• 제목/요약/키워드: Measuring machine

검색결과 969건 처리시간 0.029초

마이크로흘 드릴링 머신의 개발 및 절삭성능 평가 (Development of Micro-hole Drilling Machine and Assessment of cutting Performance)

  • 김민건;유병호
    • 한국공작기계학회논문집
    • /
    • 제10권5호
    • /
    • pp.39-44
    • /
    • 2001
  • In this paper, drill fred mechanism, cutting depth measuring device and sensing buzzer of drill contact were investigated in order to develop the micro-hole drilling machine. Also, measuring device of cutting resistance was developed in order to estimate cutting resistance from change of cutting condition. The results show that extremely-low fled rate(less then $17{\mu}m/S$${\mu}{\textrm}{m}$ /s) can be done and cutting depth can be measured by up to 1${\mu}{\textrm}{m}$ with developed drilling machine. Accordingly we could assemble a very cheap micro-hole drilling machine($\phi$ 0.05~0.5 mm). Also we got the some properties of cutting performance i.e. under the same condition, cutting torque decreases as increase of spindle speed and rapid fled of drill brings about the inferior cutting state under low spindle speed.

  • PDF

3차원 자동체형계측기 정밀도 검사 (An Accuracy Analysis of the 3D Automatic Body Measuring Machine)

  • 전수형;권석동;박세정;김정양;송정훈;김현진;김종원
    • 사상체질의학회지
    • /
    • 제20권1호
    • /
    • pp.42-47
    • /
    • 2008
  • 1. Objectives The Body Shape and Feature is one of the important standard for classification of Sasang Constitutions. In order to evaluate one's Body Shape and Feature objectively we have been developing the Body Measuring Machine. Now we develop the 3D Automatic Body Measuring Machine(3D-ABMM). So we make an analysis of the 3D-ABMM's Accuracy. 2. Methods By using the 3D-ABMM and Vivid 9i(3D laser scanner, Konica Minolta) we have a surface scan of the three objects which are the upper body of the female and male Manikin and a male model. We overlap each scan data using the RapidForm2006 (3D scan data solution, INUS Technology) and calculate the average distance and standard deviation between the same point of each scan data. 3. Results and Conclusions In the female Manikin, the average distance is 0.84mm and the standard deviation is 1.16mm and the maximum distance is 10.68mm. In the male Manikin, the average distance is 1.12mm and the standard deviation is 1.19mm and the maximum distance is 12.00mm. In the male model, the average distance is 3.26mm and the standard deviation is 2.59mm and the maximum distance is 12.75mm. From the results, 3D-ABMM has good accuracy for scanning body and will be a usable hardware of the 3D Automatic Body Analysis Machine.

  • PDF

캠 형상 전용 측정기 제어 및 해석 S/W 개발 (Control and data analysis of a measuring machine for cams)

  • 최동우;강재관
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 추계학술대회 논문집
    • /
    • pp.150-153
    • /
    • 1997
  • In this paper, a control and data analysis S/W of a dedicated measuring machine for cams is developed. A rotary encoder is employed to measure the angular displacement of the motor, and a linear scale does the linear displacement of the prove. The design and measuring data are interpolated by cubic spline curves respectively to compute the error which is defined by the maximum distance between two curves. Further, optimization module to find the exact error is also developed to remove the error occurred due initial measuring position. The developed system takes only 6 minutes to measure the cam and to analyze the measuring data while the CMM takes about 1 hours even with a skilled operator.

  • PDF

Micro Step Motor의 위치정밀도측정 시스템 개발 (Development of the Position Measuring System of Micro Step Motor)

  • 노병옥;김안식;유영기;성하경
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집B
    • /
    • pp.70-75
    • /
    • 2001
  • In this study, we developed a measuring system utilizing machine vision for measuring the precision of positioning of micro stepping motor. The measuring system equipped with CCD Camera, ring illumination and diffuser measures the repeatability and the hysterisis of a micro stepping motor by means of the pointer attached to the motor directly. With the measuring system, it was possible to measure the precision of the micro stepping motor in the resolution of $50{\mu}m$.

  • PDF

3차원 좌표 측정기의 Software에 의한 Volumetric 오차 교정 (Volumetic Error Compensation of a Coordinate Measuring Machine using a Software Method)

  • 박준호;이응석;양종화;조소형
    • 한국정밀공학회지
    • /
    • 제11권4호
    • /
    • pp.158-164
    • /
    • 1994
  • A volumetric error compensation method was stueide with measuring systematic error of a Coordinate Measuring Machine(CMM). The volumetric error equations were proposed for a Moving Bridge type CMM. Using the error equations, error vectors in the measuring volume were corrected by a software method. The CMM was controlled by the compensation program separately in the measuring and moving function of the CMM proving. The linear accuracy of the CMM was measured by the Laser Interferometer and compared with the data before the volumetric error compensation. This method was proved as low cost and effective to reduce the systematic error of the CMM, as no hardware modification is required.

  • PDF

반사경 측정을 위한 타워 방식의 Fold Mirror를 이용한 Fizeau 간섭계 시스템 구성 (A Study on the Tower type Fizeau Interferometer System with a Fold Minor for Measuring Large Optical Lens Profile)

  • 이응석;이기암;김옥현
    • 한국정밀공학회지
    • /
    • 제25권8호
    • /
    • pp.21-28
    • /
    • 2008
  • Fizeau interferometer is used for inspecting the lens surface profile accurately. This study is focused on the design and optical measuring techniques for large optical components, such as a reflection mirror for large area lithography or astronomical purpose. A tower type Fizeau interferometer is designed and set up in horizontally with a 45$^{\circ}$ fold mirror which makes easy to align the optical path of heavy interferometer system. To align the optical path, a five-axes stage for the interferometer is required. This study shows a method of the 45$^{\circ}$ fold mirror alignment by using a three-axis stage instead of adjusting the interferometer itself or measuring object. This system will be installed on the large optics polishing machine during the manufacturing process as an on-machine inspection system.

신뢰도를 고려한 측정시스템의 개선 (High Accuracy Measuring System on the Machine Tool by Neasurement Error Compensation)

  • 공민규;정성종
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1993년도 추계학술대회 논문집
    • /
    • pp.527-532
    • /
    • 1993
  • MascMC system is one of the MMC system module which performs measuring and checking of machined workpieces on the machine tools. Accuracy of the MascMC was compensated for developing a reliable measuring system by measurement error calibration. Reference gauges, ring gauges, block gauges,squares, spheres and cylindrical squares, were used for error identification and compensation. .+-. 10 .mu. m accuracy with 95% confidence interval was confirmed on the vertical and the horizontal machining center through the large number of experiments.

  • PDF

선박 엔진용 캠 전용 측정기의 데이터 취득 및 해석 (Data Acquisition and Analysis of a Measuring Machine for Marine Engine′s Cams)

  • 강재관;이경휘
    • 한국정밀공학회지
    • /
    • 제19권11호
    • /
    • pp.160-166
    • /
    • 2002
  • In this paper, data acquisition and analysis of a measuring machine for marine engine's cams is discussed. A rotary encoder and linear scale of the machine to measure angular and linear displacement respectively are interfaced to the PC via encoder board with 2 channels. The design and measuring data are interpolated by cubic spline curves to compute the precision error which is defined by the maximum and minimum distances between two curves. The minimum zone fit of ISO is employed to evaluate the geometric deviation. The developed system takes only 5 minutes to measure and analyze while the CMM takes over 1 hours even with a skilled operator.

Data acquisition and analysis of an exclusive measuring machine for marine engine′s cams

  • Dong-Woo;Jae-Gwan
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제5권4호
    • /
    • pp.21-27
    • /
    • 2004
  • In this paper, data acquisition and analysis of a measuring machine for marine engine's cams are discussed. A rotary encoder and linear scale of the machine to measure angular and linear displacement, respectively, are interfaced to the PC via an encoder board with 2 channels. The design and measuring data are interpolated by cubic spline curves to compute the precision error which is defined by the maximum and minimum distances between two curves. The minimum zone fit of ISO is employed to evaluate the geometric deviation. The developed system takes only 5 minutes to measure and analyze the precision error while the CMM takes over I hours even with a skilled operator.