• Title/Summary/Keyword: Measuring master

Search Result 117, Processing Time 0.023 seconds

Development of Automatic Design Program for Measuring Master Gear using Visual Lisp (Visual Lisp을 이용한 측정용 마스터기어 자동설계 프로그램 개발)

  • 김영남;이성수
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2000.10a
    • /
    • pp.169-174
    • /
    • 2000
  • This paper is about automatic design of measuring master gears. Master gears are usually thought of as gears of extreme accuracy level, but are better defined as gages to check the meshing action of production gears. This is usually not recognized because most mechanical gages are associated with static measurements rather than having the form of machine elements used in a functional check involving machine motion. In this paper the interface that allows beginners to design easily and quickly is provided. The addition and modification of data is easy and the reduced design lead time is feasible with the program even though users don't know much about program since it is developed with Visual Lisp and DCL.

  • PDF

Non-restraint Master Interface of Minimally Invasive Surgical Robot Using Hand Motion Capture (손동작 영상획득을 이용한 최소침습수술로봇 무구속 마스터 인터페이스)

  • Jang, Ik-Gyu
    • Journal of Biomedical Engineering Research
    • /
    • v.37 no.3
    • /
    • pp.105-111
    • /
    • 2016
  • Introduction: Surgical robot is the alternative instrument that substitutes the difficult and precise surgical operation; should have intuitiveness operationally to transfer natural motions. There are limitations of hand motion derived from contacting mechanical handle in the surgical robot master interface such as mechanical singularity, isotropy, coupling problems. In this paper, we will confirm and verify the feasibility of intuitive Non-restraint master interface which tracking the hand motion using infra-red camera and only 3 reflective markers without the hardware handle for the surgical robot master interface. Materials & methods: We configured S/W and H/W system; arranged 6 infra-red cameras and attached 3 reflective markers on hands for measuring 3 dimensional coordinate then we find the 7 motions of grasp, yaw, pitch, roll, px, py, pz. And we connected Virtual-Master to the slave surgical robot(Laparobot) and observed the feasibility. To verify the result of motion, we compare the result of Non-restraint master and that of clinometer (and protractor) through measuring 0~180 degree, 10degree interval, 1000 samples and recorded standard deviation stands for error rate of the value. Results: We confirmed that the average angle values of Non-restraint master interface is accurately corresponds to the result of clinometer (and protractor) and have low error rates during motion. Investigation & Conclusion: In this paper, we confirmed the feasibility and accuracy of 3D Non-restraint master interface that can offer the intuitive motion of non-contact hardware handle. As a result, we can expect the high intuitiveness, dexterousness of surgical robot.

Measurement of Motion Accuracy by Two-dimensional Probe on NC Machine Tools -2nd Report, Measurement of the Linear Motion Accuracy- (2차원 프로브에 의한 NC공작기계의 운동 정밀도 측정 -제2보 직선운동 정밀도 측정-)

  • JEON, Eon Chan;OYAMADA, Shigenori;TSUTSUMI, Masaomi;KAKUTA, Junichro
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.7
    • /
    • pp.15-21
    • /
    • 1997
  • This paper presented a linear motion accuracy by using two-dimensional probe with the master block and the square for NC machine tools. This measuring system could be measured motion error due to numerical control system. The results of measurement and simulation for motion error were similar, and so, this system had enough accuracy to measure a linear motion accuracy for NC machine tools. The experimental results are as follows. 1. This measuring system could be measured motion error due to mumerical control system. 2. The results of measurement and simulation for motion error were similar. 3. This measuring system had enough accuracy to measure a linear motion accuracy for NC machine tools.

  • PDF

Measurement of Axis Squireness by using Reversal Method (반전법을 이용한 축 직각도 측정방법)

  • Lee C.W.;Song J.Y.;Ha T.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.436-439
    • /
    • 2005
  • In general a square master and a dial gauge are used to measure the axis squareness on the spot. This method is a comparison measurement and its accuracy depends on the square accuracy wholly. Therefore the accuracy of a square master is very important and it is impossible that the accuracy of a square measurement is superior to the accuracy of a square master. In this paper, the new method of square measurement is proposed for measuring square without a square master and easily. This method is an absolute measurement by using a reversal method and can be used to measurement the accuracy of a square master.

  • PDF

MARGINAL FIDELITY AND FRACTURE STRENGTH OF IN-CERAM CROWNS ACCORDING TO VARIOUS RESIN CEMENTS (접착재의 종류에 따른 In-Ceram 도재관의 변연적합도와 파절강도에 관한 연구)

  • Lim, Ju-Hwan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.6
    • /
    • pp.888-899
    • /
    • 1998
  • In-Ceram system is one of contemporary esthetic all ceramic restorations and has relatively high flexural strength. The purpose of this study was to evaluate the marginal fidelity according to type of resin cement and measuring position, and to evaluate fracture strength according to type of resin cement. In this study, twenty seven In-Ceram crowns were fabricated on the metal master die of prepared maxillary right central incisor and devided into three groups. All specimens were cemented with Panavia 21 (group PV), Super-bond (group SB) and Lute-it (group LI) on the metal master die. After cementation, specimens were measured marginal gap between the margin of the In-Ceram crown and the finishing line of metal master die by using a stereomicroscope (SZ-ST, Olympus, Japan). Marginal gaps were recorded at the labial, lingual, mesial and distal measuring points on the metal master die. For the mesurement of fracture strength, lingual surfaces of cemented specimens were loaded at a distance of 1mm from incisal edge by using the Autograph S-2000 (Shimadzu, Japan). The results of marginal fidelity and fracture strength were statistically analyzed with the SPSS version 8.0 programs. The results of this study were as follows: 1. In comparison of marginal fidelity according to the measuring points, there was no significant difference. 2. The marginal fidelity according to the type of resin cement was decreased in order of group $LI\;(63.75{\mu}m),\;SB\;(77.78{\mu}m),\;PV\;(86.53{\mu}m)$, and there was significant difference between group LI and PV (p<0.05). 3. The fracture strength according to the type of resin cement was showed descending order of group $LI\;(60.00kg/cm^2),\;SB\;(56.80kg/cm^2),\;PV\;(56.11kg/m^2)$, but there was no significant difference.

  • PDF

A Study on the Uncertainty Estimation of Flowmeter Calibrator with Two Master Flowmeters (2개의 기준유량계를 이용한 유량계 교정장치의 측정불확도 평가에 관한 연구)

  • Choi Jong Oh;Lee Woan Kyu;Lim Ki Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.10
    • /
    • pp.1219-1230
    • /
    • 2004
  • Comparing to the gravimetric and volumetric method, the flowmeter calibration based on the master meter method is relatively economical and convenient, especially for high flowrate. The uncertainty of flow quantity and flowrate using the master meter method was evaluated according to the GUM (Guide to the Expression of Uncertainty in Measurement). In order to apply for the wider flow range, two master meters (electromagnetic flow meter) were employed as reference flowmeters. The uncertainty of the master meter was obtained by combining the statistical variation of the repeated measurements and the variation of fluid density and pipe material due to temperature and pressure changes were scrutinized. for a practical application, the uncertainty of calibrator, whose measuring capacity of 1000 ㎥/h obtained by employing two 500 ㎥/h electromagnetic How meters, was evaluated. The uncertainty budget shows the quantitative contribution of each uncertainty component to the overall uncertainty of the calibrator. As a result, it was found that the dominant uncertainties were from the master meter, which was evaluated statistically, and from the process of least squares fitting. On the contrary, the uncertainties arising from the variation of the fluid density and the pipe volume due to the temperature and pressure were negligible.

A Study on the Master Plan of the Temple Site of Baekje Period (백제 사찰 조영계획 고찰)

  • Tahk, Kyung-Baek
    • Journal of architectural history
    • /
    • v.20 no.4
    • /
    • pp.7-28
    • /
    • 2011
  • This study intends to investigate the measuring scales, locations and scales through arrangement plans for a research on construction plans. Through an analysis of the artifacts-measuring scales, the relation of two scales found, which further helped suppose the measuring scales applied during the foundation period. Southern dynasties-scale was still used even after the capital was transferred to Sabi till Tang-scale was introduced. Tang-scale was used for Buddhist temples mostly founded in the 7th century. On the other hand, Goguryo-scale seemed to be used almost at the same period as Southern dynasties-scale used, but it seemed that Goguryo-scale disappeared earlier than Southern dynasties-scale. The locations of Buddhist temples could be classified into mountains, flatlands and mountain valley. Buddhist temples founded in mountains were mostly small-sized, but ones located on flatlands could secure flat fields through mounding operations. In addition, through location conditions of Neungsa and Wangheungsa, it was possible to find out the district setting of Sabi Capital Castle. Finally, the expansion range of Buddhist temples were found to be towards the east and the west. As for the scales of temples according to such conditions of location, it was found a similarity in Temple sites. In general, it was possible to assume that the scales of Buddhist temples tended to be expanded along with spatial expansion and there were regular systems in Buddhist temples related to the Royal family. Through the analysis of arrangement plans between individual buildings, it was found that the basic arrangement of Gate-Pagoda-Main Hall-Lecture Hall was preserved, but the proportion of distances between individual buildings varied depending on cases. As a result, there were differences between scales of entire building sites, construction subjective influences and master plan for each location of a Buddhist temple.

Analysis of Master Dimensional Shape Error Rate According to Reverse Engineering Technique (역설계 방법에 의한 시편 치수 형상의 오차율 분석)

  • Jung, Hyun-Suk;Park, Su-Jung;Yoo, Joong-Hak
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.25 no.5
    • /
    • pp.393-399
    • /
    • 2016
  • In this study, an experiment was conducted using a 3D scanner, commonly used in reverse engineering techniques, and the newly introduced CT measuring machine. The hole, width, and angle of specimens having various shapes were designated, the error rates in dimensional modelling generated during scanning with each device were compared, and the models were printed using a 3D printer. A secondary comparative analysis of the two printed specimens was conducted; the causes of dimension errors that occur during the printing process after scanning with each device and the differences associated with variation in shape were also analyzed. Based on the analysis results, the featured shape for each scanning application method and issues to consider in reverse engineering were presented, and the use of the CT measuring machine was recommended as a method to minimize error rates in dimensions and ensure efficient reverse engineering.

EFFECT OF IMPRESSION TECHNIQUE ON THE ACCURACY OF MASTER CAST FOR IMPLANT PROSTHESIS (인상채득방법이 임플란트 주모형의 정확성에 미치는 영향)

  • Kim Young-Oh;Yang Hong-So
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.2
    • /
    • pp.238-247
    • /
    • 2004
  • Statement of problem: Major objective in making on implant-supported prosthesis is the production of superstructure that exhibits a passive fit when connected to multiple abutments. One requirement to ensure passive fit is to make an accurate impression. Purpose : The purpose of this study was to compare the accuracy of master cast fabricated by using different impression methods at the different impression levels. Material and method: The master model used in this study was resin block having low implant analogs. Impression method studied were 1) direct method on fxiture level (Group FIX-D), 2) indirect method on fixture level(Group FIX-I), 3) modified indirect method on fixture level(Group FIX-M), 4) direct method on abutment level(Group AB-D) and 5) indirect method on abutment level(Group AB-I). Each of the five groups took 10 impressions. Fifty impressions were made for master cast by using Impregum $F^{(R)}$ impression material loaded on individual tray. Three dimensional measuring microscope was used to measure the inter-implant distance. Error rate of each inter-implant distance were calculated and evaluated. Results : The results were as follows. 1. Group FIX exhibited higher accuracy than group AB. 2. In group FIX, modified indirect method showed the highest accuracy, while indirect method showed the lowest accuracy. In group Ab, indirect method showed the higher accuracy than direct method. 3. Group FIX showed larger horizontal error than group AB. But, group AB showed the larger vertical error than group FIX. 4. Group Fix-M showed smallest vertical and horizontal error. Conclusion: An impression method have more effect on accuracy of master model than an impression level. A modified indirect method showed smallest vertical and horizontal error.

Distance measurement using Zigbee communication solution (Zigbee 통신 solution을 이용한 거리 측정)

  • Kim, Young-Keun;Hur, Chang-Wu
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.10
    • /
    • pp.1830-1834
    • /
    • 2008
  • At the present day, devices for measurement and control of data by wireless based computer have been generalized. The devices with low cost and high performance have been spotlighted. If Zigbee communication solution is used in dangerous places and places that can not in use wire communication, computer can process data without limitation. Zigbee communication solution is effective in power consumption as compared with RF or bluetooth and can use battery. System cost of Zigbee also is very low, so can install lots of nodes. The system made in this paper transmit by wireless many LMCs(Laser Measuring Control) of wireless transmission system for distance measurement and many slave Zigbee to a master Zigbee.