• 제목/요약/키워드: Measuring sensor

검색결과 1,960건 처리시간 0.028초

Sensor array optimization techniques for exhaled breath analysis to discriminate diabetics using an electronic nose

  • Jeon, Jin-Young;Choi, Jang-Sik;Yu, Joon-Boo;Lee, Hae-Ryong;Jang, Byoung Kuk;Byun, Hyung-Gi
    • ETRI Journal
    • /
    • 제40권6호
    • /
    • pp.802-812
    • /
    • 2018
  • Disease discrimination using an electronic nose is achieved by measuring the presence of a specific gas contained in the exhaled breath of patients. Many studies have reported the presence of acetone in the breath of diabetic patients. These studies suggest that acetone can be used as a biomarker of diabetes, enabling diagnoses to be made by measuring acetone levels in exhaled breath. In this study, we perform a chemical sensor array optimization to improve the performance of an electronic nose system using Wilks' lambda, sensor selection based on a principal component (B4), and a stepwise elimination (SE) technique to detect the presence of acetone gas in human breath. By applying five different temperatures to four sensors fabricated from different synthetic materials, a total of 20 sensing combinations are created, and three sensing combinations are selected for the sensor array using optimization techniques. The measurements and analyses of the exhaled breath using the electronic nose system together with the optimized sensor array show that diabetic patients and control groups can be easily differentiated. The results are confirmed using principal component analysis (PCA).

광학식 3차원 좌표측정장치를 이용한 관성항법센서와 기체의 정렬기법 (Alignment of Inertial Navigation Sensor and Aircraft Fuselage Using an optical 3D Coordinate Measuring Device)

  • 김정호;이대우
    • 한국항공우주학회지
    • /
    • 제47권1호
    • /
    • pp.41-48
    • /
    • 2019
  • 본 논문은 광학적인 방법을 통해 얻은 3차원 좌표들을 이용하여 항공기 동체와 관성항법센서를 정렬하는 방법에 대하여 다루고 있다. 기존에 가공되어 있는 마운트 홀의 제작 정확도를 신뢰하고 장착하던 관행에서 나아가 관성항법센서의 좌표계와 항공기 동체의 기준좌표계를 보다 정확하게 정렬하기 위한 방법에 대해 소개하고 있으며, 실현가능성을 검증하기 위해 실제 3차원 좌표측정장치의 오차 수준을 반영한 시뮬레이션을 통해 정렬 성능을 검증하였다. 또한 광학센서와 관성항법센서의 최적화 기법 기반 정렬 방법을 기술하였다.

스마트폰을 이용한 Infant Care 시스템의 프로트 타입모델 설계 및 구현 (Design and Implementation of Prototype Model for Infant Care system using Smart Phone)

  • 최성재
    • 한국인터넷방송통신학회논문지
    • /
    • 제22권4호
    • /
    • pp.103-109
    • /
    • 2022
  • 수면 중 발생되는 영유아의 높은 사망률 때문에 영유아 케어에 대한 중요성이 대두되고 있다. 본 연구에서는 블루투스 기술을 이용하여 스마트폰 으로 제어되는 Infant Care 디바이스의 초기 모델을 개발하였다. 개발된 모델은 MCU, 가속도 센서, 온도 측정 센서, 소리 센서, 블루투스 모듈, 카메라 모듈로 구성된다. 개발된 어플리케이션과 블루투스 기술을 사용하여 측정된 유아의 낙상 감지 신호 정보, 울음 감지 신호 정보, 발열 감지 신호 정보를 부모의 스마트폰과 컴퓨터 모니터를 통해 표출 하였다. Bluetooth Low Energy를 이용하여 저 전력 구동을 구현함으로서 구현된 Infant Care 시스템의 초기 설계모델의 유용성에 대해 확인 하였다.

광커넥터의 반사를 이용한 다중화된 굽힘 손실형 단일모드 광섬유 변위센서 (Multiplexed Bend Loss Type Single-Mode Fiber-Optic Displacement Sensor Using Reflection Signals Generated at Optical Connectors)

  • 유정애;조재흥;권일범
    • 한국광학회지
    • /
    • 제15권5호
    • /
    • pp.415-422
    • /
    • 2004
  • 교량과 각종 건물을 비롯한 대형 토목 구조물에서 발생하는 수 mm의 변위를 한 개의 광섬유로 간편하게 측정하기 위하여 광커넥터에서 반사가 굽힘 손실에 의하여 변하는 현상을 이용한 새로운 다중화된 광섬유 변위센서를 제안하고 실험하였다. 한 쌍의 광커넥터 양끝에서 반사광의 신호차이가 두 광커넥터 사이에서 발생한 굽힘 변위에 의해서 달라지는 것을 Optical Time Domain Reflectometer로 측정하여 선형으로 그 변화가 측정되는 변위센서를 만들고, 이 센서 4개를 직렬형으로 배열하여 여러 지점의 변위를 동사에 측정이 가능한 다중화 센서 시스템을 구성하고 실험하였다. 그 결과 이 변위센서를 이용하면 4개 지점에서 각각 최대 6 mm까지의 변위를 6%의 오차범위 내에서 0.9942의 선형성을 가지고 변위를 측정할 수 있음을 확인하였다.

6.6 kV 케이블의 절연저항 측정을 위한 부하전류 및 온도 측정 (Load Current and Temperature Measurement for Measuring the Insulation Resistance of the 6.6 kV Cable)

  • 박용규;조영식;이관우;엄기홍;박대희
    • 한국전기전자재료학회논문지
    • /
    • 제28권1호
    • /
    • pp.46-50
    • /
    • 2015
  • The cable degradation process is largely divided into three steps; Step 1 : Thermal degradation, Step 2 : Weibull degradation, Step 3 : Partial discharge. it is progress in step order. This article aims to explain the process of cable degradation using the method of insulation resistance and accordingly to compose and manufacture a system of measuring the life of electrical cable. Before measuring the insulation resistance, a system of measuring the temperature and current of cables was made, and the established system was installed for test on the site of a power plant to collect the measured data. The current sensor was used TFC30P80A-CL420, and temperature sensor was used the DK-1270 PT100 sensor as RTD sensor. When measured the temperature and the load current at the same position, was confirmed that in case of the load current value was high, also temperature value high. Therefore, the correlation between load currents and temperature was verified, and the analysis of diagnostic data was evaluated, which could be utilized in identifying the fault condition of cable systems.

Monitoring of tension force and load transfer of ground anchor by using optical FBG sensors embedded tendon

  • Kim, Young-Sang;Sung, Hyun-Jong;Kim, Hyun-Woo;Kim, Jae-Min
    • Smart Structures and Systems
    • /
    • 제7권4호
    • /
    • pp.303-317
    • /
    • 2011
  • A specially designed tendon, which is proposed by embedding an FBG sensor into the center king cable of a 7-wire strand tendon, was applied to monitor the prestress force and load transfer of ground anchor. A series of tensile tests and a model pullout test were performed to verify the feasibility of the proposed smart tendon as a measuring sensor of tension force and load transfer along the tendon. The smart tendon has proven to be very effective for monitoring prestress force and load transfer by measuring the strain change of the tendon at the free part and the fixed part of ground anchor, respectively. Two 11.5 m long proto-type ground anchors were made simply by replacing a tendon with the proposed smart tendon and prestress forces of each anchor were monitored during the loading-unloading step using both FBG sensor embedded in the smart tendon and the conventional load cell. By comparing the prestress forces measured by the smart tendon and load cell, it was found that the prestress force monitored from the FBG sensor located at the free part is comparable to that measured from the conventional load cell. Furthermore, the load transfer of prestressing force at the tendon-grout interface was clearly measured from the FBGs distributed along the fixed part. From these pullout tests, the proposed smart tendon is not only expected to be an alternative monitoring tool for measuring prestress force from the introducing stage to the long-term period for health monitoring of the ground anchor but also can be used to improve design practice through determining the economic fixed length by practically measuring the load transfer depth.

CMOS 이미지 센서를 사용한 방사선 측정에 관한 연구 (A Study On Radiation Detection Using CMOS Image Sensor)

  • 이주현;이승호
    • 전기전자학회논문지
    • /
    • 제19권2호
    • /
    • pp.193-200
    • /
    • 2015
  • 본 논문에서는 CMOS 이미지 센서를 사용한 방사선 측정 알고리즘 및 장치의 구성을 제안한다. CMOS 이미지 센서를 사용한 방사선 측정 알고리즘은 CMOS 이미지 센서에 입사된 방사선 입자 판별 알고리즘과 CMOS 이미지 센서로 매초 수 십장의 이미지에 입사된 방사선 입자에 대한 픽셀 수의 누적 및 평균을 기준으로 하는 방사선 수치 측정 알고리즘을 사용한다. CMOS 이미지 센서에 입사된 방사선 입자 판별 알고리즘은 입사된 방사선 입자의 이미지를 R, G, B로 분할하고 각각의 이미지에 대해 명암 및 백그라운드와 입자를 구별할 수 있는 임계값 설정 조정을 통하여 측정한다. 방사선 수치 측정 알고리즘은 설정된 주기에 따른 CMOS 이미지 센서로 매초 수 십장의 이미지에 입사된 방사선 입자수를 누적 저장, 평균을 통하여 방사선 수치를 측정한다. 제안된 알고리즘의 검증을 위한 하드웨어 장치는 CMOS 이미지 센서 및 이미지 시그널 프로세서부, 제어부, 전원회로부, 디스플레이부 등으로 구성된다. 제안된 CMOS 이미지 센서를 사용한 방사선 측정에 관하여 실험한 결과는 다음과 같다. 첫 번째로 저가의 CMOS 이미지 센서를 사용하여 방사선 입자 판별 측정 실험을 통해 고가의 GM Tube의 측정 구간별 특성과 대체로 유사한 특성을 나타낼 수 있음을 확인할 수 있었다. 두 번째로 저가의 CMOS 이미지 센서로 방사선 수치 측정 실험을 통해 고가의 GM Tube가 나타내는 선형 특성과 대체로 유사한 특성을 나타냄을 확인할 수 있었다.

Measurement of 3D Spreader Position Information using the CCD Cameras and a Laser Distance Measuring Unit

  • Lee, Jung-Jae;Nam, Gi-Gun;Lee, Bong-Ki;Lee, Jang-Myung
    • 한국항해항만학회지
    • /
    • 제28권4호
    • /
    • pp.323-331
    • /
    • 2004
  • This paper introduces a novel approach that can provide the three dimensional information about the movement of a spreader by using two CCD cameras and a laser distance measuring unit in order to derive ALS (Automatic Landing System) in the crane used at a harbor. So far a kind of 2D Laser scanner sensor or laser distance measuring units are used as comer detectors for the geometrical matching between the spreader and a container. Such systems provide only two dimensional information which is not enough for an accurate and fast ALS. In addition to this deficiency in performance, the price of the system is too high to adapt to the ALS. Therefore, to overcome these defects, we proposed a novel method to acquire the three dimensional spreader information using two CCD cameras and a laser distance measuring unit. To show the efficiency of proposed method, real experiments are performed to show the improvement of accuracy in distance measurement by fusing the sensory information of the CCD cameras and a laser distance measuring unit.

원통형 4손가락 힘측정시스템 개발 (Development of four-finger force measuring system of a cylindrical type)

  • 김갑순
    • 센서학회지
    • /
    • 제19권5호
    • /
    • pp.349-355
    • /
    • 2010
  • Stroke patients, etc. can't use their hands because of the paralysis of their fingers, and their fingers could be recovered by rehabilitating training. In order to judge the rehabilitating extent of their fingers, the patients should grasp a cylindrical object in hospital. At present, the used object in hospital is only a cylindrical object, and can't measure the force of fingers. Therefore, doctors judge the rehabilitating extent by touching and watching at their fingers. So, the four-finger force measuring system which can measure the force of their fingers should be developed. In this paper, four-finger force measuring system with four force sensors which can measure the grasping force is developed. The force sensors are designed and fabricated, and the force measuring device is designed and manufactured by using DSP(digital signal processing). Also, the grasping force test of men is performed by using the developed four-finger force measuring system. It was confirmed that the finger average force of right hand is about 214.6 N and that of left hand is about 212.8 N.

재실 감지 센서를 이용한 다용도 스마트 센서 개발 (Development of Multi-purpose Smart Sensor Using Presence Sensor)

  • 차주헌;용흥
    • 한국생산제조학회지
    • /
    • 제24권1호
    • /
    • pp.103-109
    • /
    • 2015
  • This paper introduces a multi-purpose smart fusion sensor. Normally, this type of sensor can contribute to energy savings specifically related to lighting and heating/air conditioning systems by detecting individuals in an office building. If a fire occurs, the sensor can provide information regarding the presence and location of residents in the building to a management center. The system consists of four sensors: a thermopile sensor for detecting heat energy, an ultrasonic sensor for measuring the distance of objects from the sensor, a fire detection sensor, and a passive infrared sensor for detecting temperature change. The system has a wireless communication module to provide the management center with control information for lighting and heating/air conditioning systems. We have also demonstrated the usefulness of the proposed system by applying it to a real environment.