• Title/Summary/Keyword: Mechanical Failure

Search Result 3,038, Processing Time 0.034 seconds

Design Optimization of M8 Blind Rivet Nut Geometry using Finite Element Analysis (유한요소해석을 이용한 M8 블라인드 리벳 너트 형상 최적 설계)

  • Gu, B.;Choi, J.M.;Hong, S.
    • Transactions of Materials Processing
    • /
    • v.29 no.3
    • /
    • pp.157-162
    • /
    • 2020
  • Blind rivet nuts are increasingly used in automotive for the joining of sheets. Their application, however, requires appropriate design guides to prevent catastrophic events arising from the failure of joints. In this study, the shaft shape of a frequently used M8 blind rivet nut is optimized based on 3D numerical analysis of the blind rivet nut considering the characteristics of thread. The thread needs to be modeled to suitably consider the fastening of the M8 bolt after the crimping process. FE analysis showed that while the friction in the contact between crimp flange and plate has no significant effect on the crimp geometry, shaft thickness (t) and shaft height (h) are the most significant design variables. The parameter study including various combinations of t and h reveals that they affect the gap (the distance between the crimped flange and the plate that develops through riveting) and the load acting on the plate. The gap is an indicator of the tightening force. It is found that t is inversely proportional to the gap, and proportional to the load, whereas h is proportional to the gap and inversely proportional to the load. Based on our FE analysis results, we propose the range 0.062 < t/h < 0.1 to ensure sufficient fastening (high clamping load, small gap) of the M8 blind rivet nut. The design guide for determining the t/h ratio proposed in this study can be used for general quantitative analysis of the size and the t/h ratio of blind rivet nuts.

Surgical Treatment of Prosthetic Valve Endocarditis after Reconstruction of the Intervalvular Fibrous Trigon -A case report- (판막간 섬유체 재건을 시행한 후 발생한 인공판막 심내막염의 수술적 치유 -1예 보고-)

  • Choi, Seon-Uoo;Kim, Wook-Sung;Min, Ho-Ki;Kang, Min-Woong;Lee, Young-Tak;Park, Pyo-Won
    • Journal of Chest Surgery
    • /
    • v.41 no.6
    • /
    • pp.755-758
    • /
    • 2008
  • We report here on a case of performing a redo-operation for a 65-years-old male patient who had prosthetic endocarditis after reconstruction of the fibrous skeleton due to infective endocarditis 8 years earlier. An aortic annular abscess with a 1cm sized subvalvular abscess and mobile mitral valve vegetation with destruction of the fibrous skeleton was shown on the preoperative echocardiography. An emergency operation was performed due to heart failure. Reconstruction of both the aortic and mitral annuli and the fibrous skeleton was done by using two separate bovine pericardial patches and then mechanical valves were implanted. The postoperative echocardiography shows no paravalvular leakage. The patient has been followed up with no symptoms.

A CASE REPORT OF COMPLICATIONS DURING MANDIBULAR TRANSVERSE SYMPHYSIS WIDENING (하악 이부 확장술 시 나타나는 합병증의 치험례)

  • Suh, Chung-Whan;Kang, Kyung-Hwa;Choi, Moon-Gi
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.5
    • /
    • pp.480-488
    • /
    • 2008
  • Orthodontists often treat cases which are difficult to treat with conventional orthodontics. In such cases, it could be treated with surgical procedures with the help of an oral surgeon. Especially, transverse deficiency of the mandible can be corrected by widening the transverse width of mandibular symphysis, using distraction osteogenesis. Transverse widening of mandibular sympysis is known as a safe treatment but still complications could occur during the treatment. We are reporting some complications of cases that mandibular symphysis transverse widening were applied. Some cases showed complications because of the inappropriate osteotomy line. Since straight vertical osteotomy line was inclined to the left, only the left bony segment was likely to expand. According to bio-mechanical considerations, it will be better to perform a step osteotomy, cutting the eccentric area of the alveolar crest and the centric area of the basal symphyseal area. Complications could also occur by the failure of the distraction device. The tooth borne distraction device was attached on the lingual side of the tooth with composite resin. During the distraction period, it was impossible to obtain appropriate distraction speed and rhythm because of frequent fall off of the distraction device. Therefore, distraction device should be attached firmly with orthodontic band or bone screw, etc. Tooth mobility increasement could also occur as a complication. 'Walking teeth phenomenon' was observed during the distraction period, showing severe teeth mobility and pain during mastication. These symptoms fade out during the consolidation period. Since the patient could feel insecure and uncomfortable, it should be notified to the patient before the procedure. Finally, alveolar crestal bone loss could occur. Alveolar crestal bone loss occurred because of lack of distraction device firmness and teeth trauma caused by lower lip biting habit. Therefore, adequate firmness of the distraction device and habit control will be needed.

Assessing Process and Method Improvement of Reliability Growth Test Data with Growth Rate Changing During Testing (신뢰성성장시험 중 발생한 신뢰성성장률 변화를 고려한 고장 평가과정 및 평가방법 개선에 대한 연구)

  • So, Young-Kug;Jeon, Young-Rok;Ryu, Byeong-Jin
    • Journal of Applied Reliability
    • /
    • v.14 no.2
    • /
    • pp.129-136
    • /
    • 2014
  • Reliability test is focusing to detect the unexpected reliability failure and solve them for the high quality of products. The test data should be used to assess and project the current level of interesting product reliability and so it is very important to have the accurately assessing methodology with test data. There are two type of trend for test data as constant and changing one during testing and this paper shows the difference in the assessing results of these two cases. There is less information how to define the existence of reliability growth rate changing and calculate the parameters of the reliability growth models to make an accurate assessment with such condition, so i established the process and mathematical model to calculate the parameters at such condition to make reliability growth curve with high Goodness of Fit. I validated the new method with the data made from Monte Carlo Simulation and case from Demko (1993). Even the assessed result with the new methodology may be different with the case by case because of very diversity in test condition and testing product quality, but the process and method founded in this research can be applied to any case using Duane and AMSAA model for their test data assessment. I also present the evaluation method to see the effectiveness with new one which is a conventional knowledge and not popular to use, so it is possible to compare the results with the newly presented and conventional method for better business decision.

Stress Analysis and Lead Pin Shape Design in PGA (Pin Grid Array) Package (PGA (Pin Grid Array) 패키지의 응력해석 및 Lead Pin 형상설계)

  • Cho, Seung-Hyun;Choi, Jin-Won
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.18 no.2
    • /
    • pp.29-33
    • /
    • 2011
  • Research about the geometry design of lead pin was carried based on the normal or shear stress of the interface between a lead pin and a PCB in terms of delamination failure. The taguchi method with four design factors of three levels and FEA(Finite element Analysis) are carried under $20^{\circ}$ bending and 50 ${\mu}m$ tension of lead pin. The contact width, d2, between head round and copper pad in PCB is the highest affection factor among design factors by analysis of contribution analysis. Equivalent von Mises stress of 18.7% reduction design is obtained by the parameter design of the taguchi method. Maximum normal stress occurred at contact position between solder outer surface and a Cu pad in PCB. Also, maximum shear stress happened at contact position between solder outer surface and SR layer of PCB. From these calculated results, delamination of the PGA package may be occurred from outer interface of solder to inner interface of solder.

Maxillary anterior implant restoration with appropriate anterior guidance using T-Scan in a patient with full fixed prostheses (전악 고정성 보철 수복 환자에서 T-Scan 분석을 이용해 전-측방유도를 부여한 상악 임플란트 보철 수복)

  • Nam, Rae-Kyeong;Pang, Eun-Kyoung;Cho, Young-Eun;Park, Eun-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.4
    • /
    • pp.419-426
    • /
    • 2017
  • In implant restorations, it is difficult for the patient to percept any symptoms. In addition, they are absent of shock absorbers, which can lead to mechanical failure if stress distribution is not considered. Since maxillary anterior multiple-implant restorations play a significant role in guiding the functional movement of the mandible by distributing lateral force, it is crucial to form appropriate occlusion. The use of the T-scan system is more advantageous in assessing 'dynamic occlusion', such as the change of occlusion over time, the amount of tooth contact during functional movement, and assessing the occlusion in the less-visible posterior teeth. The case is reported as it has satisfactory results in harmonious anterior guidance of a maxillary anterior multiple-implant restoration using T-scan analysis.

An Elderly Man with Fatal Respiratory Failure after Eating a Poisonous Mushroom Podostroma cornu-damae

  • Jang, Juah;Kim, Cheol-Hong;Yoo, Jun Jae;Kim, Mi Kang;Lee, Jae Eun;Lim, Ah Leum;Choi, Jeong-Hee;Hyun, In Gyu;Shim, Jung Weon;Shin, Ho-Seung;Han, Joungho;Seok, Soon Ja
    • Tuberculosis and Respiratory Diseases
    • /
    • v.75 no.6
    • /
    • pp.264-268
    • /
    • 2013
  • A 73-year-old, previously healthy man presented with nausea, vomiting, diarrhea, dry mouth and febrile sensation 3 hours after eating boiled wild mushrooms. After admission, he showed progressive severe respiratory distress, pancytopenia, azotemia, hypotension, hypoxemia and consolidation of the entire left lung on chest radiography. With a preliminary diagnosis of necrotizing pneumonia, he underwent left pneumonectomy in order to remove all necrotic lung tissue. Lung histology showed extensive hemorrhagic necrosis, massive inflammatory cell infiltration, prominent proliferation of young fibroblasts and the formation of an early-stage hyaline membrane along the alveolar wall. Despite aggressive treatment, including mechanical ventilation, continuous renal replacement therapy and administration of granulocyte colony stimulating factor and broad spectrum antibiotics, he died on hospitalization day 13. Subsequently, the mushroom was identified as Podostroma cornu-damae. This is the first case of a histological evidence of lung involvement by Podostroma cornu-damae poisoning in Korea.

Determination of Steel-Concrete Interface Parameters : Bonded and Unbonded Slip Tests (강-콘크리트 계면의 계면상수 결정 : 부착 및 비부착 슬립실험)

  • Lee, Ta;Joo, Young-Tae;Lee, Yong-Hak
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.6
    • /
    • pp.773-780
    • /
    • 2009
  • Experiments on steel-concrete interface are performed to investigate and determine the mechanical roles and properties of interface parameters. The intrinsic different nature of bonded and unbonded interfaces are addressed based on the experimental observations that were obtained from two types of tests considering bonded and unbonded interfaces. The unbonded tests are performed for the specimens that are in unbonded when the initially bonded specimens are tested first. Four cases of lateral confinements including pure slip, and low and medium levels of lateral pressure are taken into account to investigate the effects of lateral confinements on interface behavior. It is shown that the maximum shear strengths, the levels of residual strengths and the Mode II fracture energy release rates are linearly related to the confinement levels. Based on the experimental evidences obtained from this study, the values of interface parameters required in a steel-concrete interface constitutive model will be presented in the companion paper.

Flexural Crack for Fiber-Reinforced-Polymer Reinforced Concrete Beams (GFRP 보강근 콘크리트 보의 휨균열)

  • Park, Jong-Sup;Park, Young-Hwan;You, Young-Jun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.273-276
    • /
    • 2008
  • The use of FRP(Fiber Reinforced Polymer) bars to replace conventional steel bars in reinforcing concrete structures is currently encouraged by many structural engineers, especially for their noncorrosive properties. The partial inferiority of the bond and mechanical properties for FRP bars, however, leads to wider and deeper cracks compared with those of steel reinforced concrete structures. This paper presents experimental results of concrete beams reinforced with FRP bars tested under static loading conditions up to failure. The study focuses on the effects of the reinforcement ratio on the behavior of concrete beams at various stages during loading. The study also attempts to establish a theoretical basis for the development of simple and rational design procedures for concrete beams reinforced with FRP bars.

  • PDF

Omnipresence of Strain Localization in Soils (흙의 변형국지화 편재에 관한 연구)

  • 권태혁;조계춘
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.5
    • /
    • pp.199-210
    • /
    • 2003
  • The development of strain localization within shear zones is frequently observed during soil deformation. In fact, the phenomenon appears to be more often the norm rather than the exception. Conceptually, any soil condition that renders negative work increment is prone to localization. In this study, a broad range of soil and loading conditions are investigated to test this criterion, including: dilative soil subjected to drained shear (standard case), contractive soil sheared under undrained conditions, cavitation in dilative soil in undrained shear, inhomogeneous soils, particle alignment in contractive soils made of platy particles, soils that experience particle crushing, and the shear of low-moisture and/or lightly cemented loose soils. Unique specimens and test procedures are designed to separately test each of these soil conditions in the laboratory According to experimental test results, soil specimens with post-peak strain softening behavior are prone to progressive failure, localization of deformations, and shear banding. The state of stress, the soil density, inherent mechanical and geometrical properties of soil particles, low water content, and heterogeneity can contribute to triggering strain localization. Considering all possible cases of localization, the best method to obtain the critical state line in the laboratory is to use contractive homogeneous specimens subjected to drained shear.