• 제목/요약/키워드: Measuring/Monitoring

검색결과 1,270건 처리시간 0.029초

학령기 아동의 자기보호와 부모감독에 따른 또래관계 및 인지적 자기능력 지각 (The Effects of Self-care and Parental Monitoring on Peer Relations and Perceived Cognitive Self-Competence of School Age Children)

  • 천희영;옥경희;김미해
    • 대한가정학회지
    • /
    • 제39권10호
    • /
    • pp.153-168
    • /
    • 2001
  • The objects of this study were to find out the effects of peer relations and perceived cognitive self-competence according to 1) grade, sex, and self-care, 2) parental social status and monitoring. 429 3rd- and 6th-graders (238 boys and 191 girls) were included as subjects. For measuring variables, RCP, Harter's Perceived Cognitive Self-Competence Rating Scale, and Parental Monitoring Questionnaire based on Crouter et al.(1990) were used. The data were analysed by MANOVA, t-test, and univariate ANOVA. The results were as follows.‘Social-Leadership’of peer relations was influenced by children's grade, grade $\times$ sex effects. 3-way interaction of children's variables and parental monitoring made significant differences in ‘Shy-Isolation’. Children's perceived cognitive self-competence was influenced by their grade and parent's social status. These results confirmed the significant roles of self-care and parental monitoring in children's development.

  • PDF

인터넷을 이용한 실시간 해양항만 환경모니터링 시스템의 설계 (A Real Time, Internet Accessed, Monitoring System of the Ocean and Harbor Environment)

  • 서규우;김가야
    • 한국해양공학회지
    • /
    • 제18권1호
    • /
    • pp.10-15
    • /
    • 2004
  • For effective conservation of the oceans and harbors, long-term and systematic development of the ocean and harbor monitoring system is essential. A monitoring system capable of real-time and accurate data acquisition is necessary for dealing with the level of contamination by situations, such as red tide and foods. This paper introduces an effective and economical real-time harbor environmental monitoring system that utilizes PCS wireless data communication technology. The monitoring system has various functions, such as multiple communication, TCP/IP protocol for wireless internet access, system time synchronization, and bi-directional communication between the measuring device and the server. The system has been implemented at Shinseondae harbor pier in Busan to validate the system's stability and effectiveness in data acquisition. The acquired real-time ocean and harbor environmental data is expected to have a large effect, when shared with the public through the Internet.

Implementation of Medical Device Integration Module for Integrated Patient Monitoring System

  • Park, Myeong-Chul;Jung, Hyon-Chel;Choi, Duk-Kyu
    • 한국컴퓨터정보학회논문지
    • /
    • 제22권6호
    • /
    • pp.79-86
    • /
    • 2017
  • In this paper, we implement a common module that can integrate multiple biometric information for integrated patient monitoring system. Conventional biomedical instruments have many devices attached to each patient, making it difficult to monitor abnormality signs of many patients in real time. In this paper, we propose a module for an integrated monitoring system that can perform centralized monitoring using a common module that integrates multiple measurement devices. A protocol for sending and receiving packets between the measuring device and the common module is designed, and the packets transmitted through the network are stored and managed through the integrated monitoring system and provide information to various users such as medical staff. The results of this study are expected to contribute to the management of patients and efficient medical services in hospitals.

인터넷을 이용한 실시간 해양항만 환경모니터링 시스템의 설계 (Design of Real Time Monitoring System of Ocean & Harbor Environment Using by Internet)

  • 서규우
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.63-68
    • /
    • 2003
  • For effective conservation of ocean and harbor, long-term and systematic development of the ocean and harbor monitoring system is essential. The monitoring system capable of real-time and accurate data acquisition is necessary for dealing with contamination such as red tide and the flood. This paper introduces the effective and economical real-time harbor environmental monitoring system that utilizes PCS wireless data communication technology. The monitoring system has various functions such as multiple communication, TCP/IP protocol for wireless internet access, system time synchronization, bi-directional communication between the measuring device and the server. The system has been implemented at Shinseondae harbor pier in Busan to validate the systems stability and effectiveness in data acquisition. The acquired real-time ocean and harbor environmental data is expected to have a large effect, when shared by public through internet.

  • PDF

스마트시티 IoT플랫폼 구축을 위한 자율사물 모니터링 시스템 적용성 평가 (Application on Autonomous Things Monitoring System for IoT Platform of Smart City)

  • 유찬호;백승철
    • 토지주택연구
    • /
    • 제11권1호
    • /
    • pp.103-108
    • /
    • 2020
  • Autonomous things system is a technology that judges and acts based on using surrounding information by itself, and it is evaluated as a future technology that can replace the current IoT technology. The current IoT technology is widely used from facility monitoring to machine control but it is shown weakness as a evaluation and prediction technique despite of smart city important technology. In this study, in order to confirm the application of the autonomous things technology, a monitoring system was installed on a real reservoir dam facility and long-term monitoring was performed that the measuring device itself judges and control as a facility monitoring technology. The autonomous things technology was confirmed during 19 months and it is possible to continuous measurement in the same way as current automated instrumentation. In addition, it was confirmed that the ICT device itself could to control autonomously measurement cycle according to the rainfall by itself.

A Design of Condition Monitoring System for Predictive Maintenance

  • Jeong, Hai-Sung;Kim, Heung H.;Sang K. Yun;Elsayed A. Elsayed
    • International Journal of Reliability and Applications
    • /
    • 제2권1호
    • /
    • pp.57-71
    • /
    • 2001
  • Global competition to increase production output and to improve quality is spurring manufacturing companies to use condition monitoring and fault diagnostic systems for predictive maintenance. As monitoring, testing, and measuring techniques develop, predictive control of components and complete systems have become more practical and affordable. In this article, we will consider the computer based data acquisition system for condition monitoring and the condition parameter analysis techniques for fault detection and diagnostics in the machinery and briefly discuss reliability prediction and the limit value determination in condition monitoring.

  • PDF

W-Station을 활용한 고밀도 초미세먼지 모니터링 연구: 제주도 사례 (A study on the monitoring of high-density fine particulate matters using W-station: Case of Jeju island)

  • 이종원;박문수;원완식;손석우
    • 한국입자에어로졸학회지
    • /
    • 제16권2호
    • /
    • pp.31-47
    • /
    • 2020
  • Although interest in air quality has increased due to the frequent occurrence of high-concentration fine particulate matter recently, the official fine particulate matter measuring network has failed to provide spatial detailed air quality information. This is because current measurement equipment has a high cost of installation and maintenance, which limits the composition of the measuring network at high resolution. To compensate for the limitations of the current official measuring network, this study constructed a spatial high density measuring network using the fine particulate matter simple measuring device developed by Observer, W-Station. W-Station installed 48 units on Jeju Island and measured PM2.5 for six months. The data collected in W-Station were corrected by applying the first regression equation for each section, and these measurements were compared and analyzed based on the official measurements installed in Jeju Island. As a result, the time series of PM2.5 concentrations measured in W-Station showed concentration characteristics similar to those of the environmental pollution measuring network. In particular, the results of comparing the measurements of W-Station within a 2 km radius of the reference station and the reference station showed that the coefficient of determination (R2) was 0.79, 0.81, 0.67, respectively. In addition, for W-Station within a 1 km radius, the coefficient of determination was 0.85, 0.82, 0.68, respectively, showing slightly higher correlation. In addition, the local concentration deviation of some regions could be confirmed through 48 high density measuring networks. These results show that if a network of measurements is constructed with adequate spatial distribution using a number of simple meters with a certain degree of proven performance, the measurements are effective in monitoring local air quality and can be fully utilized to supplement or replace formal measurements.

Leak Evaluation for Power Plant Valve Using Multi-Measuring Method

  • Lee, Sang-Guk;Park, Jong-Hyuck;Kim, Young-Bum
    • 비파괴검사학회지
    • /
    • 제28권6호
    • /
    • pp.469-476
    • /
    • 2008
  • Condition based maintenance(CBM) for the preventive diagnosis of important equipments related to safety or accident in power plant is essential by using the suitable methods based on actual power plant conditions. To improve the reliability and accuracy of the measured value at the minute leak situation, and also to monitor continuously internal leak condition of power plant valve, the development of a diagnosis and monitoring technique using multi-measuring method should be performed urgently. This study was conducted to estimate the feasibility of multi-measuring method using three different methods such as acoustic emission(AE) method, thermal image measurement and temperature difference$({\Delta}T)$ measurement that are applicable to internal leak diagnosis for the power plant valve. From the experimental results, it was suggested that the multi-measuring method could be an effective way to precisely diagnose and evaluate internal leak situation of valve.

TLS 변위계측모델을 이용한 장스팬 철골 박스형 거더의 변위 계측 (Displacement Measurement of an Existing Long Span Steel Box-Girder using TLS(Terrestrial Laser Scanning) Displacement measurement Model)

  • 이홍민;박효선;이임평;권윤한
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2007년도 정기총회 및 학술발표대회
    • /
    • pp.53-56
    • /
    • 2007
  • It was previously introduced a new displacement measuring technique using terrestrial laser scanning (TLS) that remotely samples the surface of an object using laser pulses and generates the three-dimensional (3D) coordinates of numerous points on the surface. In this paper, for an assessment of the capabilities of the measuring technique about existing structures, the field tests for vertical displacement measurement of an existing long span steel box-girder are experimentally carried out. The performance of the technique is evaluated by comparing the displacements obtained from TLS system and displacements directly measured from linear variable displacement transducer (LVDT).

  • PDF

Automated measurement of tool wear using an image processing system

  • Sawai, Nobushige;Song, Joonyeob;Park, Hwayoung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1995년도 Proceedings of the Korea Automation Control Conference, 10th (KACC); Seoul, Korea; 23-25 Oct. 1995
    • /
    • pp.311-314
    • /
    • 1995
  • This paper presents a method for measuring tool wear parameters based on two dimensional image information. The tool wear images were obtained from an ITV camera with magnifying and lighting devices, and were analyzed using image processing techniques such as thresholding, noise filtering and boundary tracing. Thresholding was used to transform the captured gray scale image into a binary image for rapid sequential image processing. The threshold level was determined using a novel technique in which the brightness histograms of two concentric windows containing the tool wear image were compared. The use of noise filtering and boundary tracing to reduce the measuring errors was explored. Performance tests of the measurement precision and processing speed revealed that the direct method was highly effective in intermittent tool wear monitoring.

  • PDF