• 제목/요약/키워드: Measurement of Performance

검색결과 6,954건 처리시간 0.045초

Downlink Signal Measurement Algorithm for WCDMA/HSPA/HSPA+

  • Kwon, Bit-Na;Lee, Eui-Hak;Hong, Dae-Ki;Kang, Sung-Jin;Kang, Min-Goo;Song, Hyoung-Kyu
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제9권8호
    • /
    • pp.3040-3053
    • /
    • 2015
  • Wideband code division multiple access (WCDMA), high speed packet access (HSPA) and HSPA+ are third generation partnership project (3GPP) standards. These systems are the major wireless communication standards. In order to test the performance of WCDMA/HSPA/HSPA+ signal in a base station, the measurement hardware is required to the evaluation of the transmitted signals. In this paper, the algorithm for the performance measurement of the WCDMA/HSPA/HSPA+ is proposed. Also, the performance of the measurement algorithm is used to evaluate the generated signal by the WCDMA/HSPA/HSPA+ signal generator. Generally, the algorithm of normal modems cannot be applied to the measurement system because the signal measurement equipment needs to guarantee the high accuracy. So, the WCDMA/HSPA/HSPA+ signal measurement algorithm for the accurate measurement is proposed. By the simulation, it is confirmed that the proposed measurement algorithm has good performance compared with the specification. Therefore, the proposed algorithm can be usefully applied to verify the performance of the measurement using the simulation.

기계통풍식 냉각탑 유닛의 성능에 관한 실험적 연구 (An Experimental Study on the Performance of Cooling Tower Unit for Mechanical Draft)

  • 정순영
    • 한국수소및신에너지학회논문집
    • /
    • 제32권6호
    • /
    • pp.642-648
    • /
    • 2021
  • In this paper, an experimental study was conducted on the performance of the cooling tower. In order to improve reliability in the cooling tower performance test, the measurement uncertainty of the instrument was estimated. Measurement uncertainty refers to the uncertainty of a measurement, estimates the range in which the expected value of the measurement can be within a certain confidence level, and suggests a range in which the measured representative value is incorrect. Therefore, the measurement result of the performance experiment is not an actual value, but a reasonable estimated value. The measurement uncertainty for the test was calculated and the measured results were presented.

성과 정보 통합 방법의 개발 (Developing a Performance Information Integration Method (PIIM))

  • 박창규
    • 산업공학
    • /
    • 제11권3호
    • /
    • pp.41-53
    • /
    • 1998
  • Several performance measurement systems have been proposed and are currently being used in many organizations. However, no performance measurement system has presented a mechanism for integrating all of the information of performance measures in a way that considers the relationships between them. This paper proposes the performance information integration method (PIIM) which synthesizes all useful information of performance measures with consideration of the relationships and generates a single, global, organizational performance score. The PIIM showed good performance in the implementation in one long-term care facility. This paper provides performance measurement systems with an integration mechanism for multiple performance measures.

  • PDF

신재생에너지 지열을 이용한 열펌프유닛의 성능에 관한 실험적 연구 (An Experimental Study on the Performance of Heat Pump Unit Using Geothermal Heat for New Renewable Energy)

  • 정순영
    • 한국수소및신에너지학회논문집
    • /
    • 제31권6호
    • /
    • pp.630-636
    • /
    • 2020
  • This paper presents a experimental study on the performance of the heat pump. Uncertainty of measurement means the degree of uncertainty in the measurement. Therefore, it estimates a section where expected value of the measurement might be within a certain confidence level and suggests a range where measured representative value might be incorrect. Uncertainty of measurement is a parameter that shows characteristics of dispersion of measured value that was reasonably estimated from measured quantity. Measurement result of performance experiment is not a true value but estimated value that was estimated reasonably. Therefore, uncertainty of measurement needs to be calculated and presented with the result of measurement.

정보시스템 통합단계별 성과측정 모형 및 물리적 통합단계의 측정지표 개발에 관한 연구 (A Study on Development of Integration Performance Measurement Model for Each Stage of Information Systems Integration and Measurement Indicators of Physical Integration Stage)

  • 정해용;나종회
    • 한국IT서비스학회지
    • /
    • 제7권4호
    • /
    • pp.247-268
    • /
    • 2008
  • This study aims to develop an integration performance measurement model for each stage of information systems integration. In order to achieve the purpose of the research, first of all, the concepts of IS integration or consolidation are analyzed through theoretical and practical reviews. Also, a number of important studies of domestic and overseas cases about the stage models of IS integration or consolidation are critically reviewed. Second, we proposed three step stage model of is integration, Physical Integration stage, Application Integration stage, Service Integration stage, and Also proposed the performance measurement model for each stage of information systems integration. Third, especially in case of performance indicators and performance measurement methodology for physical integration stage are illustratively proposed, based upon the case of NCIA (National Computing Integration Agency) in Korea. This study provides the theoretical basis for reasonably deriving the stage model and performance measurement model for each stage of Information Systems Integration, and they are validating through investigating domestic and foreign practices. The results of this study are very likely to contribute to presenting the practical guideline for desirably implementing is integration or IS consolidation.

터보샤프트 엔진 고공성능시험의 측정 불확도 평가 (Measurement Uncertainty Assessment of Altitude Performance Test for a Turboshaft Engine)

  • 양인영;이보화
    • 한국추진공학회지
    • /
    • 제14권4호
    • /
    • pp.59-64
    • /
    • 2010
  • 터보샤프트 엔진의 고공성능시험에서 주요 성능 인자인 축마력, 연료 유량, 비연료 소모율 및 공기유량에 대하여 측정의 수학적 모델을 제시하고 측정 불확도를 평가하였다. 터보제트 및 터보팬 엔진의 경우와 비교하여 차이점을 논의하였다. 시험 조건의 측정 불확도를 평가하였으며, 이를 보정된 성능 데이터 측정 불확도에 반영하는 방법을 제시하였다. 실제 터보샤프트 엔진 고공성능시험설비를 이용한 시험 사례에 대한 측정 불확도 평가 결과를 제시하였다. 주요 성능 인자의 측정 불확도는 시험 조건측정의 불확도를 반영하였을 경우 0.65~1.09%, 반영하지 않았을 경우 0.36~0.94%로 평가되었다.

BSC를 이용한 B2B e-Marketplace 성과평가 모형 개발 (Development of Performance Measurement Model for B2B e- Marketplace using BSC)

  • 박철수
    • 대한안전경영과학회지
    • /
    • 제5권4호
    • /
    • pp.229-243
    • /
    • 2003
  • This paper suggests the process of performance measurement system development for B2B e-Marketplace using BSC (Balanced Scorecard). As the first step, main features and factors affecting performance of e-Business company and especially of B2B e-Marketplaces were derived based on the literatures. For the 2nd step, the nonnative performance measurement model for B2B e-Marketplace was suggested. Especially, the research range that the model covers is restricted to the neutral and systematic sourcing B2B e-Marketplace. And, the performance measurement model was based on BSC, for the BSC is very powerful and sound tool among all the available performance measurement systems. Also, the model was based on the AHP (Analytic Hierarchy Process) to make the model more structured, and to draw weights of performance measures from experts

예산관리제도의 도입과 실제적 운용에 관한 사례연구 -표준적인 작업의 성과측정을 중심으로- (The Case Study on The Introduction and Practical Application of the Budget Management System -On the Performance Measurement of Standard Work Unit-)

  • 윤용운
    • 산업경영시스템학회지
    • /
    • 제2권2호
    • /
    • pp.39-51
    • /
    • 1979
  • In introducing and applying the budget management system, the question of how to establish management structure(skelton) representing budget management responsible unit is significantly related to the degree of accuracy and analysis on the performance measurement of standard work unit. We have the following rational process of establishing performance measurement of budget management System ; 1) Standardization of work method 2) Establishment of management structure 3) Institution of budget management system. Especially, this system is based on a premise of efficiency of objectives management, it is assumed that performance measurement in the standard work unit must be enforced according to the basis and categories of performance evaluation based on the evaluating work unit. Therefore, most of all, the following three detail questions(subjects) are to be determined in order to rationalize these above principles to a maximum possible extent of performance measurement system. First, we established respective performance standard unit with respect to such detailed work unit, performance standard unit of which were accurately applicable directly from using the budget ana objectives account data and their supplementary data of the work measurement techniques. Second, by using the above mentioned question, over all evaluation and suggestion are made based on the study of the recording for each work unit development, budget management and production nit (volume of production) Third, the measurement of performance of budget management system is based on the principle of standard work unit, compared with the standard basis and actual work unit by period and activities unit and calculated percentage effectiveness according to the above procedure. and so evaluated the efficiency of performance measurement on the budget management system.

  • PDF

균형성과표를 활용한 전자의무기록시스템의 성과측정 모형개발 (Development of the Performance Measurement Model of Electronic Medical Record System - Focused on Balanced Score Card -)

  • 이경희;김영훈;부유경
    • 한국병원경영학회지
    • /
    • 제21권4호
    • /
    • pp.1-12
    • /
    • 2016
  • The purpose of this study are suggest to performance measurement model of Electronic Medical Record(EMR) and Key Performance Index(KPI). For data collection, 665 questionnaires were distributed to medical record administrators and insurance reviewers at 31 hospitals, and 580 questionnaires were collected(collection rate: 87.2%). Regarding methodology, Critical Success Factor(CSF) and index of the information system were derived based on previous studies, and these were set as performance measurement factors of EMR system. The performance measurement factors were constructed by perspective using BSC, and analysis on causal relationship between factors was conducted. A model of causal relationship was established, and performance measurement model of EMR system was proposed through model validation. Analysis on causal relationship between performance management factors revealed that utility cognition of the learning & growth perspective factor had causal relationship with job efficiency(${\beta}=0.20$) and decision support(${\beta}=0.66$) of the internal process perspective factors, and security had causal relationship with system satisfaction(${\beta}=0.31$) of the customer perspective factor. System quality had causal relationship with job efficiency(${\beta}=0.66$) and decision support(${\beta}=0.76$) of the internal process perspective factors, all of which were statistically significant(P<0.01). Job efficiency of the internal process perspective had causal relationship with system satisfaction(${\beta}=0.43$), and decision support had causal relationship with decision support satisfaction(${\beta}=0.91$) and job satisfaction (${\beta}=0.74$), all of which were statistically significant(P<0.01). System satisfaction of the customer perspective had causal relationship with job satisfaction(${\beta}=0.12$), job satisfaction had causal relationship with cost reduction(${\beta}=0.53$) of the financial perspective, and decision support satisfaction had causal relationship with productivity improvement(${\beta}=0.40$)of the financial perspective(P<0.01). Also, cost reduction of the financial perspective had causal relationship with productivity improvement(${\beta}=0.37$), all which were statistically significant(P<0.05). Suitability index verification of the performance measurement model whose causal relationship was found to be statistically significant revealed that $X^2/df=2.875$, RMR=0.036, GFI=0.831, AGFI=0.810, CFI=0.887, NFI=0.838, IFI=0.888, RMSEA=0.057, PNFI=0.781, and PCFI=0.827, all of which were in suitable levels. In conclusion, the performance measurement indices of EMR system include utility cognition, security, and system quality of the learning & growth perspective, decision support and job efficiency of the internal process perspective, system satisfaction, decision support satisfaction, and job satisfaction of the customer perspective, and productivity improvement and cost reduction of the financial perspective. In this study, it is expected that the performance measurement indices and model of EMR system which are suggested by the author, will be a measurement tool available for system performance measurement of EMR system in medical institutions.

수소연료전지자동차용 절연저항 측정시스템 개발에 관한 연구 (Study on Development of the Isolation Resistance Measurement System for Hydrogen Fuel Cell Vehicle)

  • 이기연;김동욱;문현욱;김향곤
    • 전기학회논문지
    • /
    • 제60권5호
    • /
    • pp.1068-1072
    • /
    • 2011
  • Hydrogen Fuel Cell Vehicle(HFCV) is system that uses electrical energy of fuel cell stack to main power source, which is different system with other vehicles that use high-voltage, large-current. Isolation performance of this system which is connected with electrical fire and electrical shock is important point. Isolation resistance of electric installation is divided according to working voltage, it follows criterion more than $100{\Omega}$/VDC (or $500{\Omega}$/VAC) about system operation voltage in a hydrogen fuel cell vehicle. Although measurement of isolation resistance in a hydrogen fuel cell vehicle is two methods, it uses mainly measurement by megger. However, the present isolation resistance measurement system that is optimized to use in electrical facilities is unsuitable for isolation performance estimation of a hydrogen fuel cell vehicle because of limit of maximum short current and difference of measurement resolution. Therefore, this research developed the isolation resistance measurement system so that may be suitable in isolation performance estimation of a hydrogen fuel cell vehicle, verified isolation performance about known resistance by performance verification of laboratory level about developed system, and executed performance verification through comparing results of developed system by performance verification of vehicle level with ones of existing megger. Developed system is judged to aid estimation and upgrade of isolation performance in a hydrogen fuel cell vehicle hereafter.