• 제목/요약/키워드: Measurement conditions

검색결과 3,637건 처리시간 0.033초

반추동물 신증의 조기진단을 위한 뇨효소 측정법 1. 효소활성도 측정을 위한 적합한 조건과 정상범위에 관하여 (Measurement of Urine Enzymes for the Early Diagnosis of Nephrosis in Ruminants 1. Optimal Conditions for Measurement of Enzyme Activities and Normal Ranges)

  • 이창우;이경갑
    • 한국임상수의학회지
    • /
    • 제6권2호
    • /
    • pp.291-305
    • /
    • 1989
  • Present experiment was performed to establish the optimal reaction conditions for measurement of urinary gamma-glutamyltranspeptidase(${\gamma}$-GTP), N-acetyl-${\beta}$-D-glucosaminidase (AGS) and alanine aminopeptidase(AAP) activities in bovine and to investigate in vitro stability of the enzymes, within-run imprecision of the methods, and normal ranges. 1. The optimal wavelength for measurement of ${\gamma}$-GTP activity was 545nm. 2. The optimal pH of Tris-HCI buffer containing glycylglycine for measurement of urinary ${\gamma}$-GTP activity was 7.6~7.8(37$^{\circ}C$). 3. Coefficient of variance for within-run imprecision of urinary ${\gamma}$-GTP activity ranged from 4.8 to 7.2% and there was no significant difference among replications, 4. The optimal wavelength for measurement of urinary AGS activity was 405nm. 5. The optimal pH of citrate buffer for measurement urinary of AGS activity was 4.0(37$^{\circ}C$). 6. Coefficient of variance for within-run imprecision of urinary AGS activity ranged from 3.9 to 6.1% and there was no significant difference among replications. 7. The optimal wavelength for measurement of urinary AAP activity was 400nm. 8. The optimal pH of phosphate buffer for measurement of urinary AAP was 7.8. 9. Coefficient of variance for within-run imprecision of urinary AAP activity ranged from 2.5 to 4.8% and there was no significant difference among replications. 10. ${\gamma}$-GTP and AGS activities were increased significantly by gel-filtration. 11. Turbidity interfered with measurement of urinary AAP activity in bovine unless the specimen was gel-filterated. 12. Preservation of the specimen at 5$^{\circ}C$ or -20$^{\circ}C$ did not affect the AGS activity at least for 7 days after collection. 13. Preservation of the specimen at 5$^{\circ}C$ or 20$^{\circ}C$ did not affect the ${\gamma}$-GTP and AAP activities statistically, but some individual specimens revealed fluctuation during preservation. 14. ${\gamma}$-GTP, AGS and AAP activities revealed fluctuation by the tine of the day when the specimen was collected. 15. The normal ranges of urinary ${\gamma}$ -GTP, AGS and AAP activities were 6.60${\pm}$3.26(2.36-14.50), 1.31 ${\pm}$ 0.81(0.33-3.78), and 1.73 ${\pm}$ 0.55(0.77-3.03)U/l. respectively.

  • PDF

농기계의 등화장치가 운전자의 야간시인성에 미치는 영향 (Effect of Agricultural Machine Lighting systems on Drivers Night Visibility)

  • 최승현;이성렬;장택영;도명식
    • 한국ITS학회 논문지
    • /
    • 제16권4호
    • /
    • pp.25-35
    • /
    • 2017
  • 본 연구는 야간 시간대의 농기계 주행시 등화장치 장착여부에 따른 운전자의 야간시인성분석을 목표로 하였다. 야간시인성 분석을 위해 등화장치에 대한 휘도측정실험과 안구운동측정기기를 활용한 주시시간측정실험을 수행하였다. 휘도측정실험결과, 농기계와의 상대거리가 가까워지며 등화장치의 상태가 양호해질수록 휘도 값이 증가하는 것으로 나타났다. 또한, 주시시간측정실험에서는 주행속도에 상관없이 등화장치의 상태가 양호해질수록 농기계에 대한 총 주시시간이 증가하는 것으로 나타났다. 연구결과, 농기계에 등화장치를 장착할 경우 농기계에 대한 운전자의 야간 시인성이 향상되어 농기계사고의 예방에 큰 도움을 줄 수 있을 것으로 기대된다.

주행조건에 따른 판형교 지점부 거동 측정 분석 (Measurement and Analysis about Behavior of Steel Plate Girder in Vicinity of Support, According to Driving Condition)

  • 이승열;김남홍;우병구;나강운
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.690-696
    • /
    • 2011
  • A number of conventional railway bridge is more than 2600. Non-ballast plate girder bridge is about 700 and this is 27% of all bridge numbers. Non-ballast plate girder has advantages that self load is more lighter than moving load and construction cost is more inexpensive than concrete bridge. But non-ballast plate girder has disadvantages that vibration and noise is bigger than concrete bridge. This study had analyzed behavior of non-ballast plate girder according to the arrangement of supports and driving conditions to review the proper arrangement of support. Measurements were performed in single line and disel locomotive of 7400type were used as test vehicle. The vehicle's driving conditions are as follows; Change of driving direction, Constant speed driving, Deceleration driving, Acceleration driving. Main measurement contents were horizontal displacement and vertical vibration acceleration in girder of vicinity support. Results of measurement are as follows; In case that a vehicle drives from fixed support to movable support, vertical vibration acceleration of the girder was smaller than opposition case.

  • PDF

선로변 전차선과 조가선의 전류를 이용한 집전성능 분석 기술 (Analysis of Current Collection Performance using Real-time Measurement of Current for Overhead Contact Line on the Track-side)

  • 박영;신승권;이기원;김재문;김원하
    • 전기학회논문지
    • /
    • 제62권4호
    • /
    • pp.573-576
    • /
    • 2013
  • In this paper, analysis method for current collection performance based on real-time current of catenary system is proposed. An innovative method based on track-side of railway system is used for measurement of currents for overhead contact line during the collection with pantograph. The evaluation of a qualitative ratio for current collection performance were conducted using proposed algorithm under various conditions such as laboratory and track-side. To check the validity of our approach, we compared between calculation results from current of contact wire and measurement results from arcing of pantograph using simulator in laboratory conditions. The results show that the behavior of current collection performance were analysis from currents of overhead contact line in AC electric railway system.

Micro PIV 를 기반한 혈액 점도 측정 기법 (Microfluidic Method for Measurement of Blood Viscosity based on Micro PIV)

  • 홍현지;정미림;염은섭
    • 한국가시화정보학회지
    • /
    • 제15권3호
    • /
    • pp.14-19
    • /
    • 2017
  • Increase of blood viscosity significantly changes the flow resistance and wall shear stress which are related with cardiovascular diseases. For measurement of blood viscosity, microfluidic method has proposed by monitoring pressure between sample and reference flows in the downstream of a microchannel with two inlets. However, it is difficult to apply this method to unknown flow conditions. To measure blood viscosity under unknown flow conditions, a microfluidic method based on micro particle image velocimetry(PIV) is proposed in this study. Flow rate in the microchannel was estimated by assuming velocity profiles represent mean value along channel depth. To demonstrate the measurement accuracy of flow rate, the flow rates measured at the upstream and downstream of a T-shaped microchannel were compared with injection flow rate. The present results indicate that blood viscosity could be reasonably estimated according to shear rate by measuring the interfacial width and flow rate of blood flow. This method would be useful for understanding the effects of hemorheological features on the cardiovascular diseases.

전자부품의 방열방향에 따른 접촉열전도 특성 (Characterization of a Thermal Interface Material with Heat Spreader)

  • 김정균;;이선규
    • 한국정밀공학회지
    • /
    • 제27권1호
    • /
    • pp.91-98
    • /
    • 2010
  • The increasing of power and processing speed and miniaturization of central processor unit (CPU) used in electronics equipment requires better performing thermal management systems. A typical thermal management package consists of thermal interfaces, heat dissipaters, and external cooling systems. There have been a number of experimental techniques and procedures for estimating thermal conductivity of thin, compressible thermal interface material (TIM). The TIM performance is affected by many factors and thus TIM should be evaluated under specified application conditions. In compact packaging of electronic equipment the chip is interfaced with a thin heat spreader. As the package is made thinner, the coupling between heat flow through TIM and that in the heat spreader becomes stronger. Thus, a TIM characterization system for considering the heat spreader effect is proposed and demonstrated in detail in this paper. The TIM test apparatus developed based on ASTM D-5470 standard for thermal interface resistance measurement of high performance TIM, including the precise measurement of changes in in-situ materials thickness. Thermal impedances are measured and compared for different directions of heat dissipation. The measurement of the TIM under the practical conditions can thus be used as the thermal criteria for the TIM selection.

자동 보정형 디지털 제어기 설계에 관한 연구 (A Study on the Design of Digital Controllers with Automatic Calibration)

  • 나승유;박민상
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1998년도 추계종합학술대회 논문집
    • /
    • pp.413-416
    • /
    • 1998
  • Sensitivity and calibration considerations are most important in the design and implementation of real control systems. Ideally parameter changes due to various causes should not appreciably affect the system's performances. But all the values of physical components of the plants and controllers as well as the relevant environmental conditions change in time, thus the output performance can be deteriorated during the operating span of the system. Naturally the duty of calibration or the prevention of performance deterioration due to excessive component sensitivity should be provided to the control system. In this paper, we propose a digital controller which has the capability of calibration and gain adjustment as well as the execution of control law. Specifically the problems of gain adjustment and offset calibration in the light source and CdS sensor module for position measurement in a flexible link system are considerably resolved. The parameters of measurement module are prone to change due to environmental brightness conditions resulting in poor steady state performance of the overall control system. Thus a proper method is necessary to provide correction to the changed values of gain and offset in the position measurement module. The proposed controller, whenever necessary, measures the open-loop characteristics, andthen calculates the offset and sensor gain correction values based on the prepared standard measurements. It is applied to the control of a flexible link system with the gain and offset calibration porblems in the light sensor module for position to show the applicability.

  • PDF

다구찌 방법에 의한 유리-실리콘 양극접합 계면의 파괴인성치 측정 및 양극접합공정 조건에 따른 접합강도 분석 (Measurement of Glass-Silicon Interfacial fracture Toughness and Experimental Evaluation of Anodic Bonding Process based on the Taguchi Method)

  • 강태구;조영호
    • 대한기계학회논문집A
    • /
    • 제26권6호
    • /
    • pp.1187-1193
    • /
    • 2002
  • Anodic bonding process has been quantitatively evaluated based on the Taguchi analysis of the interfacial fracture toughness, measured at the interface of anodically bonded silicon-glass bimorphs. A new test specimen with a pre-inserted blade has been devised for interfacial fracture toughness measurement. A set of 81 different anodic bonding conditions has been generated based on the three different conditions for four different process parameters of bonding load, bonding temperature, anodic voltage and voltage supply time. Taguchi method has been used to reduce the number of experiments required for the bonding strength evaluation, thus obtaining nine independent cases out of the 81 possible combinations. The interfacial fracture toughness has been measured for the nine cases in the range of 0.03∼6.12 J/㎡. Among the four process parameters, the bonding temperature causes the most dominant influence to the bonding strength with the influence factor of 67.7%. The influence factors of other process parameters, such as anodic voltage and voltage supply time, bonding load, are evaluated as 18%, 12% and 2.3%, respectively. The maximum bonding strength of 7.23 J/㎡ has been achieved at the bonding temperature of 460$\^{C}$ with the bonding load of 45gf/㎠, the applied voltage of 600v and the voltage supply time of 25minites.

Continuous deformation measurement for track based on distributed optical fiber sensor

  • He, Jianping;Li, Peigang;Zhang, Shihai
    • Structural Monitoring and Maintenance
    • /
    • 제7권1호
    • /
    • pp.1-12
    • /
    • 2020
  • Railway tracks are the direct supporting structures of the trains, which are vulnerable to produce large deformation under the temperature stress or subgrade settlement. The health status of track is critical, and the track should be routinely monitored to improve safety, lower the risk of excess deformation and provide reliable maintenance strategy. In this paper, the distributed optical fiber sensor was proposed to monitor the continuous deformation of the track. In order to validate the feasibility of the monitoring method, two deformation monitoring tests on one steel rail model in laboratory and on one real railway tack in outdoor were conducted respectively. In the model test, the working conditions of simply supported beam and continuous beam in the rail model under several concentrated loads were set to simulate different stress conditions of the real rail, respectively. In order to evaluate the monitoring accuracy, one distributed optical fiber sensor and one fiber Bragg grating (FBG) sensor were installed on the lower surface of the rail model, the strain measured by FBG sensor and the strain calculated from FEA were taken as measurement references. The model test results show that the strain measured by distributed optical fiber sensor has a good agreement with those measured by FBG sensor and FEA. In the outdoor test, the real track suffered from displacement and temperature loads. The distributed optical fiber sensor installed on the rail can monitor the corresponding strain and temperature with a good accuracy.

텔레매틱스 서비스를 위한 차량 내 2.4GHz 대역의 근거리 무선 통신 환경 측정 시스템 구현 (2.4GHz Short range Wireless Surroundings Measurement system within In-Vehicle environment for Telematics service)

  • 허수정;이승환;박용완;신정훈
    • 대한임베디드공학회논문지
    • /
    • 제1권2호
    • /
    • pp.82-89
    • /
    • 2006
  • It appears that it is possible for us to make a wireless communication of even home-network system within car by integrating with the Ubiquitous such as mobile phone, wireless Internet, GPS and DMB in the future. If the present wireless surroundings within the car are connected with very high-speed wireless network as measurement system for wireless communication surroundings within this car in the future, it will develop the complicated communication conditions such as safe checkup, communication between systems within car, and wireless communication for user entertainment unlike universal communication conditions. Accordingly, there is the necessity of the device that can measure the interference of electric wave, communication speed and communication quality by a kind of each car. This paper aims at making the real measurement device to raise the reliability of each Application for inquiring into the interference about each other in the frequency band used under Telematics surroundings.

  • PDF