• Title/Summary/Keyword: Measurement of Immersion

Search Result 122, Processing Time 0.024 seconds

Concentration Measurement of Alcohol Solution Using Immersion-Type On-Line Refractometer (침적식 온라인 굴절계를 이용한 알코올 농도의 측정)

  • 정옥진;김영한
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.6
    • /
    • pp.473-477
    • /
    • 2003
  • An immersion-type on-line refractometer useful for the in-situ measurement of chemical composition and temperature is developed, and its performance is examined by applying the refractometer to known alcohol solution having concentrations between 0 vol. % and 25 vol. %. Because refractive index and temperature are measured simultaneously, it is possible to compensate the effect of temperature for fast and direct measurement. The outcome of composition measurement for the different concentrations of alcohol solution indicates that the device is suitable for the chemical composition measurement by yielding stable and reproducible reading.

Proposal on Immersion Assessment of Interactive Art (인터랙티브 아트에서의 몰입측정 방법 제안)

  • Lee, MyounJae;Kim, Kyoung-Nam
    • Journal of Digital Convergence
    • /
    • v.12 no.9
    • /
    • pp.353-358
    • /
    • 2014
  • Interactive art is implemented by participants interaction, characterized by the virtuality, immersion, interactivity. Among these features, immersion is important factor to absorb in the interactive art. From now, Interactive art measurement methods are mainly used in interview, questionnaire, and physiological methods. But these methods are difficult to measure the exact immersion, can give interfere with viewer's participation in the interactive art. In this paper, we propose the immersion measurement method which based on participant's moving lines, observation time with mobile devices, camera. This paper can help to analyse degree of immersion on interactive art.

Uncertainty assessment of industrial platinum resistance thermometers for different lead-wire connection methods (산업용 백금저항온도센서의 결선방식에 따른 측정불확도 평가방법)

  • Kim, Yong-Gyoo;Gam, Kee-Sool;Yang, In-Seok
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.322-326
    • /
    • 2009
  • To estimate the measurement uncertainty for industrial platinum resistance thermometers(IPRTs) made with 3-wire connection, the immersion temperature profile was investigated using a liquid bath. Two types of IPRTs having lead wires made of silver and nickel were constructed and the immersion profiles were measured at temperatures from -50 $^{\circ}C$ to 250 $^{\circ}C$ using 3-wire and 4-wire method. As immersion depth and temperature increased, the resistances measured by 3-wire method increased linearly but not for 4-wire method. To calibrate a 3-wire IPRT, the immersion effect must be accounted for. We propose a linear equation to assess correctly the measurement uncertainty.

Salinity Determination for Sea Water Using Immersion-Type On-Line Refractometer (침적식 온라인 굴절계를 이용한 해수의 염도 측정)

  • Kim, Byoung-Chul;Kim, Young-Han;Chan, Sang-Mok
    • Journal of Navigation and Port Research
    • /
    • v.26 no.5
    • /
    • pp.571-575
    • /
    • 2002
  • An immersion-type on-line refractometer useful for the in-situ measurement of salinity and temperature of sea water is developed, and its performance is examined by applying the refractometer to known salt solution having salt concentration between 2 and 4 % similar to practical sea water salinity. Since refractive index and temperature are measured simultaneously, it is possible to compensate the effect of temperature for fast and direct measurement. The outcome of salinity measurement for the different concentrations of salt solution indicates that the device is suitable for the salinity measurement by yielding stable and reproducible reading.

Poisson's Ratio Scanning Using Immersion Ultrasonic Testing

  • Oh, Seo-Young;Kim, Young-H.;Shin, Yo-Sub;Cho, Hyun-Joon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.6
    • /
    • pp.519-523
    • /
    • 2008
  • Poisson's ratio is one of elastic constants of elastic solids. However, it has not attracted attention due to its narrow range and difficult measurement. Transverse wave velocity as well as longitudinal wave velocity should be measured for nondestructive measurement of Poisson's ratio. Hard couplant for transverse wave prevents transducer from scanning over specimen. In the present work, a novel measurement of Poisson's ratio distribution was proposed. Immersion method was employed for the scanning over the specimen. Echo signals of normal beam longitudinal wave were collected. Transverse wave modes generated by mode conversion were identified. From transit time of longitudinal and transverse waves, Poisson's ratio can be determined without information of specimen thickness. This technique was demonstrated for aluminum and steel specimens.

Electrical Characteristics Test of Distribution Polymer Lightening Arresters (배전용 폴리머 피뢰기의 전기적 특성시험)

  • Kwon, Tae-Ho;Lee, Byung-Sung;Song, Il-Keun;Kim, Dong-Myung;Yoon, Tae-Sang;Jung, Sang-Bong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.546-549
    • /
    • 2004
  • This paper describes the electrical characteristics of the polymer lightning arresters(L.As) used to protect distribution lines and power facilities from surge. For the relative comparison, the characteristics assessment was done for 2 states of L.As before and after water immersion treatment. The L.As for the comparative test were immersed with water of $95[^{\circ}C]$ considered a severe condition. After the immersion treatment, the assessment was carried out for material analyses in chemical structure(FTIR : fourier transform infrared spectrophotometer). Electrical performance measured insulation resistance measurement, leakage current measurement, critical operation voltage measurement etc.. In addition to, the results were compared with those for the L.As deteriorated in the field. Thus, the accelerative deterioration degree of polymer materials by immersion treatment was evaluated, by which the structural defects of the polymer L.As could be inferred.

  • PDF

Analysis of Immersive Game Contents Based on Storytelling: Focusing on VR Games (스토리텔링 기반 실감형 게임콘텐츠의 몰입감 분석: VR게임을 중심으로)

  • Song, Seungyeol;Lim, Sang Guk
    • Journal of Korea Multimedia Society
    • /
    • v.25 no.6
    • /
    • pp.844-851
    • /
    • 2022
  • This study intends to propose an evaluation tool for analyzing the sense of immersion of realistic VR game contents in the metabus game industry, which is rapidly increasing recently. This paper presents an analysis tool to measure the degree of immersion after selecting three types VR games for research, and analyzing the immersion way method of the game. The research method analyzes how the user and the sense of immersion formed in the storytelling in the game can have an effect. Based on the results, we present an sense of immersion analysis and measurement method for evaluating the usability of VR game contents, which is a key element in the metaverse era. Furthermore, it expands the immersion element that appears in storytelling to the game industry and seeks a new direction of development through connection with the VR game industry.

Effect of measurement method and cracking on chloride transport in concrete

  • Zhang, Shiping;Dong, Xiang;Jiang, Jinyang
    • Computers and Concrete
    • /
    • v.11 no.4
    • /
    • pp.305-316
    • /
    • 2013
  • This paper aims to study the effect of measurement methods and cracking on chloride transport of concrete materials. Three kinds of measurement methods were carried out, including immersion test, rapid migration test and steady-state migration test. All of these measurements of chloride transport show that chloride ion diffusion coefficient decreased with the reduction of water to cement ratio. Results of the immersion test were less than that of rapid migration test and steady-state migration test. For the specimen of lower water to cement ratio, the external electrical field has little effect on chloride binding relatively. Compared with the results obtained by these different measurement methods, the lower water to cement ratio may cause smaller differences among these different methods. The external voltage can reduce chloride binding of concrete, and the higher electrical field made a strong impact on the chloride binding. Considering the effect of high voltage on the specimen, results indicate that results based on the steady-state migration test should be more reasonable. For cracked concrete, cracking can accelerate the chloride ion diffusion.

A Study on the Temperature Accuracy due to Conditions of Thermocouple Installation (열전대의 설치상태에 따른 온도측정 오차에 관한 연구)

  • 선양래
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.6 no.1
    • /
    • pp.49-54
    • /
    • 1982
  • In the equipments of industrial plant and marine engine, an exact temperature measurement is indispensable. Temperature measurement errors are induced by electrical and heat errors, and the insufficient immersion length of thermowell exerts an important effect to the haet error. In this paper, the author analyses the relation between temperature errors and the rate of immersion length to outside diameter (L/D) in order to reduce the heat errors.

  • PDF

In-process Immersion Ratio Estimation Using Spindle Motor Current during Face Milling (정면밀링공정중 추축모터전류를 이용한 절입비의 실시간 추정)

  • 조규진;오영탁;권원태;주종남
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.9 no.6
    • /
    • pp.57-64
    • /
    • 2000
  • In order to regulate cutting torque in milling, monitoring system should be set to a certain threshold. Radial immersion ratio is an important factor to determine the threshold and should be estimated in process for automatic regulation. In this paper, on-line estimation of the radial immersion ratio using spindle motor current in face milling is presented. When a tooth finishes sweeping, a sudden drop of cutting torque occurs. This torque drop is equal to the cutting torque acting on a single tooth at the swept angle of cut and can be acquired from cutting torque signals. Average cutting torque per revolution can also be calculated from cutting torque signals. The ratio of cutting torque acting on a single tooth at the swept angle of cut to the average cutting torque per revolution is a function of the swept angle of cut and the number of teeth. Using the magnitude of this ratio, the radial immersion ratio is estimated. Identical algorithm is adopted to estimate the immersion ratio based on the spindle motor current measurement. The experiments performed under different cutting conditions show that the radial immersion ratio can be estimated within 10% error range by the proposed method using spindle motor current. Varying immersion ratio is also estimated well using the presented algorithm.

  • PDF