A Case of Schwannoma Arising from the Right Lateral Tongue (혀의 우측 측부에 발생한 신경초종 1예)

  • Joung, Ho-Hoon;Park, Chan-Hum;Choi, Young-Hee;Lee, Jun-Ho
    • Korean Journal of Head & Neck Oncology
    • /
    • v.23 no.2
    • /
    • pp.192-194
    • /
    • 2007
  • Schwannoma, also named neurilemmoma, is a rare solitary and slow-growing tumor which originates from schwann cells of the nerve sheath. Schwannoma is a well-circumscribed, encapsulated masses that is attached to the nerve but can be separated from it. On microscopic examination, tumors show a mixture of two growth patterns, Antoni A and B. Surgical excision is the treatment of choice. Especially, Schwannoma of the tongue is very rare. We present a case of a 11-year-old child with a schwannoma of the tongue, measuring $1{\times}1cm$. During the operation the mass revealed itself as being encapsulated. The tumor was removed and diagnosed pathologically as a schwannoma.

Characteristics of Flow Coefficients in an Engine Cylinder Head with a Quasi-steady Flow Condition by Continuous Variation of the Valve Lift (밸브 양정의 연속 변화에 의한 준정상 유동 조건에서의 엔진 실린더헤드 유량계수 특성)

  • Oh, Dae-San;Lee, Choong-Hoon
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.6
    • /
    • pp.22-27
    • /
    • 2010
  • Flow Coefficients of intake port in an engine cylinder head were measured by a newly designed flow rig. In measuring the flow coefficient with traditional method, the valve lift was manually varied by technician with adjusting a micrometer which is directly connected to the intake valve of the cylinder head. The cam shaft of the cylinder head is directly rotated by a step motor and the valve lift was automatically varied with cam shaft profile in the newly designed flow rig. The measurement of the flow coefficient was automated by rotating the cam shaft with the step motor. Automatic measurement of the flow coefficient could be safely measured by separating a technician from the noise and vibration of the traditional flow rig. Also, the automatic measurement of the flow coefficient reduce the measurement time and provide meaningful statistical data.

A Clinical Case Study on Avascular Necrosis of Femur Head Complaining Lower Extremity Pain with Oriental Medical Treatment (하지 통증을 주소로 하는 대퇴골두 무혈성 괴사 환자에 대한 한방치료 증례보고 1례)

  • Kim, Koh-Woon;Kim, Sung-Soo;Lee, Jong-Soo;Chung, Seok-Hee
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.5 no.1
    • /
    • pp.137-143
    • /
    • 2010
  • This study was performed to report the effectiveness of oriental medical treatment on a patient with avascular necrosis of femur head complaining lower extremity pain. The patient was diagnosed as avascular necrosis of both femur head and treated with acupuncture, cupping therapy, physical therapy and herbal medicine. We have evaluated the efficacy of oriental medical treatment by measuring changes of visual analogue scale and range of motion according to period of hospitalization. After treatment, pain and range of motion were improved. These results suggest that oriental medical treatment was effective on the patient with avascular necrosis of femur head.

  • PDF

A Study on the Automatic Measurement of Swirl Generated fi:om Intake Port of Engine Cylinder Head Using an I-IEEE-1394 Camera and Step Motors (IEEE-1394카메라와 스텝모터를 이용한 엔진 실린더헤드의 흡기포트 스월 측정 자동화에 관한 연구)

  • Lee Choong-Hoon
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.14 no.6
    • /
    • pp.88-94
    • /
    • 2005
  • A swirl ratio of a charge in the cylinder could be calculated by measuring both the rotary speed of paddle and the intake air flow rate in the swirl measurement apparatus fur several positions of valve lift. The automation of the swirl ratio measurement for a cylinder head is achieved by controlling both the valve lift of cylinder head and a suction pressure of the surge tank, instead of controlling them manually. PID control of the surge tank pressure and positioning a valve lift of the cylinder head are also achieved by using two step motors, respectively. Rotating speed of a paddle are measured using an optical sensor and a counter. Flow rate are measured from ISA 1932 flow nozzle by reading a differential pressure gauge position using IEEE-1394 camera. Time to measure the swirl ratio for a port in the cylinder head is drastically reduced from an hour to 3 minutes by automation control of the apparatus.

Rotational Stability and Lubrication State Evaluation of the Polishing Head for High Speed Polishing (폴리싱 고속화를 위한 연마헤드의 회전 안정성과 윤활 상태 평가)

  • Lee, Hocheol;Choi, Minseok
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.25 no.4
    • /
    • pp.301-306
    • /
    • 2016
  • High speed polishing can kinematically increase the polishing removal rate by using the conventional Preston equation, especially for hard substrates such as sapphire or diamond. However, high speed effects should be clarified beforehand considering the lubrication state and process parameter variations. In this paper, we developed a polishing experimental method and apparatus to determine the lubrication state by measuring the real time friction coefficient using two load cells. Through experiments, we obtained a boundary lubrication state above 0.35 of the friction coefficient by using low table speed and high polishing load, indicating a synchronized stable behavior in polishing head rotation. However, larger Stribeck indexes by a high speed above 200 rpm can generate a hydrodynamic lubrication state below 0.25 of the low friction coefficient. This causes the polishing head rotation to stop. A forced and synchronized head rotation is required for high speed polishing.

Modeling HRTFs for Customization (맞춤형 머리전달함수 구현을 위한 모델링 기법)

  • Shin, Ki-H.;Park, Young-Jin;Park, Yoon-Shik
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.641-644
    • /
    • 2005
  • This study reveals some recent attempt in modeling empirically obtained B&K HATS (Head and Torso Simulator) HRTFs (Head Related Transfer Functions) to Isolate parameters that stimulate lateral and elevation perception. Localization using non-individual HRTFs often yields poor performance in synthesizing virtual sound sources when applied to a group of individuals due to differences in size and shape of head, pinnae, and torso. For realization of both effective and efficient virtual audio it is necessary to develop a method to tailor a given set of non-individual HRTFs to fit each listener without measuring his/her HRTF set. Pole-zero modeling is applied to fit HRIRs (Head Related Impulse Responses) and modeling criterions for determining suitable number of parameters are suggested for efficient modeling. Horizontal HRTFs are modeled as minimum-phase transfer functions with appropriate ITDs (Interaural Time Delay) obtained from RTF (Ray Tracing Formula) to better fit the size of listener's head for usage in simple virtualizer algorithms without complex regularization processes. Result of modeling HRTFs in the median plane is shown and parameters responsible for elevation perception are isolated which can be referred to in the future study of developing customizable HRTFs.

  • PDF

Effects of Head Posture and Occlusal Splint on Swallowing Movement (두부자세 및 교합장치에 따른 연하운동의 변화)

  • Sung-Jin Moon;Kyung-Soo Han
    • Journal of Oral Medicine and Pain
    • /
    • v.21 no.1
    • /
    • pp.55-65
    • /
    • 1996
  • This study was performed to investigate the effects of head posture and occlusal splint on the vertical dimension in mandibular rest position and swallowing. Thirty health dental students ware selected lot this study and BioEGNⓡ(Bioresearch Inc., USA) was used for measuring interocclusal distance during rest - swallowing - rest - tapping movement. This swallowing movements were observed in both normal head posture(NHP) and forward head posture (FHP). Thickness of occlusal splint was about 2mm at posterior molar area and even tooth contact were achieved on light biting. The four mandibular positions at which interocclusal distance measured were swallowing position, after swallowing position in which interocclusal distance was maximum, rest position follows swallowing, and tapping position after rest. Changes of distance in each position were measured for three mandibular planes, that is, sagittal, frontal, and horizontal plane, respectively. The results obtained were as follows : 1. In normal head posture, the mandible was raised 1.03mm without splint, and 0.77mm with splint on swallowing, and there was no significant difference between the two. In horizontal plane, however, mandible was displaced more anteriorly in both swallowing position and tapping position with splint. 2. In forward head posture, the mandible was less raised with splint on swallowing, but features in horizontal plane were almost same as those in normal head posture. 3. In natural dentition, significant difference between NHP and FHP were observed in horizontal plane trajectory for swallowing and tapping position. But the difference for same positions were observed in frontal trajectory with splint. 4. Total amount of mandibular movement of two groups classified with sagittal interocclusal distance of swallowing position generally showed significant difference between the higher and the lower height group in head posture without splint. 5. Correlationship among total amount of mandibular movement for three mandibular planes were observed between sagittal plane and horizontal plane, and between sagittal plane and frontal plane in head posture without splint.

  • PDF

A Study on the Head and Neck Posture Related to Cervical Curvature in Patients with Craniomandibular Disorders (경추만곡도를 이용한 두개하악장애에 환자의 두경부자세에 관한 연구)

  • Min-Shin;Kyung-Soo Han
    • Journal of Oral Medicine and Pain
    • /
    • v.20 no.2
    • /
    • pp.361-376
    • /
    • 1995
  • The purpose of this study was to investigate the relationship between the head and neck postre and the cervical curvature, especially in forward head postrue(FHP). Sixty patients with craniomandibular disorders and thirty dental students without any signs and symptoms of craniomandibular disordres participated in this study as patient groups and sa control group, respectively. The author evaluated the head and neck posture of all subjects by plumb line and CROM( Cervical Ragne of Motion), and had taken cephaograph in natural head position. On the cephalograph the angle of cervical inclination formed by true horizntal plane and 4th cervical vertebra(C4) and the radius of cervical curvature from C1 to C5 were measured. A specially designed ruler was used for measuring cervical curvature. Occlusal contac number and force with T-scan system, electromygraphic activity of cervical muscles with Bio-EMG, and distance of freeway space with Bio-ECN were recorded, respectively. The collected data were processed by SAS/STAT progrm. The obtained results were as follows : 1. In subjects with longer radius which was less cervical curvature, head positioned more anteriorly than subjects with smaller radius, and they showed slightly straight cervical vertebra. 2. Between the patients and the control group, there were no differences in cervical curvature, in forward head position by plumb line and in CROM. But the patient group had a greater cervical inclination than the control group had. 3. There were positive correlation between cervical curvature and forward head position by plumbline,between forward head position y plumb line and that by CROM in patient group. The cervical inclination, however, had negative correlation with cervical curvature, and with forward head postion by plumb line, respectively. 4. In case of showing more cervical curvature and more forward head position by plumb line the head position was defined as forward head posture. In patient group, subjects without forward head posture showed greater posterior teeth contact force than subjects with forward head posture, but in control group, there were no difference between the two subjects. 5. There were higher electromyographic activity in almost all muscles and smaller freeway space in induced forward head posture than those in natural head position in subjects without forward head posture. In conclusion, head position of patients with craniomandibular disorders were not more anterior than that of normal control person, but they had tendency to head extension. From the result of this study, forward head posture could be defined as posterior rotation of upper cervical segment with a straight lower cercial segment due to loss of normal lordosis.

  • PDF

Implementation of the Pulse Wave Measurement System Using Bipolar Biased Head on Mode of the Hall Sensor (홀 센서의 양극 바이어스 수직모드를 이용한 맥파측정시스템 구현)

  • Jin, Sang-Gon;Kim, Myoung-Nam
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.322-328
    • /
    • 2011
  • There are many ways to detect the heart rate non-invasively such as ECG, PPG, strain gauge, and pressure sensor. In this paper, the pulse wave measurement system using bipolar biased head on mode of the Hall sensor is proposed for measuring the radial artery pulse. TMS320F2812 was used to implement the proposed system and a portable wireless network(zig-bee) was used to show the experimental result. It was confirmed from experiment that the performance of the implemented system was more stable and faster than PPG sensor or piezoelectric film pressure sensor.

Development of Bridge Circuit for Measuring Pressure Wave in Inkjet Head (잉크젯 압력파 측정을 위한 브리지 회로 개발)

  • Kwon, Kye-Si;Myung, Jae-Hwan;Joo, Young-Cheol;Lee, Sang-Wook;Kim, Kug-Weon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.4
    • /
    • pp.342-347
    • /
    • 2008
  • Bridge circuit was developed such that the pressure wave in the inkjet can be measured. In order to test the circuit, the microfab single ejector was used. For the experiment, the head was filled with nano silver ink (20wt%). In order to generate waveform voltage for jetting signal, the Agilent 33120 was used in order to generate arbitrary waveform. For the driver, PZD 350 from TREK was used in order to amplify the waveform. Experimental results show that the designed circuit can effectively detect the pressure wave in the inkjet head.