• Title/Summary/Keyword: Mechanical Alignment

Search Result 345, Processing Time 0.031 seconds

Investigation on Liquid Crystal Alignment Effects of SiNx Thin Film Irradiated by Ion Beam (이온 빔 조사된 SiNx 박막의 액정 배향 효과에 관한 연구)

  • Lee, Sang-Keuk;Kim, Young-Hwan;Kim, Byoung-Yong;Han, Jin-Woo;Kang, Dong-Hun;Kim, Jong-Hwan;Seo, Dae-Shik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.398-398
    • /
    • 2007
  • Most recently, the Liquid Crystal (LC) aligning capabilities achieved by ion beam exposure on the diamond-like carbon (DLC) thin film layer have been successfully studied. The DLC thin films have a high mechanical hardness, a high electrical resistance, optical transparency and chemical inertness. Nitrogen doped Diamond Like Carbon (NDLC) thin films exhibit properties similar to those of the DLC films and better thermal stability than the DLC films because C:N bonding in the NDLC film is stronger against thermal stress than C:H bonding in the DLC thin films. Moreover, our research group has already studied ion beam alignment method using the NDLC thin films. The nematic liquid crystal (NLC) alignment effects treated on the SiNx thin film layers using ion beam irradiation for three kinds of N rations was successfully studied for the first time. The SiNx thin film was deposited by plasma-enhanced chemical vapor deposition (PECVD) and used three kinds of N rations. In order to characterize the films, the atomic force microscopy (AFM) image was observed. The good LC aligning capabilities treated on the SiNx thin film with ion beam exposure for all N rations can be achieved. The low pretilt angles for a NLC treated on the SiNx thin film with ion beam irradiation were measure.

  • PDF

Influence of Plate Design on the Accuracy of Tibial Alignment after Center of Rotation of Angulation-Based Leveling Osteotomy in Toy-Breed Dogs

  • Han, Jae-Hong;Lee, Hae-Beom;Jeong, Jae-Min;Jeon, Young-Jin;Roh, Yoon-Ho
    • Journal of Veterinary Clinics
    • /
    • v.39 no.3
    • /
    • pp.100-106
    • /
    • 2022
  • The center of rotation of angulation-based leveling osteotomy (CBLO) has been introduced for the stabilization of cranial cruciate ligament rupture (CCLR) in small-breed dogs. This technique can be applied to the tibia without damaging its tuberosity. Although different designs of CBLO plates are available, tibial plateau leveling osteotomy (TPLO) plates have been still used for stabilization during CBLO. To the best of our knowledge, no studies have reported the effects of TPLO plates on the postoperative limb alignment after CBLO. Therefore, the present study (January 2020 to February 2021) aimed to compare the postoperative outcomes (postoperative tibial plateau angle [TPA] and tibial alignment) in patients receiving CBLO and TPLO plates during CBLO. Paired stifle joints (n = 16) were obtained from eight toy-breed cadaver dogs (mean weight, 4.4 kg) that underwent CBLO. The joints were randomly assigned to receive the CBLO (CBLO group) or TPLO plates (TPLO group). Pre-and postoperative radiographs were obtained, and the dissected tibiae were evaluated. The following postoperative parameters were compared to evaluate the surgical outcome: TPA, osteotomy location, mechanical medial proximal tibia angle, inter-segment gap, and tibial plateau translation. No significant differences were found in the postoperative alignment between the two groups. Therefore, TPLO plates may be considered as a viable alternative in toy-breed dogs undergoing CBLO.

Effect of Granule Characteristics of Mixed Powder on Mechanical Properties of Hot-Pressed SiC-Whisker/Alumina Composites (혼합분말의 과립특성이 가압소결 탄화규소 휘스커/알루미나 복합재료의 기계적 물성에 미치는 영향)

  • 이해원;송휴섭
    • Journal of the Korean Ceramic Society
    • /
    • v.31 no.12
    • /
    • pp.1513-1520
    • /
    • 1994
  • Mechanical properties of hot-pressed SiC whisker/Al2O3 composites were strongly dependent on the granular characteristics of mixed powder, which were controlled by co-dispersion condition, the existence of steric barrier on whisker surface, and granulating method, etc. Heat-treatment of SiC whiskers at $700^{\circ}C$ for 1 hr in air was very effective both for achieving dispersion stability of whiskers with PVA adsorption and for obtaining excellent mechanical properties of resulting composites. It is believed from the fractography of composites prepared with various whisker dispersion conditions that the most common fracture origin of Al2O3 agglomerate could be attributed to whisker clusters arising due to flocculation. Further improvement of mechanical properties of composites were achieved by hot pressing green tapes prepared by Doctor-blade process, which promoted two-dimensional random alignment of whiskers.

  • PDF

A Novel Tensile Specimen and Test Machine for Mechanical Properties of MEMS Materials (MEMS 소재의 기계적 특성 평가를 위한 인장형 시편 및 시험기 제작)

  • Park, Jun-Hyub;Kim, Chung-Youb;Lee, Chang-Seun;Choa, Sung-Hoon;Song, Ji-Ho
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.258-263
    • /
    • 2004
  • Mechanical property evaluation of micrometer-sized structures is necessary to help design reliable microelectromechanical systems(MEMS) devices. Most material properties are known to exhibit dependence on specimen size and such properties of microscale structures are not well characterized. This paper describes techniques developed for tensile testing of materials used in MEMS. Epi-polycrystalline silicon is currently the most widely used material, and its tensile strength has been measured as 1.52GPa. We have developed an uniaxial testing machine for testing microscale specimen using electro-magnetic actuator. The field magnet and the moving coil taken from an audio-speaker were utilized as the components of the actuator. Structure of specimen was designed and manufactured for easy handling and alignment. In addition to the static tensile tests, new techniques and procedures for measuring strength are described.

  • PDF

Experimental and microstructural evaluation on mechanical properties of sisal fibre reinforced bio-composites

  • Kumar, B. Ravi;Hariharan, S.S.
    • Steel and Composite Structures
    • /
    • v.33 no.2
    • /
    • pp.299-306
    • /
    • 2019
  • The natural fibre composites are termed as bio-composites. They have shown a promising replacement to the current carbon/glass fibre reinforced composites as environmental friendly materials in specific applications. Natural fibre reinforced composites are potential materials for various engineering applications in automobile, railways, building and Aerospace industry. The natural fibre selected to fabricate the composite material is plant-based fibre e.g., sisal fibre. Sisal fibre is a suitable reinforcement for use in composites on account of its low density, high specific strength, and high hardness. Epoxy is a thermosetting polymer which is used as a resin in natural fibre reinforced composites. Hand lay-up technique was used to fabricate the composites by reinforcing sisal fibres into the epoxy matrix. Composites were prepared with the unidirectional alignment of sisal fibres. Test specimens with different fibre orientations were prepared. The fabricated composites were tested for mechanical properties. Impact test, tensile test, flexural test, hardness test, compression test, and thermal test of composites had been conducted to assess its suitability in industrial applications. Scanning electron microscopy (SEM) test revealed the microstructural information of the fractured surface of composites.

3-Dimensional Gait analysis and the relationship between lower limb alignment and knee adduction moment in elderly healthy women (3차원적 동작 분석기를 이용한 건강한 여자 노인의 하지 정렬 상태와 슬관절 내전 모멘트의 상관 관계에 관한 연구)

  • Cho, You-Mi;Lee, Wan-Hee
    • Journal of Korean Physical Therapy Science
    • /
    • v.10 no.1
    • /
    • pp.90-101
    • /
    • 2003
  • Gait analysis can provide a better understanding of how the alignment of the lower limb and foot can contribute to force observed at the knee. Anatomic and mechanical factors that affect loading in the knee pint can contribute to pathologic change seen at the knee in degenerative pint disease and should be considered in treatment plan. The purpose of this study is to present the gait analysis data and to determine whether there is any relationships between alignment of the lower limb, foot progression angle and knee pint moments in elderly healthy women with 3-dimensional motion analyzer. The results were as follows; 1. Cadence showed 114.8 steps/min, gait speed showed 1.05 m/s, time per a stride showed 1.06 sec, time per a step showed 0.53 sec, single-supporting phase was 0.41 sec, double-supporting phase was 0.24 sec, stride length was 1.04 m, Step length was 0.56 m. 2. According to the parameters of kinematics, the maximal knee flexion angle through swing phase showed left $46.82^{\circ}$, right $40.19^{\circ}$ and the maximal knee extension angle showed left $-1.32^{\circ}$, right $2.01^{\circ}$. knee varus showed left $26.90^{\circ}$, right $30.93^{\circ}$. 3. Moment, one of kinetic parameters of knee pint the maximal flexion moment showed left 0.363. Nm/kg, right 0.464 Nm/kg and maximal extension moment showed left 0.389 Nm/kg, right 0.463 Nm/kg. The maximal. adduction moment showed left 0.332 Nm/kg, right 0.379 Nm/kg and the maximal internal rotatory moment showed left 0.13 Nm/kg, right 0.140 Nm/kg. 4. On sagittal plane, the maximal power of knee joint showed left 0.571 J/kg, right 0.629 J/kg. On coronal plane, the maximal power of knee joint showed left 0.11 J/kg, right 0.12 J/kg. On transverse plane, the maximal power of knee joint showed left 0.058 J/kg, right 0.072 J/kg. 5. The subject who had varus alignment of the lower extremity had statistically higher in knee adduction moment in mid stance phase. 6. The subject who had large foot progression angle had statistically lower in knee adduction moment in late stance phase. A relationship was observed between the alignment of the lower extremity and the adduction moment of the knee joint during stance phase. Hence, we need some research to figure, out the change of adduction moment according to the sort of knee joint osteoarthritis and the normal geriatrics as well. And we also require more effective, specific therapeutic program by making use of those background of researches.

  • PDF

Investigation on EO Characteristics of SiNx Thin Film Irradiated by Ion-beam (이온 빔 조사된 SiNx 박막의 전기 광학적 특성에 관한 연구)

  • Lee, Sang-Keuk;Oh, Byeong-Yun;Kim, Byoung-Yong;Han, Jin-Woo;Kim, Young-Hwan;Ok, Chul-Ho;Kim, Jong-Hwan;Han, Jeong-Min;Seo, Dae-Shik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.429-429
    • /
    • 2007
  • For various applications of liquid crystal displays (LCDs), the uniform alignment of liquid crystal (LC) molecules on treated surfaces is significantly important. Generally, a rubbing method has been widely used to align the LC molecules on polyimide (PI) surfaces. Rubbed PI surfaces have suitable characteristics, such as uniform alignment. However, the rubbing method has some drawbacks, such as the generation of electrostatic charges and the creation of contaminating particles. Thus, we strongly recommend a non contact alignment technique for future generations of large high-resolution LCDs. Most recently, the LC aligning capabilities achieved by ultraviolet and ion-beam exposures which are non contact methods, on diamond-like carbon (DLC) inorganic thin film layers have been successfully studied because DLC thin films have a high mechanical hardness, a high electrical resistivity, optical transparency, and chemical inertness. In addition, nitrogen-doped DLC (NDLC) thin films exhibit properties similar to those of the DLC thin films and a higher thermal stability than the DLC thin films because C:N bonding in the NDLC thin filmsis stronger against thermal stress than C:H bonding in the DLC thin films. Our research group has already studied the NDLC thin films by an ion-beam alignment method. The $SiN_x$ thin films deposited by plasma-enhanced chemical vapor deposition are widely used as an insulation layer for a thin film transistor, which has characteristics similar to those of DLC inorganic thin films. Therefore, in this paper, we report on LC alignment effects and pretilt angle generation on a $SiN_x$, thin film treated by ion-beam irradiation for various N ratios

  • PDF

Optical Design for Satellite Camera with Online Optical Compensation Movements (온라인 광학보정장치를 적용한 위성카메라의 광학설계)

  • Jo, Jeong-Bin;Hwang, Jai-Hyuk;Bae, Jae-Sung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.3
    • /
    • pp.265-271
    • /
    • 2015
  • In this study, optical design for small satellite camera equipped with online optical compensation movements has been conducted. Satellite camera equipped with compensation movements at M2 mirror and focal plane can guarantee the MTF performance through the focal plane image stabilization and the on-orbit optical alignment. The designed optical system is schmidt-cassegrain type that has M1 mirror of a diameter 200mm, GSD 3.8m at an altitude of 700km, and 50 % MTF performance. The performance of the designed optical system has been analyzed through the method of ray aberration curve, spot diagram, and MTF. It has been found by the optical performance analysis that the designed optical system satisfies the optical requirements of satellite camera equipped with online optical compensation movements.

Effects of Fiber Alignment Direction and Stacking Sequence of Laminates on Fracture Behavior of Biomimetic Composites under Pressure Loading (압력하중 하에서 섬유배열방향과 적층판의 적층순서에 따른 생체모방 복합재의 파괴 거동에 관한 연구)

  • Myungsoo Kim
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.1
    • /
    • pp.201-209
    • /
    • 2023
  • Recently, fiber-reinforced composites have been widely used in various industrials fields. In this study, the mechanical behavior, especially fracture behavior, of biomimetic fiber-reinforced composites subjected to pressure loading was analyzed using finite element analysis (FEA). The fiber alignments in the biomimetic composites formed a helicoidal structure, wherein a stacking sequence involved a gradual rotation of each ply in the multi-layered laminated composites. For comparison, cross-ply composite samples with fibers arranged at 0° and 90° were prepared and analyzed. In addition, the mechanical behavior was analyzed based on combinations of the stacking sequence of carbon-fiber composites and glass-fiber composites. The FEA results showed that, when compared with the cross-ply samples, the mechanical properties of the biomimetic composites were considerably improved under pressure loading, which was applied to one side of the composites. Thus, the biomimetic helicoidal structure significantly improved the mechanical properties of the composites. Placing materials having high elasticity and strength in the outermost layers (the layer of the side on which pressure was applied and the opposite side layer) of the composites also significantly contributed to improving the mechanical properties of the composites.

Musculoskeletal Kinematics During Voluntary Head Tracking Movements in Primate

  • Park, Hyeonki;Emily Keshner;Barry W. Peterson
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.32-39
    • /
    • 2003
  • In this study we examined connections between vertebral motion and patterns of muscle activation during voluntary head tracking movements. A Rhesus (Maraca mulatta) monkey was trained to produce sinusoidal tracking movements of the head in the sagittal plane while seated. Radio-opaque markers were placed in the cervical vertebrae, and intramuscular patch electrodes were implanted to record from eight neck muscles. Videofluoroscopic images of cervical vertebral motion, and EMG (electromyographic) responses were simultaneously re-corded. Experimental results demonstrated that head and vertebrae moved synchronously and that motion occurred primarily at skull-C$_1$, C$\_$6/-C$\_$7/ and Csub 7/-C$_1$. Our findings illustrate that although the biomechanical constraints of each species may limit the number of solutions available, it is the task requirements that appear to govern CNS (central nervous system) selection of movement behaviors.