• Title/Summary/Keyword: Measurement and assessment

Search Result 1,988, Processing Time 0.036 seconds

A Trial for Development of Health Profile (KHP 1.0) to Measure the Self-Perceived Health Status of Korean (한국인의 자가평가 건강수준 측정도구(KHP 1.0) 개발)

  • Yang, Jin-Sun;Chun, Jin-Ho
    • Journal of Preventive Medicine and Public Health
    • /
    • v.36 no.1
    • /
    • pp.11-23
    • /
    • 2003
  • Objectives : The 1990s has seen advances in the conceptualization of self-perceived health status which has important roles for individual health and the quality of life. Many types of standardized questionnaires have been developed with the current wide use of SF-36, NHP, andEuroQol. However, the outcomes of these tools may be different with regard to regional, cultural and emotional backgrounds. The purpose of this study was to trial the development of a Korean Health Profile (KHP 1.0) to measure the self-perceived health stati of Koreans. Methods : The KHP 1.0 was designed on the basis of the Medical Outcome Study Form 36 (SF-36), the Nottingham Health Profile (NHP), and the EuroQOL. It was composed of 9 scales; physical functioning, role limitation-physical, pain, general health, energy, social isolation, sleep, role limitation-emotional, and e-motional health. Self-reported chronic disease conditions, and the Zung's Self-Rating Depression Scale (SDS), were also checked for the evaluation of clinical validity. This study was conducted, from December 2000 to January 2001, on 800 middle-aged parents, with four high school students, with 100 retest sets being conducted two weeks later. From the 800 subjects there were 588 complete responses (effective response 73.5%). The reliability of the test-retest results, and the factor analysis on the validity of the KHP 1.0 components, were evaluated using the SPSS (ver 10.0) software. Results : The reliability of the KHP 1.0 was good with Cronbach's alpha (>0.6), test-retest correlation coefficients (>0.5), but with no significant differences from the paired t-test. From the psychometric validity tests, the 9 scales of the KHP 1.0 were divided into two components; physical and mental, and trimmed to the established model with 55% of the total variance, with the exception of role limitation-emotional. The clinical validity on the basis of the comparison for the four characteristic groups; healthy, physical conditions only, mental conditions only, and physical and mental conditions were also good. Conclusions : The KHP 1.0 appears to be a valid measurement tool of self-perceived health stati of Koreans, although there are limitations, i.e. sample size was too small, a limited number of middle-aged subjects, and it was based on unconfirmed diagnoses, etc. Therefore, further study is required to standardize the assessment.

Validity and Reliability of the Assessment Tool for Measuring Communication Skills of Dental Hygienist (치과위생사의 커뮤니케이션 기술 측정을 위한 평가 도구의 타당도와 신뢰도)

  • Moon, Hak-Jin;Lee, Soo-Young;Lim, Soon-Ryun
    • Journal of dental hygiene science
    • /
    • v.14 no.2
    • /
    • pp.198-206
    • /
    • 2014
  • The purpose of this study was to develop and validate tool for measuring the communication skills of dental hygienist. The survey was modified and revised to fit into Korean culture. Also the reliability and validity was tested in order to ensure the survey was properly evaluating communication skills of dental hygienists. A survey was conducted with outpatients in dental clinics located in Seoul, Gyeonggi, and Daejeon area. The 483 answers out of the total collected answers were used for the final analysis of the study, using PASW Statistics 18.0 and IBM SPSS AMOS 7.0 to measure the validity and reliability. The factor analysis showed that the communication skill of the dental hygienists was composed of three elements, namely 'being caring and respectful' communications, 'sharing information' communications and 'tending to comfort' communications to reduce pain and anxiety. The validity of the model examined by a confirmatory factor analysis satisfied most of the relevant requirements. All of the factors had the conceptual reliability and variant extracted index above the minimum requirements, ensuring reliability and concentrated validity. Also, the value of the square of the correlations between all latent factors which was larger than the square of the correlation between all of the factors, thus proving the discriment validity. Cronbach's ${\alpha}$ was 0.8, which shows high reliability level. In conclusion, it was proven that dental hygienist's communication skill measurement tool has high validity and reliability. Further, this study can be used to improve dental hygienists' communication skills. Therefore, this will improve oral health of clients and manage them.

Validity of Voice Handicap Index and Voice Analysis following Laryngeal Microsurgery for Benign Vocal Cord Lesions (양성 성대 질환 환자의 후두 미세 수술 전후 음성 장애 지수 및 음성 분석의 유용성)

  • Park, Young-Hak;Lee, Jeong-Hak;Joo, Young-Hoon;Park, Sung-Sin;Bang, Choong-Il;Kim, Min-Sik;Cho, Seung-Ho
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.16 no.1
    • /
    • pp.23-27
    • /
    • 2005
  • Background and Objectives : Voice disorders can cause problems in patients with benign vocal cord lesions emotionally, physically, economically and functionally. Neither subjective nor objective voice examinations can evaluate such factors adequately. The Voice Handicap Index (VHI) subjectively evaluates voice disorders in terms of physical, functional, emotional factors and measures the patient's perception of the impact of voice disorder. The purpose of this study is to evaluate the usefulness of VHI in the patients with benign vocal cord lesions. Materials and Method : The authors evaluated 37 patients who experienced laryngeal microsurgery for benign vocal cord lesions from september 2003 to August 2004. The VHI was used to measure the postoperative changes of the patient's perception and acoustic analysis and aerodynamic tests were also done. Statistical analysis was done using paired t-test and Pearson's correlation. Results : The VHI scores showed statistically significant reductions postoperatively. In acoustic analysis, jitter and shimmer had statistically significant reductions after surgery but noise-to-harmonics ratio did not. A statistically significant change in the average MFR and MPT perioperatively was found. The relationship between VHI and acoustic, aerodynamic analysis attained statistical significance. Conclusion : The VHI is a useful assessment tool to monitor the patient's self-perception of voice change after the surgery of benign vocal cord lesions. The VHI measurement, when combined with acoustic and aerodynamic analyses, will be helpful in comparing functional outcomes after voice surgery.

  • PDF

Longitudinal Study about Science Process Skills Item Forms Transition before and after Scholastic Ability Test for College (과학(科學) 탐구능력(探究能力) 평가(評價) 문항(問項) 유형(類型) 변화(變化)에 관(關)한 종단적(縱斷的) 연구(硏究))

  • Woo, Jong-Ok;Lee, Hang-Ro;Goo, Chang-Hyun
    • Journal of The Korean Association For Science Education
    • /
    • v.16 no.3
    • /
    • pp.314-328
    • /
    • 1996
  • This study investigated the literature about science process skills' evaluation to analyse transition of evaluation objectives before and after a Scholastic Ability Test for College Entrance. In the literature survey the researcher established a 3 dimensional science assessment framework with X axis as science concept, Y axis as science process skills and Z axis as problem context. In order to analysis and compare each items the researcher selected 210 items from the 1st to the 7th trials and 138 items from the 1st to 4th Scholastic Ability Test for College Entrance and sampled 2873 science achievement test items from 10 high schools. In accordance with this taxonomy the researcher analysed and compared science process skills item forms. The following results were drawn : The items were evenly distributed in all the four areas(Earth Science, Biology, Physics and Chemistry) of the science concept domain, but they were heavily concentrated on data analysis and drawing a conclusion in science process domain. In the domain of problem context school context was the majority. In spite of distribution like this the ratio on science process skills measurement items and science achievement test items was increased after the Scholastic Ability Test for College Entrance was given. Also the ratio on item expression type was increased. Item form was almost 5 options selection type in the national level test. Although there were 4 options selection type, 5 options selection type, short answer type, essay type in school level test, rising from 33.1% to 65.5% on 5 options selection type is exhibited. This study showed that the school level item form was better various than the nation level. This point like this is the evidence for the improvement toward the science process skills test and influenced by Scholastic Ability Test for College Entrance. The ratio on the item which joined with the 3 axes had a mean of 99.3% in nation level test and mean 44.9% in school achievement test level. But the ratio in the school achievement test level increased after the Scholastic Ability Test for College Entrance was given. In view of this study we must furthermore study the item types which can evaluate valjdately science process skill's five stage each and evaluation method by the high school students' problem solving patterns and features in scientific inquiry on all science process skills elements.

  • PDF

Culture Maturity of Lentinula edodes on Sawdust-Based Substrate in Relation to Fruiting Potential (표고 톱밥배지의 성숙도와 자실체형성 포텐셜)

  • Ohga, Shoji;Min, Du-Sik;Koo, Chang-Duck;Choi, Tae-Ho;Leonowicz, A.;Cho, Nam-Seok
    • Journal of the Korean Wood Science and Technology
    • /
    • v.28 no.1
    • /
    • pp.55-64
    • /
    • 2000
  • Culture maturity assessment can be used to control fruiting body flush timing. Culture maturity of sawdust-based substrate was evaluated by using oak mushroom, (Lentinula edodes (Berk.) Pegler). The influence of substrate water potential (${\psi}$) on the growth and fruiting of three genotypes of L. edodes was also investigated. Glucosamine content revealed a peak at the fruiting body senescent stage. Glucosamine increased steadily to the sporophore senescent stage, and sharply declined at crop treatment. Lipid phosphate and ergosterol contents peaked at pinning and button break stages, respectively. Therefore lipid phosphate and ergosterol contents would be considered as the convenient measurement for judging culture maturity and fruiting potentials. The substrate pH values before inoculation and on the fruiting stage were varied from 6.3 to 4.0. This pH changes were detected as changes in color from bluish purple to yellow by direct bromphenol blue(BPB) spraying, and shown a good correlation with fruit body yield of the 1 st flush. Concerning water potential of the cultures, a slight reduction of water potential, -0.5MPa, stimulated mycelial and colony growths on liquid, agar and sawdust-based substrates. The water potential of well-colonized matured substrate was -0.7MPa and -4.0MPa, before and after the fruiting, respectively. Excellent water providing capacity (higher ${\psi}$) is expected to well-matured cultures with a high density of mycelial colonization. Also, the substrate water potential significantly affected by the interaction between genotypes and spawn run time.

  • PDF

Moxibustion for Knee Osteoarthritis : A Protocol for a Pilot Randomized Controlled Trial (슬관절염에 대한 뜸 치료의 유효성 및 안전성 연구 : 무작위 대조 예비 임상연구 프로토콜)

  • Lee, Seung-Hoon;Kim, Kun-Hyung;Kim, Tae-Hun;Kim, Jung-Eun;Kim, Joo-Hee;Kang, Kyung-Won;Jung, So-Young;Kim, Ae-Ran;Park, Hyo-Ju;Shin, Mi-Suk;Hong, Kwon-Eui;Choi, Sun-Mi
    • Korean Journal of Acupuncture
    • /
    • v.28 no.4
    • /
    • pp.1-15
    • /
    • 2011
  • Objectives : The purpose of this study is to evaluate the feasibility of massive clinical research and to make a basic analysis on the effectiveness and safety of moxibustion treatment on knee osteoarthritis compared to usual care. Methods and Results : This study is a protocol for a pilot randomized controlled trial. Forty participants are assigned to the moxibustion group (n=20) and usual care group (n=20). Participants assigned to the moxibustion group receive moxibustion treatment on the affected knee(s) at six standard acupuncture points (ST36, ST35, ST34, SP9, Ex-LE04 and SP10) three times per week for four weeks (total of 12 sessions). Participants in the usual care group don't receive moxibustion treatment during the study period and follow-up are made on the 5th, 9th and 13th weeks after random allocation. Both groups are allowed to use any kind of treatment, including surgery, conventional medication, physical treatment, acupuncture, herbal medicine, over-the-counter drugs and other active treatments. Education material that explains knee osteoarthritis and current management options and self-exercise is provided for each group. The pain scale of the Korean Western Ontario and McMaster Universities Questionnaire (K-WOMAC) is the primary outcome measurement used in this study. Other subscales of the K-WOMAC, the Short-Form 36 Health Survey (SF-36), Beck Depression Inventory (BDI), Physical Function test, Patient Global Assessment, and Pain Numeric Rating Scale (NRS) are used as outcome variables to evaluate the effectiveness of acupuncture. Safety is assessed at every visit. Conclusions : The result of this trial will provide a basis for the effectiveness and safety of acupuncture treatment for knee osteoarthritis.

Measurement of Fractional Exhaled Nitric Oxide in Stable Bronchiectasis

  • Cho, Young-Jae;Lim, Hyo-Jeong;Park, Jong Sun;Lee, Jae Ho;Lee, Choon-Taek;Yoon, Ho Il
    • Tuberculosis and Respiratory Diseases
    • /
    • v.74 no.1
    • /
    • pp.7-14
    • /
    • 2013
  • Background: Fractional exhaled nitric oxide (FeNO) can be measured easily, rapidly, and noninvasively for the assessment of airway inflammation, particularly mediated by eosinophil, such as asthma. In bronchiectasis (BE), the pathogenesis has been known as chronic airway inflammation and infection with abnormal airway dilatation; however, there are little studies to evaluate the role of FeNO in BE. Methods: From March 2010 to February 2012, 47 patients with BE, diagnosed by high resolution computed tomography (HRCT), performed FeNO, compared with asthma and chronic obstructive pulmonary disease (COPD). All patients carried out a complete blood count including eosinophil count, chemistry, sputum examination, and spirometry, if indicated. A retrospective analysis was performed to elucidate the clinical role of FeNO in BE patients. Results: The mean FeNO levels in patients with BE was $18.8{\pm}1.5$ part per billion (ppb), compared to $48.0{\pm}6.4$ and $31.0{\pm}4.3$ in those with asthma and COPD, respectively (p<0.001). The FeNO levels tended to increase along with the disease severity scores by HRCT; however, it was statistically not significant. FeNO in BE with a co-infection of nontuberculous mycobacteria was the lowest at $17.0{\pm}3.5$ ppb among the study population. Conclusion: FeNO in BE was lower than other chronic inflammatory airway diseases, particularly compared with asthma. For clinical application of FeNO in BE, more large-scaled, prospective studies should be considered.

Mutual Adjustment of Oceanographic Measurements from leodo Station and Satellite Data (원격탐사자료와 이어도기지 해양관측자료를 이용한 상호 보정)

  • Kim Chang-Oh;Shim Jae-Seol;Hwang Jong-Sun;Lee Jae-Hak;Kim Soodung;Kim Jeong Woo
    • Korean Journal of Remote Sensing
    • /
    • v.21 no.2
    • /
    • pp.113-120
    • /
    • 2005
  • Oceanographic measurements from Ieodo Ocean Research Station and its vicinity were compared for assessment and mutually adjusted with satellite data. From the Topex/Poseidon and ERS-1/2 radar altimeter and scatterometer data, sea surface height, wind speed and direction were extracted and analyzed. Shipborne wind direction data acquired in June 1995 show good coherence with the satellite data, while sea surface height and wind speed show differences, possibly resulting from the distance between the measurement points. This can be improved by analyzing more satellite data or using other available shipborne data. The recent 3 months of Ieodo Station data between December 2004 and February 2005 were also analyzed and compared with the satellite data. The Ieodo Station data were found to have considerable gaps during the period as well as seriously biased particular when the data were averaged with some abnormal data. The Ieodo Station and satellite data were then mutually adjusted on the basis of their statistics. Ieodo Station oceanographic measurements are very efficient for ground-frothing of satellite data because they are stationary and the station is located far from the coast. On the other hand, the satellite measurements are the only data to fill up gaps and adjust biases of the Ieodo Station data.

Implementation and Evaluation of ECG Authentication System Using Wearable Device (웨어러블 디바이스를 활용한 ECG 인증 시스템 구현 및 평가)

  • Heo, Jae-Wook;Jin, Sun-Woo;Jun, Moon-Seog
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.10
    • /
    • pp.1-6
    • /
    • 2019
  • As mobile technologies such as Internet of Things (IoT)-based smart homes and financial technologies (FinTech) are developed, authentication by smart devices is used everywhere. As a result, presence-based biometric authentication using smart devices has become a new mainstream in knowledge-based authentication methods like the existing passwords. The electrocardiogram (ECG) is less prone to forgery, and high-level personal identification is its unique feature from among various biometric authentication methods, such as the pulse, fingerprints, the face, and the iris. Biometric authentication using an ECG is receiving a great deal of attention due to its uses in healthcare and FinTech. In this study, we implemented an ECG authentication system that allows users to easily measure and authenticate their ECG waveforms using a miniaturized wearable device, rather than a large and expensive measurement device. The implemented ECG authentication system identifies ECG features through P-Q-R-S-T feature point identification, and was user-certified under the proposed authentication protocols. Finally, assessment of measurements in a majority of adult males showed a relatively low false acceptance rate of 1.73%, and a low false rejection rate of 4.14%, in a stable normal state. In a high-activity state, the false acceptance rate was 13.72%, and the false rejection rate was 21.68%. In a high-heart rate state, the false acceptance rate was 10.48%, and the false rejection rate was 11.21%.

A vision-based system for long-distance remote monitoring of dynamic displacement: experimental verification on a supertall structure

  • Ni, Yi-Qing;Wang, You-Wu;Liao, Wei-Yang;Chen, Wei-Huan
    • Smart Structures and Systems
    • /
    • v.24 no.6
    • /
    • pp.769-781
    • /
    • 2019
  • Dynamic displacement response of civil structures is an important index for in-construction and in-service structural condition assessment. However, accurately measuring the displacement of large-scale civil structures such as high-rise buildings still remains as a challenging task. In order to cope with this problem, a vision-based system with the use of industrial digital camera and image processing has been developed for long-distance, remote, and real-time monitoring of dynamic displacement of supertall structures. Instead of acquiring image signals, the proposed system traces only the coordinates of the target points, therefore enabling real-time monitoring and display of displacement responses in a relatively high sampling rate. This study addresses the in-situ experimental verification of the developed vision-based system on the Canton Tower of 600 m high. To facilitate the verification, a GPS system is used to calibrate/verify the structural displacement responses measured by the vision-based system. Meanwhile, an accelerometer deployed in the vicinity of the target point also provides frequency-domain information for comparison. Special attention has been given on understanding the influence of the surrounding light on the monitoring results. For this purpose, the experimental tests are conducted in daytime and nighttime through placing the vision-based system outside the tower (in a brilliant environment) and inside the tower (in a dark environment), respectively. The results indicate that the displacement response time histories monitored by the vision-based system not only match well with those acquired by the GPS receiver, but also have higher fidelity and are less noise-corrupted. In addition, the low-order modal frequencies of the building identified with use of the data obtained from the vision-based system are all in good agreement with those obtained from the accelerometer, the GPS receiver and an elaborate finite element model. Especially, the vision-based system placed at the bottom of the enclosed elevator shaft offers better monitoring data compared with the system placed outside the tower. Based on a wavelet filtering technique, the displacement response time histories obtained by the vision-based system are easily decomposed into two parts: a quasi-static ingredient primarily resulting from temperature variation and a dynamic component mainly caused by fluctuating wind load.