• 제목/요약/키워드: Measuring head

검색결과 407건 처리시간 0.028초

Reliability of implant stability measuring devices depending on various clinical conditions: an in vitro study

  • Han-Na Lee;Myoung-Sub Kim;Jeong-Yol Lee;Xu Zihan;Jae-Jun Ryu;Ji-Suk Shim
    • The Journal of Advanced Prosthodontics
    • /
    • 제15권3호
    • /
    • pp.126-135
    • /
    • 2023
  • PURPOSE. The aim of this study was to evaluate the reliability of implant stability measuring devices depending on the location of the implant and the position of the patient. MATERIALS AND METHODS. Six implants were installed in different dentate sextants of six artificial bone models. Implant stability was measured in three conditions of the bone model (without mounting on a phantom head, mounted on a phantom head in supine position, and mounted on a phantom head in upright position). A resonance frequency analysis device (Osstell) and two damping capacity analysis devices (Periotest and Anycheck) were used to measure implant stability. The values measured outside the phantom head were treated as controls, and the values inside the phantom head were compared using an independent t-test. RESULTS. Osstell showed different results in two of the six divisions in both the supine and upright positions compared to outside of the mouth (P < .05). Periotest showed different results in all six parts in the supine position and in five parts in the upright position compared to outside of the mouth (P < .05). While Anycheck showed different results in five areas in the supine position compared to outside of the mouth, it showed different results in only one area in the upright position (P < .05). CONCLUSION. In the difficult implant position for the operator to access, the implant stability measuring devices show less reliability. The accessibility of implant is greatly affected in the order of Osstell, Anycheck, and Periotest.

전방머리자세 대상자의 머리-척추각과 목 운동범위, 근력, 목빗근 두께와의 상관관계 분석 (Correlation Analysis between Cervical-Vertebra Angle and Neck Range of Motion, Muscle Strength, and Sternocleidomastoid Thickness)

  • 강민지;박근태;한진태
    • 대한물리치료과학회지
    • /
    • 제31권1호
    • /
    • pp.88-97
    • /
    • 2024
  • Background: This study was to investigate effects of Correlation Analysis between Cervical-Vertebra Angle and Neck Range of Motion, Muscle Strength, Sternocleidomastoid Thickness of Patients with Forward Head Posture Design: Correlation Analysis. Methods: The subjects of this study were a total of 54 people in the forward head position and their ages were between 30 and 50 years old. The subjects cranio-vertebral angles, neck extension, neck flexion, neck rotation angles, neck flexor strength, neck extensor strength, sternocleidomastoid thickness were evaluated through measuring instruments. The thickness of the sternocleidomastoid muscle was measured using an imaging ultrasound diagnostic device (ultra sound, Versana Premier, GE Medical systems, China). CVA was measured by measuring the side photo of the subject was taken with a camera and evaluated.. neck joint range of motion was measured through digital inclinometer for extension, flexion, and neck rotation. neck muscle strength was measured by measuring the using a digital sthenometer. Data analysis in this study was statistically processed using SPSS version 26.0 (IBM SPSS Inc., USA). Correlation analysis was used and the statistical significance level was set at 0.05. Results: The results neck extension(r= 0.70**), neck flexion(r= 0.67**), neck rotation(r= 0.56**), neck extensor muscle strengt(r= 0.85**), neck flexor muscle strength(r= 0.66**), sternocleidomastoid thicknes(r= -0.81**) It indicates that there is a correlation. Conclusion:These results improve the Cervical-vertebra angle of patients with forward head posture should include a program to improve the thickness of the SCM. In the future, study can be used as an evidentiary material for treatment interventions to improve the Cervical-vertebra angle of patients with forward head posture.

QSCC II 체질과 두면부 계측항목의 연관성 분석 (Analysis of the Relationship between Sasang Constitution and Measuring Items of the Head and Face)

  • 박수진;양재하;김광중;권영규
    • 동의생리병리학회지
    • /
    • 제21권1호
    • /
    • pp.270-280
    • /
    • 2007
  • The objectives of study are to investigate the relationship between Sasang Constitution(四象醫學) and measuring items of the head and face and to develop useful diagnosis standard of Sasang Constitution. Subjects took QSCCII(Questionnaire for the Sasang Constitution Classification II) tests repeatedly at an interval of one year and were diagnosed as same constitutions. The 9 Items were measured by Martin-type anthropometric method in 112 subjects. Compared with measurements of 3 constitutions, the mean values in Taeeum-in(太陰人) showed highest and there were significant differences in 7 items between Taeeum-in(太陰人) and other constitutions. Especially, Measurements of Bitragus to Submandibular Arc Length(BSAL) item and Bitragus to Menton Arc Length(BMAL) item showed significant differences between Taeeum-in(太陰人) male and other constitutions male. It seems that BSAL and BMA items can differentiate Taeeum-in(太陰人) from other constitutions and these items have possibility to be a diagnosis standard of Sasang Constitution.

Comparison of Vital Capacity and Balance between Elderly Women and Young Women with Forward Head Postures According to the Use of Figure-8 brace

  • Kim, Eun-Kyung
    • The Journal of Korean Physical Therapy
    • /
    • 제31권4호
    • /
    • pp.248-253
    • /
    • 2019
  • Purpose: To improve pulmonary function and decrease in balance ability with increasing forward head position and vertebral curvature, we applied Figure-8 brace to confirm the immediate effect on vital capacity and balance and to see if it is applicable. Methods: A total of 34 elderly women aged 65 or older and young women in their 20s with FHP were screened to measure vital capacity, measuring the forced expiratory volume in 1 second (FEV1) and forced vital capacity (FVC), and measuring the foot pressure to see the change in balance. For statistical analysis, the difference between pre and post values was compared using pared t-test. Results: As a result of vital capacity measurements, there was no significant difference between FEV1 and FVC for women over 65 years old (p>0.05). Young women in their 20s had no significant difference in FEV1 (p>0.05), and FVC had significant differences (p<0.05). In measuring foot pressure to measure balance, both women aged 65 and above and young women in their 20s had a significant decrease in anterior foot pressure, and a significant increase in posterior foot pressure (p<0.05). Conclusion: The results of this study did not positively affect the vital capacity of elderly women with FHP. However, the significant increase in vital capacity of young women in their 20s suggests that contraction of the abdominal muscle is necessary during forced expiration. Therefore, it is believed that proper application and therapeutic interventions should be combined when applying Figure-8 brace.

마찰력 측정을 통한 GMR 헤드 제작용 초정밀 연마판의 특성화 (Characterization of ultra Precision Grinding Plate for GMR Head Manufacturing by Measuring Frictional Force)

  • 노병국;김기대
    • 한국정밀공학회지
    • /
    • 제20권7호
    • /
    • pp.78-83
    • /
    • 2003
  • Characterization of an ultra precision grinding plate for GMR head manufacturing is performed by measuring frictional forces between the grinding plate and the advanced ceramic Two kinds of methods of producing the precision grinding plates are presented: texturing and micro-channeling. Texturing is effective in terms of production time but micro-channeling excels in quality control. It is found that the frictional coefficient of a precision grinding plate decreases as the impregnation of diamond grain onto the precision-grinding plate progresses, and remains unchanged once the impregnation process is successfully completed, even after 100 revolutions of the precision-grinding plate against the advanced ceramic under 40 N of normal force. Therefore, the measurement of the frictional coefficient can replace costly and time-consuming process of estimating the level of impregnation of diamond grain on the precision-grinding plate, which has been performed by using scanning electron microscope, and be employed as an index to determine the level of impregnation of diamond grain.

Magnetic Orientations of Bull Sperm Separated into Head and Flagellum Treated by DTT or Heparin

  • Suga, D.;Shinjo, A.;Kurnianto, E.;Nakada, T.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제13권2호
    • /
    • pp.167-175
    • /
    • 2000
  • This paper describes the magnetic orientation of bull sperm separated into the head and the flagellum treated by DTT or heparin in a 5,400G static field. Semen samples collected from four bulls (Japanese Black) were mixed to the same sperm density. One percentage triton X-100 was used to extract the plasma membrane. The intact and demembranated sperm suspensions were treated with 20, 200, 2,000 mM DTT, 100, 1,000 or 10,000 units heparin solutions at $4^{\circ}C$ for 6 days. The decondensation of the sperm nuclei treated by DTT or heparin was examined by measuring the head area at 1, 3 and 6 days. After measuring the area, each sample was exposed to a 5,400G static magnetic field generated by Nd-Fe-B permanent magnets for 24 hours at room temperature. Results showed that the sperms were separated into the head and the flagellum through the DTT treatment. Almost of the separated heads showed that their long axis oriented perpendicularly to the magnetic lines of force, and most of the long axis perpendicularly oriented heads showed that their flat plane oriented perpendicularly in a 5,400G magnetic field. Also, the demembranation of the head tended to increase those perpendicular orientations, while those perpendicular orientations of the head declined with the decondensation of the sperm nuclei. These findings suggest that strong magnetic anisotropy for the perpendicular orientation of the long axis and the flat plane of the head occurs in the sperm nuclei in a 5,400G magnetic field. The separated flagellum showed lower parallel orientation, and the separated and demembranated flagellum showed parallel orientation to the magnetic lines of force in this magnetic field. These findings suggest that weak magnetic anisotropy of the parallel orientation of the flagellum occurs in the inside components in a 5,400G field.

모자업체의 유형별 치수체계에 관한 연구 (Study on the Sizing System of Head Gears)

  • 이진희;도월희
    • 한국생활과학회지
    • /
    • 제12권4호
    • /
    • pp.571-578
    • /
    • 2003
  • The purpose of this research was to provide basic information for enhancing sizing suitability in terms of the need for appropriate fit in head gear. The method for this research was to survey about sizing system of head gear, basic measure part, repair service. The subject of this study were 15 head gear companies. The results of this research were as follows : 1. In the sex target analysis according to company type, most of fashion brand companies were producing woman's head gear. In case of the company to produce man's head gear, sizes appeared variously. On the other hand, the sports brand companies were producing unisex head gear and safety helmet companies were producing man's one. 2. The number of size of head gear manufacturing companies were under 3 sizing system. This means that the sizing system of current head gear manufacturing company isn't various. 3. While the measuring part using currently in the company was head girth, one to be considered necessary for manufacturing of head gear except the head girth was head height.

  • PDF

Conceptual Design and Demonstration of Space Scale for Measuring Mass in Microgravity Environment

  • Kim, Youn-Kyu;Lee, Joo-Hee;Choi, Gi-Hyuk;Choi, Ik-Hyeon
    • Journal of Astronomy and Space Sciences
    • /
    • 제32권4호
    • /
    • pp.419-425
    • /
    • 2015
  • In this study, a new idea for developing a space scale for measuring mass in a microgravity environment was proposed by using the inertial force properties of an object to measure its mass. The space scale detected the momentum change of the specimen and reference masses by using a load-cell sensor as the force transducer based on Newton's laws of motion. In addition, the space scale calculated the specimen mass by comparing the inertial forces of the specimen and reference masses in the same acceleration field. By using this concept, a space scale with a capacity of 3 kg based on the law of momentum conservation was implemented and demonstrated under microgravity conditions onboard International Space Station (ISS) with an accuracy of ${\pm}1g$. By the performance analysis on the space scale, it was verified that an instrument with a compact size could be implemented and be quickly measured with a reasonable accuracy under microgravity conditions.

실린더 헤드 스월 측정 및 자동화 방법에 관한 연구 (A Study on Measurement and Automation Method of Cylinder Head Swirl)

  • 이충훈
    • 한국자동차공학회논문집
    • /
    • 제14권1호
    • /
    • pp.92-99
    • /
    • 2006
  • The swirl ratio of a charge in the cylinder was estimated by calculating the ratio of the rotary speed of charge which could be simulated from the rotary speed of paddle in the swirl measurement apparatus, to the engine speed which could be calculated by measuring intake air flow rate. The automation of the swirl ratio measurement for cylinder head was achieved by controling both valve lift in cylinder head and a suction pressure of surge tank using two step-motors. The number of measurement position for calculating mean swirl ratio was varied by adjusting the interval of valve lift. The mean swirl ratio with varying the number of measurement position showed nearly constant value. Two measurement methods for measuring the swirl ratio were compared, one was to control the suction pressure of the surge tank with PID (proportional, integral, differential) mode with by-pass valve controlled by the step motor and the other did not control the surge tank pressure by fixing the by-pass valve. The difference of the mean swirl ratio between the two measurement methods showed nearly constant value with varying the number of measurement position. This means that the w/o PID control method could be preferred to the PID control method which has been used, due to the simpleness of the swirl measurement.

두개하악장애와 두부전방자세와의 관계 (Relationship between Forward Head Posture and Craniomandibular Disorders)

  • Kyung-Soo Han
    • Journal of Oral Medicine and Pain
    • /
    • 제19권1호
    • /
    • pp.137-149
    • /
    • 1994
  • This study was performed to investigate the relationship between Forward Head Posture(FHP) and Craniomandlbular Disorders(CMDs). Many studies reported that there was some relationship between them, however, there is still controversy. So It Is necessary to observe and compare many more patients with CMDs wirh normal controls. For the study 85 patients with CMDs and 37 dental students were selected as experimentals and controls, respectively. And the experimentals were classified Into two groups, that is, TMJ internal derangement group and muscle disorders group according to clinical diagnosis. For measuring the FHP, CROM(Cervical-Range-of-Notion)was used. This goniometer is composed of three part. First, gravity goniometer for flexion and extension. Second, magnetic compass and yoke for rotational movement. And last, forward head arm and vertebra locator for forward head posture. Next T-Scan, electronic occlusal analyzer, was used for recording of occlusal contact state. Other items such as maximum opening, lateral excursion, Helkimo's anamnestic index, and muscle palpation point from Friction's craniomandibular index were checked clinically by one examiner. The result of this study were as follows : 1. In male, control group showed much more measurement in resting forward head posture than did experimental group. But there were not significant differences between groups in female subject. From this results, the author contended that CROM is new measuring system and differ from other goniometers in some aspect, so that results should be re-evaluated 2. Mean value of maximum mouth opening in nearly all groups were greater than 40mm. and mouth opening had a significant correlation with occlusal force and with anamnestic index both sex. 3. Mean value of palpation point had not any correlationship with forward head posture in both sex, but there was significant difference between upper and lower group by rounded shouldes. 4. In summary, there was no significant relationship between forward head posture and sign and symptom of Craniomandibular Disorders.

  • PDF