• Title/Summary/Keyword: Measuring methods

Search Result 4,453, Processing Time 0.028 seconds

대한신경외과학회지에 발표된 요통 환자의 치료결과 평가방법 (Methods Measuring the Outcome of Patients with Low Back Pain in the Papers of Journal of Korean Neurosurgical Society)

  • 이경석;도재원;윤석만;배학근;윤일규
    • Journal of Korean Neurosurgical Society
    • /
    • 제30권5호
    • /
    • pp.581-585
    • /
    • 2001
  • Objectives : Criteria for evaluating the results of treating low back pain vary widely. We examined the methods measuring the outcome in the papers of Journal of Korean Neurosurgical Society. Methods : We selected all published articles describing the methods measuring the outcome of low back pain in the journal. They were classified into 3 periods such as period 1 for volume 1-20, 2 for volume 21-25, and 3 for volume 26-28. Results : There are 25 articles in period 1, 44 in period 2, and 30 in period 3. The outcome was classified into 0 to 5 classes by more than 15 different methods. Although the terms and descriptive criteria differ, 4 classes were the most common classification, being 16 in period 1, 39 in period 2, and 19 in period 3. The outcome was usually measured by authors' own method in period 1. In period 2, criteria by Gill et al was most commonly used along with many different criteria. Criteria by Prolo et al became a common method in period 3. Conclusion : Varying methods compromised comparative analyses of outcome. A more simple and universally applicable criteria is necessary to facilitate comparisons among various methods of treatment.

  • PDF

Auto-Measurement of Induction Motor Parameters

  • Kim Kyung-Seo;Byun Sung-Hoon
    • Journal of Electrical Engineering and Technology
    • /
    • 제1권2호
    • /
    • pp.226-232
    • /
    • 2006
  • This paper presents the parameter measurement methods for high performance drive of induction motors, which are suitable for the self-commissioning function of commercial inverters. In this study, some factors that affect the accuracy of parameter measurement are examined. Measuring methods and conditions that are best fit to each parameter measurement procedure are then proposed. All the measurement procedures can be done without any auxiliary equipment, so that those can be easily adopted as self-commissioning functions of commercial inverters. To improve the measuring accuracy, least square approximation methods are adopted during the measurement procedure. The validity of the proposed methods are confirmed through experiments.

산란선 제거용 X선격자의 실험방법의 새로운 시도 (Improvement Study on Measuring Method of X-Ray Grid Characteristics)

  • 허준;김정민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제10권1호
    • /
    • pp.69-74
    • /
    • 1987
  • Authors attempted grid performance test by film methods than can be used easily on the hospital. And we investigated the utility of it comparing with the values measured by fluorescence meter recommended to be used ordinarily. The result was that, the characteristic values obtained by film methods was almost the same as those obtained by fluorescence meter methods. And besides plain film methods that can be applied simply showed small standard deviation. Therefore, we considered that it can be adopted easily on the labor that was not ready for special measuring apparatus like fluorescence meter.

  • PDF

디젤기관의 NOx 저감방법 및 NOx 측정에 관한 연구 (A Study on the Method of NOx Reduction and NOx Measurement for the Diesel Engines)

  • 남정길;김준효;최주열
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2002년도 춘계학술대회논문집
    • /
    • pp.193-199
    • /
    • 2002
  • According to the NOx level requirement of annex Vl to IMO(International Maritime Organization) MARPOL 73/78, this regulation shall apply to each diesel engine with a power output of more than 130 ㎾ which is installed on a ship constructed and undergoes a major conversion on or after 1 January 2000. It is inevitable to adopt IMO standard for marine engines. Therefore, most of diesel engines which are being currently built should be tested and surveyed in accordance with the NOx technical code. In this study, various technics of NOx reduction methods were investigated for the diesel engines and the methods of NOx measuring were introduced by the new and simplified field detecting equipment. These results can be utilized for the basic design and developement of diesel engine for NOx reduction.

  • PDF

A Review on the Radioisotopic Methods for Measuring Bacterial Production in Aquatic Environments

  • Hyun, Jung-Ho;Larock, Paul A.
    • Journal of the korean society of oceanography
    • /
    • 제31권2호
    • /
    • pp.97-106
    • /
    • 1996
  • Advantages and disadvantages of four radioisotopic methods, $^{3}H$-thymidine, $^{3}H$-adenine, $^{3}H$-leucine, and $^{35}S$-sulfate, for measuring bacterial production were reviewed. The maior issues discussed in production methods were: (1) whether all the actively growing bacteria take up the radiolabeled (organic) tracers; (2) how each target molecule should be purified (nonspecific labeling); and (3) how important the determination of the precursor pool specific activity is (internal isotope dilution). Since all the radioisotoic methods have their own advantages and disadvantages, careful consideration must be paid in choosing the radioisotope according to the conditions of each environment investigated.

  • PDF

깃각 자동측정 프로그램의 신뢰도와 타당도 평가 (An Evaluation of the Reliability and Validity of the Automatic Pennation Angle Measuring Program)

  • 김종순
    • PNF and Movement
    • /
    • 제17권2호
    • /
    • pp.329-337
    • /
    • 2019
  • Purpose: Ultrasound imaging is commonly used to measure the pennation angle of human skeletal muscles in vivo. However, manual assessment of the pennation angle using ultrasound images is subjective and time-consuming and requires a high level of examiner skill. The architectural analysis of human skeletal muscles is thus challenging. Automated approaches using image processing techniques are therefore required to estimate the pennation angle in ultrasound images. The purpose of this study was thus to assess the intra-tester and inter-tester reliability and validity of the pennation angle using an automatic measurement program. Methods: Twenty-two healthy young adults (mean age = 22.55 years) with no medical history of neurological or musculoskeletal disorders voluntarily participated in this study. Ultrasound imaging was used to measure the pennation angle of the gastrocnemius muscle at rest. One examiner acquired images from all the participants. The intra-tester and inter-tester reliability were evaluated using the intraclass correlation coefficient (ICC) to estimate reliability. Validity was measured using Pearson's correlation coefficient. Results: The intra-rater reliability was excellent for the automatic pennation angle measuring program and the manual pennation angle assessment method (ICC>0.95). The inter-rater reliability was also excellent for both methods (ICC>0.93). All the correlation coefficients for the automatic pennation angle measuring program and the manual pennation angle assessment method were 0.79, which indicated a significantly positive correlation (p<0.05). Conclusion: Pennation angle measurement using the automatic pennation angle measuring program showed acceptable reliability and validity. This study therefore demonstrated that the automatic measuring program was able to automatically measure the pennation angle of skeletal muscles using ultrasound images, and thus made it easy to investigate skeletal muscle architecture.

A Study of Optical Properties of Intraocular Lenses and of Measurement of the Index of Reflection for an Unknown Liquid

  • Joo, Won Don;Jung, Mee Suk
    • Journal of the Optical Society of Korea
    • /
    • 제16권3호
    • /
    • pp.236-242
    • /
    • 2012
  • In general, such methods as interferometers or wavefront sensors are commonly used for testing of an optical system and optical components. In these cases, the surrounding environments are unlikely to affect the measurements. On the other hand, intraocular lenses of hydrophilic materials with special properties experience a certain difficulty in testing the optical properties. An intraocular lens is dried in the air, which causes deformation and changes the optical characteristics such as index of refraction and thickness. Thus, it is hard to measure the optical characteristics of an intraocular lens by using common methods. In this study, a special structure is used for measuring of the transmission wavefront aberration and effective focal length of an intraocular lens of hydrophilic materials by using a Shark-Hartmann sensor among the various measuring methods. As an application of this measuring method, this study shows a simple method to measure the index of refraction of unknown liquids with a plano-convex lens with a well known index of refraction. Also, this method is used to measure the optical properties of a plano-convex such as index of refraction and curvature by using a liquid with a well known index of refraction.

직접측정과 3차원 측정에 따른 인체치수 및 의복 착장 비교분석 (Comparative Analysis of Body Measurement and Fit Evaluation between 2D Direct Body Measuring and 3D Body Scan Measuring)

  • ;임호선;천종숙
    • 복식문화연구
    • /
    • 제19권6호
    • /
    • pp.1347-1358
    • /
    • 2011
  • This study purposed to analyze differences in body measurement between the 2D direct body measuring method and the 3D body scan measuring method and to perform the appearance evaluation and cross-sectional evaluation of the fit of pants to which body measurements obtained by each measuring method were applied. Body measuring was conducted in 10 women in their 20s-30s using 2D direct body measuring and 3D automatic measuring with Hamamatsu body scanner. Among the 10 women, 3 participated in experimental garment wearing. Experimental pants were made using their 2D direct body measurements and 3D automatic measurements, and wearing tests were performed through expert evaluation and cross-sectional evaluation. The results of the experiment were as follows. According to the results of comparative analysis on differences between 2D direct body measurements and 3D scan measurements, 3D automatic measurements were significantly larger in bust circumference, ankle circumference, armscye circumference, shoulder length, scye depth, and arm length. As circumferences measured with the 3D body scanner were somewhat larger than directly measured ones, it is suggested to adjust ease when using existing pattern making methods. We prepared experimental garments by the same pattern making method through applying body measurements obtained with the two measuring methods, and assessed the fit of the garment comparatively through expert evaluation and 3D scan cross-sectional evaluation. According to the results, 2D-pants using 2D direct body measurements was slightly tighter than 3D-pants using 3D measurements in waist circumference, hip circumference, and abdominal circumference. In the results of comparing appearance in terms of the fit of the experimental garment in each subject, significant difference was observed in most of the compared items. This result suggests that 3D automatic body measuring data may show different accuracy according to body shape and therefore it is necessary to examine difference between 2D direct body measurements and 3D automatic measurements according to body shape.

Measuring the Earth's Size Using the Sun's Altitude and The Responses

  • Chae, Dong-Hyun
    • 대한지구과학교육학회지
    • /
    • 제5권1호
    • /
    • pp.88-94
    • /
    • 2012
  • This study was created to resolve the problems embedded in the formal measuring experiments to determine the earth's size in the current curriculum, to develop an updated measuring experiment to determine the earth's size and to establish its effect. For this study, pre-service elementary teachers, who had attempted the experiment of measuring the size of the earth when they were in middle school, performed the experiments in the existing national curriculum, and their responses, collected through in-depth interviews, were examined. To begin with, the pre-service elementary teachers conducted the experiment of measuring the earth size and they recorded the problems while performing it. At the end, an in-depth interview was administered. Based on the problems, an updated measuring experiment to determine the earth's size was suggested to be applied to the same contents and be analyzed through the in-depth interviews. Common themes which were mutually categorized and analyzed by the two researchers were obtained based on the records produced while conducting the experiment and the in-depth interview data. The teachers mentioned that the experiments for measuring the size of the earth in the current curriculum gave rise to difficulties in measuring precisely the angles between the string and the post. Also, there has been a scientific contradiction that solar altitudes were increased in a high latitude region, instead of decreased. For this reason, an alternative method has been developed to measure the earth's size using the distance and the solar altitude difference of two places. The teachers all agreed that by using the updated measuring experiment, they can acquire more precise measurements and it is easier, faster and consequently more effective than the existing methods. Through the results of this study, I suggest that the newly developed experiment by the researchers can overhaul the problems of the current experiments and it can be an effective alternative to the current experiment.

원통금형의 전자빔 가공을 위한 PR 코팅 및 측정 팁을 이용한 두께측정 (PR Coating for Electron Beam Lithography of Cylindrical Mold and Measuring Coating Thickness of It using Measuring Tip)

  • 이승우;김정오;서정
    • 한국정밀공학회지
    • /
    • 제29권10호
    • /
    • pp.1144-1148
    • /
    • 2012
  • Process conditions for generating nano patterns handle different process according to the pattern characteristics, and different process data according to patterns in questions. To efficiently find optimal process conditions for generating nano patterns, process data by experiment is needed consideration of the pattern characteristics concerning the equipment. In particular, coating methods of a cylindrical mold differ from it of a flat plate because of viscosity of coating materials. Also the coating thickness affects nano process and pattern line width. So coating method of coating thickness for cylindrical mold is very important on nano pattern generating. In this study, a method is proposed for coating Photo Resist through the spray in order to coat cylindrical mold and measuring the thickness of coating using measuring tip considering the size of cylindrical mold because there is no method in the existing SEM. The proposed method is applied to a real printed electronics system to verify its accuracy and efficiency.