• Title/Summary/Keyword: Measuring technology level

Search Result 506, Processing Time 0.032 seconds

River level/velocimetry measuring system using the ultrasonic sensor (초음파센서를 이용한 하천 수위/유속 측정 시스템)

  • Park, Hee-Suk;Park, Chan-Won
    • Journal of Industrial Technology
    • /
    • v.26 no.B
    • /
    • pp.249-255
    • /
    • 2006
  • In this paper, we study the river level/velocimetry measuring system using the ultrasonic sensor to acquire the more precise data from the river circumstance in rainy season. We design the two ultrasonic sensor system to calculate the water level and surface current speed of the river using the dedicated hardware and software. We investigate the validity and effectiveness of the proposed system which applied to the real river environment monitoring system that will be extended to the GIS.

  • PDF

Case Study on Measuring Technology Level Applying Growth Curve Model: Three Core Areas of Fishery Science and Technology (성장곡선 모형 적용을 통한 기술수준평가 사례 연구 : 특정 수산과학기술 분야를 중심으로)

  • Kim, Wan-Min;Park, Ju-Chan;Bark, Pyeng-Mu
    • The Journal of Fisheries Business Administration
    • /
    • v.46 no.3
    • /
    • pp.103-118
    • /
    • 2015
  • The purpose of this paper is to discuss possibilities of applying growth curve models, such as Logistic, Log-Logistic, Log-Normal, Gompertz and Weibull, to three specific technology areas of Fishery Science and Technology in the process of measuring their technology level between Korea and countries with the state-of-the art level. Technology areas of hazard control of organism, environment restoration, and fish cluster detect were selected for this study. Expert panel survey was conducted to construct relevant panel data for years of 2013, 2016, and a future time of approaching the theoretical maximum technology level. The size of data was 70, 70 and 40 respectively. First finding is that estimation of shape and location parameters of each model was statistically significant, and lack-of-fit test using estimated parameters was statistically rejected for each model, meaning all models were good enough to apply for measuring technology levels. Second, three models other than Pearl and Gompertz seemed very appropriate to apply despite the fact that previous case studies have used only Gompertz and Pearl. This study suggests that Weibull model would be a very valid candidate for the purpose. Third, fish cluster detect technology level is relatively higher for both Korea and a country with the state-of-the-art among three areas as of 2013. However, all three areas seem to be approaching their limits(highest technology level point) until 2020 for countries with the state-of-the-art. This implies that Korea might have to speed up her research activities in order to catch up them prior to 2020. Final suggestion is that future study may better apply various and more appropriate models respectively considering each technology characteristics and other factors.

Study on Priority of Measuring Instrument for Rockfall and Landslide Prevention (낙석.산사태 방지를 위한 계측기기의 우선순위 선정 연구)

  • Kim, Yong-Soo;Jung, Soo-Jung
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.1304-1312
    • /
    • 2008
  • In this study, the analysis to the preference level on slope measuring instrument of weight values on effect factors find out the reasonable monitoring on slope was performed, in which used AHP(Analytic Hierarchy Process) techniques. The results on professional group, such as the industry, academic, institute and government, analyzed that the very important effect factors, which were indicator of various collapse type, convenience of instrument management, The evaluation of preference level on the slope measuring instrument analyzed the invar wire extensometer which was high level at convenience of install, economical efficiency of install and convenience of instrument management.

  • PDF

A Study on the Science and Technology Level of Strategic Items in Korea (우리나라 10대 전략제품의 과학기술수준 조사연구)

  • 한성구;정근하;이상엽
    • Proceedings of the Technology Innovation Conference
    • /
    • 2000.06a
    • /
    • pp.153-173
    • /
    • 2000
  • This study is focused on measuring levels of science and technology aspect of ten strategic items in korea to serve as a guidance for the government R&D policy-making, and provide appropriate information for promoting the national R&D programs. The survey of the precise technology level for study applies functional and technical parameters. Functional parameters are used for measuring technology level of the specification and performance of emerging items such as 256M DRAM, TFT-LCD ect. in the present and / or near future; technical parameters, the element / core technologies on emerging items. The study suggests that the result of the survey should be applied for strategic technology planning to narrow the technology gap and draw the criteria for resource allocation in national R&D programs.

  • PDF

A Low Power Wireless Communication-based Air Pollutants Measuring System (저전력 무선통신 기반 대기오염 측정시스템)

  • Kang, Jeong Gee;Lee, Bong Hwan
    • Journal of Information Technology Applications and Management
    • /
    • v.28 no.6
    • /
    • pp.87-95
    • /
    • 2021
  • Recently interest for air pollution is gradually increasing. However, according to the environmental assessment of air quality, the level of air pollution in the nation is quite serious, and air pollutants measuring facilities are also not enough. In this paper, a secure air pollutants sensor system based low power wireless communication is designed and implemented. The proposed system is composed of three parts: air pollutants measuring sensors module, LoRa-based data transmission module, and monitoring module. In the air pollutants measuring module, the MSP430 board with six big air pollutants measuring sensors are used. The air pollutants sensing data is transmitted to the control server in the monitoring system using LoRa transmission module. The received sensing data is stored in the database of the monitoring system, and visualized in real-time on the map of the sensor locations. The implemented air pollutant sensor system can be used for measuring the level of air quality conveniently in our daily lives.

A Study on the Development of ppb Level Dissolved Oxygen Measuring Technology using Clark Cell (Clark Cell을 이용한 ppb Level 용존산소 측정기술 개발에 관한 연구)

  • 정경열;이후락;동은석;이수태;류길수
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2001.05a
    • /
    • pp.197-201
    • /
    • 2001
  • Measuring of the dissolved oxygen is widely used for the environmental control of natural waters, sewage waste treatment, medical and biochemical studies, soil husbandry, food and drug process control, and prevention of corrosion in boilers. Especially, a power plants need special management for preventing accidents from corrosion, therefore, it is essential to measure the concentration of dissolved oxygen in real-time. In this paper we present a method of measuring dissolved oxygen very accurately up to ppb units. This method, called polarographic method, is based on the measures of the electric current generated by the oxidation process in cathode and de-oxidation process in anode, assuming that the amount of the current is proportional to the density of dissolved oxygen.

  • PDF

A Study on the Development of a pub level Silica Measuring Technology by the Split-beam Type System (스플리트빔 형태의 고정도 단위 실리카 측정기술 개발에 관한 연구)

  • 정경열;류길수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.26 no.3
    • /
    • pp.382-388
    • /
    • 2002
  • Dissolved silica is one of fatal components at a boiler facility Therefore, a dissolved silica measurement system should be equipped for managing efficiently the boiler facility. Most of silica measurement systems are composed of a sensor module of single-beam type structure, and silica density is measured with a infrared spectrometry using the Lambert-beer method. However, such a system occurs measuring error of large range and inconsistency of a light source, because of measuring a standard sample and a measuring sample alternatively. This paper introduces a method that the sensor module has a split-beam type structure and a tungsten lamp. The proposed system can measure silica density quickly and precisely more than those composing of a single-beam type structure, because of measuring and comparing with two samples at a same time. And examination results are shown to compare efficiencies of the system and existing commercial products, and for an ammonia influence.

Construction and Validation of a Cognitive Presence Scale for Measuring Online Learners' Engagement

  • KANG, Myunghee;CHOI, Hyungshin
    • Educational Technology International
    • /
    • v.10 no.1
    • /
    • pp.41-57
    • /
    • 2009
  • Cognitive presence, a sense of "being there" cognitively, has recently been considered as an important indicator for students' engagement in e-learning. There is, however, no widely accepted scale to measure the level of cognitive presence since most studies have put their effort to set and clarify the conceptual framework with qualitative methodology. This study reviewed existing theories on cognitive presence and related fields extensively and developed a new self-report scale for measuring the conceived level of cognitive presence. The reliability and validity of the scale was tested against 723 undergraduate students in two consecutive studies, 418 in the preliminary and 305 in the follow-up study. Three major constructs to measure the perceived level of cognitive presence were: 1) clear understanding, 2) knowledge construction, and 3) learning management. This paper reports the final results of the two independent studies.

Development of the Qualitative Industrial Technological Level Indicator to Evaluate the Technology Competitiveness (기술 경쟁력 평가를 위한 정성적 산업기술 수준지표 개발)

  • 이재하;박상민
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.20 no.42
    • /
    • pp.67-72
    • /
    • 1997
  • How to measure technological level has concerned research analysists for a long time. Many methods exist, and they all have their advantages and disadvantages according to how they are used. The purpose of this study is to develop qualitative indicator to measure industrial technological level, in particular manufacturing capacity. In this indicator, the two basis of technology classification and the concept of the technology competitiveness were introduced. First, the types of technology are classified as three classes : material technology, processing technology and product technology. Second, the characteristics of technology are divided into the three categories : core technology, peripheral technology and sprouting technology On this basis, the qualitative technological level was made in terms of the competitiveness of it's manufacturing capacity. This study should be a practical approach for application of measuring of technological level.

  • PDF

A Stuty on Development of Spitted beam Type On-line Silica Analyzing sysyem (Splitted Beam Type On-line 실리카 분석기 개발에 관한 연구)

  • Jeong, Gyeong-Yeol;Lee, Hu-Rak
    • 연구논문집
    • /
    • s.30
    • /
    • pp.43-56
    • /
    • 2000
  • N-IR spectroscopy technology is very useful. And, the technology has wide application range. In the range, we know that single beam type silica analyzer has some handicap. So we were studied Splitted beam type silica analyzer. This dissertation have been discuss about system structure, system fundamentals and performance test. At the test, we were study in the spectral interference of NH3. We know that existing system had some problem. It is structural frailties of single beam type. Therefore we were study for Splitted beam type structure. And we obtain a good result. We have $\pm$5% accuracy and 0.5 ppb level measuring range. But, we have a question. It is ppt level measuring technology by the laser beam spectroscopy.