups were birth weight(Odds ratio=5.457, 95% CI=1.551-27.525), initial peripheral blood white cells(odds ratio=8.308, 95% CI=2.054-52.699), and bronchopulmonary dysplasia(odds ratio=0.099, 95% CI=0.017-0.397). Conclusion : A low count of neutrophil in the systemic circulation of premature infants within 2 hours of birth is associated with more severe respiratory distress.

Effect of Additional 1 hour T-piece Trial on Weaning Outcome to the Patients at Minimum Pressure Support (최소압력보조 수준에서 추가적 1시간 T-piece 시도가 이탈에 미치는 영향)

  • Hong, Sang-Bum;Koh, Youn-Suck;Lim, Chae-Man;Ann, Jong-Jun;Park, Wann;Shim, Tae-Son;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.4
    • /
    • pp.813-822
    • /
    • 1998
  • Background: Extubation is recommended to be performed at minimum pressure support (PSmin) during the pressure support ventilation (PSV). In field, physicians sometimes perform additional 1 hr T-piece trial to the patient at PSmin to reduce re-intubation risk. Although it provides confirmation of patient's breathing reserve, weaning could be delayed due to increased airway resistance by endotracheal tube. Methods: To investigate the effect of additional 1 hr T-piece trial on weaning outcome, a prospective study was done in consecutive 44 patients who had received mechanical ventilation more than 3 days. Respiratory mechanics, hemodymic, and gas exchange measurements were done and the level of PSmin was calculated using the equation (PSmin=peak inspiratory flow rate $\times$ total ventilatory system resistance) at the 15cm $H_2O$ of pressure support. At PSmin, the patients were randomized into intervention (additional 1 hr T-piece trial) and control (extubation at PSmin). The measurements were repeated at PSmm, during weaning process (in cases of intervention), and after extubation. The weaning success was defined as spontaneous breathing more than 48hr after extubation. In intervention group, failure to continue weaning process was also considered as weaning failure. Results: Thirty-six patients with 42 times weaning trial were satisfied to the protocol. Mean PSmin level was 7.6 (${\pm}1.9$)cm $H_2O$. There were no differences in total ventilation times (TVT), APACHE III score, nutritional indices, and respiratory mechanics at PSmin between 2 groups. The weaning success rate and re-intubation rate were not different between intervention group (55% and 18% in each) and control group (70% and 20% in each) at first weaning trial. Work of breathing, pressure time product, and tidal volume were aggravated during 1 hr T-piece trial compared to those of PSmin in intervention group ($10.4{\pm}1.25$ and $1.66{\pm}1.08$ J/L in work of breathing) ($191{\pm}232$ and $287{\pm}217$cm $H_2O$ s/m in pressure time product) ($0.33{\pm}0.09$ and $0.29{\pm}0.09$ L in tidal volume) (P<0.05 in each). As in whole, TVT, and tidal volume at PSmin were significantly different between the patients with weaning success ($246{\pm}195$ hr, $0.43{\pm}0.11$ L) and the those with weaning failure ($407{\pm}248$ hr, $0.35{\pm}0.10$L) (P<0.05 in each). Conclusion : There were no advantage to weaning outcome by addition of 1 hr T-piece trial compared to prompt extubation to the patient at PS min.

  • PDF

Torque and mechanical failure of orthodontic micro-implant influenced by implant design parameters (교정용 마이크로 임플란트의 디자인이 토오크와 파절강도에 미치는 영향)

  • Yu, Won-Jae;Kyung, Hee-Moon
    • The korean journal of orthodontics
    • /
    • v.37 no.3 s.122
    • /
    • pp.171-181
    • /
    • 2007
  • Objective: The present study was aimed at an analytical formulation of the micro-implant related torque as a function of implant size, i.e. the diameter and length, screw size, and the bony resistance at the implant to bone interface. Methods: The resistance at the implant to cancellous bone interface $(S_{can})$ was assumed to be in the range of 1.0-2.5 MPa. Micro-implant model of Absoanchor (Dentos Inc. Daegu, Korea) was used in the course of the analysis. Results: The results showed that the torque was a strong function of diameter, length, and the screw height. As the diameter increased and as the screw size decreased, the torque index decreased. However the strength index was a different function of the implant and bone factors. The whole Absoanchor implant models were within the safe region when the resistance at the implant/cancellous bone $(=S_{can})$ was 1.0 or less. Conclusion: For bone with $S_{can}$ of 1.5 MPa, the cervical diameter should be greater than 1.5 mm if micro-implant models of 12 mm long are to be placed. For $S_{can}$ of 2.0 MPa, micro-implant models of larger cervical diameter than 1.5 mm were found to be safe only if the endosseous length was less than 8 mm.

Nondestructive Evaluation and Microfailure Mechanisms of Single Fibers/Brittle Cement Matrix Composites using Electro-Micromechanical Technique and Acoustic Emission (Electro-Micromechanical 시험법과 Acoustic Emission을 이용한 단섬유/시멘트 복합재료의 미세파괴 메커니즘과 비파괴적 평가)

  • 박종만;이상일;김진원;윤동진
    • Composites Research
    • /
    • v.14 no.3
    • /
    • pp.18-31
    • /
    • 2001
  • Interfacial and microfailure properties of the modified steel, carbon and glass fibers/cement composites were investigated using electro-pullout test under tensile and compressive tests with acoustic emission (AE). The hand-sanded steel composite exhibited higher interfacial shear strength (IFSS) than the untreated and even neoalkoxy zirconate (Zr) treated steel fiber composites. This might be due to the enhanced mechanical interlocking, compared to possible hydrogen or covalent bonds. During curing process, the contact resistivity decreased rapidly at the initial stage and then showed a level-off. Comparing to the untreated case, the contact resistivity of either Zr-treated or hand-sanded steel fiber composites increased to the infinity at latter stage. The number of AE signals of hand-sanded steel fiber composite was much more than those of the untreated and Zr-treated cases due to many interlayer failure signals. AE waveforms for pullout and frictional signals of the hand-sanded composite are larger than those of the untreated case. For dual matrix composite (DMC), AE energy and waveform under compressive loading were much higher and larger than those under tensile loading, due to brittle but well-enduring ceramic nature against compressive stress. Vertical multicrack exhibits fur glass fiber composite under tensile test, whereas buckling failure appeared under compressive loading. Electro-micromechanical technique with AE can be used as an efficient nondestructive (NDT) method to evaluate the interfacial and microfailure mechanisms for conductive fibers/brittle and nontransparent cement composites.

  • PDF

Adenovirus Pneumonia with Respiratory Failure in Pediatric Patients (소아에서 발생한 호흡부전이 동반된 아데노 바이러스 폐렴)

  • Do, Sung Suk;Ma, Sang Hyeok;Park, Jae Sun;Lee, Young Ho;Lee, Hwan Jong;Lee, Gyu Man
    • Pediatric Infection and Vaccine
    • /
    • v.5 no.2
    • /
    • pp.258-266
    • /
    • 1998
  • Purpose : Cases of adenoviral penumonia with rapidly progressive clinical course were experienced. We reviewed these patients in viewpoint of clinical manifestation and adenoviral serotypes. Methods : Culture and indirect immunofluorescence for respiratory viruses including respiratory syncytial virus, influenza virus, parainfluenza virus, adenovirus was done with nasopharyngeal aspirates from patients who admitted due to respiratory infections in Fatima Hospital, Masan from Nov. 1996 to Jul. 1997. Cultured adenovirus was serotyped by both neutralization and hemagglutination inhibition test. Medical records were reviewed for 5 patients with respiratory failure from adenovirus was isolated and serotyped. Results : The total number of examined patients was 460 patients. We isolated respiratory viruses in 143(30.9%) patients. Adenovirus was isolated from 66 out of 143(46.2%) patients. During Jan 1997 to May 1997, five patients with ages of 18 days to 11 months who were infected by adenovirus and had high fever with dyspnea and required assisted mechanical ventilation. One patients discharged against doctor's advice then died. Two of four patients had complications of disseminated intravascular coagulation; two had bronchiolitis obliterans. Two isolates were serotype 7, and one was serotype 5, and two were untyped. Conclusion : Severe pneumonia caused by serotype 7 continued to occur in 1997 following the epidemic in 1996, and severe pneumonia may also be caused by serotype 5 and other serotypes.

  • PDF

The Changes of Physiologic Parameters with Time in Steroid treated-Late Acute Respiratory Distress Syndrome Patients (스테로이드를 투여한 후기 급성호흡곤란증후군 환자에서 시간경과에 따른 생리학적 지표의 변화)

  • Jeon, Ik Soo;Suh, Gee Young;Koh, Won-Jung;Pyun, Yu Jang;Kang, Eun Hae;Ham, Hyoung Suk;Oui, Misook;Chung, Man Pyo;Kim, Hojoong;Kwon, O Jung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.54 no.4
    • /
    • pp.429-438
    • /
    • 2003
  • Background : The mortality from acute respiratory distress syndrome(ARDS) is >40-50%. Although some prospective trials have failed to demonstrate a survival benefit of steroids in the early stages of ARDS, there are some reports showing some success with steroids in the later stages. This study observed the changes in the physiologic parameters with time in late ARDS patients who were treated with steroids. Methods : The medical charts of 28 intensive care unit patients(male:female=24:4; mean age 64 years), who had been diagnosed with refractory late ARDS ($PaO_2/FIO_2$ <200) and were treated with corticosteroids from December 1999 to July 2002, were retrospectively reviewed. The patients were divided into two groups: the weaned group(n=14), which included the patients who had been successfully weaned from a ventilator after corticosteroid therapy, and the failed group(n=14), which included the patients who had failed weaning. The physiologic parameters included the $PaO_2/FIO_2$ ratio, the positive end-expiratory pressure(PEEP) level, the $PaCO_2$, compliance, the sequential organ failure assessment(SOFA) score, the acute physiologic and the chronic health evaluation(APACHE) II score, and the Murray Lung Injury Score(LIS) in the two groups were compared from the day of mechanical ventilation(Dmv) to 7 days after the corticosteroid therapy. Results : There was no significant difference in the clinical characteristics and the physiologic parameters between the two groups prior to the corticosteroid therapy except for the SOFA score at Dmv(weaned group : $6.6{\pm}2.5$ vs failed group : $8.8{\pm}2.9$, p=0.047). However, within 7 days after corticosteroid therapy, there was significant improvement in the $PaO_2/FIO_2$ ratio, the PEEP level, the $PaCO_2$, the SOFA score, the APACHE II score, and the LIS of the weaned group compared to the failed group. Conclusions : During corticosteroid therapy in late ARDS, the continuation of corticosteroid therapy should be determined carefully in patients who do not show improvement in their physiologic parameters by day 7.

Case report: Application of Implant Supported Removable Partial Denture due to Multiple Dental Implant Loss of the Fixed Implant Supported Prosthesis (다수의 임플란트발거로 임플란트 고정성 보철이 실패한 환자에서의 잔존 임플란트를 이용한 부분 가철성 국소의치 수복증례)

  • Kang, Jeong Kyung;Nam, Gi Hoon
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.23 no.1
    • /
    • pp.34-40
    • /
    • 2014
  • There are several treatment options for rehabilitation of partial edentulism including the use of conventional or implant-retained fixed prostheses. However, such prosthetic options cannot always be possible because of compromised general and oral health (i.e. loss of supporting tissues, medical reasons, extensive surgical protocol and osseointegration failure of dental implant) as well as the affordability of patients. In some cases, removable partial denture provides easier access for oral hygiene procedures and the ability to correct discrepancies in dental arch relationships than implant fixed prosthesis. Recently, Implant Supported Removable Partial Denture (ISRPD) where to place dental implant in strategic position has been suggested to improve the limitation and shortcomings of conventional RPD. ISPRD can overcome mechanical limition of conventional RPD by placing implant in a favorable position and can be cost-effective, prosthetic solution for partially edentulous patients who are not immediate candidates for extensive, fixed implant supported restorations. Incorporation of dental implants to improve the RPD support and retention and to enhance patient acceptance should be considered when treatment planning for RPD. In this case, 59 years old male patient who received dental treatment of implant fixed prosthesis on both side of the upper jaw and implant overdenture on lower jaw showed implant abutment screw fracture on #15i and osseointegration failure on multiple number of implants. After removing failed implants, we planned ISRPD using #15i,24i,25i,26i and #23 natural tooth for RPD abutment. We fabricated #23 surveyed crown,#24i=25i=26i surveyed bridge and #15i gold coping for support,retention and stability for RPD. Periodic follow up check for 2years has been performed since the ISRPD delivery to the patient. No sign of screw loosening, fracture or bone resorption around abutment implants were detected.

Effect of Nasal Continuous Positive Airway Pressure after Early Surfactant Therapy in Moderate Respiratory Distress Syndrome (중등도 신생아 호흡 곤란 증후군에서 폐 표면 활성제 조기 투여 후 Nasal CPAP의 치료 효과)

  • Kim, Eun Ji;Kim, Hae Sook;Hur, Man Hoe;Lee, Sang Geel
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.10
    • /
    • pp.1204-1212
    • /
    • 2002
  • Purpose : Early surfactant therapy with either gentle ventilation, high-frequency ventilation or aggressive weaning of mechanical ventilation are principles for the treatment of respiratory distress syndrome(RDS). We studied to determine the accessibility of noninvasive nasal continuous positive airway pressure(CPAP) rather than mechanical ventilation by invasive intubation after early surfactant therapy. Methods : The study group consisted of 14 infants who were born and diagnosed with moderate respiratory distress syndrome and received early surfactant therapy with nasal CPAP of PEEP 5-6 cm $H_2O$ within two hours after birth in the Fatima neonatal intensive care unit for two years from January 1999 to August 2001. The control group consisted of 15 infants who were diagnosed with the disease and could be weaned from mechanical ventilator within five days after birth during the same period. Results : The characteristics, the severity of clinical symptoms and laboratory findings in the two groups at birth showed no significant difference. Neither did the interim analysis of laboratory data in two groups. Of 14 infants in the study group who received nasal CPAP after early surfactant therapy, only two infants showed weaning failure with this therapy. In the response cases, duration of CPAP was five days and mean airway pressure was $5.4{\pm}0.5cm$ $H_2O$. Two had the complication of CPAP with abdominal distension. Final complications and outcomes in the two groups showed no signifcant difference(P>0.05). Conclusion : The clinical courses in the two groups showed no significant difference. Therefore, we suggest that early surfactant therapy with noninvasive nasal CPAP is a simple and safe method rather than aggressive weaning after invasive mechanical ventilation in moderate respiratory distress syndrome.

Monotonic Loading Test for CFT Square Column-to-Beam Partially Restrained Composite Connection (CFT 각형 기둥-보 합성 반강접 접합부의 단조가력 실험)

  • Choi, Sung Mo;Park, Su Hee;Park, Young Wook;Kim, Jin Ho
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.3 s.76
    • /
    • pp.325-335
    • /
    • 2005
  • This study tackles the development of an improved detail of partially restrained CFT square column-to-beam connection and the evaluation of its mechanical behavior under monotonic loading. The connection is designed to strengthen shearing capacity at the bottom of the connection due to the ultimate behavior of PR-CC by its detail of the bottom connection and simplify the fabrication process. The suggested connection is the welded bottom beam flange connection(M-2) and is compared with the existing PR-CC of bolted seat angle connection(M-1). Two specimens were fabricated in actual size and tested under monotonic loading. Based on the test results, the welded bottom beam flange connection exhibited about 85% of the stiffness of steel beam. It was similar to the bolted seat angle connection and behaved as PR-CC. The specimen of the supposed connection type failed at the shear connection of web but was similar to the bolted seat angle connection until the failure. It obtained sufficient stiffness and capacity through the reinforcingsteel and the capacity and deformational ability equivalent to the full-plastic moment through the anchor inside the steel tube at the web connection. So, it can be said that the suggested connection exhibits sufficient ductile behavior.