• 제목/요약/키워드: Measurement validation

검색결과 700건 처리시간 0.028초

고속전철 천안역사 내부의 풍압연구 (A Study on Wind Pressure inside Cheonan High Speed Train Station)

  • 원찬식;김사량;허남건
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.843-846
    • /
    • 2002
  • Unlike ordinary train, the HST(High Speed Train) is operated at a very high speed, which may cause pressure transient problems when the HST is passing through a station. In the present study, the wind pressure caused by the passing HST was measured in the Cheonan HST station and compared with the numerical simulations. For the measurement, the HST was passing through the station at speeds of 240 km/h north bound and 150 km/h south bound. MEMS based differential pressure transducers are used to measure pressure variation at various locations in the station. It is shown from the results that measured data are in good agreement with CFD simulation with moving mesh technique for the train movement. With the present validation of CFD simulation, the CFD simulation may effectively aid the design of future HST station.

  • PDF

Investigation on the Flow Field Characteristics of a Highly Underexpanded Pulsed Plasma Jet

  • Kim, Jong-Uk;Kim, Youn J.
    • Journal of Mechanical Science and Technology
    • /
    • 제15권12호
    • /
    • pp.1691-1698
    • /
    • 2001
  • In recent years, significant progress has been made in modeling turbulence behavior in plasma and its effect on transport. It has also been made in diagnostics for turbulence measurement; however, there is still a large gap between theoretical model and experimental measurements. Visualization of turbulence can improve the connection to theory and validation of the theoretical model. One method to visualize the flow structures in plasma is a laser Schlieren imaging technique. We have recently applied this technique and investigated the characteristics of a highly underexpanded pulsed plasma jet originating from an electrothermal capillary source. Measurements include temporally resolved laser Schlieren imaging of a precursor blast wave. Analysis on the trajectory of the precursor blast wave shows that it does not follow the scaling expected for a strong shock resulting from the instantaneous deposition of energy at a point. However, the shock velocity does scale as the square root of the deposited energy, in accordance with the point deposition approximation.

  • PDF

BLDC 모터를 적용한 로터리 컴프레서 소음 저감에 관한 연구 (Study on the Noise Reduction in the Rotary Compressor using BLDC Motor)

  • 김진수;임경내;구세진;이장우;전시문
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.674-681
    • /
    • 2008
  • The main noise source of the BLDC rotary compressor for air conditioner was analyzed by using the measurement of noise and vibration, noise contour, and experimental modal analysis. The source is presumed to the mechanical resonance excited by the electromagnetic attractive force of the BLDC motor. To reduce the excessive noise of the BLDC rotary compressor due to the mechanical resonance, air-gap was enlarged. Its validation was conducted by the analysis of the electromagnetic attractive force which is generated by the BLDC motor. By enlarging the length of air-gap, the noise in the compressor and air conditioner was significantly improved by 2.5dB(A) and 4.5dB(A), respectively.

  • PDF

INSTRUMENTATION AND CONTROL STRATEGIES FOR AN INTEGRAL PRESSURIZED WATER REACTOR

  • UPADHYAYA, BELLE R.;LISH, MATTHEW R.;HINES, J. WESLEY;TARVER, RYAN A.
    • Nuclear Engineering and Technology
    • /
    • 제47권2호
    • /
    • pp.148-156
    • /
    • 2015
  • Several vendors have recently been actively pursuing the development of integral pressurized water reactors (iPWRs) that range in power levels from small to large reactors. Integral reactors have the features of minimum vessel penetrations, passive heat removal after reactor shutdown, and modular construction that allow fast plant integration and a secure fuel cycle. The features of an integral reactor limit the options for placing control and safety system instruments. The development of instrumentation and control (I&C) strategies for a large 1,000 MWe iPWR is described. Reactor system modeling-which includes reactor core dynamics, primary heat exchanger, and the steam flashing drum-is an important part of I&C development and validation, and thereby consolidates the overall implementation for a large iPWR. The results of simulation models, control development, and instrumentation features illustrate the systematic approach that is applicable to integral light water reactors.

유치원 유아의 모-자간 애착유형분류와 애착에 대한 유아기질의 영향 (Classifications of Attachment to Mother at Age 5 and 6 and the Relationship between Temperament and Attachment)

  • 홍계옥
    • 아동학회지
    • /
    • 제14권2호
    • /
    • pp.5-16
    • /
    • 1993
  • The purpose of the present study was to classify the attachment to mothers of kindergarten children based on a system for classifying attachment organization developed by Main and Cassidy(1988) and to examine the relationship of children's temperament with attachment. 32 children and their mothers were observed and videotaped in the strange situation. Mothers were administered the children's temperament questionnaire revised by Chun (1992). The data were analysed by t-test. The results showed similarity between the attachment classifications of Main and Cassidy (1988) and those of Korean children. These results can be considered partial validation of Main and Cassidy's classification system for the measurement of the attachment of 5-to 6-year-old Korean children. Children's temperament has significant correlation to the security of attachment.

  • PDF

인간 청각 모델의 설계 및 성능 평가 (Human Auditory Model Design and Quality Assessment)

  • Ryu, Seung-Wan;Kim, Su-Kweor;Park, Jeong-Yeol;Jaeho Shin
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 하계종합학술대회 논문집 Ⅳ
    • /
    • pp.2144-2147
    • /
    • 2003
  • Objective quality measurement schemes that incorporate properties of the human auditory system. The basilar membrane (BM) acts as a spectrum analyzer, spatially decomposing the signal into frequency components. Filterbanks were used to complementing the linearity of BM. Each filterbank is an implementation or the Equivalent rectangular Bandwidth (ERB), gammachirp function. This filterbank is level-dependent asymmetric compensation filters. And for the validation of the auditory model, we calculate the calculated perceived difference(CPD).

  • PDF

응답시간특성을 고려한 가스어레스터 모델 (A Gas Arrester Model Considering the Response Time Characteristics)

  • 박영호;송재용;길경석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.367-369
    • /
    • 1997
  • The process of designing protective circuits for signal lines usually consists of a time-consuming trial-and-error procedure, which also requires expensive equipment. However, computer simulation can drastically reduce the costs and time of design procedures based on experimental validation. In this study a gas arrester Pspice-model considering the response time characteristics is presented. The effects of various waveforms on the transient behaviors and firing voltages of a gas arrester were modeled by controlled voltage source E and TABLE function of PSpice, respectively. To estimate the characteristics of the gas arrester model proposed, three different voltage waveforms were used in the simulation and the measurement. The results of the computer simulation are in Rood agreement with the results of the experimental analysis.

  • PDF

가로림만 조력발전소 가동에 따른 조석체계 변화 예측 (Prediction of Tidal Regime According To Garolim Tidal Power Plant operation)

  • 강석구;이광수;박진순;염기대;정경태;장찬주
    • 신재생에너지
    • /
    • 제3권2호
    • /
    • pp.3-10
    • /
    • 2007
  • Tidal regime change with general hydrolic condition change is examined, according to Garolim Tidal Power Plant (TPP) operation. Numerical model has been developed for the Yellow and East China Seas region, in order to consider the tidal regime change by the TPP operation. The changes of tidal elevation and tidal current inside the Garolim bay are also investigated in details, along with examining the change of the tidal flat area with operation. The field measurement for the tide and current have been carried out for the validation of the numerical model and for understanding the state of current system in the present state.

  • PDF

TDOA 기법을 이용한 소음원 위치파악에 관한 인구 (Experimental Studies for Noise Source Positioning Using TDOA Algorithm)

  • 이욱;최종수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.138-142
    • /
    • 2006
  • Time Difference of Arrival (TDOA) algorithm was applied to sound source positioning. Using measured microphones signal, difference of distance from source to sensors were estimated by TDOA and speed of sound, and taken by navigational measurements. And iteration procedures were induced to find the actual source location. For the case of stationary and moving sound source, validation test were performed in the anechoic room. In the stationary case, the error of positioning is less then 1.3% in length scale, and it could be seen proper filtering processes were required in the application of moving sound source.

  • PDF

APR1400 원자로내부구조물 종합진동평가프로그램 진동 및 응력해석 방법론 검증 (Validation of Vibration and Stress Analysis Methodology for APR1400 Reactor Vessel Internals Comprehensive Vibration Assessment Program)

  • 김규형;고도영;김성환
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 추계학술대회 논문집
    • /
    • pp.300-305
    • /
    • 2012
  • The vibration and stress analysis program of comprehensive vibration assessment program (CVAP) is to verify theoretically the structural integrity of reactor vessel internals (RVI) and to provide the basis for selecting the locations monitored in measurement and inspection programs. This paper covers the verification of the vibration and stress analysis methodology of APR1400 RVI CVAP. The analysis methodology was developed to use 3-dimensional hydraulic and structural models with ANSYS and CFX. To validate the methodology, the hydraulic loads and structural reponses of OPR1000 were predicted and compared with the calculated and measured data in the OPR1000 RVI CVAP. Since the results predicted with this methodology were close to the measured values considerably, it was confirmed that the analysis methodology was developed properly.

  • PDF