• 제목/요약/키워드: Measurement and assessment

Search Result 1,988, Processing Time 0.031 seconds

A Method for the Reduction of Skin Marker Artifacts During Walking : Application to the Knee

  • Mun, Joung-Hwan
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.6
    • /
    • pp.825-835
    • /
    • 2003
  • Previous studies have demonstrated the importance of joint angle errors mainly due to skin artifact and measurement errors during gait analysis. Joint angle errors lead to unreliable kinematics and kinetic analyses in the investigation of human motion. The purpose of this paper is to present the Joint Averaging Coordinate System (JACS) method for human gait analysis. The JACS method is based on the concept of statistical data reduction of anatomically referenced marker data. Since markers are not attached to rigid bodies, different marker combinations lead to slightly different predictions of joint angles. These different combinations can be averaged in order to provide a "best" estimate of joint angle. Results of a gait analysis are presented using clinically meaningful terminology to provide better communication with clinical personal. In order to verify the developed JACS method, a simple three-dimensional knee joint contact model was developed, employing an absolute coordinate system without using any kinematics constraint in which thigh and shank segments can be derived independently. In the experimental data recovery, the separation and penetration distance of the knee joint is supposed to be zero during one gait cycle if there are no errors in the experimental data. Using the JACS method, the separation and penetration error was reduced compared to well-developed existing methods such as ACRS and Spoor & Veldpaus method. The separation and penetration distance ranged up to 15 mm and 12 mm using the Spoor & Veldpaus and ACRS method, respectively, compared to 9 mm using JACS method. Statistical methods like the JACS can be applied in conjunction with existing techniques that reduce systematic errors in marker location, leading to an improved assessment of human gait.

Comparison of Primary Breast Cancer Size by Mammography and Sonography

  • Wang, Jian-Tao;Chang, Li-Ming;Song, Xin;Zhao, Li-Xin;Li, Jun-Tao;Zhang, Wei-Guo;Ji, Ying-Bin;Cai, Li-Na;Di, Wei;Yang, Xin-Yu
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.22
    • /
    • pp.9759-9761
    • /
    • 2014
  • Purpose: To compare tumor size by mammography and sonography and align with pathological results in primary breast cancer cases. Materials and Methods: We retrospectively reviewed 95 primary breast cancer patients who underwent mammography and sonography from January 2011 to June 2012. The largest tumor diameter was chosen as sizing reference for each imaging modality. The measurements of mammography and sonography were considered concordant if they were within the measurement of pathological results ${\pm}0.5cm$. Pearson's correlation coefficient was calculated for imaging results. Results: The range of the maximum diameter was 0.6cm-10.5cm and mean value was $3.81{\pm}2.04cm$ by pathological results, 0.7cm-12.4 cm and $3.99{\pm}2.19cm$ by mammography, and 0.9cm-11.0cm and $3.63{\pm}2.01cm$ by sonography, respectively. Sonography (R: 0.754), underestimated tumor size, but had a better correlation with pathological tumor size compared to mammography (R: 0.676), which overestimated tumor size. Conclusions: Sonography is superior to mammography in assessment of primary breast cancer.

Uncertainty Assessment of a Towed Underwater Stereoscopic PIV System (예인수조용 스테레오스코픽 입자영상유속계 시스템의 불확실성 해석)

  • Seo, Jeonghwa;Seol, Dong Myung;Han, Bum Woo;Yoo, Geuksang;Lim, Tae Gu;Park, Seong Taek;Rhee, Shin Hyung
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.51 no.4
    • /
    • pp.311-320
    • /
    • 2014
  • Test uncertainty of a towed underwater Stereoscopic Particle Image Velocimetry (SPIV) system was assessed in a towing tank. To estimate the systematic error and random error of mean velocity and turbulence properties measurement, velocity field of uniform flow was measured. Total uncertainty of the axial component of mean velocity was 1.45% of the uniform flow speed and total uncertainty of turbulence properties was 3.03%. Besides, variation of particle displacement was applied to identify the change of error distribution. In results for variation of particle displacement, the error rapidly increases with particle movement under one pixel. In addition, a nominal wake of a model ship was measured and compared with existing experimental data by five-hole Pitot tubes, Pitot-static tube, and hot wire anemometer. For mean velocity, small local vortex was identified with high spatial resolution of SPIV, but has serious disagreement in local maxima of turbulence properties due to limited sampling rate.

Safety evaluation of cricket(Gryllus bimaculatus) extract in Sprague-Dawley rats

  • Lee, Somin;Ahn, Kyu Sup;Ryu, Hyeon Yeol;Kim, Hye Jin;Lee, Jin Kyu;Cho, Myung-Haing;Ahn, Mi Young;Song, Kyung Seuk
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.32 no.1
    • /
    • pp.12-25
    • /
    • 2016
  • Recently, research investment in the improvement of food safety as a food source and specializing of nutritional source of edible insects is being actively conducted. Cricket especially has been attracting considerable interest in entomophagy; however, research on the safety assessment of cricket is limited. This study investigated the effects of cricket ethanol extract when orally administrated in Sprague-Dawley rats. Here, we performed a 4 wk repeated oral dose toxicity test in Sprague-Dawley rats following the Organization for Economic Cooperation and Development test guidelines 407 under Good Laboratory Practice regulation. Rats were randomly allocated 4 groups: vehicle control, 250, 500, 1,000 mg/kg test groups and administrated based on body weight for 28 d. The animals were observed for mortalities and clinical signs, body weight changes, food and water consumption. At the end of treatment period, blood and urine were collected and analyzed. Subsequently, the animals were sacrificed and subjected to gross pathological examination and organ weight measurement. The organs were preserved for histopathological examination. The results showed that there were no systemic toxicological effects related with the cricket ethanol extract in the 4 wk oral repeated dose toxicity study. It is considered that NOAEL of cricket ethanol extract is greater than 1,000 mg/kg/d and there was no target organ detected.

Misclassification Adjustment of Family History of Breast Cancer in a Case-Control Study: a Bayesian Approach

  • Moradzadeh, Rahmatollah;Mansournia, Mohammad Ali;Baghfalaki, Taban;Ghiasvand, Reza;Noori-Daloii, Mohammad Reza;Holakouie-Naieni, Kourosh
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.18
    • /
    • pp.8221-8226
    • /
    • 2016
  • Background: Misreporting self-reported family history may lead to biased estimations. We used Bayesian methods to adjust for exposure misclassification. Materials and Methods: A hospital-based case-control study was used to identify breast cancer risk factors among Iranian women. Three models were jointly considered; an outcome, an exposure and a measurement model. All models were fitted using Bayesian methods, run to achieve convergence. Results: Bayesian analysis in the model without misclassification showed that the odds ratios for the relationship between breast cancer and a family history in different prior distributions were 2.98 (95% CRI: 2.41, 3.71), 2.57 (95% CRI: 1.95, 3.41) and 2.53 (95% CRI: 1.93, 3.31). In the misclassified model, adjusted odds ratios for misclassification in the different situations were 2.64 (95% CRI: 2.02, 3.47), 2.64 (95% CRI: 2.02, 3.46), 1.60 (95% CRI: 1.07, 2.38), 1.61 (95% CRI: 1.07, 2.40), 1.57 (95% CRI: 1.05, 2.35), 1.58 (95% CRI: 1.06, 2.34) and 1.57 (95% CRI: 1.06, 2.33). Conclusions: It was concluded that self-reported family history may be misclassified in different scenarios. Due to the lack of validation studies in Iran, more attention to this matter in future research is suggested, especially while obtaining results in accordance with sensitivity and specificity values.

Tree Height Estimation of Pinus densiflora and Pinus koraiensis in Korea with the Use of UAV-Acquired Imagery

  • Talkasen, Lynn J.;Kim, Myeong Jun;Kim, Dong Hyeon;Kim, Dong Geun;Lee, Kawn Hee
    • Journal of Forest and Environmental Science
    • /
    • v.33 no.3
    • /
    • pp.187-196
    • /
    • 2017
  • The use of unmanned aerial vehicles (UAV) for the estimation of tree height is gaining recognition. This study aims to assess the effectiveness of tree height estimation of Pinus densiflora Sieb. et Zucc. and Pinus koraiensis Sieb. et Zucc. using digital surface model (DSM) generated from UAV-acquired imageries. Images were taken with the $Trimble^{(R)}$ UX5 equipped with Sony ${\alpha}5100$. The generated DSM, together with the digital elevation model (DEM) generated from a digital map of the study areas, were used in the estimation of tree height. Field measurements were conducted in order to generate a regression model and carry out accuracy assessment. The obtained coefficients of determination (R2) and root mean square error (RMSE) for P. densiflora (R2=0.71; RMSE=1.00 m) and P. koraiensis (R2=0.64; RMSE=0.85 m) are comparable to the results of similar studies. The results of the paired two-tailed t-test show that the two tree height estimation methods are not significantly different (p-value=0.04 and 0.10, alpha level=0.01), which means that tree height estimation using UAV imagery could be used as an alternative to field measurement.

Perceived Air Quality Assessment of Occupants According to Indoor Air Quality (실내공기질에 따른 재실자의 인식성 공기질 평가)

  • Woo, Byung-Lyul;Lee, Hyun-Su;Ahn, Ho-Gi;Jung, Soon-Won;Hwang, Moon-Young;Park, Choong-Hee;Yu, Seung-Do;Yang, Won-Ho
    • Journal of Environmental Science International
    • /
    • v.20 no.1
    • /
    • pp.61-69
    • /
    • 2011
  • Perceived air quality (PAQ) is defined as evaluation of indoor air satisfaction and comfortable sensory by occupants. However, there are differences between criteria of indoor pollutants and lowest sensory thresholds. In this study, we compared indoor PAQ by questionnaire with measured benzene, toluene and nitrogen dioxide ($NO_2$) concentrations in home indoors. The $NO_2$ concentration was the highest in Seoul, while benzene and toluene were the highest in Asan. Average PAQ score in winter was higher than that in summer. Significant correlations between PAQs of home indoor air pollution and measured pollutant concentrations were not shown and correlation coefficients (r) ranged between -0.453

Measurement and Investigation of Combustible Properties of n-Heptane for Risk Assessment of Gasoline Tank (가솔린탱크의 위험성평가를 위한 노말헵탄의 연소특성치 측정 및 고찰)

  • Ha, Dong-Myeong;Jeong, Kee-Sin;Lee, Sung-Jin;Cho, Yong-Sun;Yoon, Myung-O
    • Fire Science and Engineering
    • /
    • v.24 no.6
    • /
    • pp.76-81
    • /
    • 2010
  • For the safe handling of n-heptane, the explosion limit at $25^{\circ}C$, the temperature dependence of the explosion limits and the lower flash point were investigated. And AITs (auto-ignition temperatures) by ignition time delay for n-heptane were experimented. By using the literatures data, the lower and upper explosion limits of n-heptane recommended 1.0 Vol% and 7.0 Vol%, respectively. And the lower flash points of n-heptane recommended $-4^{\circ}C$. This study measured relationship between the AITs and the ignition delay times by using ASTM E659-78 apparatus for n-heptane and the experimental AIT of n-hexane was $225^{\circ}C$. The new equation for predicting the temperature dependence of the explosion limits of n-heptane is proposed. The values calculated by the proposed equations were a good agreement with the literature data.

The Detection Distance of Colored Target using Various Automotive Headlamps

  • Kim, Jung-Yong;Lee, Ho-Sang;Min, Seung-Nam;Lee, Min-Ho
    • Journal of the Ergonomics Society of Korea
    • /
    • v.31 no.3
    • /
    • pp.421-426
    • /
    • 2012
  • As headlamp technology advances, newly developed various headlamps were introduced in the market. The objective of this study is to quantitatively analyze the detection distance of the recently developed LED headlamps and existing headlamps, complying with specific technical standard. Background: The detection distance of headlamps is very important to prevent automobile accident at night time. The studies of detection distance of LED, Halogen and HID headlamp have been conducted, but no study has shown the detection distance of pedestrian target with various colors (Black, White, Blue). Method: The experiment of detection distance was conducted with 30 people, which divide into 2 groups as 15 men and 15 women. Automatic transferable target on the rail was manufactured in order to reduce the error of study's result, and ANOVA also conducted to analyze the main effect with sign color, sex and headlamp classified by detection distance. In addition, the luminance by average detection distance was measured as well. Results: The detection distance of headlamps was HID > LED > Halogen. The luminance measure of LED headlamp was lower than HID and Halogen headlamps. Conclusion: The headlamp performs a very significant role for safety at night time but it needs to be improved through assessment of visual characteristics. Also, it needs to be suggested the need of test method for dynamic detection distance concerning technical development is suggested.

Effect of Craniocervical Flexion Exercise with Masticatory Muscle Contraction on Deep Cervical Muscle Thickness and Neck Disability Index in Patient with Neck Pain (씹기근육 수축을 동반한 머리목굽힘운동이 목통증 환자의 깊은목뼈굽힘근의 수축두께와 목장애지수에 미치는 영향)

  • Park, Eun-Soo;Choi, Ho-Suk;Shin, Won-Seob
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.11 no.4
    • /
    • pp.139-146
    • /
    • 2016
  • PURPOSE: The purpose of this study was to determine the effect of craniocervical flexion exercise with masticatory muscle contraction in patients with neck pain. Patients with neck pain also experience muscle weakness and limitation of activities of daily living. Craniocervical flexion exercise with masticatory muscle contraction may increase the thickness of the deep cervical flexor muscles, thereby reducing pain and limitations on activities of daily living. METHODS: Twenty-six volunteers participated in this study. The subjects were randomly divided into an experimental group (n=13) and a control group (n=13). Both groups performed craniocervical flexion exercise using a pressure biofeedback unit; the experimental group performed craniocervical flexion exercise with masticatory muscle contraction for 20 minutes, 3 times a week for 4 weeks. Assessment tools included ultrasonography for measurement of muscle thickness and the Neck Disability Index for the level of pain and function. RESULTS: The rate of change in muscle thickness in both groups significantly increased (p<.05), with a significantly greater increase in the experimental group than in the control group (p<.05). The Neck Disability Index score significantly improved (p<.05) in both groups, with significantly greater improvement in the experimental group compared with the control group (p<.05). CONCLUSION: These results suggest that craniocervical flexion exercise with masticatory muscle contraction can be effective in increasing muscle thickness and improving the Neck Disability Index score in patients with neck pain.