• Title/Summary/Keyword: Measurement and assessment

Search Result 1,988, Processing Time 0.028 seconds

Uncertainty assessment for a towed underwater stereo PIV system by uniform flow measurement

  • Han, Bum Woo;Seo, Jeonghwa;Lee, Seung Jae;Seol, Dong Myung;Rhee, Shin Hyung
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.10 no.5
    • /
    • pp.596-608
    • /
    • 2018
  • The present study aims to assess test uncertainty assessment method of nominal wake field measurement by a Stereoscopic Particle Image Velocimetry (SPIV) system in a towing tank. The systematic uncertainty of the SPIV system was estimated from repeated uniform flow measurements. In the uniform flow measurement case, time interval between image frames and uniform flow speed were varied to examine the effects of particle displacement and flow around the SPIV system on the systematic standard uncertainty. The random standard uncertainty was assessed by repeating nominal wake field measurements and the estimated random standard uncertainty was compared with that of laser Doppler velocimetry. The test uncertainty assessment method was applied to nominal wake measurement tests of a very large crude oil carrier model ship. The nominal wake measurement results were compared with existing experimental database by other measurement methods, with its assessed uncertainty.

A Measurement and Analysis of Low Level Radiated-Noise Using Vertical Line Array (수직선배열을 이용한 저소음 함정음향 측정 및 분석기법)

  • Choi, Jae-Yong;Son, Kweon;Dho, Kyeong-Cheol
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.6 no.2
    • /
    • pp.55-64
    • /
    • 2003
  • Underwater acoustic noise measurement is an essential element for vulnerability assessment of modern naval platforms. But during the last few decades environmental conditions have drastically changed due to the gradually increasing sea ambient noise level and decreasing submarine radiated noise level. A real-time underwater acoustic measurement system with vertical line array is designed for the quiet submarine radiated noise assessment in challenging environment. This system has a constant directivity index in measurement frequency range and accurate tracking capability for the transmission loss compensation and navigation aids inside the submarine. This system has been validated at sea and used several times for the submarine noise measurement.

A Systematic Review on Measurement Instruments of Bilateral Upper Extremity Function (양측 상지 기능 평가도구에 관한 체계적 고찰)

  • Lee, Joo-Hyun;Lee, Ye-Jin;Park, Ji-Hyuk
    • Therapeutic Science for Rehabilitation
    • /
    • v.5 no.1
    • /
    • pp.7-22
    • /
    • 2016
  • Objective : This study was conducted to review about instrument for bilateral upper extremity assessment. Methods : We searched published papers in Medline database. The keywords used in the search were 'upper extremity' and 'motor activity', 'activities of daily living' and 'assessment', 'instrument', 'disability evaluations'. In total of 68 papers, 44 assessment instruments was extracted. We analyzed about numbers, subjects, methods, reliability, validity, responsiveness of assessment instruments about bilateral upper limb function comparing unilateral, combined bilateral and unilateral instruments. Results : The numbers of bilateral measurement tool were 2 in a total of upper extremity measurement tools. Also, subjects were patients with stroke and measurement was based on performance. The reliability, validity and responsiveness of tools were high. Conclusions : Futher study will be needed to development and research about instrument of bilateral upper extremity.

Assessment on shock pressure acquisition from underwater explosion using uncertainty of measurement

  • Moon, Seok-Jun;Kwon, Jeong-Il;Park, Jin-Woo;Chung, Jung-Hoon
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.9 no.6
    • /
    • pp.589-597
    • /
    • 2017
  • This study aims to verify experimentally the specifications of the data acquisition system required for the precise measurement of signals in an underwater explosion (UNDEX) experiment. The three data acquisition systems with different specifications are applied to compare their precision relatively on maximum shock pressures from UNDEX. In addition, a method of assessing the acquired signals is suggested by introducing the concept of measurement uncertainty. The underwater explosion experiments are repeated five times under same conditions, and assessment is conducted on maximum quantities acquired from underwater pressure sensors. It is confirmed that the concept of measurement uncertainty is very useful method in accrediting the measurement results of UNDEX experiments.

A Study on the Compliance of the Occupational Safety and Health Act by Busan and Gyungsangnam-do Province Working Environment Measurement Institutions (부산·경남지역 작업환경측정기관의 산업안전보건법 준수 실태 및 준수율 제고를 통한 측정기관 종사자 건강보호 방안 고찰)

  • Lee, Hyunseok
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.31 no.4
    • /
    • pp.440-450
    • /
    • 2021
  • Objectives: This study aims to investigate whether working environment measurement institutions(WEMIs) are conducting safety and health education, risk assessment, and oversight of special management materials, and whether working environment measurement and special medical examinations are being conducted as prescribed in the Occupational Safety and Health Act(OSHA). Methods: In of February 2021, a questionnaire was prepared and distributed to 33 WMEIs registered with the Ministry of Employment and Labor(MoEL) in Busan and Gyeongsangnam-do Province. The responses were collected and then analyzed. Results: The findings show that 5 WEMIs(15%) complied fully with OSHA. Risk assessment was conducted by 13 WMEIs(39%) and safety education by 11 WMEIs(33%). Eighteen WMEIs(55%) conducted working environment measurement, and 29 WMEIs(88%) conducted special medical examinations. The implementation rate of the risk assessment in the health industry(85%) was higher than the one in the special technology industry(11%)(p<0.05). The implementation rate of the special medical examination in the examiners(54%) was not as high as the one in the analysts(91%)(p<0.05). Conclusions: The MoEL needs to check whether basic OSHA requirements are being observed during regular inspections by WEMIs. These findings indicate that it is necessary to prepare a plan to improve the rate of compliance with OSHA regulations.

Design of Screening Inspection Procedures Based on Guard Bands Considering Measurement Errors (측정오류를 고려한 가드밴드 기반 스크리닝 검사방식의 설계)

  • Kim, Young Jin
    • Journal of Korean Society for Quality Management
    • /
    • v.41 no.4
    • /
    • pp.673-681
    • /
    • 2013
  • Purpose: The purpose of this study is to investigate the design optimization modeling of screening procedures based on the assessment of misclassification errors. Methods: Misclassification errors due to measurement variability are derived for normally distributed quality characteristics. Further, an optimization model for ensuring the level of outgoing quality is proposed and demonstrated through an illustrative example. Results: It is shown that two types of misclassification errors (i.e., false acceptance and false rejection) may be properly compromised through an analytical assessment of measurement errors and an optimization modeling. It is also discussed that a variety of optimization modeling may be enabled based on the derivation of measurement errors. Conclusion: It may be concluded that the design of screening inspection may further be facilitated by including the effect of measurement errors on the performance of screening inspection procedure.

Objective Speech Quality Measurement for Naturalness Assessment (자연성 평가를 위한 객관적 음질 평가 방법)

  • 장경아;이희원;송종회;배명진
    • Proceedings of the IEEK Conference
    • /
    • 2001.06a
    • /
    • pp.361-364
    • /
    • 2001
  • Speech quality measurement is sorted subjective and objective speech quality measurements based on the mathematics representation. Between two, subjective speech quality measurement is able to be evaluated more accurate speech quality then objective one but it has a demerit such as taking much more time and cost to performance it. However, using objective speech quality measurement being able to predict the result of evaluating the subjective speech quality compliments the demerit of subjective standards which is mentioned former. In this paper, we propose the objective speech quality measurement in order to evaluate naturalness assessment approximately like subjective speech quality measurement. We measured naturalness of speech with estimating speaking rate, variation of pitch and energy.

  • PDF

Impact of Health Insurance Type on the Quality of Hemodialysis Services: A Multilevel Analysis (의료보장 형태가 혈액투석 서비스 제공에 미치는 영향에 대한 다수준 분석)

  • Jung, Jin-Hee;Kwon, Soon-Man;Kim, Kyoung-Hoon;Lee, Seon-Kyoung;Kim, Dong-Sook
    • Journal of Preventive Medicine and Public Health
    • /
    • v.43 no.3
    • /
    • pp.245-256
    • /
    • 2010
  • Objectives: This study aims to compare quality indicators for the hemodialysis services between patients with health insurance and those with medical aid. Methods: This study used data from sampled hospitals that provided a hemodialysis service. A total of 2287 patients were selected, and the information for hemodialysis service has been granted from medical record reviews. A multi-level regression analysis was used to examine the differences in process and outcome indicators for hemodialysis between patients with health insurance and those with medical aid. Process indicators were defined as: frequency of hemodialysis, hemodialysis time, erythropoietin (EPO) use, measurement of hemodialysis dose at least once a month, measurement of phosphate at least once every three months, and measurement of albumin at least once every three months. Outcome indicators were defined as: hemodialysis adequacy, anemia management, blood pressure management, and calcium, phosphate and nutrition management. The total scores for outcome indicators ranged from 0 (worst) to 4 (best). Results: There was a significant difference in the measurement of hemodialysis dose at least once a month between patients with health insurance and those with medical aid (OR 0.66, 95% CI = 0.43 - 0.99). However, frequency of hemodialysis, hemodialysis time, EPO use, measurement of phosphate at least once every three months, measurement of albumin at least once every three months, hemodialysis adequacy management, Hb${\geq}$11 g/dL, blood pressure within the range of 100-140 /60-90 mmHg, calcium x phosphate${\leq}$55 $g^2/dL^2$ and albumin${\geq}$4 g/dL were not significantly different between the groups. Conclusions: There were no significant differences in outcome indicators for hemodialysis between the groups. Further studies are warranted into the mechanism that results in no differences in the outcome indicators for hemodialysis.

A Case Study on Tangible Contents Development for Contactless Physical Education (비대면 체육 교육을 위한 실감 콘텐츠 개발 사례)

  • Eun, Kwang-Ha;Hur, Young
    • The Journal of the Korea Contents Association
    • /
    • v.22 no.1
    • /
    • pp.47-57
    • /
    • 2022
  • Demands for tangible contents using VR/AR technologies are much bigger as contactless services such as sports, physical activity, and fitness are expanded after COVID-19. A variety of technologies such as an offer and analysis of tangible data through a sensor technology, users' physical movement sensing through a motion recognition sensor, a real-time measurement of a physical skeleton point a multiple access to a real-time video, and AI training are being utilized as main technologies. This case study utilized motion recognition technologies as the study on tangible contents necessary for indoor-based physical education, sports, and fitness in the contactless environment and suggested cases to develop the physical measurement contents by design approach for the measurement assessment necessary for the development in tangible contents. The research established lists of the measurement assessment based on professionals' consultations within the measurement assessment function through the test to plan tangible contents and developed tangible contents by reflecting them as assessment measurement elements of tangible contents. The research can be utilized as the design approach of industrial companies which intend to develop tangible contents as well as reference cases of the research on contactless tangible contents for the sports and physical education.

Review on International Caries Detection and Assessment System (치아우식증 탐지 및 평가의 기준 체계, ICDAS에 대한 고찰)

  • Kim, Hee-Eun
    • Journal of Korean society of Dental Hygiene
    • /
    • v.14 no.5
    • /
    • pp.609-615
    • /
    • 2014
  • Objectives : In most developed countries there has been a substantial decrease in the prevalence of dental caries in children of 12 years old over the past 40 years. This change in epidemiology highlights the importance of preventive management in dentistry. For successful management of early caries lesions, it is essential to detect and assess the pathological changes of dental caries. Therefore, the purpose of this study was to investigate the overview of International Caries Detection and Assessment System(ICDAS) criteria for the detection and assessment of early caries lesions by literature reviews. Methods : The author reviewed the MEDLINE search by the key words of 'caries assessment', 'caries detection', 'caries measurement', and 'ICDAS'. Results : This literature review provided an overview of International Caries Detection and Assessment System(ICDAS) criteria for the detection and assessment of early caries lesions. This article showed the principles, concept, and primary caries detection criteria of the ICDAS. The ICDAS can macroscopically measure the enamel surface changes and potential histological depth of caries lesions by the surface characteristics of the teeth. The ICDAS criteria allow researchers and clinicians to choose the stage of dental caries and characteristics for assessment. Conclusions : ICDAS can be an adjunct method to clinical decision making and preventive treatment planning.