• Title/Summary/Keyword: Measurement of Performance

Search Result 7,000, Processing Time 0.031 seconds

A Study on the Performance Indicators of SME's International Marketing Program (중소기업 수출역량강화사업의 성과지표에 관한 연구)

  • Han, Min-Chung;Ahn, Byung-Soo
    • International Commerce and Information Review
    • /
    • v.16 no.3
    • /
    • pp.141-158
    • /
    • 2014
  • This research is intended to improve the performance of "small and medium companies international marketing program" by screening the performance indicators of the program. The program aims to prepare SMEs to penetrate foreign market and become global companies eventually. This research analyzed the current SMEs international marketing programs based on Logic Model to find the current performance measurement lacks in qualitative indicators and process evaluation with focusing on quantitative indicators and short term result evaluation. Therefore, the measurement indicators should be balanced between process and results including mid-term and long term results.

  • PDF

A Cumulative Injected Fuel Mass Measurement Under a Vehicle Driven Condition using Loadcells (차량주행 모사 조건에서 로드셀을 이용한 인젝터 누적 연료 분사량 측정)

  • Cho, Seung Keun;Lee, Choong Hoon
    • Journal of ILASS-Korea
    • /
    • v.21 no.1
    • /
    • pp.1-6
    • /
    • 2016
  • A gasoline injector rig which can measure cumulative injected fuel mass under a vehicle driving condition was developed. The measurement system consists of an engine control unit (ECU), data acquisition (DAQ) and injected fuel collection system using loadcells. By supplying reconstructed sensor signals which simulate the real vehicle's sensor signals to the ECU, the ECU drives injectors as if they were driven in the vehicle. The vehicle's performance was computer simulated by using $GT-Suite^{(R)}$ software based on both engine part load performance and automatic transmission shift map. Throttle valve position, engine and vehicle speed, air mass flow rate et al. were computer simulated. The used vehicle driving pattern for the simulation was FTP-75 mode. For reconstructing the real vehicle sensor signals which are correspondent to the $GT-Suite^{(R)}$ simulated vehicle's performance, the DAQ systems were used. The injected fuel was collected with mess cylinders. The collected fuel mass in the mess cylinder with elapsed time after starting FTP-75 driving mode was measured using loadcells. The developed method shows highly improved performance in fast timing and accuracy of the cumulative injected fuel mass measurement under the vehicle driven condition.

Soft Real-time Capabilities and Communication Performance Evaluation in Qplus for Multimedia Streaming Service (멀티미디어 스트리밍 서비스에 대한 QPLUS의 연성 실시간 및 통신 성능 평가)

  • Lee, GowangLo;Bae, ByeongMin;Lee, InHan;Kim, MinJung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.301-304
    • /
    • 2013
  • In this paper, to improve the fast boot and soft real-time for the responsiveness in Qplus with relative evaluation rather than an absolute evaluation using validated to perform the services actually used. Qplus is included soft real-time, fast booting, and file system technology. There is a development board that mounted on an embedded Linux and Qplus. AV (Audio / Video) group communications is ported on the development board for soft real-time multimedia streaming services and to evaluate the performance of communication. We performed three major evaluation such as booting time measurement experiment, own performance measurement experiments for soft real-time measurement experiment, and performance measurement experiments for via the network communication performance evaluation. They are a practical Qplus performance evaluation and analysis.

  • PDF

Development of Performance Analysis Methodology for Nuclear Power Plant Turbine Cycle Using Validation Model of Performance Measurements (원전 터빈사이클 성능 데이터의 검증 모델에 의한 성능분석 기법의 개발)

  • Kim, Seong-Geun;Choe, Gwang-Hui
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.12
    • /
    • pp.1625-1634
    • /
    • 2000
  • Verification of measurements is required for precise evaluation of turbine cycle performance in nuclear power plant. We assumed that initial acceptance data and design data of the plant could provide correlation information between performance data. The data can be used as sample sets for the correct estimation model of measurement value. The modeling was done practically by using regression model based on plant design data, plant acceptance data and verified plant performance data of domestic nuclear power plant. We can construct more robust performance analysis system for an operation nuclear power plant with this validation scheme.

Airport Performance Measurement and Airport Operation System Improvement (우리 나라 공항 운영성과 지표 측정 및 활용방안 연구)

  • Yoo, K.E.;Lee, Y.H.
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.9 no.1
    • /
    • pp.45-58
    • /
    • 2001
  • According to the liberalization of the air transport industry, the operation of airport also takes account of economic efficiency. The owners or the operators of an airport or airport systems want to know what is the best way to achieve the best performance in the aspect of economic efficiency and they are willing to improve the airport operation system. Prerequisite for the improvement of economic efficiency is to measure the performance of not only their own airports but the other airports. This study presents the result of performance measurement of Korean airports. The overall costs performance, labor productivity, capital productivity, revenue performance and profit performance are estimated and interpreted. As conclusions, the suggestion about airport system improvement is presented.

  • PDF

Absolute Temperature Measurement using White Light Interferometry

  • Kim, Jeong-Gon
    • Journal of the Optical Society of Korea
    • /
    • v.4 no.2
    • /
    • pp.89-93
    • /
    • 2000
  • Recently a new signal processing algorithm for white light interferometry was presented. In this paper, the proposed signal processing algorithm was applied for absolute temperature measurement using white light interferometry. Stability testing and absolute temperature measurement were demonstrated. Stability test demonstrated the feasibility of absolute temperature measurement with an accuracy of 0.015 fringe. The test also showed that the absolute temperature measurement system using white light interferometry is capable of obtaining the theoretical minimum detectable change (0.0005 fringe), which is consistent with the performance predicted by the proposed signal processing algorithm.

Salinity Determination Using Temperature Compensated On-Line Refractometer (온도보상형 온라인 굴절계를 이용한 해수의 염도 측정)

  • 최한욱;김영한
    • Journal of Korean Port Research
    • /
    • v.15 no.1
    • /
    • pp.99-105
    • /
    • 2001
  • An on-line refractrometer made of easily obtainable materials is built to determine the salinity and temperature of sea water, and its performance is examined by applying the refractometer to known salt solution. Since refractive index and temperature are measured simultaneously, it is possible to compensate the effect of temperature for accurate measurement. The outcome of salinity measurement for the different concentrations of salt solution indicates that the device is suitable for the salinity measurement by yielding stable and reproducible reading.

  • PDF

측정기의 효율적 운영에 관한 실증적 연구

  • Yu, Hyeon-Jong;Jeong, Su-Il
    • Journal of the Korea Construction Safety Engineering Association
    • /
    • s.48
    • /
    • pp.64-74
    • /
    • 2009
  • Measurement is a essential part in all kinds of industry, especially in manufacturing. But until now, measurement hasn't been located to the core of manufacturing in domestic. This improvement guide line for the multilateral problems of measuring instrument investigation of small and medium-sized enterprises. To use measuring treat it must be accustomed with the structure, the performance, the method. must be corrected periodically. The correcting-schedule is established with accuracy, stability, purpose, condition, and frequency.

  • PDF

Spectral clustering based on the local similarity measure of shared neighbors

  • Cao, Zongqi;Chen, Hongjia;Wang, Xiang
    • ETRI Journal
    • /
    • v.44 no.5
    • /
    • pp.769-779
    • /
    • 2022
  • Spectral clustering has become a typical and efficient clustering method used in a variety of applications. The critical step of spectral clustering is the similarity measurement, which largely determines the performance of the spectral clustering method. In this paper, we propose a novel spectral clustering algorithm based on the local similarity measure of shared neighbors. This similarity measurement exploits the local density information between data points based on the weight of the shared neighbors in a directed k-nearest neighbor graph with only one parameter k, that is, the number of nearest neighbors. Numerical experiments on synthetic and real-world datasets demonstrate that our proposed algorithm outperforms other existing spectral clustering algorithms in terms of the clustering performance measured via the normalized mutual information, clustering accuracy, and F-measure. As an example, the proposed method can provide an improvement of 15.82% in the clustering performance for the Soybean dataset.

A Study on the Operational Status of the Chamber for Testing the Thermal Performance of Curtain Walls

  • No, Sang Tae
    • International Journal of High-Rise Buildings
    • /
    • v.3 no.2
    • /
    • pp.147-154
    • /
    • 2014
  • The purposes of this study were to analyze criteria for measurement chamber design dedicated curtain wall, and how to measure of performance configuration and status of the chamber that is currently being used. Main dealing criteria is AAMA 1503-09. Measurement of data is made in curtain wall Mock-up experiment station with thermal imaging camera. Measurement data using thermal imaging cameras at Mock-up curtain was made at the test site. The results of this study were as follows; There is no U-value test method for actual size of curtain wall. The thermal test outdoor chamber showed heat loss in the connection part of indoor and outdoor chamber. And the indoor chamber showed unstable temperature distribution by height.