• 제목/요약/키워드: Measurement conditions

검색결과 3,637건 처리시간 0.027초

잔향실법 흡음률 측정에 미치는 확산체의 영향 (The effect of diffusers on the measurement of sound absorption in a reverberation room)

  • 한희갑;김경호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.1194-1197
    • /
    • 2006
  • Recently, international standard for measurement of sound absorption in a reverberation room has been amended. In the revised version, temperature, humidity and air pressure conditions are strictly restricted and also the concrete procedures are presented to reduce the differences in test results by adding inspection of diffusion, measurement uncertainty etc. In this paper, the systematic tests are conducted based on the inspection guide of diffusion defined by ISO 354 and the effects of diffusers on the measurement of sound absorption ratio are considered. As a result, we perceived that the averaged sound absorption ratio in mid and high frequency range is expected to measure around $0.05{\sim}0.1$ higher in high sound absorption material. Therefore, as for the reverberation room for measurement of sound absorption, we need to take into consideration not only the spatial standard deviation of sound pressure mandated by ISO 3741, but also, inspection regulation of diffusion showed by ISO 354.

  • PDF

미소입자영상유속계를 이용한 굴절률이 다른 두 유체 유동 측정 (Micro PIV Measurement of Two-Fluid Flow with Different Refraction Indices)

  • 김병재;유임정;성형진
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2003년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.107-114
    • /
    • 2003
  • The influence of property difference in refraction index on micro PIV measurement of two-fluid flow in a microchannel was analyzed. The difference of measurement planes in two fluids would bring misunderstanding of the physics. The objective-imaging system for two-fluid flow measurement was presented, and the condition for measurement of valid velocity profile across two-fluid interface was derived. A micro PIV experimental system was set up to measure two-fluid flow inside a Y-shape microchannel. Under the conditions, three cases of two-fluid flow of glycerol solutions at different concentration (${\phi}$), e.g., (${\phi}=0\;and\;{\phi}=0.2,\;{\phi}=0.1\;and\;{\phi}=0.5,\;{\phi}=0\;and\;{\phi}=0.6$, were measured. Close agreement of experimental and numerical results was found.

  • PDF

항공기 형상에 대한 근전계 RCS 측정에서 내삽 알고리즘을 이용한 측정시간 단축에 대한 분석 (An Analysis on the Reduction of Measurement Time Using Interpolation Algorithm in Near-field RCS Measurements for Aircraft Shape)

  • 박호민
    • 한국군사과학기술학회지
    • /
    • 제25권4호
    • /
    • pp.339-346
    • /
    • 2022
  • The importance of stealth technology is increasing in modern warfare, and Radar Cross Section(RCS) is widely used as an indicator of stealth technology. It is useful to measure RCS using an image-based near-field to far-field transformation algorithm in short-range monostatic conditions. However, the near-field measurement system requires a longer measurement time compared to other methods. In this work, it is proposed to reduce the measured data using an interpolation method in azimuth angular domain. The calculated far-field RCS values according to the sampling rate is shown, and the performance of the algorithm applied with interpolation in the angular domain is presented. It is shown that measurement samples can be reduced several times by using the redundancy in the angular domain while producing results similar to the conventional method.

기둥형 로드셀 감지부의 설계변수에 따른 비선형 거동해석 (Finite Element Analysis of Nonlinear Behavior of a Column Type Sensing Element for Load Cell According to Design Parameters)

  • 이춘열;강대임
    • 대한기계학회논문집A
    • /
    • 제24권6호
    • /
    • pp.1540-1546
    • /
    • 2000
  • Recently, force measurement systems are commonly used in many industrial fields and the precision of the measurement system is getting more important as the industry needs more precise tools and in struments to make high quality products. However, a high precision force measurement system is hard to make unless we know precisely the causes, quality and quantity of measurement errors in advance. In this work, many possible mechanical causes of measurement errors are reviewed including ratio of length to diameter of sensing part, radius of contact area, radius of bearing part, ratio of material properties and change of boundary conditions. Also, the measurement errors are analyzed by nonlinear finite element method and the nonlinear behavior of the errors are investigated. The results can be used to design force measurement systems and expected to be very useful especially for compact type load cells.

Local Flow Speed Measurement Using Tunable AC Thermal Anemometry

  • Chung Won Seok;Kwon Ohmyoung;Lee Joon Sik;Choi Young Ki;Park Seungho
    • Journal of Mechanical Science and Technology
    • /
    • 제19권7호
    • /
    • pp.1449-1459
    • /
    • 2005
  • This paper shows the results of local flow speed measurement using tunable AC thermal anemometry, which is suitable for the accurate measurement of wide range flow speed. The measurement accuracy is verified through the comparison between the measurement data and the analytic solution of the sensor temperature oscillation in stationary fluid. The relation between the phase lag and the flow speed is experimentally investigated at various conditions. The measurement sensitivity for low flow speed improves in a low frequency region and that for high flow speed improves in a high frequency region. Also, the sensitivity increases with decreasing thermal conductivity of the surrounding fluid. The local flow speed could be measured as low as 1.5 mm/s and the highest measurement resolution was 0.05 mm/s in the range of 4.5 $\~$5.0 mm/s at 1 Hz in this experiment.

도시주거수준의 변화추이 분석 - 1945년 이후 서울을 중심으로 - (An Analysis of the Changes of Urban Housing Conditions in Korea since 1945)

  • 박정희
    • 한국주거학회논문집
    • /
    • 제2권1호
    • /
    • pp.77-92
    • /
    • 1991
  • This study is to investigate urban housing conditions in Seoul since 1945. The purposes of this study is to analyze the changes of housing conditions and the gap of average housing conditions and the housing norms longitudinally.For those purposes, the indicators that present the housing conditions are introduced, and the changes of average housing conditions are analyzed by social class, using Population and Housing Census and relateddata. Korean urban housing conditions has been better since 1970s in the aspect of quality. It is, however, relatively much worse than that of developed countries. The gap of housing conditions among social classes is large, especially in qualitative indicators, density and housing facilities. Comparing it with housing norm(as an ideal measurement), it is much worse.

  • PDF

마이크로웨이브를 이용한 콘크리트 잔골재 표면수율 측정 자동화 (Microwave Moisture Measurement of Fine Aggregate in RMC Industry)

  • 최영철;이봉춘;문규돈;손영정
    • 한국안전학회지
    • /
    • 제27권1호
    • /
    • pp.63-69
    • /
    • 2012
  • Ready-mixed concrete(RMC) has been a major construction materials for infrastructures. However, RMC with poor quality is reported to be social issue since it directly user's safety and convenience. Because the properties of concrete as a construction material are greatly influenced by the variation of water content, to control water accurately is the most efficient method for the quality control in RMC industry. In this study, the automatic measurement technology of fine aggregate was developed by using the microwave moisture measurement. For the various conditions of fine aggregate such as moisture, temperature and pressure, the calibration curve of moisture measurement was obtained by using oven-dry method. From the infield and outfield test, it can be obtained that the accuracy of microwave moisture measurement is very high and the automatic system of microwave moisture measurement is very convenient and useful for quality control in RMC Industry.

레이저 변위계를 이용한 암석 절리면의 3차원 거칠기 측정기 개발 (Development of a 3D Roughness Measurement System of Rock Joint Using Laser Type Displacement Meter)

  • 배기윤;이정인
    • 터널과지하공간
    • /
    • 제12권4호
    • /
    • pp.268-276
    • /
    • 2002
  • In this study, a 3D coordinate measurement system equipped with a laser displacement meter for digitizing rock joint surface was established and the digitized data were used to calculate several roughness parameters. The parameters used in this study were micro avenge inclination $angle(i_{ave})$, average slope of joint $asperity(SL_{ ave})$, root mean square of $i-angle(i_{rms})$, standard deviation of height(SDH), standard deviation of $i-angle(SD_i)$, roughness profile $index(R_P)$, and fractal dimension(D). The relationships between the roughness parameters based on the digitzation of the surface profile were analyzed. Since the measured value varied according to the degree of reflection and the variation of colors at the measuring point, rock joint surface was painted in white to minimize the influence of the surface conditions. The comparison of the measured values and roughness parameters before and after painting revealed the better consequence from measurement on the painted surfaces. Also, effect of measuring interval was studied. As measured interval was increased, roughness parameters were exponentially decreased. The incremental sequence of degree of decrease was $SDH\; i_{ave},\; i_{rms},\; SD_i,\;and\; R_ p-1$. As a result of comparison of parameters from pin-type measurement system and laser type measurement system, all value of parameters were higher when laser-type measurement system was used, except SDH.

대규모 건물의 기밀성능 측정기준 수립에 관한 연구 (Study on the Establishment of Large Building Airtightness Measurement Standards)

  • 이동석;지경환;조재훈
    • 한국태양에너지학회 논문집
    • /
    • 제34권1호
    • /
    • pp.117-124
    • /
    • 2014
  • Airtightness standards using fan pressurization method are normally used for measuring small buildings, detached houses, and apartment units. And, it is easy to conduct airtightness measurement through this fan pressurization method. However, it can be difficult to achieve accurate measurement results for the large buildings as the height and volume of the buildings have been increased. In this paper, we studied the principle of airtightness method by fan pressurization. And, we reviewed the measurement process described in ISO 9972, EN 13829, ASTM E779, ATTMA TS 1, CAN/CGSB 149.15, and JIS A 2201. Then, we categorized the methods' items according by air flow rate (Q) and pressure difference(${\Delta}P$). As a result, we made a comparison analysis on the measurement methods appeared in each standards. And, we achieved 5 test conditions about air flow rate and pressure difference to state requirements for large buildings airtightness measurement.

Type 1 Study, Gage R&R Study와 ISO 22514-7의 측정능력지수 간 연관성 분석 (Some Relationships between Measurement Capability Indices of Type 1 Study, Gage R&R Study, and ISO 22514-7)

  • 이승훈;임근
    • 품질경영학회지
    • /
    • 제44권1호
    • /
    • pp.77-94
    • /
    • 2016
  • Purpose: This paper reviews Type 1 Gage study, Gage R&R study, and procedure of ISO 22514-7 for assessing a measurement system, and discusses some relationships between the measurement capability indices. Methods: The gage capability index $C_g$ of Type 1 Gage study, precision-to-tolerance ratio PTR of Gage R&R study, and measurement performance ratio $Q_{MS}$ and $Q_{MP}$ of ISO 22514-7 are considered in this paper. Results: This paper derives the relationships between $C_g$ and $Q_{MS}$, PTR and $Q_{MP}$, and $Q_{MS}$ and $Q_{MP}$, respectively, and discusses the acceptance conditions for each procedures. Conclusion: The measurement capability analysis is the first step for the quality improvement of the manufacturing processes. Therefore the result of this study provides a helpful guidelines for assessing the measurement system, enabling proper evaluation of manufacturing processes.