• Title/Summary/Keyword: Measurement of Immersion

Search Result 122, Processing Time 0.027 seconds

Dependence of Turn-On Voltage and Surface State Density on the Silicon Crystallographic Orientation (실리콘 결정의 방향성에 따른 Turn-On 전사과 추면대융단파의 상대성에 관한 연구)

  • 성영권;성만영;조철제;고기만;이병득
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.33 no.4
    • /
    • pp.157-163
    • /
    • 1984
  • The object of this paper is to investigte the gate controlled diode structure for ionic concentration measurement. It includes device fabrication, characterization, device physics and modeling of the gate controlled diode structure. The differences of turn on voltages and surface generation currents in the (100) and (111) silicon crystallographic orientation of the sample device were observed. Therefore the dependence of these two factors of the silicon crystallographic orientation was investigated. It was observed that drifts arose after extended immersion of the sample device in acid or base solutions. The surface generation-recombination velocity of both (100) and (111) increased. The increase in the interfacial traps for both surface, determined by the turn on voltage was directly proportional to the surface generation-recombination velocity increase.

  • PDF

Study on the Feasibility of High-Temperature Immersion Ultrasonic Sensor with a Strip Waveguide (도파띠를 이용한 고온 액침 초음파센서의 가능성 연구)

  • Choi, M.S.;Lee, J.P.;Jung, T.E.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.14 no.3
    • /
    • pp.151-156
    • /
    • 1994
  • Exertion has been made to develop high-temperature (about $250{\sim}650^{\circ}C$) immersion ultrasonic sensor for the visualization of objects, temperature measurement, dimensional check, or nondestructive testing of welds under liquid sodium. In this study, the feasibility of the ultrasonic sensor taking advantage of a strip waveguide was confirmed by water-experiment. The lowest order of antisymmetric Lamb wave was used in the frequency range with negligible dispersion. This plate wave was excited in the stainless steel strip waveguide of 1.0mm thickness and 13mm width by the comb-structure transducer of 2.3MHz frequency. Its attenuation coefficient was 1.2dB/m in air and 380dB/m in water. The signal to noise ratio of 25dB was obtained from a planar reflector 270mm away from the beam aperture of $13mm{\times}39mm$ size.

  • PDF

Optical Performance Evaluation of SIL Assembly with Lateral Shearing Interferometer (층 밀리 간섭계를 이용한 고체침지렌즈의 광학적 성능 평가)

  • Lee, Jin-Eui;Kim, Wan-Chin;Choi, Hyun;Kim, Tae-Seob;Yoon, Yong-Joong;Park, No-Cheol;Park, Young-Pil
    • Transactions of the Society of Information Storage Systems
    • /
    • v.2 no.4
    • /
    • pp.224-229
    • /
    • 2006
  • There has been studied flow to minimize the spot size to increase data capacity. Optical data storage devices are being developed near practical limits with wavelength and NA of 405nm and 0.85. There has been studied many types of next generation storage devices such as blu-ray multilayer system, probe based data storage and holographic data storage. Among these data storage devices, solid immersion lens(SIL) based near field recording (NFR) has been widely studied. In this system, SIL is the key component that focuses the laser beam with a very small size which enables ultra high data capacity. Therefore, optical performance evaluation system is required for SIL assembly. In this dissertation, a simple and accurate SIL assembly measurement method is proposed with wedge plate lateral shearing interferometer(LSI). Wedge plate LSI is cheaper than commercialized interferometer, robust to the vibration and the moving distance for phase shifting is large that is order of micrometer. We designed the thickness, wedge angle, material, surface quality and wavelength of wedge plate as 1mm, 0.02degree, fused silica, lamda/10(10-5) and 405nm, respectively. Also, we confirmed simulation and experimental results with quantitative analysis. This simple wedge plate LSI can be applied to different types of SIL such as solid immersion mirror(SIM), hemispherical, super-hemispherical and elliptical SIL.

  • PDF

Measurement of degree of contents immersion with using the portable EEG device (포터블 EEG를 활용한 콘텐츠 몰입도 평가)

  • Keum, Nam-Ho;Lee, Taek;Lee, Jung-Been;In, Hoh Peter
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2015.10a
    • /
    • pp.1681-1684
    • /
    • 2015
  • 최근 소형 모바일 디바이스가 발달함에 따라 시간적, 공간적 제약이 없이 대량의 콘텐츠가 소비되고 있는 환경에서 콘텐츠 소비 만족도 및 몰입도를 측정하기 위해 사용자 피드백을 설문 조사하는 기존 방식은 비효율적이다. 왜냐하면 수작업에 의존하고 객관성이 결여된 데이터가 수집될 가능성이 있기 때문이다. 따라서 최근 연구에서는 EEG를 활용한 방법이 하나의 대안으로 제시되고 있다. 본 논문에서는 기존 설문조사 방식의 한계점을 보완하고 기존 EEG방식의 단점을 개선하기 위한 포터블 EEG를 활용하는 방법을 제안하였다. 소형 및 간편함을 확보하기 위하여 배터리 환경에 비 접착식 단일전극을 이용하여 EEG를 측정하고 주파수 분석을 통하여 집중력과 관련된 파형을 분리, 콘텐츠 몰입도를 점수화 하였다. 마지막으로 실험을 통해 앞서 산출한 점수와 콘텐츠의 흥미도가 비례관계에 있음을 증명하였다.

Effects of Ageing Factors on Low Molecular Weight Silicone Fluids Content Fluids Content and Surface Hydrophobicity in HTV Silicone Rubber (HTV 실리콘 고무에서 열화인자에 따른 저분자량 성분과 표면 발수성의 변화)

  • 허창수;연복희;조한구
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.12 no.1
    • /
    • pp.1-10
    • /
    • 1999
  • In this paper, we have investigated the effects of the environmental factors on Low Molecular Weight (LMW) silicone fluid contents existing in high temperature vulcanized (HTV) silicone rubber sample, using dipping method and contact angle, current measurement. Artificial treatments such as immersion in water, elevated temperature, UV irradiation and dry band arcing under salt-fog condition are selected as the environmental factors. This results will be helpful to investigate the degradation with time and to expect a life time, because the LMW silicone content, which is important to recovery the hydrophobicity of silicone rubber surface, show different results by each environmental factors.

  • PDF

A Study on Reliability and Applicability of Oriental Medical Music Therapy Using (음악요법의 한의학적 활용을 위한 신뢰도 및 적용 가능성 연구)

  • Song, Min Sun;Choi, Chan Hun
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.28 no.6
    • /
    • pp.674-682
    • /
    • 2014
  • The purpose of this study was to identify the effect of applying oriental music therapy and reliability of electroencephalogram(EEG) equipment. The study was approved by the critical trial judge committee from ${\bigcirc}{\bigcirc}$(IRB No. 2013-07) university. In order to measure test-retest reliability for 15 subjects, EEG for same participants were measured using same method mentioned above after 2 hours from the first measurement. Same provider implemented to each person at same time. Firstly, EEG was measured for 5 minutes after the subject with attached electrodes sat on chair comfortably for 10 minutes. Then, the subject was given mental stress using the four fundamental arithmetic operations for 5 minutes, and measured EEG for another 5 minutes. After that the subject sat on the chair comfortably listening oriental medicine music therapy for 5 minutes, and EEG was measured for 5 minutes again. There was no side effect regarding music therapy reported. Raw data, which was measured in each step, were converted through FFT(fast fourier transform) and analyzed after divided into certain frequency including ${\alpha}$ wave, ${\beta}$ wave, ${\theta}$ wave, immersion wave, stabilization wave, sef100 wave, and sef95 wave. Data were analyzed using wilcoxon signed rank test, Intraclass correlation coefficient(ICC), repeated measures ANOVA with the SPSS program. In test-retes method, there were significantly differences in ${\alpha}$ wave, ${\beta}$ wave, immersion wave, stability wave, ${\theta}$ wave, sef100 wave, sef95 wave. ICC has shown a high degree of reliability that it was ${\alpha}$ wave .877, ${\beta}$ wave .855, ${\gamma}$ wave .895, immersion wave .897, stability wave .816, ${\theta}$ wave .904, sef100 wave .910, sef95 wave .776. Also, there was a statistically significant difference in ${\alpha}$ wave after applying oriental music therapy. Based on these results, it is considered that average of the channel EEG and application of oriental music therapy would be practiced by increase of sample size using this machine.

Comparative analysis of strain according to two wavelengths of light source and constant temperature bath deposition in ultraviolet-curing resin for dental three-dimensional printing (치과 3D 프린팅용 자외선 경화 레진에 광원의 두 가지 파장에 따른 경화 및 항온수조 침적에 따른 변형률의 비교 분석)

  • Kim, Dong-Yeon;Lee, Gwang-Young;Kang, Hoo-Won;Yang, Cheon-Seung
    • Journal of Technologic Dentistry
    • /
    • v.42 no.3
    • /
    • pp.208-212
    • /
    • 2020
  • Purpose: This study aimed to analyze the shrinkage and expansion strain of ultraviolet (UV)-cured resin according to the wavelength of the light source and compare the shrinkage and expansion. Methods: We prepared the mold with according to the ISO 4049 specimen. The size of the circle in the mold was prepared with a height of 6.02 mm and a diameter of 4 mm. UV-curable resin for three-dimensional (3D) printing was injected into the circular mold. The control group was irradiated with a wavelength of 400~405 nm using UV-curing equipment (400 group), and the experimental group was irradiated with a wavelength of 460~465 nm (460 group). Both groups were produced ten specimens. The produced specimen was first measured with a digital micrometer. After the first measurement, the specimen was immersed in a constant temperature water bath for 15 days, after which the second measurement was performed, and the third measurement was taken after 30 days. The measured values were analyzed using the independent sample t-test (α=0.05). Results: In the non-immersion water tank, the contraction was 0.9% in the 400 group and 1.3% in the 460 group. In the constant temperature bath, the expansion was high at -0.4% in the 400 group for 15 days, and the smallest expansion was -0.03% for the 400 group for 30 days. There were significant differences between the two groups (p<0.05). Conclusion: The 400 group had a lower UV resin specimen strain than the 460 group. Therefore, it is recommended to use the wavelength required by the UV-curing resin.

A COMPARATIVE STUDY OF WATER ABSORPTION AND RELATED CHANGES OF COMPRESSIVE STRENGTH IN THREE RESTORATIVE MATERIALS (치과용 수복재의 수분흡수도와 압축강도의 변화에 관한 연구)

  • Chang, Woo-Hyuck;Choi, Yeong-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.1
    • /
    • pp.161-170
    • /
    • 2003
  • The aesthetic restorative materials are widely used in recent dentistry, showed not only the different quality between each component but also showed that the environment of the material has important effect on the physical properties of the material. Especially, when the restoratives are restored in the mouth, and since saliva is existing, the restoratives are always exposed to water and affected by the saliva. The purpose of this study was to research and compare the change of the degree of water sorption after water immersion of three types of the resin-based materials and the compressive strength, and observe the relation between the change of the water absorbing degree and the compressive strength. Z-100(3M, U.S.A) as a composite resin, F-2000(3M, U.S.A) as a compomer and Vitremer Restoratives(3M, U.S.A) as a resin-modified GIC were used, and each specimen was made to measure the water sorption and to evaluate the compressive strength. The specimens for measurement of the water sorption and the compressive strength were divided into 4 groups(1 day, 2 weeks, 4 weeks, and 8weeks). Each specimen was filled in the 30cc vial with 20cc of distilled water during the fixed amount of period in $37^{\circ}C$. The water sorption is decided by dividing the difference of weight before and after the immersion by the volume, and the compressive strength was measured by using the instron after the immersion. The following results were obtained ; 1. The more the water sorption increased, the more the immersion period of three restorative materials was long. And the most of water sorption was obtained during the first 2 weeks(P<0.001). 2. The water sorption of resin-modified GIC was higher than composite resin and compomer. 3. The more the compressive strength decreased, the more the immersion period of three restorative materials increased(composite resin and compomer: P<0.001, resin-modified GIC: P<0.05). Especially, the amount of the reduction in compressive strength of the composite resin was the highest. 4. The more the water sorption of all materials increased, the more the compressive strength decreased(P<0.05).

  • PDF

Analysis of Ultrasonic Scattering from Side-drilled Holes (원주형 기공에 대한 초음파 산란 해석)

  • Jeong, Hyun-Jo;Park, Moon-Cheol
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.6
    • /
    • pp.559-565
    • /
    • 2004
  • Two different methods were used for the scattering analysis of side-drilled holes(SDH). The scattering models include an explicit model based on the Kirchhoff approximation and the solution of the exact separation of variables. The far-field scattering amplitude was calculated and their time-domain results were compared for the case of shear vertical wave. The exact solution predicts the existence of the creeping wave. The Kirchhoff approximation agreed to the exact solution, except the case of the creeping wave. Two measurement models were introduced to predict the response from the SDHs for the case of immersion, pulse-echo testing. The received voltage was calculated for the case of the shear vertical waves with the incident angle of $45^{\circ}$ to the SDH with the diameter of 1mm, and compared with the experimental results.

Virtual Reality Based Cultural Tourist Attractions converging with Souvenir (수베니어를 융합한 가상현실 기반의 문화 관광지 가상체험 서비스)

  • Lee, Ga-Yeon;Lee, Seok-hyun
    • Journal of Convergence for Information Technology
    • /
    • v.7 no.3
    • /
    • pp.111-116
    • /
    • 2017
  • This study offers the possibility as a new product of souvenirs from cultural tourist sites with virtual reality contents, instead of a simple exhibit. Users can watch augmented reality contents on souvenirs, and use the virtual experience service of cultural tourist sites with VR viewer. It has 4K-class high-quality $360^{\circ}$ image capture to increase the immersion of users in virtual space, implement virtual reality space and intuitive UI interaction with users using IMU (Inertial Measurement Unit). It is also possible to apply various add-on functions, including 3D contents, through technical development to increase its marketability, and apply in other industries. In addition, the prototype of the souvenir and VR viewer will be made by using a 3D printer and such in order to apply the contents which will be introduced in this study. Various product expansions can be considered through consultation with the relevant companies for the use of ready-made products.