• Title/Summary/Keyword: Measuring Instrument

Search Result 849, Processing Time 0.026 seconds

Measuring Willingness to Pay for PM10 Risk Reductions: Evidence from Averting Expenditures for Anti-PM10 Masks and Air Purifiers (미세먼지 건강위험 감소에 대한 지불의사 측정: 마스크 착용과 공기청정기 사용에 따른 회피비용을 중심으로)

  • Eom, Young Sook;Kim, Jin Ok;Ahn, So Eun
    • Environmental and Resource Economics Review
    • /
    • v.28 no.3
    • /
    • pp.355-383
    • /
    • 2019
  • This study is to investigate whether averting costs for wearing $anti-PM_{10}$ masks and using air purifiers at home to reduce exposure from $PM_{10}$ are influenced by subjective risk perceptions and/or objective $PM_{10}$ concentration levels, whose estimates will be used to measure the willingness to pay for $PM_{10}$ risk reduction. An empirical analysis was conducted on a sample of 1,224 respondents who participated in the web-based survey in the late October of 2017. As we reflect the potential endogeniety bias in the estimation of averting cost functions of using air purifiers, the coefficients of risk perception were differed by 6~7 times. Respondents. subjective risk perceptions were influenced by individuals' knowledge, attitudes and demographic variables, as well as the levels of $PM_{10}$ concentrations in their residential region. The marginal willingness to pay for risk reductions at the mean levels of their risk perceptions were measured at 1,000 won per month from wearing $anti-PM_{10}$ masks and 6,000 won for using air purifiers respectively.

Rasch Analysis of the Clinimetric Properties of the Korean Dizziness Handicap Inventory in Patients with Parkinson Disease (파킨슨병 환자에서 한국어판 Dizziness Handicap Inventory의 라쉬 분석에 의한 임상측정 특성 평가)

  • Lee, Da-Young;Yang, Hui-Jun;Yang, Dong-Seok;Choi, Jin-Hyuk;Park, Byoung-Soo;Park, Ji-Yun
    • Research in Vestibular Science
    • /
    • v.17 no.4
    • /
    • pp.152-159
    • /
    • 2018
  • Objectives: The Korean Dizziness Handicap Inventory (KDHI), which includes 25 patient-reported items, has been used to assess self-reported dizziness in Korean patients with Parkinson disease (PD). Nevertheless, few studies have examined the KDHI based on item-response theory within this population. The aim of our study was to address the feasibility and clinimetric properties of the KDHI instrument using polytomous Rasch measurement analysis. Methods: The unidimensionality, scale targeting, separation reliability, item difficulty (severity), and response category utility of the KDHI were statistically assessed based on the Andrich rating scale model. The utilities of the orderedresponse categories of the 3-point Likert scale were analyzed with reference to the probability curves of the response categories. The separation reliability of the KDHI was assessed based on person separation reliability (PSR), which is used to measure the capacity to discriminate among groups of patients with different levels of balance deficits. Results: Principal component analyses of residuals revealed that the KDHI had unidimensionality. The KHDI had satisfactory PSR and there were no disordered thresholds in the 3-point rating scale. However, the KDHI showed several issues for inappropriate scale targeting and misfit items (items 1 and 2) for Rasch model. Conclusions: The KDHI provide unidimensional measures of imbalance symptoms in patients with PD with adequate separation reliability. There was no statistical evidence of disorder in polytomous rating scales. The Rasch analysis results suggest that the KDHI is a reliable scale for measuring the imbalance symptoms in PD patients, and identified parts for possible amendments in order to further improve the linear metric scale.

Measurement and analysis of PM10 and PM2.5 from chimneys of coal-fired power plants using a light scattering method (광산란법을 이용한 국내 석탄화력발전소 굴뚝에서 배출되는 PM10, PM2.5 측정 및 분석)

  • Shin, Dongho;Kim, Younghun;Hong, Kee-Jung;Lee, Gunhee;Park, Inyong;Kim, Hak-Joon;Kim, Yong-Jin;Han, Bangwoo;Hwang, Jungho
    • Particle and aerosol research
    • /
    • v.16 no.4
    • /
    • pp.131-140
    • /
    • 2020
  • Air pollutants emitted from chimneys of coal-fired power plants are considered to be a major source of fine particulate matter in the atmosphere. In order to manage fine particle in the chimney of a coal-fired power plant, it is necessary to know the concentration of fine particle emitted in real time, but the current system is difficult. In this study, a real-time measurement system for chimney fine particle was developed, and measurements were performed on six coal-fired power plants. Through the measurements, the mass concentration distribution according to the particle size could be secured. All six chimneys showed bimodal distribution, and the count median diameters of each mode were 0.5 and 1.1 ㎛. In addition, it was compared with the gravimetric measurement method, and it was determined that the relative accuracy for PM10 was within 20%, and the value measured using the developed measuring instrument was reliable. Finally, three power plants were continuously measured for one month, and as a result of comparing the concentration of PM10 according to the amount of power generation, it was confirmed that the PM10 discharged from the chimney increased in the form of an exponential function according to the amount of power generation.

Instrumentation Management of the Deep Soft Ground with Dredged Clay Reclaimed in the Upper (준설점토가 상부에 매립된 대심도 연약지반 계측관리)

  • Jung, Na-Young;Kang, Seung-Chan;Kim, Tae-Hyung
    • Journal of the Korean Geotechnical Society
    • /
    • v.38 no.12
    • /
    • pp.67-78
    • /
    • 2022
  • In this study, the measurement results of the coastal deep soft ground buried in the upper part of the dredged clay were analyzed and compared with the current specification standards. Based on the results, a suitable proposal was suggested for the selection, installation, data arrangement, and analysis of each instrument used in the deep soft ground improvement construction. The pore water pressure meter has a range of 1.5 times or more of the expected measurement range, considering the field conditions of the soft ground. The groundwater level meter installed in the horizontal drainage layer checks the change in the groundwater level during the embanking as well as the performance of the catchment well and the horizontal drainage layer. Therefore, it is important to manage so that the groundwater level exists inside the horizontal drainage layer during embanking. It is enough to install the inclinometer in the gravel layer below the soft ground or weathered rock with an N value of 40 or more for the deep soft ground. It seems desirable to install a screw type for differential settlement meter. However, the screw type should not settle due to its own weight. Considering that it is a dredged landfill where subsidence occurs significantly, it is sufficient to manage the tolerance of leveling at about 10 mm (L is the one-way distance (km)).

DNN Model for Calculation of UV Index at The Location of User Using Solar Object Information and Sunlight Characteristics (태양객체 정보 및 태양광 특성을 이용하여 사용자 위치의 자외선 지수를 산출하는 DNN 모델)

  • Ga, Deog-hyun;Oh, Seung-Taek;Lim, Jae-Hyun
    • Journal of Internet Computing and Services
    • /
    • v.23 no.2
    • /
    • pp.29-35
    • /
    • 2022
  • UV rays have beneficial or harmful effects on the human body depending on the degree of exposure. An accurate UV information is required for proper exposure to UV rays per individual. The UV rays' information is provided by the Korea Meteorological Administration as one component of daily weather information in Korea. However, it does not provide an accurate UVI at the user's location based on the region's Ultraviolet index. Some operate measuring instrument to obtain an accurate UVI, but it would be costly and inconvenient. Studies which assumed the UVI through environmental factors such as solar radiation and amount of cloud have been introduced, but those studies also could not provide service to individual. Therefore, this paper proposes a deep learning model to calculate UVI using solar object information and sunlight characteristics to provide an accurate UVI at individual location. After selecting the factors, which were considered as highly correlated with UVI such as location and size and illuminance of sun and which were obtained through the analysis of sky images and solar characteristics data, a data set for DNN model was constructed. A DNN model that calculates the UVI was finally realized by entering the solar object information and sunlight characteristics extracted through Mask R-CNN. In consideration of the domestic UVI recommendation standards, it was possible to accurately calculate UVI within the range of MAE 0.26 compared to the standard equipment in the performance evaluation for days with UVI above and below 8.

Reliability Analysis of Finger Joint Range of Motion Measurements in Wearable Soft Sensor Gloves (웨어러블 소프트 센서 장갑의 손가락 관절 관절가동범위 측정에 대한 신뢰도 분석)

  • Eun-Kyung Kim;Jin-Hong Kim;Yu-Ri Kim;Ye-Ji Hong;Gang-Pyo Lee;Eun-Hye Jeon;Joon-bum Bae;Su-in Kim;Sang-Yi Lee
    • PNF and Movement
    • /
    • v.21 no.2
    • /
    • pp.171-183
    • /
    • 2023
  • Purpose: The purpose of this study was to compare universal goniometry (UG), which is commonly used in clinical practice to measure the range of motion (ROM) of finger joints with a wearable soft sensor glove, and to analyze the reliability to determine its usefulness. Methods: Ten healthy adults (6 males, 4 females) participated in this study. The metacarpophalangeal joint (MCP), interphalangeal joint (IP), and proximal interphalangeal joint (PIP) of both hands were measured using UG and Mollisen HAND soft sensor gloves during active flexion, according to the American Society for Hand Therapists' measurement criteria. Measurements were taken in triplicate and averaged. The mean and standard deviation of the two methods were calculated, and the 95% limits of agreement (LOA) of the measurements were calculated using the intraclass correlation coefficient (ICC) and Bland-Altman plot to examine the reliability and discrepancies between the measurements. Results: The results of the mean values of the flexion angles for the active range of motion (AROM) of the finger joints showed large angular differences in the finger joints, except for the MCP of the thumb. In the inter-rater reliability analysis according to the measurement method, the ICC (2, 1) value showed a low level close to 0, and the mean difference by the Bland-Altman plot showed a value greater than 0, showing a pattern of discrepancy. The 95% LOA had a wide range of differences. Conclusion: This study is a preliminary study investigating the usefulness of the soft sensor glove, and the reliability analysis showed a low level of reliability and inconsistency. However, if future studies can overcome the limitations of this study and the technical problems of the soft sensor glove in the development stage, it is suggested that the measurement instrument can show more accurate measurement and higher reliability when measuring ROM with UG.

Gender Difference in the Prevalence of Disabilities in Activities of Daily Living among the Korean Elderly (한국 노인의 성별 일상생활활동 장애율)

  • Kang, Eunjeong
    • 한국노년학
    • /
    • v.27 no.2
    • /
    • pp.409-425
    • /
    • 2007
  • The purposes of this study were to compare the disability prevalence and its related factors between men and women. The data used for the analysis was the National Health and Nutrition Survey, 2005, and the instrument of measuring disability was the K-ADL which had been developed by Won(2002). Chi-square test and multivariate logistic regression were used to test the gender difference. In the bivariate analyses, women had more disabilities than men among the entire elderly and the young elderly. However, there was not gender difference of disability among the old elderly. After controlling for age and other factors related to disability, no gender differences in the prevalence of disability were found. However, in the same analyses for the individual activities of daily living, men had more disabilities than women for all the activities except bathing and incontinence control. In conclusion, women's higher prevalence of disability in the univariate and bivariate analyses were spurious, because it was disappeared when other related factors to disability were controled for and women's disability became lower than men for some activities of daily living.

Developing Measurement Items for the Service Quality of Clinical Trials based on the Brady & Cronin Model (Brady & Cronin의 모델에 기반한 임상시험 서비스 질 측정 문항 개발)

  • Go-Eun Lee;Sanghee Kim;Sue Kim;Sang Hui Chu;Jeong-Ho Seok;So Yoon Kim
    • The Journal of KAIRB
    • /
    • v.6 no.1
    • /
    • pp.17-31
    • /
    • 2024
  • Purpose: This study aims to develop preliminary items for measuring the perceived service quality of clinical trials among participants and to verify content validity. Methods: This study was designed as a methodological study. A conceptual framework was established based on Brady and Cronin's hierarchical model, and preliminary items were prepared through translation-back-translation, a review of existing instruments, and in-depth interviews with clinical trial participants and clinical research coordinators. The final items were completed through content validity testing by experts and a review of items by clinical trial participants for the prepared preliminary items. Results: Through this study, a set of 58 items across four domains (quality of interaction with researchers, the physical environment, performance procedures, and performance results) and 9 components (information·education·communication, trust, respect for participant preferences, securing facilities and space, accessibility, comfortability, informed consent, coordination of care, subjective understanding of clinical trials) on the service quality of clinical trials were completed. The scale content validity index of all preliminary items was 0.96, meeting the recommended standards. The individual-item content validity index also meets the recommended criteria for most items, excluding four items. Conclusion: This study holds significance in developing items to measure the quality of clinical trial execution from the perspective of participants. By verifying the reliability and validity of these items through subsequent research, it is expected that they can be utilized as a valuable instrument to devise strategies for improving the quality of clinical trials.

  • PDF

Verification of accuracy detection of the cows estrus using biometric information measuring device (생체정보 측정장치를 활용한 젖소 발정탐지의 정확도 검증)

  • Yang, Ka-Young;Woo, Sae-Mee;Kwon, Kyeong-Seok;Choi, Hee-Chul;Jeon, Jung-Hwan;Lee, Jun-Yeob
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.6
    • /
    • pp.652-657
    • /
    • 2018
  • Breeding control in a farm is a very important factor affecting milk productivity. Breeding management is important for the early detection of estrus, and reliable, automatic, more accurate, and faster monitoring of the timing of dairy cows is essential for farmers. This study measured the accuracy of estrus using the estrus indications, changes in activities, rumination activities, ruminal temperature, and pH. The biomedical information device S1 used in this study provided an estrus notice using the rumen temperature, pH, cow activities, and number of drinking estimations, which were inserted in the rumen through the oral route. The S2 device was used in the estrus notice for the rumen activities and cow activities. The data collected on the instrument were collected at intervals of 2 hours per day at the reference days (RD: -7~-3, +7~+ 3) +2), 7 days before insemination, and 7 days after insemination. The activities of the S1 device used in this paper increased with increasing number of insemination days (-1: $12.5{\pm}1.03/day$; 0: $12.9{\pm}1.73/day$) compared to the reference day (RD: $10.2{\pm}1.0/day$). The activities of the S2 device was also found to increase from the reference day to the insemination day (0: $63.0{\pm}3.66$) compared to the reference day (RD: $40.3{\pm}2.68$). The number of daily drinks in S1 decreased from the reference day (RD: $5.9{\pm}0.89/day$) to before the insemination day (-2: $5.6{\pm}0.98$; -1: $5.7{\pm}0.96$); +2: $6.0{\pm}0.73$). The number of daily drinks on the insemination day (0: $6.3{\pm}0.86$; +2: $6.0{\pm}0.73$) was similar to the reference day. The number of daily rumination in S2 decreased from the reference day (RD: $493.8{\pm}10.92$) to the insemination day (-1: $390.2{\pm}13.36$; 0: $354.1{\pm}16.71$).

Preliminary Study on the Standardization of Korean Version of Type D Personality Scale 14 : Internal Consistency and Construct Validity (D형 인격 척도의 표준화 예비연구 : 내적일치도 및 구성타당도)

  • Lee, Moon-Soo;Park, Young-Min;Lim, Hong-Euy;Song, Woo-Hyuk;Ahn, Jung-Chun;Kim, Seong-Hwan;Lee, Bun-Hee;Han, Chang-Su;Kim, Yong-Ku;Joe, Sook-Haeng;Ko, Young-Hoon
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.15 no.2
    • /
    • pp.81-87
    • /
    • 2007
  • Objectives : The distressed personality (type-D) pattern, consisting of negative affectivity and social inhibition, has been shown by Denollet et al. For measuring the Type D characteristics, Denollet has devised the 14 item Type D scale (DS14). In the present study, this instrument was translated into Korean. The reliability and validity of the Korean DS14 was pilot tested. Methods : Preliminary version of the total 17-item DS14 scale was translated into Korean. 372 controls that did not have any coronary heart diseases (CHD) were randomly sampled in Seoul and Gyeonggi province. Preliminary Korean version was applied to controls and 14 items were finally selected to maximize reliability of the scale. We compared the distribution of type-D personality among the normal controls, hypertensive patients, and the CHD patients. Results : 7 of 10 items in social inhibition were selected and final 14-item version was made. The internal consistency of negative affectivity (0.817) and social inhibition (0.797) were high. In addition, the prevalence of type-D personality in the CHD patients group was significantly higher than normal controls. Conclusion : These findings suggest that Korean version of DS14 is a valid tool for measuring the type D characteristics. Type-D characteristics can be suggested to predict adverse prognosis in patients with CHD.

  • PDF