• 제목/요약/키워드: Measuring methods

검색결과 4,453건 처리시간 0.03초

공정서 수재 의약품의 정량법 개선에 관한 연구 (Establishment of Quantitative Method for Generic Drugs in Korea Pharmaceutical Codex Monograph)

  • 송재용;장진섭;장승은;김선회;김인규;이길봉;이제만;김용희
    • 약학회지
    • /
    • 제56권5호
    • /
    • pp.288-292
    • /
    • 2012
  • The aim of the paper is to ameliorate old research methods of Korean Pharmaceutical Codex to adjust the newest scientistic level which is necessary to maintain quality of medical supplies effectively. After reviewing result of Establishment of Dissolution Specifications for Generic Drugs in Korea Pharmaceutical Codex Monograph, there are two items chosen for the methods - Establishment of Dissolution Specifications for Generic Drugs in Korea Pharmaceutical Codex Monograph which KFDA researched in 2010, arranged new measuring standard by having an experiment to set measuring method after obtaining each item. According to the result, The experiment includes a measuring method of two items; Nafronyl Oxalate Capsules, and Ticlopidine Hydrochloride Tablets. The research is ameliorated by research methods through several experiments such as High Performance Liquid Chromatography validation, preparing items, implement of trial-experiment and authentic experiment, and experiment on measuring method of regulations of Korea Pharmaceutical Codex. The experiments are taken opinions of experts in KFDA into consideration and wrote out a report of the new measuring method on each last item. The report is combined as each two experiment sections of analyzing method to maintain the quality on the basis of the research in 2010 on setting of dissolution specifications for oral solid dosage forms. The result of measuring method of medical supplies through modernizing trial method of oral solid dosage forms is available to be accurate. In conclusion, this study could contribute to promotion of public health by organizing a basis for safe and high quality of medical supplies in domestic market.

터널계측용 록볼트축력계와 지중변위계의 불량원인 파악과 검증방법에 대한 연구 (A study on the methods of identifying and verifying the causes of defects on rock bolt stressmeter and rod extensometer)

  • 김영배;노원석;이성원;전훈민;이강일
    • 한국터널지하공간학회 논문집
    • /
    • 제24권5호
    • /
    • pp.411-429
    • /
    • 2022
  • NATM 터널에서 계측은 필수 불가결한 요소이나 계측기의 신뢰도를 검증할 방법, 절차, 규정 등에 대한 연구가 부족함으로 인해 터널에서 계측기가 성능검증 절차 없이 설치 및 적용되고 있다. 본 연구에서는 국내외 계측 검·교정 관련 규정을 조사하고 공인 인정기준의 필요성을 제시하였다. 또한 터널계측기 중 록볼트 축력계와 지중변위계를 대상으로 계측기의 불량원인을 외관검사로 파악하였으며 성능검사를 위해 단계별 하중 재하가 가능한 검증 장치를 개발하여 국내 9개 계측제조업체의 정밀계측기 불량원인을 파악하였다. 개별센서 위주의 성능테스트도 중요하나 완제품 상태에서 검증 절차를 통과해야 함이 필수적이므로 이에 따른 성능검사 방법과 절차를 제시하였다. 본 연구를 통하여 향후 계측기 성능검증을 위한 관련 규정 마련과 현장에서 계측기를 선정하는 데 도움이 될 것으로 판단된다.

Development of Diode Based High Energy X-ray Spatial Dose Distribution Measuring Device

  • Lee, Jeonghee;Kim, Ikhyun;Park, Jong-Won;Lim, Yong-Kon;Moon, Myungkook;Lee, Sangheon;Lim, Chang Hwy
    • Journal of Radiation Protection and Research
    • /
    • 제43권3호
    • /
    • pp.97-106
    • /
    • 2018
  • Background: A cargo container scanner using a high-energy X-ray generates a fan beam X-ray to acquire a transmitted image. Because the generated X-rays by LINAC may affect the image quality and radiation protection of the system, it is necessary to acquire accurate information about the generated X-ray beam distribution. In this paper, a diode-based multi-channel spatial dose measuring device for measuring the X-ray dose distribution developed for measuring the high energy X-ray beam distribution of the container scanner is described. Materials and Methods: The developed high-energy X-ray spatial dose distribution measuring device can measure the spatial distribution of X-rays using 128 diode-based X-ray sensors. And precise measurement of the beam distribution is possible through automatic positioning in the vertical and horizontal directions. The response characteristics of the measurement system were evaluated by comparing the signal gain difference of each pixel, response linearity according to X-ray incident dose change, evaluation of resolution, and measurement of two-dimensional spatial beam distribution. Results and Discussion: As a result, it was found that the difference between the maximum value and the minimum value of the response signal according to the incident position showed a difference of about 10%, and the response signal was linearly increased. And it has been confirmed that high-resolution and two-dimensional measurements are possible. Conclusion: The developed X-ray spatial dose measuring device was evaluated as suitable for dose measurement of high energy X-ray through confirmation of linearity of response signal, spatial uniformity, high resolution measuring ability and ability to measure spatial dose. We will perform precise measurement of the X-ray beamline in the container scanning system using the X-ray spatial dose distribution measuring device developed through this research.

MEASUREMENT THE PATHS OF FARM MACHINERY USING AN OPTICAL WAVE RANGE FINDER

  • Shigeta, Kazuto;Chosa, Tadashi;Nagsaka, Yoshisada;Sato, Junichi
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1996년도 International Conference on Agricultural Machinery Engineering Proceedings
    • /
    • pp.591-597
    • /
    • 1996
  • To straighten the path that farm machinery follows in paddy fields, it is necessary to measure and evaluate the tracks that these machines leave behind. However, there are no known methods for making such measurements and evaluations since it is difficult to accurately trace the paths that the machine make in paddy fields. Therefore, a measuring system has been developed which can accurately recored the path of a farm machinery in a field by measuring the horizontal straight-line distance from the side of the field to the machine. This system consists of a track subsystem on the machine and a range finder system. A measuring appraratus is installed on a flatcar which runs on rails over 50 m long at the side of the filed. The track subsystem uses a CCD camera to track the movement of the machine in the field which is following a lengthwise path. The range finder subsystem measures the distance that the measuring apparatus has traveled on the rails and the distance from the app ratus to the machine in the field. This system makes it possible to record the path that the machine travels. Even though differences in traveling distance arise between the measuring apparatus and the farm machine, these differences are detected by image processing , which allows the machine in the field to be located accurately. The short(0.05 second) time required for image processing is enough to follow an object . In the present study, this system was able to measure the path that a moving tractor makes. Even though a lag of up to 0.4 meters occurred, this system did not miss its target during operation of the track subsystem. Thus the path measuring system developed here is able to record vehicle paths automatically by following the movement of vehicles in the field and measuring the distance to them. It is expected to come into use in such applications as unmanned moving vehicle tests.

  • PDF

Multi-measuring기법을 이용한 원전 제어밸브의 누설진단 (Leakage Monitoring of Control Valves for Nuclear Power Plants Using Multi-measuring)

  • 김성영;김영범;김봉호;이상국
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.3458-3463
    • /
    • 2007
  • Leakage would happen because of the damage of high temperature and high-pressure valve in nuclear power plant. condition based prevention maintenance is essential by using the suitable method based on local condition. Energy loss prevention can prevent from an accurate test, Local actually and ability. The methods of test for high energy fluid leakage at present are analysis of ${\Delta}$T, AE(Acoustic Emission) analysis, and thermal image. The result for test of AC (Main steam) system in YNG 2 Unit reveals that the AE occurred clearly in leakage situation, but thermal image didn't occur. It is identified that leakage is occurred when the orifice located front and back of valve operates. It shows that making a impatient judgment by using the single method if it is leakage is containing uncertainty. So I think that using the Multi-Measuring method is more sound judgment than Single-Measuring method.

  • PDF

R을 이용한 KS Q ISO 22514-7 측정 프로세스 능력 분석용 프로그램 (A Statistical Program for Measurement Process Capability Analysis based on KS Q ISO 22514-7 Using R)

  • 이승훈;임근
    • 품질경영학회지
    • /
    • 제47권4호
    • /
    • pp.713-723
    • /
    • 2019
  • Purpose: The purpose of this study is to develop a statistical program for capability analysis of measuring system and measurement process based upon KS Q ISO 22514-7. Methods: R is a powerful open source functional programming language that provides high level graphics and interfaces to other languages. Therefore, in this study, we will develop the statistical program using R language. Results: The R program developed in this study consists of the following five modules. ① Measuring system capability analysis with Type 1 study data: MSCA_Type1.R ② Measuring system capability analysis with Linearity study(Type 4 study) data: MSCA_Type4.R ③ Measurement process capability analysis with Type 1 study & Gage R&R study data: MPCA_T1GRR.R ④ Measurement process capability analysis with Type 4 study & Gage R&R study data: MPCA_T4GRR.R ⑤ Attribute measurement processes capability analysis : AttributeMP.R Conclusion: KS Q ISO 22514-7 evaluates measuring systems and measurement processes on the basis of the measurement uncertainty that was determined according to the GUM(KS Q ISO/IEC Guide 98-3). KS Q ISO 22514-7 offers precise procedures, however, computations are more intensive. The R program of this study will help to evaluate the measurement process.

3D체형측정기와 수동측정 방법간의 사상체질별 ${\cdot}$ 성별 진단정확률 비교연구 (Diagnosis Accuracy Rate Comparative Study of Each Sasang Constitutions and Sex Distinction by Body Measurement Method between 3D Body Measuring Instrument and Hand-operating)

  • 권석동;설유경;이의주;김규곤;김종원
    • 사상체질의학회지
    • /
    • 제19권1호
    • /
    • pp.60-77
    • /
    • 2007
  • 1. Objectives This is the comparative study with hand-operated measurement method and Automatic measurement method, in order to convert the automatic measurement method. 2. Methods We measured the body of patients(hand-operated Width 5 Places and hand-operated circumference 8 place,Automatic Width 5 and automatic circumference 8 place by 3D body measuring instrument) and analyzed the anthropometric data divding into sex&age. 362 patient's data are used in the analysis. 3. Results and Conclusions 1) 1th circumference variable which standing was not a sasang constitutional difference. 2) Diagnostic accuracy rate of the body measurement was 50-80%. 3) Diagnostic accuracy rate of man is higher than Diagnostic accuracy rate of women 4) Diagnostic accuracy rate of Automatic & hand-operated measuring was not a big difference.

  • PDF

Chair side measuring instrument for quantification of the extent of a transverse maxillary occlusal plane cant

  • Naini, Farhad B.;Messiha, Ashraf;Gill, Daljit S.
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제41권
    • /
    • pp.21.1-21.3
    • /
    • 2019
  • Background: Treatment planning the correction of a transverse maxillary occlusal plane cant often involves a degree of qualitative "eyeballing", with the attendant possibility of error in the estimated judgement. A simple chair side technique permits quantification of the extent of asymmetry and thereby quantitative measurements for the correction of the occlusal plane cant. Methods: A measuring instrument may be constructed by soldering the edge of a stainless steel dental ruler at 90° to the flat surface of a similar ruler. With the patient either standing in natural head position, or alternatively seated upright in the dental chair, and a dental photographic retractor in situ, the flat under-surface of the horizontal part of this measuring instrument is placed on a unilateral segment of a bilateral structure, e.g. the higher maxillary canine orthodontic bracket hook. The vertical ruler is held next to the contralateral canine tooth, and the vertical distance measured directly from the canine bracket to the flat under-surface of the horizontal part of the measuring instrument. Results: This vertical distance quantifies the overall extent of movement required to level the maxillary occlusal plane. Conclusions: This measuring instrument and simple chair side technique helps to quantify the overall extent of surgical levelling required and may be a useful additional technique in our clinical diagnostic armamentarium.

HATS를 이용한 헤드폰의 in situ 측정방법에 관하여 (On the in situ Measurement Method of Headphones using Head And Torso Simulator)

  • 강경옥;강성훈
    • 한국음향학회지
    • /
    • 제11권2호
    • /
    • pp.15-27
    • /
    • 1992
  • 헤드폰을 사용하여 청각실험을 하는 경우에 합리적인 헤드폰 측정방법이 확립되지 않아 그 측정방법에 따라 다른 결과를 초래하는 문제점이 있기 때문에, 헤드폰의 주파수 특성에 관한 표준 측정방법이 요구된다. 본고에서는 이러한 중요성에 입각하여 종래의 의사귀를 이용한 측정방법과 최근 새롭게 제안되고 있는 HATS를 이용한 측정방법을 사용하여, 사람에 있어서 자연적인 청취상태에 입각한 헤드폰 측정방법에 대해 고차하고, 종래의 측정방법과 비교 검토하였다. 그 결과 사람의 귀의 음향 임피던스와 머리의 회절요과를 정확히 모사하지 못한 의사귀 측정방법에 비해, 이 문제점을 해결한 HATS를 이용한 측정방법에서 사람에 있어 보다 자연적인 청취상태에 입각한 주파수 특성을 측정할 수 있었다.

  • PDF