• Title/Summary/Keyword: Measuring Device

Search Result 1,517, Processing Time 0.038 seconds

A Study on the Measurement of the Beam Pattern of Array Antenna for VHF Radar using Active Beam Pattern Measuring Device and Drone (능동 빔패턴 측정장치 및 드론을 활용한 초단파레이다용 배열안테나의 빔패턴 측정에 대한 연구)

  • Kim, Ki-Jung;Lee, Sung-Je;Jang, Youn-Hui
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.6
    • /
    • pp.1031-1036
    • /
    • 2019
  • This study describes the technique of the beam pattern measurement of array antenna for VHF band radar using drone and active beam pattern measuring device. There is no anechoic chamber for measuring the beam pattern of a large size antenna in the country. In this study, to test the antenna beam pattern characteristics of the developed VHF band radar, the antenna beam pattern characteristics were tested by Drone mounting an Active Beam Pattern Measuring Device. By comparing the results of the pre-simulation analysis with the measured results for the antenna, we could confirm that the beamwidth and side-lobe characteristics are satisfactory. Through the antenna beam pattern measurement technology using Drone and Active Beam Pattern Measuring Device, the beam pattern measurement technology of array antenna of low frequency band and large antenna for low band radar will be used.

디지탈 화상처리를 이용한 사출제품의 길이측정용 시각검사시스템 개발에 관한 연구

  • 김재열;박환규;오보석
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.04a
    • /
    • pp.281-285
    • /
    • 1996
  • In this paper, I made visual inspection system using Vision Board and it is consist of an illuminator (a fluorescent lamp), image input device(CCD(Charge)Coupled Device) camera), image processing system(Vision Board(FARAMVB-02), image output device(videomonitor, printer), a measuring instrument(TELMN1000). Length measurement by visual inspection system is used 100mm gauge block instead of calculating distance between camera and object, it measured horizontal and vertical length factor from 400mm to 650mm by increasing 50mm. In this place, measured horizontal and vertical length factor made use of length measurement of a injection. A measuring instrument used to compare a measured length of a injection visual inspection system with it. In conclusion, length measurement of a injection compared a measuring instrument withvisual inspecion system using length factor of 100mm guage block. Maximum error of length compared two devices a measuring instrument with visual inspection system is 0.55mm. And operation program is made up Borland C++ 3.1. By changing, it is applied to various uses.

  • PDF

A Study on the Measurement of Circularity and Perpendicularity Using Circular Test Method (CT법을 이용한 진원도 및 직각도 측정에 관한 연구)

  • 주만식
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2000.04a
    • /
    • pp.75-81
    • /
    • 2000
  • This study for the roundness and perpendicularity of machining center is classified into two ways. One is the way that progresses the roundness amending the parameter of machining center based on the measured value after the measurement of the roundness of machaning center by means of a existing measuring device, another is the way that measures the roundness by remodeling the existing measuring device. the former is studied by pack hei jae team in Seoul university, the later is studied by TSUTSUMI. Especially TSUTSUMI measures the roundness according to circular compensation after the insertion of developed measuring device using a rotary encoder to the spindle of machining tool. we study how regulation velocity occuring with circular motion of machining center table influences the roundness after measuring the roundness using Circular Test method by a 2 dimention probe and a standard discus in this experiment.

  • PDF

Design and Assembling of Load and Strain Measuring Equipment using Strain Gage and A/D Converter (Strain Gaged와 A/D 변환기를 이용한 하중, 변형률 측정장치 제작)

  • Park T.G.;Yang M.B.;Baek T.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.293-294
    • /
    • 2006
  • The conventional strain measuring device is costly and complicated - it is not simple to understand its structure. Hence, strain gage and the A/D converter are assembled to come up with a load and a strain measuring device. The device was tested for measuring the strain in a loaded specimen and the experimental results were compared to those obtained by a commercial strain indicator.

  • PDF

Calibration off multiple-sensor measuring system for efficient visual inspection (형상 검사를 위한 multiple-sensor 측정 시스템의 캘리브레이션 연구)

  • 김승만;손석배;이관행
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.579-582
    • /
    • 2002
  • In acquiring the surface information of a part, two types of measuring machines have been used: contact type and non-contact type. Since each measuring device has the pres and cons, an integrated measuring system is proposed to acquire the optimal point data. In order to implement the integrated measuring system, the relationship of coordinate systems between each measuring device should be established. In this paper, a new datum fixture and a calibration method for the multiple-sensor measuring system are proposed. The datum fixture is designed to interface two machines, a CMM and a laser scanner. The position of the datum fixture is calibrated by the axis information off motorized rotation stage which is used for a part setup.

  • PDF

A Study on the Automatic Measurement of Salt Contamination (염분 오손 자동측정에 관한 연구)

  • Kwak, Hee-Ro;Kim, Han-Sang;Kweon, Dong-Jin;Lee, Dong-Zoon;Kim, Kyoung-Wha;Cho, Kug-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1362-1364
    • /
    • 1995
  • In this paper, the automatic device for measuring the salt contamination on insulators was developed. The device consists of electronic insulators, measuring system, monitoring system, and printer. It was shown that the level of salt contamination measured by the developed device is similar to that measured by the brush cleaning method. Therefore, the developed automatic measuring device can be used in field, in order to predict the cleaning time of insulators and prevent the failure due to the salt contamination.

  • PDF

Development of Weight Sensing Unit of Fruit Weight Grader Using Load Cell (중량선과기(重量選果機)의 중량감지부(重量感知部) 개선(改善)에 관(關)한 연구(硏究))

  • Kim, H.S.;Koh, H.K.
    • Journal of Biosystems Engineering
    • /
    • v.18 no.4
    • /
    • pp.358-370
    • /
    • 1993
  • In Korea, fruit grading has been mainly done manually, and manual grading depends on human sense. Thus it is subjected to human error and is not always as consistent as would be desired. Therefore, a study on the development of fruit grader was initiated to improve the consistency of fruit grading. The sensitivity for fruit weight of the conventional spring type weight grader has a tendency to decrease by physical characteristics of spring which is used as a weight sensing unit. This study was carried out to develop weight measuring device for establishing the base of weight sensing unit of electronic weight grader. This device consists of a weight sensor using load cell, data acquisition system, and a microcomputer containing program to calculate fruit weight. The weight measuring device using load cell was developed to increase sensitivity of fruit weight. The result of this study showed that the weight sensing unit of electronic weight grader contributed to the improvement of performance of weight measuring device.

  • PDF

Height Measurement of Cellphone Curved Glass using Camera (카메라를 이용한 휴대폰 곡면유리의 높이측정)

  • Kim, Han-Sol;Lee, Kyung-Jun;Jung, Dong-Yean;Lee, Yeon-Hyeong;Kim, Gab-Soon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.12
    • /
    • pp.1002-1010
    • /
    • 2016
  • This paper describes the design of a cellphone curved glass measuring device using by camera. The measuring device was composed of two camera, two backlight system, a body and so on, and the program was made for a camera calibration and noise removal, and also the program was made for height measurement of a cellphone curved glass using by subpixel algorism. And then a new technique for measuring the height of the cell phone curved glass was proposed. The characteristics test of height measurement of gage blocks and cell phone curved glasses was carried out, the error of the height measurement of gage block is less than ${\pm}0.005$ and the error of the height measurement of the cell phone curved glasses is less than ${\pm}0.005$. Thus it thought that the designed cellphone curved glass measuring device and the new technique for measuring the height was used to measure the height of the cellphone curved glass.

Development of a measuring device for scale accuracy of measuring tapes (줄자눈금정밀도 측정장치 개발에 관한 연구)

  • 이종원;김희식;유형석
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1988.10a
    • /
    • pp.380-384
    • /
    • 1988
  • An optical device, named "T-MES", to measure the accuracy of printed scale of measuring tapes was developed. It has 11 optical sensors, that are exactly positioned every 100 mm on the 1 m frame. The sensors detect the beginning of the printed part and generate the puleses. The time difference between each signal pulse and the first sensor signal pulse is proportional to the error of printed scale. The measured data are trasmitted through a IEEE-488 interface to a IBM-AT computer and analyzed. The analysis software continuously displays the measured result on the CRT.n the CRT.

  • PDF

Development of the Measuring Device of Muzzle Velocity using Magnetic Field Gradient Sensor (자계 차분형 센서를 이용한 초소형/고정밀 탄속 측정장치 개발)

  • 채제욱;김종천;최의중;이영신
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.6 no.4
    • /
    • pp.22-28
    • /
    • 2003
  • In the conventional weapon system, such as gun and small arms, it Is a general trend that for maximization of its performance and enhancement of its effectiveness, the firing control system(FCS) is developed and applied with the guns and small arms in the world. The FCS of the small arms for infantry man is composed of a few of sensors for acquisition of input data of FCS, such as range measurement, position sensing of weapon, temperature, etc., computer, displayer and power pack, and also the air burst munition is developed in parallel for the maximization of FCS's effectiveness. Since the flight time setting fuze for the air burst munition is adapted for next me, the measuring device of the muzzle velocity is needed to overcome the variation of muzzle velocity due to producing procedures and the differences of the using temperatures and so maintain the burst position accuracy This paper contained the technical information on the development of the measuring device of muzzle velocity, which designed in compact & light weight configuration with reliability and accuracy.