• Title/Summary/Keyword: Measuring sensor

Search Result 1,960, Processing Time 0.037 seconds

Measurement of transmitted vibration to stapes and tympanic membrane by DFMT's vibration in implantable middle ear hearing devices (중이 이식형 보청기에서 DFMT의 진동에 의한 등골 및 고막 방향으로 전달되는 진동력 측정)

  • Lee, Myoung-Won;Seong, Ki-Woong;Lim, Hyung-Gyu;Kim, Min-Woo;Jung, Eui-Sung;Lee, Jang-Woo;Kim, Dong-Wook;Lee, Jyung-Hyun;Lee, Sang-Heun;Lee, Kyu-Yup;Cho, Jin-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.286-293
    • /
    • 2009
  • The implantable middle ear hearing devices(IMEHDs) have been developed to overcome the conventional hearing aid's problem(ringing effect caused by the acoustic feedback, cosmetic problem, etc.). In the IMEHDs, the vibrating transducer is a key component because its vibration enables to hear for hearing impaired people. The vibrating transducer is implanted on ossicular chain by surgical operation. The coupling status between implanted transducer and ossicular chain has an effect on delivering vibrating force from transducer to stapes. Noninvasive method is required to investigate the output characteristics of IMEHDs after implementation. Recently, emitted sound pressure measuring method of tympanic membrane is proposed to investigate the output characteristics of IMEHDs. However, the relationship between displacement of stapes and sound pressure by tympanic membrane was not cleared. In this paper, displacement of stapes and sound pressure by tympanic membrane were measured using the differential floating mass transducer(DFMT) that implanted on the ossicular chain of the human temporal bone and physical ear model. Through the experiments results, the relationship between displacement of stapes and sound pressure by tympanic membrane was investigated.

Research of Hydraulic Breaker with Rock Properties Predictability Using the ICT (ICT 융합기술을 활용한 암반특성 예측기능을 가진 유압 브레이커 개발에 관한 연구)

  • Yoon, Bok Joong;Lee, Kil Soo;Lim, Hoon;Lee, Ho Yeon;Lee, Myung Gyu;Kwon, Hyuk Jin;Kim, Kab Tae;Joo, Jin Moo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.7
    • /
    • pp.683-689
    • /
    • 2017
  • We have carried out the development for hydraulic breaker which can be operated by optimal mode with ICT convergence technology. This developed system can predict the rock properties. Moreover, this system can maximize the energy efficient with intelligent control of hydraulic system. In order to provide the optimal impact force, this system can measure the descending depth of piston with the proximity sensor and discriminate the rock properties with the measuring data and control the piston stroke using solenoid valve eventually. In addition, we have developed the controller, display module and operating device for cascade (multi-level impact) system and applied the module which can communicate each system by wireless communications. In conclusion, the control system which can control the multi-level impact in accordance with strength of rocks has been developed and approved by several field tests.

Test Method Using VOC Analyzer to Measure VOC Emission of Paints for Wood-based Panel (VOC Analyzer를 이용한 목재용 도료의 휘발성유기화합물의 간이측정)

  • Eom, Young Geun;Kim, Ki-Wook;An, Jae-Yun;Kim, Hyun-Joong;Moon, Suck-Joong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.35 no.6
    • /
    • pp.65-72
    • /
    • 2007
  • The VOC (volatile organic compound) analyzer is devised to measure the four main aromatic hydrocarbon gases: toluene, ethylbenzene, xylene and styfene. It is not affected by ambient temperature and humidity. In addition, standby and measuring time of VOC Analyzer is a short as below 30 min and 8 min, respectively. Since the semiconductor gas sensor is supersensitive to gas components, it is not necessary to use a conventional gas concentrator or other complicated equipment. In this study, VOC emission behavior from 4 types paints (lacquer, urethane vanish, water-base paint, enamel paint) for wood-based panel was investigated using VOC Analyzer. After a specimen was spreaded on aluminum foil ($6.32{\times}6.32cm$) in $3{\ell}$ polyester bag, after 24 hours we could measure maximum VOC emission level that is a stabilized VOC value. Xylene of VOCs was high emitted from lacquer, urethane vanish and water-based paint, and TVOC (Toluene + Ethylbenzene + Xylene + Styrene) of lacquer was the highest emission concentration than another.

Spatial Variability Analysis of Paddy Rice Yield in Field (필지내 벼 수량의 공간변이 해석)

  • 이충근;우메다미키오;정인규;성제훈;김상철;박우풍;이용범
    • Journal of Biosystems Engineering
    • /
    • v.29 no.3
    • /
    • pp.267-274
    • /
    • 2004
  • Using geo-statistical method, yield data of different fields were analyzed to examine their field variability according to examining year, analysis method. Semivariogram and Kriged maps of geo-statistical analysis were used to examine their spatial dependence within a filed. The results obtained were as follows. 1) Descriptive statistical results of the yield showed that the yield and the difference of yield ranged from 100 to 946kg/10a and from 272 to 653kg/10a, respectively within a field. The coefficient of variation also ranged from 5.9 to 22.4 %. 2) More than 90% of yield data were placed between 350 to 850kg/10a. e results indicated that the gram mass flow sensor should have the measuring range from 0.34 to 0.82kg/s considering the yields when 4 rows head-feeding combine with 0.8 m/s of working speed was utilized. 3) A high spatial dependence was found within paddy field. The Q values ranged from 0.20 to 0.97, and the range of spatial dependence was from 6.9 to 53.3m. From this result, the rational sampling interval for yield investigation was estimated 6.9m. 4) Yields within a field between observation years showed considerable variability even if the field was evenly cultivated and managed. To apply precision agriculture in a paddy field, the field test should be continued to build a solid data-base including meteorological data, blight damage and insect damage.

Analysis of the Characteristics of Polyurethane Synthesis Using Quartz Crystal Analyzer (수정진동자 분석기를 이용한 폴리우레탄 합성반응의 특성분석)

  • Cho, Hong-Sik;Park, Jin-Young;Han, Dae-Sang;Park, Ji-Sun;Lee, Hang-Ja;Kim, Kwang;Chang, Sang-Mok
    • Journal of Sensor Science and Technology
    • /
    • v.9 no.1
    • /
    • pp.28-35
    • /
    • 2000
  • In this study, we investigated the characteristics of polyurethane synthesis by simultaneously measuring resonant frequency and resonant resistance with a quartz crystal analyzer. The rapid decrease of resonant frequency was appeared because automatic catalytic reaction was caused by the polyurethane formed in initial stage of polyurethane synthesis. In prepolymer(PP) synthesis, the resonant frequency was slowly stabilized after a rapid decrease at a certain point of time. But in segmented polyurethane synthesis in which chain-extender was involved, the resonant frequency increased again after a rapid decrease at a certain point of time. It was considered that this tendency took place because the chain-extender, 1,4-butandiol, caused a soft segment to change to a hard segment. The resonant resistance was used in the analysis of mechanism. From the results, the characteristics of polyurethane synthesis could be analyzed on-line using a quartz crystal analyzer, and the synthesis mechanism could also be interpreted.

  • PDF

Fabrication and Its Characteristics of Ion Energy Spectrometer for Diagnostics of Plasma (플라즈마 진단을 위한 이온에너지 분석장치의 제작 및 특성 조사)

  • Kim, Kye-Ryung;Kim, Wan;Lee, Yong-Hyun;Kang, Hee-Dong
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.163-170
    • /
    • 1998
  • An ion energy spectrometer which has the $45^{\circ}$ parallel electrostatic deflection plate was designed and constructed for measuring ion temperature in high temperature plasma. The energy calibration and the energy resolution were studied in detail for a hydrogen ion at the $0.24{\sim}1.92\;keV$ energy using electrostatic accelerator with a duoplasmatron ion source. The voltage of the deflection plate was linearly increased for the decreased ion detector position at the constant ion energy and decreased for the increased ion energy at the fixed ion detector position. The inclination of the deflection plate voltage to the ion energy was between 0.92 and 1.61, and linearly decreased for the increased the ion detector position. The measured energy resolution, which is $4.2%\;{\sim}\;11.6%$ in this experiment region, was improved for the increased ion dector position and ion energy. The relative efficiency was increased for the decreased the ion detector position. The ion energy spectrum of the DC plasma in the multi-purpose plasma generator was measured using this equipment. The ion temperature was 203-205 eV at the discharge voltage 320 V, discharge current 1.7 A.

  • PDF

A Study on the Telemetry system for the Inhabitant Environments and Distribution of Fish-I - Sea Temperature , Salinity and Distribution of Fish - (어류의 서식환경과 분포생태의 원격계측에 관한 연구-I - 수온, 염분과 어류의 분포생태 -)

  • Sin, Hyeong-Il;An, Yeong-Hwa;Sin, Hyeon-Ok
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.33 no.4
    • /
    • pp.321-333
    • /
    • 1997
  • This paper describe on the transmitting/receiving functions and the monitoring effects for the telemetry system which is designed to monitor the environmental condition of a culturing fishery ground inside a bay. The telemetry experiments were carried out by the telemetry system which constructed with the sea water temperature/salinity measuring sensor and telesounder at culturing fishery ground located in the coast of Sangyang-Myon, Kyongsangnam-Do province from October, 1995 to May, 1996. The results of this experiment showed that the developed telemetry system could be used for monitoring the sea water temperature/salinity and the distribution of fish in culturing fishery ground.

  • PDF

Performance Evaluation of Balance Ability Equipment Using VR (VR을 이용한 균형능력 측정장비의 성능평가)

  • Yoon, Sangcheol;An, Howon;Ahn, Taekwon;Choi, Haesung;Lee, Byoungkwon;Seo, Dongkwon;Lee, Kyuhwan;Jung, Sangwoo;Yi, Jaehoon
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.8 no.3
    • /
    • pp.33-41
    • /
    • 2020
  • Purpose : Conventional Balance Measurement can only measure the center of gravity and the shaking movement of the body. As a result, it has the disadvantages of not responding to visual changes and blocking functions of variables. This study was carried out to evaluate the performance of new equipment that measures the balance of the body using changes in body segment and pressure using the acceleration sensor to compensate for the disadvantages of the existing equipment. Methods : To this end, balance ability was measured in 43 healthy male/female adults without orthopedic injuries and nervous system damage in the last 6 months. in a situation where the visual information was restricted by Virtual Reality (VR) gear, all subjects measured and evaluated the balance ability utilizing the new equipment. Balance measurement (Prime Medilab, Korea) and Wii fit (Nintendo, Japan) were used to measure the balance ability of the subjects, and the balance ability test was performed in 4 postures using each device for data acquisition. The test duration for each posture was 30 seconds. For data acquisition, the average value of three experiments measured using each equipment was analyzed, and the statistical test was performed using the independent sample and the corresponding sample t-test, and the significance level was set to α=.05. Results : As a result of measuring the balance ability using individual equipment, blocking visual information using VR gear, the average speed, maximum speed, and moving area of the COP increased equally. It was found that the obtained absolute size of the result in Wii was somewhat larger than that of BM. Conclusion : It is considered that in the future research, it is necessary to measure changes in the body's center of gravity through image analysis, etc., to make clear comparison and evaluation of the usability.

Measuring the Environment of Pig Houses (돈사의 환경계측에 관한 연구)

  • 최규홍;손재룡;이강진;최동수;최용삼;남상일
    • Journal of Animal Environmental Science
    • /
    • v.7 no.3
    • /
    • pp.155-164
    • /
    • 2001
  • Environmental factors such as $NH_3,\;H_2S,\;CO_2$, dust, temperature, and humidity in the animal house are a potential health hazard to humans and animals. Until now, most of measurement methods can only provide periodic results with low accuracy. A data acquisition system which can measure continuously and simultaneously $NH_3,\;H_2S,\;CO_2$, temperature, and humidity was developed and installed in two pig houses. Daily changes of environment for the pig-houses were investigated by the data acquisition system. In order to evaluate NH$_3$sensor, gas samples were obtained and NH$_3$concentrations were measured at nine positions; combinations of three positions(inlet, middle, and outlet) and three heights(0 cm, 40 cm, 150 cm). Ammonia concentration of 14.0 ~37.1 ppm for slurry pig-house is higher than that of 8.4~29.7 ppm for scraper pig-house, and there were no statistical differences among the positions. However, the concentration of $NH_3$at 150 cm was higher than thats of 0 cm and 40 cm.

  • PDF

Comparison of the I-V Characteristic as Various Composition ratio of Iodine in a-Se of $BrO_2/a-Se$ based Radiation Conversion Sensor ($BrO_2/a-Se$ 구조의 방사선 변환센서에서 a-Se에 첨가된 조성비 변화에 따른 I-V 특성 비교)

  • Choi, Jang-Yong;Park, Ji-Koon;Gong, Hyun-Gi;Ahn, Sang-Ho;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.440-443
    • /
    • 2002
  • Present1y the X-Ray diagnosis system is a real condition that is changing by digital ways in it's existent analog ways. This digital radiation detector is divided by the direct method and the indirect method. The indirect method of applied voltage has special qualities that the resolution is low than direct method by diffusion effect that happens. The conversion process ( radiation${\rightarrow}$visible ray${\rightarrow}$electrical signal of two times, has shortcomings that the energy conversion efficiency of electrical signal is low. The direct method has shortcomings that need strong electric fie1d to detect electrical signal efficiently. This research achieved to develop digital detector of the Hybrid method that have form that mixes two ways to supplement shortcoming of direct. indirect method. A studied electrical characteristic by Iodine's Mixture ratio change is added to selenium in the detector which has a multi-layer structure (Oxybromide + a-Se). There are 8 kinds of Manufactured compositions to amorphous selenium Iodine each 30ppm, 100ppm, 200 ppm, 300ppm, 400ppm, 500ppm, 600ppm, 700ppm by a doped photoconductor through a vacuum thermal evaporation method. The phosphor layer is consisted of Oxybromide ($BrO_2$) which uses optical adhesives multi-layer structure. The manufactured compositions calculates and compares Net Charge and signal to noise ratio measuring Photocurrent about Darkcurrent and X-ray. When doped Iodine Mixture ratio is 500ppm to the multi-layer structure (Oxybromide + a-Se), applied voltage of $3V/{\mu}m$, leakage current of compositions $2.61nA/cm^2$ and net charge value by 764pC/$cm^2$/mR then the best result appeared.

  • PDF