• Title/Summary/Keyword: Mechanical Contactor

Search Result 18, Processing Time 0.019 seconds

Basic Study of Degradation Test for Magnetic Contactors and Reliability Centered Maintenance

  • Ryu, Haeng-Soo;Han, Gyu-Hwan;Yoon, Nam-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.4
    • /
    • pp.441-444
    • /
    • 2007
  • The mechanical endurance is the critical characteristic of Magnetic contactors (MCs), which are widely used in such industrial equipments as elevators, cranes, and factory control rooms in order to close and open the control circuit. Testing time, however, is so long in most cases that some method of reducing the testing period is required. Therefore, the degradation test by the detected vibration of MCs is developed to reduce the testing time in this work. The degradation test data are analyzed and the prediction model is provided. Also, the possibility of this technology for Reliability Centered Maintenance (RCM) will be shown. This will reduce the period of the product development and raise the reliability of the equipment in power distribution.

A Study on the Power Supply System for the Arc Lamp (아크램프를 위한 전원공급 시스템의 연구)

  • La, Jae Du
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.67 no.3
    • /
    • pp.125-130
    • /
    • 2018
  • Arc lamps are now widely utilized as illumination sources for a large number of investigations in wide-field fluorescence microscopy. Among many power converters for the lamp, the PSFB (Phase-Shift Full-Bridge) converter with the ZVS (Zero Voltage Switching) is the most widely used soft switched circuit in high-power applications. Also, in the most luminaries, the power factor has to be more and more important. Thus, the power factor correction(PFC) must be included in the power system. A new igniter module using the switching power device and the transformer is proposed instead of the conventional igniter using the mechanical contactor. The proposed converter with the high power factor and high efficiency is verified through the experimental works.

Design and Analysis of an Accelerated Life Test for Magnetic Contactors

  • Ryu, Haeng-Soo;Park, Sang-Yong;Han, Gyu-Hwan;Kwon, Young-Il;Yoon, Nam-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.2
    • /
    • pp.188-193
    • /
    • 2007
  • Magnetic contactors (MCs) are widely used in industrial equipment such as elevators, cranes and factory control rooms in order to close and open the control circuits. The reliability of MCs mainly depend on mechanical durability and international standards such as IEC 60947-4-1, which stipulates the testing method for MCs. Testing time, however, is so long in usual cases that a method of reducing testing time is required. Therefore, a temperature and voltage-accelerated life testing (ALT) method has been developed to reduce the testing time in this work. The accelerated life test data are analyzed and acceleration factors (AFs) are provided.

Contactless DC Circuit Breakers Using MOS-controlled Thyristors (전력용 사이리스터 MCT를 이용한 무접점 직류차단기)

  • Sim, D.Y.;Kim, C.D.;Nho, E.C.;Kim, I.D.;Kim, Y.H.;Jang, Y.S.
    • Journal of Power System Engineering
    • /
    • v.4 no.1
    • /
    • pp.45-50
    • /
    • 2000
  • Circuit breakers have traditionally employed mechanical methods to interrupt excessive currents. According to power semiconductor technology advances in power electronic device, some mechanical breakers are replaced with solid state equivalents. Advantages of the contactors using semiconductor devices include faster fault interrupting, fault current limiting, no arc to contain or extinguish and intelligent power control, and high reliability. This paper describes the design of a static $100{\pm}10%V$ and 0 to 50A DC self-protected contactor with 85A "magnetic tripping" and 100A interruption current at $2.2A/{\mu}s$ short circuit of load condition using a new power device the HARRIS MCT (600V-75A). The self-protection circuit of this system is designed by the classical ZnO varistor for energy absorption and turn-off snubber circuit ("C" or "RCD") of the MCT.

  • PDF

Effects of Grid Characteristics on High Speed Circuit Breaker for Railway Vehicle (철도 차량용 직류 고속도 차단기의 그리드 특성 해석)

  • Park, Ji-Won;Jung, Jooyoung;Choi, Jinnil
    • Journal of the Korean Society for Railway
    • /
    • v.19 no.2
    • /
    • pp.117-123
    • /
    • 2016
  • High speed circuit breakers(HSCB) interrupt the generated arc within the arc chute to turn off the electricity flowing through the main circuit to prevent ground faults. In order to explore the arc generated from the contactor operation, arc definition, establishment of arc interruption method, and analysis of magnetic driving force are required. In this paper, arc interruption capability has been estimated by exploring the difference in magnetic flux density of Lorenz forces using finite element analysis. In addition, since the number of grids and changes in the grid shape within the arc chute influence the formation of the inner magnetic field, its effects have been explored to enhance arc interruption capability. Assessment of interruption capability and analysis of grid shape, with rated operating current, are reported.

Study for an Artificial Visual Machine for the Blind (맹인용인공시각보조장치에 관한 연구)

  • 홍승홍;이균하
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.15 no.5
    • /
    • pp.19-24
    • /
    • 1978
  • In this paper, the functional propertied of vibrotactile sense of skin were studied by means of psycophysical experiments with respect to frequency and waveform of mechanical vibration, two-point threshold, contactor size of stimulators. Furthermore, leased on the experimental result, a small vibrotactile stimulator made of piezoelectrc ireed vibrator array was proposed for a aid blind to recognition of the Korean letters. A tactile output image is presented by an 8 row$\times$1 column array of samall vibrator reeds with 200 Hz rectangular wave, the array fitting on a fore-finger. Under the control of the NOVA mini-computer, the bimorph reeds array could represent any of one of the 24 characters of the Korean vowel and consonant at the 8 positions from left to right on the array. Without learning effect, the identification test of the Korean characters by the designed experimental system was carried out. The average rate of correct response was 90%.

  • PDF

Controlling the Morphology of Polyvinylidene-co-hexafluoropropylene (PVDF-co-HFP) Membranes Via Phase Inversion Method (상전이법을 이용한 P(VDF-co-HFP) 분리막 구조제어)

  • Song, Ye Jin;Kim, Jong Hoo;Kim, Ye Som;Kim, Sang Deuk;Cho, Young Hoon;Park, Ho Sik;Nam, Seung Eun;Park, You In;Son, Eun Ho;Kim, Jeong F.
    • Membrane Journal
    • /
    • v.28 no.3
    • /
    • pp.187-195
    • /
    • 2018
  • In this work, the morphology of polyvinylidene-co-hexafluoropropylene (PVDF-co-HFP) membranes were systemically investigated using phase inversion technique, to target membrane contactor applications. As the presence of macrovoids degrade the mechanical integrity of the membranes and jeopardize the long-term stability of membrane contactor processes (e.g. wetting), a wide range of dope compositions and casting conditions was studied to eliminate the undesired macrovoids. The type of solvent had significant effect on the membrane morphology, and the observed morphology were correlated to the physical properties of the solvent and solvent-polymer interactions. In addition, to fabricate macrovoid-free structure, the effects of different coagulation temperatures, inclusion of additives, and addition of nonsolvents were investigated. Due to the slow crystallization rate of P(VDF-co-HFP) polymer, it was found that obtaining porous membrane without macrovoids is difficult using only nonsolvent-induced phase separation method (NIPS). However, combined other phase inversion methods such as evaporation-induced phase separation (EIPS) and vapor-induced phase separation (VIPS), the desired membrane morphology can be obtained without any macrovoids.

Safety Schematic Diagram and Sequence of Heater in FPD Wet Equipment (FPD 장비 습식공정에서의 안전한 히터 공급 계통도 및 제어 회로)

  • Yoo, Heung-Ryol;Son, Yung-Deug
    • Journal of IKEEE
    • /
    • v.23 no.1
    • /
    • pp.107-111
    • /
    • 2019
  • In FPD WET equipment, heaters are used a lot. There are many electric accidents caused by short circuit and overheating due to the use of heater, so it is necessary to have a safe electric system and interlock. Therefore, in this paper, we propose an electrical schematic and interlock for FPD WET equipment. In this paper, a hardware interlock such as a level sensor, an overheat protector, and an SSR heater sink is inserted, and the electric system is composed of ELB - MC - SSR - EOCR - heater. When the interlock occurs, the magnetic contactor (MC) is turned off and the power of the heater is cut off.EOCR, an electric overcurrent protection device, has an interlock to shut down the MC when there is an abnormality in the heater while checking the overcurrent, undercurrent and disconnection. These circuit configurations and interlocks are likely to be useful not only for WET equipment but also for any equipment in which the heater is placed.