• Title/Summary/Keyword: Measurement tool

Search Result 2,196, Processing Time 0.027 seconds

A Data Quality Measuring Tool (데이타 품질 측정 도구)

  • 양자영;최병주
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.9 no.3
    • /
    • pp.278-288
    • /
    • 2003
  • Quality of the software is affected by quality of data required for operating the actual software. Especially, it is important that assure the quality of data in a knowledge-engineering system that extracts the meaningful knowledge from stored data. In this paper, we developed DAQUM tool that can measure quality of data. This paper shows: 1) main contents for implement of DAQUM tool; 2) detection of dirty data via DAQUM tool through case study and measurement of data quality which is quantifiable from end-user's point of view. DAQUM tool will greatly contribute to improving quality of software product that processes mainly the data through control and measurement of data quality.

Measurement of Spindle Thermal Errors in a Machine Tool Using Hemispherical Ball Bar Test (반구상의 볼바측정을 통한 스핀들 열변형 오차 측정)

  • Yang, Seung-Han;Kim, Gi-Hun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.9
    • /
    • pp.1359-1367
    • /
    • 2001
  • Improvement of machine tool accuracy is an essential part of quality control in manufacturing process. Among of all the errors of a particular machine tool, the thermal errors of the spindle have a notably significant effect on machining accuracy and have a direct influence upon both the surface finish and geometric shape of the finished workpiece. Therefore, this paper proposed new measurement method for thermal errors of the spindle in machine tools. The thermal errors are measured by a ball bar system instead of capacitance sensor system. The novel measurement method using ball bar system is more efficient, easier to use than conventional measurement system. And also the ball bar system is possible to measure both geometric errors and thermal errors at the same time.

Hybrid Machine with Open Architecture Controller (개방형 CNC를 응용한 하이브리드 머신 개발)

  • 김선호;김동훈;박정환;고태조;구태중
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.338-342
    • /
    • 2003
  • Hybrid machine is based on hardware technologies of machine tool and software technologies of open architecture controller. In machining technology, combination technology of turning, milling, and grinding and in machining energy technology. combination of mechanical, electrical, and chemical technology are developed. This paper describes hybrid machine technology for combination of machining, on-machine measurement, on-machine CAM, and on-machine remote monitoring and control in open architecture controller environment. For on-machine measurement, non-contact measurement technology based on CAD information is developed. For on-machine CAM, interactive CAM program for automatic NC program generation and tool path simulation is developed. For generation on-machine remote monitoring and control, suitable interface method between web program and CNC is proposed. The developed hybrid machine technology is implemented in 3 axes milling machine for evaluation of operablity.

  • PDF

Development of Performance Measures Based on Nursing Process for Oxygen Therapy and Airway Suctioning (간호과정 적용 평가도구 개발 -산소요법과 흡인간호를 중심으로-)

  • Kim, Keum Soon;Choi, Yun Kyoung;Lee, Jung Lim;Ahn, Jung Won;Lee, So Lim;Choi, Won Ja;Kim, Eul Soon
    • Journal of Korean Clinical Nursing Research
    • /
    • v.19 no.1
    • /
    • pp.1-19
    • /
    • 2013
  • Purpose: This study was conducted to develop standards to ensure nursing process-based care of oxygen therapy and airway suctioning and to develop a performance measurement tool to evaluate the care applied according to the standards, and finally to determine validity of the standards and the tool. Methods: The standards and the tool were reviewed by a panel of experts and refined based on the panel's suggestions. Validity of the standards and the tool were examined through surveying a total of 366 hospital nurses. Results: The mean validity scores of the performance measurement standards and the tool were 3.58 and 3.55, respectively, out of 4.00. So the performance measurement standards and the tool in this study were found to be acceptable in evaluating quality of nursing care provided at patient admission and discharge. Conclusion: This result indicates that the performance measurement standards and the tool developed in this study are valid instruments to monitor and improve quality of nursing care for oxygen therapy and airway suctioning.

Development of Performance Measures Based on Nursing Process for Fluid Intake/Output and Tube Care (간호과정 적용 평가도구 개발 -수분섭취/배설간호와 튜브간호를 중심으로-)

  • Kim, Keum Soon;Choi, Yun Kyoung;Choi, Wan Hee;Ahn, Jung Won;Kim, Jin A;Park, Seung Mi;Choi, Kyung Ok;Kim, Eul Soon
    • Journal of Korean Clinical Nursing Research
    • /
    • v.18 no.1
    • /
    • pp.13-28
    • /
    • 2012
  • Purpose: This study was conducted to develop standards ensuring nursing process-based fluid intake/output and tube care, and to develop a performance measurement tool evaluating the level of care according to the standards, and finally to determine validity of the standards and the tool. Methods: The standards and the tool were reviewed by a panel of experts and refined based on the panel's suggestions. Validity of the standards and the tool were examined using a survey of 293 hospital nurses. Results: The mean validity scores of the performance measurement standards and the tool were 3.86 and 4.02, respectively, out of 5.00. So the performance measurement standards and the tool in this study were found to be acceptable in evaluating quality of nursing care for fluid intake/output and tubes. Conclusion: This result indicates that the performance measurement standards and the tool developed in this study are valid instruments to monitor and improve quality of nursing care for fluid intake/output and tube interventions, such as intravenous catheters, nasogastric tube and urinary catheters.

Development of Performance Measures Based on Nursing Process for Admission and Discharge Care (간호과정 적용 평가도구 개발 -입원 및 퇴원 시 간호를 중심으로-)

  • Kim, Keum Soon;Kim, Jin A;Choi, Yun Kyoung;Kim, Eun Man;Kim, Yu Jeong;Kim, Mi Ae;Kim, Kyoung Ok;Kim, Eul Soon
    • Journal of Korean Clinical Nursing Research
    • /
    • v.17 no.2
    • /
    • pp.123-137
    • /
    • 2011
  • Purpose: This study was conducted to develop standards ensuring nursing process-based care of patient admission and discharge, to develop a performance measurement tool evaluating the care applied according to the standards, and finally to determine validity of the standards and the tool. Methods: The standards and the tool were reviewed by a panel of experts and refined based on the panel's suggestions. Validity of the standards and the tool were examined through surveying a total of 302 hospital nurses. Results: The mean validity scores of the performance measurement standards and the tool were 4.11 and 4.09, respectively, out of 5.00. So the performance measurement standards and the tool in this study were found to be acceptable in evaluating quality of nursing care provided at patient admission and discharge. Conclusion: This result indicates that the performance measurement standards and the tool developed in this study are valid instruments to monitor and improve quality of nursing care for patient admission and discharge.

Detection of Tool Wear using Cutting Force Measurement in Turning (선삭가공에서 절삭력을 이용한 공구마멸의 감지)

  • 윤재웅;이권용;이수철
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2000.06a
    • /
    • pp.68-75
    • /
    • 2000
  • The development of flexible automation in the manufacturing industry is concerned with production activities performed by unmanned machining system. A major topic relevant to metal-cutting operations is monitoring tool wear, which affects process efficiency and product quality, and implementing automatic tool replacements. In this paper, the measurement of the cutting force components has been found to provide a method for an in-process detection of tool wear. Cutting force components are divided into static and dynamic components in this paper, and the static components of cutting force have been used to detect flank wear. To eliminate the influence of variations in cutting conditions, tools, and workpiece materials, the force modeling is performed for various cutting conditions. The normalized force disparities are defined in this paper, and the relationships between normalized disparity and flank wear are established. Finally, Artificial neural network is used to learn these relationships and detect tool wear. According to the proposed method, the static force components could provide the effective means to detect flank wear for varying cutting conditions in turning operation.

  • PDF

Development of Calibrating Instrument for Tool Wear using Spindle Orientation Function in End Milling (엔드밀 가공시 주축 오리엔테이션 기능을 통한 공구마멸 보정 장치의 개발)

  • Kim, Jeon-Ha;Kang, Myung-Chang;Kim, Jeong-Suk;Kim, Kwang-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.7
    • /
    • pp.1095-1102
    • /
    • 2003
  • The most important thing in measuring the tool wear is to set up the measurement base. The end mill that is being used for machining of die is difficult to set up the base and to measure the tool wear because of geometric properties of that such as a helix and relief angle. In this study, a new instrument using spindle orientation function in end milling is developed to measure the tool wear and evaluated by the measuring system on the machine. Finally, this new method makes possible the wear measurement of same position and reduces the measuring time compared with the measuring methods such as the microscope and CCD.

System development for the wear measurement offend mill on the machine (엔드밀의 마멸 측정을 위한 기상계측 시스템 개발)

  • 김전하;문덕규;강명창;김정석;김기태
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.59-64
    • /
    • 2002
  • Recently the applications of high speed machining are increasing due to the need for high performance and high accuracy machining and machining for difficult-to-cut material. However, the high speed machining also accompanies some problems: the product quality can be degraded due to the tool wear and the product cast can go up due to frequent tool replacements. Therefore, it is necessary to develop a technique of quantitative tool wear measurement to determine the precise timing for tool replacement. In this respect, this study suggests a reliable technique far the reduction of error components by developing a system using a CCD camera and an exclusive jig to be able to precisely measure the size of tool wear in flat end mill for high speed machining.

  • PDF