• Title/Summary/Keyword: Measuring Instrument

Search Result 851, Processing Time 0.037 seconds

A Study on the Ground Surface Area Calculation of Golf Course using Triangulated Irregular Network (불규칙 삼각망을 이용한 골프장의 지표면적 산출에 관한 연구)

  • Kim, Sang-Seok;Chang, Yong-Ku;Kwak, Jae-Ha;Kim, Youn-Soo
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.4 no.4
    • /
    • pp.61-71
    • /
    • 2001
  • In these days, surveying instruments are developing rapidly and the precision is improving continuously. The reappearance of three dimensional terrains of a great precision are possible and the calculation of the area or the volume has a high precision due to the development of the technique of the spatial information system using computer. But actually, in construction site they calculate two-dimensional area using the traditional method, plane table surveying, planimeter, and then get ground surface area through timing the slope correction factor. In this study, I show the defect and inefficiency of the calculation of the area by the traditional methods and survey the area with Electronic Distance Measuring equipment and GPS instrument. With these data, we made the three dimensional terrain model and calculated two-dimensional area and ground surface area. After that, I compared areas that calculated by algorithm method of irregular triangle and analysis of grid method with standardizing the area that calculated by the traditional method. Finally, I suggested more effective and precise method in calculating ground surface area.

  • PDF

A Study on Image of the Nurse (간호사 이미지에 관한 연구)

  • Kim, Hyung-Ja;Kim, Hyeon-Ok
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.7 no.1
    • /
    • pp.97-110
    • /
    • 2001
  • An image exists in the thought of every subjective person and it exercises its influence over everything, having a great power in the real world. An positive image of the nurse has an influence on her faith, value and confidence, therefore increasing her job satisfaction, helping to upgrade her level of profession of nursing through qualitative nursing service as a result, considering the necessity of such an image when it comes to improvement of the profession, the confirmation of the image is indispensable to its evaluation of a speciality in nursing. This study is intended to help that improvement of the nursing profession in the present so that the total effort in every field of nursing is made and to offer basic material for developing a strategy to improve the image of nurses. This study is designed to investigate such an image descriptively. The subjects include 105 nurses, 60 doctors, 68 office workers, 88 medical engineers, 127 patients and there protectors with a total of 448 adapted with accidental sampling, who work at Y and W general hospital in Chonju. The measuring instrument consists of 40 question, with the researcher amended and made from on of Inja Song(1993), Donsoon Lee(1995), Ilsim yang(1998), and its Cronbach's alpha coefficient is .95. Data were collected from March 1 2000 to March 20, 2000 using self-reported questionnairs, analyzed with SPSS WIN 7.5 after encoding. The results are as follows: 1. Most of the subjects thinks the nursing as a hard, stressful, always busy job(more than 75%), and consider nurses as good-looking, supportive and responsible to co-workers to above average degree($50.0{\sim}74.9%$), especially it shows the idea that nursing is independently academic job and has come to fasten itself upon the public. But it shows below the everage($25.0%{\sim}49.9%$) in regard to self development as a specialist, affection for there job, an association activity, service to the community, high intelligence level and direct given patient nursing service. It also rated low as a recommendable job, independently nursing accomplishment, social position. 2. The nurses, patients and there protectors expressed more positive opinions than doctors, medical engineers, office workers about the image of the nurse(F=18.80, p=.00). This fact indicates that the former group evaluated the image similarly contrary to lowness of the latter. 3. In the study on what influenced upon the image, it defines to 79.8% by direct contact in the hospital or acquaintance with nurses, and 16.3% by mass media. 67.3% answered that they saw the image in a new light through hospitalization, which suggests an important source for the image management originates from caring for the quality of nursing service. Considering the evaluation of the image above, we need strategies to lead a unique professional knowledge and technological development, insurance of professional self-determination, high social position, participation in group activities, dedication to lifetime job, in order that nursing comes to expand as a professional occupation. Also, as for generating more positive images, we must take the quality of nursing service into account and offer and monitor correct information about the expanded role and function of the nurse continuously so that mass media reflect a more accurate image of nurses in general.

  • PDF

Change master cast by hardening method to position of tray after impression taking (인상채득 후 경화시 트레이의 위치에 따른 주모형의 변화)

  • Lee, Jung Ae
    • Journal of Korean society of Dental Hygiene
    • /
    • v.8 no.2
    • /
    • pp.53-66
    • /
    • 2008
  • There was to purpose of this study improves analyzing cause that prosthesis brings bite engaging that is inaccurate in patient's mouth, when supposed that all conducts that do in operatory and dental laboratory are perfect. Impression did check bite by alginate impression material and polymerization style silicon impression material that use usually in presence at a sickbed Irreversibility, hydrocolloid, alginate impression material washed in flowing water and poured anhydrite after wait about 8 minutes so that region that charge interest after impression check bite may become undoing. And hydrophile property addition polymerization style impression material poured anhydrite after blow 30 considering impression material dwell time and H2 gas occurrence time (5~15 minute) after have washed in flowing water. I got each 7 models, result that manufactures total 28 and measures by third dimension measuring instrument (Meteo, Korea) following sequence curing in tray holder and floor 1, By Alginate impression when is hardened in tray holder and when is hardened in the floor after do check bite, SPH 4, SPH5 all as there is synonymy appeared(P<0.05). By in case do not use average 0.1741 in case use tray holder in 0.0447 SPH5s in case do not use average 0.2838 pastas in case use tray holder in SPH4 0.0309, When did not use both SPH4 and SPH5 tray holder, when used tray holder, 1 appeared more greatly. 2. By amity sex addition polymerization style silicon impression when is hardened in tray holder after do check bite and when is hardened in the floor SPH 4, a11 of the SPH5s very big synonymy be(P>0.05). And in case use tray holder in 0.000657 pasta SPH5s in case do not use average 0.000129 pastas in case use tray holder in SPH4 average 0.000114 pastas, by in case do not use 0.000757, I appeared more greatly when used tray when did not use both SPH4 and SPH5 tray holder, but 1 appeared is not level to keep in mind(Table 8~9). 3 SPH4 was looked very big mindfulness in model that manufacture doing impression check bite by Alginate and model that do impression check bite by amity sex accessory penalty silicon without using tray holder(P< 0.001). I use tray holder and SPH4 did not appear synonymy in model that manufacture doing impression check bite by Alginate and model that do impression check bite by amity sex accessory penalty silicon(P>0.05). Study finding of above when see synthesis Alginate certainly tray holder use must and I could know that hardening method does not exert big influence on volume stability if remove impression sieve of excess because amity sex accessory penalty silicon passes over tray, Also, Alginate impression material previewed can get heading a conspiracy style that volume stability of accessory penalty silicon impression material degree is if use tray holder.

  • PDF

Study on Developing Instrument System for Measuring Action time of K4 Grenade Machine Gun for Improving Quality Assurance on 40mm High Velocity Grenade (40mm 고속유탄의 품질보증 향상을 위한 K4 기관총의 Action Time 계측시스템 개발에 관한 연구)

  • Hong, Sung-Kook;Shin, Jun-Goo;Jeon, Hye-Jin;Kim, Yong-Hwa;Ju, Jin-Chun;Kwon, In-Gyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.7
    • /
    • pp.4828-4834
    • /
    • 2015
  • From the moment that a firing pin triggers the detonator to the moment that a grenade leaves a barrel is called Action Time. Since a loading and percussion of 40mm grenade happens simultaneously, action time should be within a certain time in order to prevent a Jamming malfunction. Previously, unreliable action time device of 40mm grenade made it difficult to improve quality assurance of K4 Grenade Machine Gun. Here, various sensors were compared and a special device was designed to seek an accurate measurement on action time. In this device, the gap between a signal from an optical sensor in Firing Pin and that from Eddy current probe in the barrel was recorded and data were sent to a computer in real time. Confirming if action time is within the criteria, it is expected that action time plays an important role in quality assurance on 40mm grenade.

A Comparison of the Amount of Fluoride Ion Released and Remineralization Effect on the Initial Caries Lesion of the Various Fluoride Varnishes (시판중인 불소 바니쉬의 불소이온 유리량 및 초기우식병소의 재광화 효과 비교)

  • Lee, Kayoung;Lee, Sangho;Lee, Nanyoung;Jih, Myeongkwan
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.43 no.4
    • /
    • pp.443-451
    • /
    • 2016
  • Subjects of this study were : $FluoroDose^{(R)}$ (FD, Centrix Inc., USA), $Enamelast^{TM}$ (EL, Ultradent Product Inc., USA), $Clinpro^{TM}$ white varnish (CW, 3M ESPE, USA), $CavityShield^{TM}$ (CS, 3M ESPE, USA), V $varnish^{TM}$ (VV, Vericom, Korea), MI $varnish^{TM}$ (MI, GC, Japan). The amount of fluoride ion release was measured eight times during 168 hours to see change in accumulation with the course of time using a measuring instrument. And the remineralization rate was measured with Quantitative Light-induced Fluorescence (QLF). V $varnish^{TM}$ group and MI $varnish^{TM}$ group showed high remineralization rates with statistically significance while $CavityShield^{TM}$ group was the lowest rate of remineralization (p < 0.05). After that, several chosen samples were scanned through electron microscope (SEM). Demineralized enamel was observed as the number of enamel crystal was very small; enamel rods and crystals were highly protruding. Remineralized groups with fluoride varnishes show the decreasing tendency of the surface roughness compared to the demineralized enamel.

Determination of Gross-${\beta}$ and ${\gamma}$-Ray Activity Concentrations of Human Tooth (치아의 전베타 농도 및 감마선 방사능 평가)

  • Jeong, Hyunja;Kang, Hyun-Kyung;Kim, Sunghwan
    • Journal of radiological science and technology
    • /
    • v.37 no.4
    • /
    • pp.261-265
    • /
    • 2014
  • The ${\gamma}$-ray concentration and gross-${\beta}$ activity by age group were measured in the teeth of males and females of the domestic residents. They were divided into 7 age groups from 10s to the age of 70s. The gross-${\beta}$ activity concentration was measured by using the Tennelec XLB measuring instrument filled with P10 gas (argon 90%, methane 10%). The ${\gamma}$-ray was measured through the ${\gamma}$-ray spectroscopic analytical method by using the high purity germanium (HPGe) radiation detector. The range of gross-${\beta}$ activity concentration was measured 0.089 to 0.32 Bq/kg in females and 0.13 to 0.26 Bq/kg in males. From the ${\gamma}$-ray spectroscopic analysis of the teeth, the natural radioactive isotopes of $^{40}K$, $^{208}Tl$, $^{228}Ac$ and $^{234}Th$ were detected and their measured ${\gamma}$-ray activity concentrations were found to be 20.7, 21.9, 3.88 and 5.24 Bq/kg, respectively.

Development of a Measuring Instrument for the Coefficient of Luminous Intensity of Retro-Reflection of Miniature Telecentric Cameras (소형 텔레센트릭 카메라 광학계의 재귀반사 측정 방법 연구 및 측정 장치 개발)

  • Yeo, TaeWoon;Karasik, V.E.;Kim, Young Il
    • Korean Journal of Optics and Photonics
    • /
    • v.25 no.6
    • /
    • pp.334-339
    • /
    • 2014
  • In this paper, the optical properties of a miniature telecentric camera are studied analytically and experimentally. By means of optical properties, the luminous intensity of retro-reflection of a miniature telecentric optical system is investigated. First, from a simulation the theoretical value of the coefficient of luminous intensity of retro-reflection of a miniature telecentric system is estimated. Second, a miniature telecentric camera device is designed, and the value of the coefficient of luminous intensity of retro-reflection of the actual device is measured through experiment. From simulation and experiment, we found that both the estimated and observed values of the coefficient of luminous intensity of retro-reflection range from 0.002 to $0.03m^2/sr$ (P384200CPH: $0.0042-0.018m^2/sr$, P285200CPH: $0.0045-0.0297m^2/sr$, P321450S: $0.0021-0.00963m^2/sr$) at 1.4 to 4.9 arcminute. The results prove the significance of the mechanisms used to design the miniature telecentric camera, and the experimental method. Accordingly, with these significant results, this study contributes to the development of theory and practice in optical engineering science.

Shaping Ability of Four Rotary Nickel-Titanium Instruments to Prepare Root Canal at Danger Zone (네 가지 전동 Ni-Ti 파일의 danger zone에서의 근관성형력)

  • Choi, Seok-Dong;Jin, Myoung-Uk;Kim, Ki-Ok;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.5
    • /
    • pp.446-453
    • /
    • 2004
  • The aim of this study was to evaluate the shaping abilities of four different rotary nickel-titanium instruments with anticurvature motion to prepare root canal at danger zone by measuring the change of dentin thickness in order to have techniques of safe preparation of canals with nickel-titanium files. Mesiobuccal and mesiolingual canals of forty mesial roots of extracted human lower molars were instrumented using the crown-down technique with ProFile, $GT^{TM}$ Rotary file, Quantec file and $ProTaper^{TM}$. In each root, one canal was prepared with a straight up-and-down motion and the other canal was with an anticurvature motion. Canals were instrumented until apical foramens were up to size of 30 by one operator. The muffle system was used to evaluate the root canal preparation. After superimposing the pre- and post-instrumentation canal. change in root dentin thickness was measured at the inner and outer sides of the canal at 1. 3, and 5 mm levels from the furcation. Data were analyzed using two-way ANOVA. Root dentin thickness at danger zone was significantly thinner than that at safe zone at all levels (p < 0.05). There was no significant difference in the change of root dentin thickness between the straight up-and-down and the anticurvature motions at both danger and safe zones in all groups (p > 0.05). ProTaper removed significantly more dentin than other files especially at furcal 3 mm level of danger and safe zones (p < 0.05) Therefore, it was concluded that anticurvature motion with nickel-titanium rotary instruments does not seem to be effective in danger zone of lower molars.

Performance Appraisal and Job Rotation of the Nurse In a General Hospital (간호사 인사관리 제도에 관한 연구)

  • Kwon, Young-Hee;Lee, Myung-Ha
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.5 no.3
    • /
    • pp.425-444
    • /
    • 1999
  • The purpose of this study is to survey evaluation of the nurse on the current Performance Appraisal System. the need for future performance of the nurse and the opinions about the job rotation, and suggest the direction of improvement by obtaining basic data to improve personnel management of the nurse in a hosipial, the subject of the investigation. The study was conducted self-reporting questionniare survey of 330 nurses working at C hospital located in Chonbuk Province and the data was collected from May 4. 1999 through May 14. The research used measuring instrument developed by researcher for evalution about the present performance appraisal. the need for the future performanc appraisal system and the opinion of job rotaion. The analysis of the collected data was computerized using SPSS/PC+ program, calculated frequency, percentage, the mean and standard deviation and used Pearson, s Correlation Coefficients, t-test, chi- square test. Major findings are as follows. 1) As for the purpose of the current performanc appraisal, the appraiser recognized it as a security of promotion standard, while the employee saw it as a means for control as guidance and supervison of work. 2) With regard to use the result of the present performance appraisal, appraiser picked ambiguous appraisal standard, employees recognized unilateral evaluation of superior eliminated the participation of them as the highest priority. 3) In relation to the current criteria for promotion of the nurse, both appraisers and employees placed more weight on the length of clinical than performance appraisal score. 4) There is much possibility of the appraiser making an error to evaluate considering the length of performance appraisal. 5) Both appraisers and employees indicated that prospective result of performance appraisal should be used for the ability development & motivation of the individual. 6) Concerning employee's participation for performance appraisal both sides wanted by far more participation. 7) Regarding the most ideal appraisal method, both parties favored most the way added up the evaluation of the head nurse and peer review and followed by the manner the revaluation of the head nurse by considering self-evaluation. 8) As to the individual interview after the appraisal, more than 60% of appraisers responded it's not necessary, while above 88.5% of employees answered it is essential so that it is showed significantly difference between the appraisers and the employees. 9) As far as open of the evaluation result is concerned. 75% of the appraiser were against it but 80% of the employee were for it so that it showed significantly between them. The most principal reason that the employee want is that it motivates the individual's ability development and the fairness of the appraisal increases. 10) Whether the periodical rotation is necessary or not, 80% of appraisers and employees answered it's necessary, however, over 70% of them did not want the rotation. 11) Work-group Cohesiveness level within the nursing unit was attentive different from desire of the rotation, that is, the work group cohesiveness level of nurses wanting rotation was significantly lower than that of the group not desiring it.

  • PDF

Relationship between Health-Related Physical Fitness, Cognitive Function and Isolation in the Elderly (노인의 건강관련체력과 인지기능 및 고립감의 관계)

  • Lee, Kyung-Ha;Choi, Jae-won;Lee, Na-Eun;Kang, Sung-Goo;Jung, Hye-Yeon;Chun, Myung-Up;Yoo, Ha-Na;Park, Ji-Su;Park, Jung-Soo
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.4
    • /
    • pp.285-301
    • /
    • 2018
  • The purpose of this study was to investigate the relationship between health-related physical fitness factors and cognitive function and isolation on 308 elderly over 65 years old in Seoul and Gyeonggi do. The measuring instrument were as follows demographic characteristics(age, education level, drink, spouse, participation on in exercise) and health-related physical fitness(grip strength, leg strength, flexibility, balance), cognitive function (MMSE-K, digit span test) and emotional/social aspects of loneliness and isolation was measured. As a results, first, depending on the degree of demographic characteristics of elderly had significant difference. Second, health-related physical fitness and cognitive function are positive correlated, negative correlation between cognitive function and isolation. Third, health-related physical fitness of the elderly had a significant effect on cognitive function. Fourth, health-related fitness of the elderly had a significant effect on isolation. Fifth, the cognitive function of the elderly had a significant effect on isolation. In conclusion, this study will provide basic data for future aged man welfare studies and contribute to extended studies.