• Title/Summary/Keyword: Measurement and assessment

Search Result 1,988, Processing Time 0.028 seconds

Assessment of inlay ceramic restorations manufactured using the hot-pressing method (열 가압 방식을 사용하여 제작된 인레이 세라믹 수복물의 적합도 평가)

  • Lee, Beom-Il;You, Seung-Gyu;You, Seung-Min;Park, Dong-In;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.42 no.1
    • /
    • pp.9-16
    • /
    • 2020
  • Purpose: The purpose of this study was to compare the marginal and internal fit of lithium disilicate ceramic inlay produced by heat pressing that inlay pattern made by subtractive manufacturing and additive manufacturing method. Methods: A mandibular lower first molar that mesial occlusal cavity (MO cavity) die was prepared. After fabricating an epoxy resin model using a silicone impression material, epoxy resin die was scanned with a dental model scanner to design an MO cavity inlay. The designed STL pile was used to fabricate wax patterns and resin patterns, and then lithium disilicate ceramic inlays were fabricated using hot-press method. For the measurement of the marginal and internal gap of the lithium disilicate, silicone replica method was applied, and gap was measured through an optical microscope (x 80). Data were tested for significant differences using the Mann-Whitney Utest. Results: The marginal fit was 103.56±9.92㎛ in the MIL-IN group and 81.57±9.33㎛ in the SLA-IN group, with a significant difference found between the two groups (p<0.05). The internal fit was 120.99±17.52㎛ in the MIL-IN group and 99.18±6.65㎛ in the SLA-IN group, with a significant difference found between the two groups (p<0.05). Conclusion: It is clinically more appropriate to apply the additive manufacturing than subtractive manufacturing method in producing lithium disilicate inlay using CAD/CAM system.

Calibration by Comparison and Uncertainty Assessment of Industrial Thermometers at the Boiling Point of Nitrogen (질소의 끓는점에서의 산업용 온도계 비교 교정과 불확도 평가)

  • Yang, Inseok;Gam, Kee Sool;Joung, Wukchul;Kim, Yong-Gyoo
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.6
    • /
    • pp.404-409
    • /
    • 2013
  • We devised calibration procedure for industrial thermometers by a comparison method at the boiling point of nitrogen (${\sim}-196^{\circ}C$). The uncertainty of the calibration was 4 mK (k = 2). As experimentally demonstrated in this work, the effect of the atmospheric pressure on the boiling point of nitrogen can be easily detected by the thermometer. Therefore, when the boiling point of nitrogen is used for calibration of thermometer by comparison, either a reference thermometer must be used to provide the reference temperature or the effect of atmospheric pressure should be carefully considered. The use of a copper block with a large thermal mass soaked into the liquid nitrogen was proven to be more reliable, and the stability of the temperature immersed into the copper block was 1.4 mK. The temperatures at the thermometer wells, evaluated by the crossed-measurement method to compensate for the inaccuracy of the thermometers and the linear drift of the temperature of the copper block, were equivalent within 0.23 mK of standard uncertainty.

Assessment of Magnetic Field Mitigation and Electrical Environmental Effects for Commercially Operating 154kV Transmission Lines with Passive Loop

  • Lee, Byeong-Yoon;Myung, Sung-Ho;Ju, Mun-No;Cho, Yeun-Gyu;Lee, Dong-Il;Lim, Yun-Seog;Kim, Sang-Beom
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.3
    • /
    • pp.991-996
    • /
    • 2014
  • Power frequency magnetic field is still a critical problem for new construction of overhead power transmission lines in Korea because most people have been concerned about possibly carcinogenic effects of it. Although reference level of power frequency(60Hz) magnetic field has been set to 200uT in ICNIRP guidelines published in 2010, Korean government has no intention of adjusting 83.3uT specified by law in 2006 to this new reference level in consideration of people's concerns for the time being. Regardless of the current regulated magnetic field value, electric utility company has been trying to reduce magnetic field in the residential area in the vicinity of overhead power transmission lines to take into account of public concerns on the long-term effect of magnetic fields. In an effort to reduce magnetic field, engineering side has made considerable efforts to develop passive loop based, cost-effective mitigation technique of power frequency magnetic field more than ten years. In order to verify developed power frequency magnetic field mitigation technique based on passive loop, a horizontal type of passive loop was designed and installed for commercially operating 154kV overhead power transmission line for the first time in Korea. The measurement results before and after the installation of passive loop showed that magnetic field could be reduced to about 20%. The electrical environmental effects such as AN, RI and TVI were assessed before and after the installation of passive loop and these values were complied with the requirements specified by electric utility. It has been confirmed from the field test results that passive loop could be commercially and cost-effectively utilized to mitigate power frequency magnetic field.

Effect of Manual Acupuncture for Mild-to-Moderate Carpal Tunnel Syndrome: A Systematic Review

  • Huh, Jeong Ho;Jeong, Hye In;Kim, Kyeong Han
    • Journal of Pharmacopuncture
    • /
    • v.24 no.4
    • /
    • pp.153-164
    • /
    • 2021
  • Objectives: Despite the low cost and high accessibility of manual acupuncture (MA) treatments for the carpal tunnel syndrome (CTS), this intervention has not been uniformly evaluated in systematic reviews (SR), and no SR has evaluated MA monotherapy for CTS. This review was conducted to summarize the findings and undertake a quality assessment of randomized controlled trials (RCTs) of acupuncture treatment methods for mild-to-moderate CTS to identify clinical evidence for the use of MA in CTS. Methods: We searched five databases for articles on relevant RCTs that were published until June 2021 without imposing specific restrictions, such as age or sex, on CTS patients. RCTs that evaluated MA were included without any restriction on comparator interventions. Measurement tools for evaluating pain reduction and functional improvement or for evaluating efficacy using electrophysiological indicators were included as outcome measures. Results: We included seven RCTs, of which three studies reported both post-treatment improvement effects and statistical significance using p-values for all outcomes. Five studies reported statistically significant intergroup differences (p-values for all outcomes) in posttreatment improvement. None of the studies reported severe adverse effects of MA. In all of the RCTs, the reporting rates of the 2c, 2a, and 6a items of STRICTA 2010 were 14%, 29%, and 29%, respectively. PC7 (Daereung) was used to treat CTS in all of the included studies. Conclusion: MA can be used for CTS treatment without serious adverse effects. PC7 was the most commonly used acupoint. In order to ensure objective and reliable reporting, accurate standardization of acupuncture treatment methods acupoint terms should be undertaken in future RCTs.

Development of a Laser Absorption NO/$NO_2$ Measuring System for Gas Turbine Exhaust Jets

  • Zhu, Y.;Yamada, H.;Hayashi, S.
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.802-806
    • /
    • 2004
  • For the protection of the local air quality and the global atmosphere, the emissions of trace species including nitric oxides (NO and NO$_2$) from gas turbines are regulated by local governments and by the International Civil Aviation Organization. In-situ measurements of such species are needed not only for the development of advanced low-emission combustion concepts but also for providing emissions data required for the sound assessment of the effects of the emissions on environment. We have been developing a laser absorption system that has a capability of simultaneous determination of NO and NO$_2$concentrations in the exhaust jets from aero gas turbines. A diode laser operating near 1.8 micrometer is used for the detection of NO while a separated visible tunable diode laser operating near 676 nanometers is used for NO$_2$. The sensitivities at elevated temperature conditions were determined for simulated gas mixtures heated up to 500K in a heated cell of a straight 0.5 m optical path. Sensitivity limits estimated as were 30 ppmv-m and 3.7 ppmv-m for NO and NO$_2$, respectively, at a typical exhaust gas temperature of 800K. Experiments using the simulated exhaust flows have proven that $CO_2$ and $H_2O$ vapor - both major combustion products - do not show any interference in the NO or NO$_2$ measurements. The measurement system has been applied to the NO/NO$_2$ measurements in NO and NO$_2$ doped real combustion gas jets issuing from a rectangular nozzle having 0.4 m optical path. The lower detection limits of the system were considerably decreased by using a multipass optical cell. A pair of off-axis parabola mirrors successfully suppressed the beam steering in the combustion gas jets by centralizing the fluctuating beam in sensor area of the detectors.

  • PDF

Analysis of Work-Related Musculoskeletal Disorders Research Trends Using Keyword Frequency Analysis and CONCOR Technique

  • Geon-Hui Lee;Seo-Yeon Choi
    • Journal of the Korea Society of Computer and Information
    • /
    • v.28 no.8
    • /
    • pp.137-144
    • /
    • 2023
  • One of the methods being suggested as a way to address social issues is the utilization of big data analysis techniques. In this study, we utilized keyword network analysis and CONCOR analysis techniques to analyze the research trends on work-related musculoskeletal disorders. The findings of this study are as follows: Firstly, the number of papers on work-related musculoskeletal disorders has been consistently increasing, with an average of over 33 articles published per year since the investigation of musculoskeletal risk factors in 2003. The publication rate showed an increase from 2007 to 2009. Secondly, the frequency of the top keywords identified through text mining were as follows: work (4,940), musculoskeletal disorders (2,197), symptoms (1,836), related (1,769), musculoskeletal system (1,421). Thirdly, the CONCOR analysis resulted in the formation of four clusters: ' Musculoskeletal disorder treatment', 'Occupational health and safety management', 'Work environment assessment', and ' Workplace environment measurement'. It is expected that this study will contribute to the development of research on musculoskeletal disorders and provide various directions for future studies.

Simulation of Time of Flight Diffraction Signals for Reactor Vessel Head Penetrations (원자로 상부 헤드 관통관 TOFD 신호 시뮬레이션)

  • Lee, Tae-Hun;Kim, Young-Sik;Lee, Jeong-Seok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.4
    • /
    • pp.273-280
    • /
    • 2016
  • The simulation of nondestructive testing has been used in the prediction of the signal characteristics of various defects and in the development of the procedures. CIVA, a simulation tool dedicated to nondestructive testing, has good accuracy and speed, and provides a three-dimensional graphical user interface for improved visualization and familiar data displays consistent with an NDE technique. Even though internal validations have been performed by the CIVA software development specialists, an independent validation study is necessary for the assessment of the accuracy of the software prior to practical use. In this study, time of flight diffraction signals of ultrasonic inspection of a calibration block for reactor vessel head penetrations were simulated using CIVA. The results were compared to the experimentally inspected signals. The accuracy of the simulated signals and the possible range for simulation were verified. It was found that, there is a good agreement between the CIVA simulated and experimental results in the A-scan signal, B-scan image, and measurement of depth.

Evaluation of Combustion Characteristics of Outdoor Advertisement Materials (옥외 광고물 소재의 연소특성 평가)

  • Eom, Sang-Yong;Kim, Kyoung-Jin;Lee, Su-Kyung
    • Fire Science and Engineering
    • /
    • v.26 no.5
    • /
    • pp.79-84
    • /
    • 2012
  • Combustion characteristics of outdoor advertisement materials were evaluated for fire risk assessment about fire expanding. At this study, the flame retardancy and the limiting oxygen index (LOI) was measured by UL 94 and ASTM D 2863 respectively. At the result of flame retardancy, foamex was V-0 grade and those of others were out of grade. LOI measurement showed that the LOI of foamex was highest in the samples. The cone calorimeter test was done by ISO 5660-1 to find the combustion characteristics. The cone calorimeter test showed that the outdoor advertisement materials were not good to prevent of fire expanding. The time to ignition (TTI) of flex was the fastest and the peak heat release rate (PHRR) as well as the total heat release (THR) of acrylic panel was higher than those of others.

An Exploratory Study on the Meaning of 'the Patient Trusts the Doctor' (의사-환자 관계에서 '환자가 의사를 신뢰한다'의 의미 고찰)

  • Kim, Min-Jeong
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.6
    • /
    • pp.415-423
    • /
    • 2017
  • Patient's trust in their physician is crucial for relationship between patients and their doctors, treatment outcomes such as satisfaction and adherence or revisits. The purpose of this study is to investigate the meaning of trusting the doctor in the doctor - patient relationship and to examine it through the multidimensional measurement tools. Using the convenience sampling method, 328 respondents in their 20s or older who had visited the hospital within 6 months were used as the analysis data. As a result of the research, it is difficult to define the meaning of the patient's trust in the doctor, but it can be summarized as having at least four meanings. First, the doctor should listen carefully to the patient's story and show communication behaviors expressing interest and forming an atmosphere of dialogue. Second, the patient's health should be considered first to understand the patient and empathize with the patient. Third, it should be honest in the examination and procedures related to the treatment as well as the technical ability. Finally, we should try to cooperate with patients.

Investigation on Ultrasonographic Observation of Recipient Ovaries, Serum Progesterone Level Measurement and Their Relationship with Pregnancy Rate (수란우의 초음파진단에 의한 난소 상태 및 혈청 Progesterone 농도가 수정란이식 후 수태율에 미치는 영향)

  • 김일화;류일선;서국현;이동원;박수봉;김현종;연성흠;박성재;허태영
    • Journal of Embryo Transfer
    • /
    • v.15 no.3
    • /
    • pp.263-270
    • /
    • 2000
  • The ovaries of 178 Holstein heifers or cows (heifer; 41, 1 parity; 72, 2$\leq$ parity; 65) on Day 6 or 7 (Day 0=day of estrus) were examined by transrectal ultrasonography. Diameter of corpus luteum (CL) and large follicle ( $\geq$ 10 mm), and luteal tissue area were determined by ultrasound system with a 5 MHB rectal probe. Blood samples were taken to progesterone analysis. After selection of recipients, frozen Holstein embryos were thawed and directly transferred to recipients non-surgically. The diameter of CL and luteal tissue area was greater (P<0.01) on Day 7 than on Day 6 in heifers, 1 parity or 2 $\leq$ parity cows, respectively, although progesterone concentrations were not different. The presence of fluid-filled luteal cavitied or multiple CL (2 or more) did not affect serum progesterone concentration. A large follicles were observed in 67.4% of heifers or cows and the average diameter was 14.1 mm. Greater luteal tissue area attributed higher pregnancy in heifers, but not in cows, although there were no difference on pregnancy rate according to progesterone concentration in heifers or cows. The pregnancy rate of recipients contained a large follicle at embryo transfer was lower than that of recipients not contained. These results show ultrasonic assessment of ovaries in Holstein recipients is a reliable tool to determine the follicle and CL for recipient selection.

  • PDF