• Title/Summary/Keyword: Measurement and assessment

Search Result 1,996, Processing Time 0.029 seconds

Effect of Visual and Somatosensory Information Inputs on Postural Sway in Patients With Stroke Using Tri-Axial Accelerometer Measurement

  • Chung, Jae-yeop
    • Physical Therapy Korea
    • /
    • v.23 no.1
    • /
    • pp.87-93
    • /
    • 2016
  • Background: Posture balance control is the ability to maintain the body's center of gravity in the minimal postural sway state on a supportive surface. This ability is obtained through a complicated process of sensing the movements of the human body through sensory organs and then integrating the information into the central nervous system and reacting to the musculoskeletal system and the support action of the musculoskeletal system. Motor function, including coordination, motor, and vision, vestibular sense, and sensory function, including proprioception, should act in an integrated way. However, more than half of stroke patients have motor, sensory, cognitive, and emotional disorders for a long time. Motor and sensory disorders cause the greatest difficulty in postural control among stroke patients. Objects: The purpose of this study is to determine the effect of visual and somatosensory information on postural sway in stroke patients and carrying out a kinematic analysis using a tri-axial accelerometer and a quantitative assessment. Methods: Thirty-four subjects posed four stance condition was accepted various sensory information for counterbalance. This experiment referred to the computerized dynamic posturography assessments and was redesigned four condition blocking visual and somatosensory information. To measure the postural sway of the subjects' trunk, a wireless tri-axial accelerometer was used by signal vector magnitude value. Ony-way measure analysis of variance was performed among four condition. Results: There were significant differences when somatosensory information input blocked (p<.05). Conclusion: The sensory significantly affecting the balance ability of stroke patients is somatosensory, and the amount of actual movement of the trunk could be objectively compared and analyzed through quantitative figures using a tri-axial accelerometer for balance ability.

A Comparison of Self-Reported Fatigue and Fatigue-Regulating Behaviors of Rheumatoid Arthritic Patients and Normal Persons (류마티스관절염 환자와 정상인의 피로도 및 피로조절행위 비교)

  • Jung, Bok-Hee;Kim, Myung-Ae
    • Journal of muscle and joint health
    • /
    • v.6 no.1
    • /
    • pp.51-72
    • /
    • 1999
  • The purpose of this study is to compar self-reported fatigue and fatigue-regulating behaviors of rheumatoid arthritic patients and normal persons. This study collected the data from 75 rheumatoid arthritic patents visited the departments of internal medicine or orthopedics of four general hospitals T-city and K-city by means of direct interview and questionnaires. in this study also collected data from 75 normal persons who had not been exposed to any other disease in T-city and K-city by means of direct interviews anti questionnaires which were conducted by two trained nurses. This experiment was conducted from August 1, 1998 to October 15, 1998. This study used both MAP(Multi-Dimentional Assessment of Fatigue) developed by Belza(1995) to measure fatigue and the measurement developed by Kwon, Young-Eun to investigate fatigue regulating behaviors. The collected materials were analyzed by means of descriptive statistics, t-test, and the ANCOVA according to the SPSS PC+ program. The findings are as follows : 1. There was the statistically significant difference(t =5.07, p=.000), between rheumatoid arthritic patients(32.76 points) and normal persons(25.81 points) in t-test comparison by group about fatigue. A fatigue degree of rheumatoid arthritic patient group was high in five kinds of lower realms such as common fatigue degree, fatigue severity to be experienced, distress due to fatigue, daily fatigue degree, and fatigue timing at the last week by dimension. 2. There was the significant difference in the number of fatigue-regulating behaviors between rheumatoid of fatigue arthritic patients(9.37 times) and normal persons (8.15 times), but there wasn't any significant difference in the efficiency between rheumatoid arthritic patients(2.85 points) and normal persons (2.78 points) This research suggests two kinds of things as follows : 1. It is necessary to develop an educational program for improving efficiency of fatigue-regulating behaviors as well as some nursing arbitration measures for reducing fatigue of rheumatoid arthritic patients. 2. It is necessary for the future studies to continuously grasp characteristics of fatigue by gender variable by selecting more rheumatoid arthritic male patients.

  • PDF

Characteristics and Nursing Activities of Severe Trauma Patients Regarding the Main Damaged Body Parts (중증외상환자의 주 손상 부위별 특성과 간호활동)

  • Kim, Myung Hee;Kim, Myung Hee;Park, Jung Ha
    • Journal of Korean Biological Nursing Science
    • /
    • v.15 no.4
    • /
    • pp.210-218
    • /
    • 2013
  • Purpose: The purpose of this study was to identify the characteristics and nursing activities of severe trauma patients regarding damaged body parts in Busan Regional Emergency Medical Center. Methods: A survey using a 'trauma patient information questionnaire and a list of nurse activities' was conducted with 133 patients over 15 points ISS on EMR from June 1, 2011 to May 31, 2012. The collected data were analyzed by the SPSS/WIN 12.0 program. Results: Almost all of the subjects were men, and the mean age was 48.8. The amount of road traffic accidents was 60.4%, and the mean RTS and ISS were 6.08, and 23.14 points. Nursing activities in common were airway management, assessment of LOC & GCS, and EKG monitoring. Most of head and neck trauma patients were cared for manasing using intracranial pressure: each patience had the following assessed: pupil size and light reflex, they were checked the leak of CSF, kept $30^{\circ}$ head elevation, and administered medications. Some of chest trauma patients were treated for chest tube and central venous catheter insertion. Partial abdominal trauma patients were administered analgesic and cared for using arterial pressure measurement. Part of the limbs and pelvis trauma patients were given a blood transfusion. Conclusion: Based on the results, the characteristics and nursing activities were specific according to the specific damaged body parts.

Structural health monitoring of high-speed railway tracks using diffuse ultrasonic wave-based condition contrast: theory and validation

  • Wang, Kai;Cao, Wuxiong;Su, Zhongqing;Wang, Pengxiang;Zhang, Xiongjie;Chen, Lijun;Guan, Ruiqi;Lu, Ye
    • Smart Structures and Systems
    • /
    • v.26 no.2
    • /
    • pp.227-239
    • /
    • 2020
  • Despite proven effectiveness and accuracy in laboratories, the existing damage assessment based on guided ultrasonic waves (GUWs) or acoustic emission (AE) confronts challenges when extended to real-world structural health monitoring (SHM) for railway tracks. Central to the concerns are the extremely complex signal appearance due to highly dispersive and multimodal wave features, restriction on transducer installations, and severe contaminations of ambient noise. It remains a critical yet unsolved problem along with recent attempts to implement SHM in bourgeoning high-speed railway (HSR). By leveraging authors' continued endeavours, an SHM framework, based on actively generated diffuse ultrasonic waves (DUWs) and a benchmark-free condition contrast algorithm, has been developed and deployed via an all-in-one SHM system. Miniaturized lead zirconate titanate (PZT) wafers are utilized to generate and acquire DUWs in long-range railway tracks. Fatigue cracks in the tracks show unique contact behaviours under different conditions of external loads and further disturb DUW propagation. By contrast DUW propagation traits, fatigue cracks in railway tracks can be characterised quantitatively and the holistic health status of the tracks can be evaluated in a real-time manner. Compared with GUW- or AE-based methods, the DUW-driven inspection philosophy exhibits immunity to ambient noise and measurement uncertainty, less dependence on baseline signals, use of significantly reduced number of transducers, and high robustness in atrocious engineering conditions. Conformance tests are performed on HSR tracks, in which the evolution of fatigue damage is monitored continuously and quantitatively, demonstrating effectiveness, adaptability, reliability and robustness of DUW-driven SHM towards HSR applications.

Developing Pattern Identification Questionnaire of Allergic Rhinitis (알레르기 비염의 변증을 위한 설문문항 개발)

  • Kim, Min-Hee;Yun, Young-Hee;Ahn, Jin-Hyang;Ko, Seoung-Gyu;Choi, In-Hwa
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.30 no.2
    • /
    • pp.112-125
    • /
    • 2017
  • Objectives : The prevalence of allergic rhinitis (AR) is 10-40% worldwide and there are many demands for Traditionl Medicine (TM) treatment for AR. Pattern identification (PI) is essential process in diagnosis and treatment of TM, however, objective assessment measurement for PI of AR in TM is lacked. Methods : PI questionnaire for AR was developed in 2008 by specialists in the department of Otolaryngology of TM, based on systemic and nasal symptoms and signs. However, that questionnaire had many problems in application to clinical practice and has since been revised based on several studies and delphi method. Consequently, the PI questionnaire for AR version 3.0 has been developed. Results & Conclusions : This questionnaire classifies patients with AR as possessing lung-heat, lung-cold, or spleen qi deficiency based on nasal symptoms and general conditions of AR patients. This is first questionnaire for pattern identification of AR. We plan to conduct a validation and reliability study, and revise the questionnaire based on the results of this study.

Brassiere Pattern Development Based on 3D Measurements of Upper Body Types for Women in Their 40's (3차원 인체 측정을 이용한 40대 여성의 상반신 체형을 고려한 브래지어 패턴 개발)

  • Cho, Shin-Hyun;Kim, Mi-Sook
    • The Research Journal of the Costume Culture
    • /
    • v.16 no.3
    • /
    • pp.502-517
    • /
    • 2008
  • The purpose of the study lies in the measurements of breast shapes and upper body types for the women in their 40's, with the use of 3D measurement system, and in the presentation of brassiere patterns fit for their body types. As for the study method, 3D human body types were analyzed with RapidForm 2006, and the upper-body types and breast shapes were statistically classified through technical statistics analysis, cluster analysis, t-test, variance analysis, and cross analysis. The wearing tests went through the comparison of the brassieres of three makers in the market and the experiment brassieres(first and second) and then the evaluations were made by the subjects, the outer appearance assessment by experts, and 3D measurements. The findings of the study indicated that the evaluation of experiment brassieres was excellent in every item, and he significant difference was found out particularly in the items of pressure, rear center, front center, breast underneath, adequate level by wing, and adequate level by armhole. According to the results of 3D evaluation, experiment brassieres had a highest point in fitness with no physical pressure at the wing part and no overall deviation at the cup art. The pattern comparison showed the differences in the parts of total cup angle, cup circumference length, lower cup height, wing length, and wing angle.

  • PDF

Brassiere Pattern Development Based on 3D Measurements of Upper Body - Focused on Women in Their 30's - (3차원 인체 계측 방법에 의한 상반신 체형을 고려한 브래지어 패턴 설계 - 30대를 대상으로 -)

  • Cho, Shin-Hyun;Kim, Mi-Sook
    • The Research Journal of the Costume Culture
    • /
    • v.16 no.3
    • /
    • pp.488-501
    • /
    • 2008
  • The purpose of this study presents bra pattern using the 3D measurements of the upper body subject to women in their 30's. Brassieres available in the market are mostly designed for straight body shape and many women seem to have experienced bearing discomfort in a great extent as they grow older. Brassieres should be designed to cover diverse body types and the accurate measurement of body type and breast shape is needed to accomplish that. As for the study method, 3D human body types were analyzed with RapidForm 2006, and the upper-body types and breast shapes were statistically classified through technical statistics analysis, cluster analysis, t-test, variance analysis, and cross analysis. The wearing tests went through the comparison of the brassieres of three makers in the market and the experiment brassieres(first and second) and then the evaluations were made by the subjects, the outer appearance assessment by experts, and 3D measurements. The results of this study showed that the evaluation of experiment brassieres was excellent in every item, and the significant difference was found out particularly in the items of pressure, rear center, front center, breast underneath, adequate level by wing, and adequate level by armhole. According to the results of 3D evaluation, experiment brassieres had a highest point in fitness with no physical pressure at the wing part and no overall deviation at the cup part.

  • PDF

Preoperative Korean Shoulder Scoring System Correlates with Preoperative Factors of Rotator Cuff Tears

  • Kim, Eun-Yeol;Park, Byung-Yoon;Kim, In-Bo
    • Clinics in Shoulder and Elbow
    • /
    • v.21 no.1
    • /
    • pp.30-36
    • /
    • 2018
  • Background: The Korean Shoulder Scoring System (KSS) is a reliable and valid procedure for discriminative assessment of the clinical status of patients with rotator cuff tears. This study evaluates the correlation between the preoperative KSS and factors in patients with rotator cuff tears. Methods: From November 2009 to June 2016, 970 patients who underwent arthroscopic rotator cuff repair were retrospectively evaluated. A total of 490 patients met the study criteria. Preoperative factors included age, sex, symptom duration, mediolateral (ML) and anteroposterior (AP) tear size, acromiohumeral distance (AHD), tangent sign, tendon involvement (type I, supraspinatus; type II, supraspinatus and subscapularis; type III, supraspinatus and infraspinatus; type IV, all 3 tendons), fatty infiltration of rotator cuff muscles (group I, Goutallier stages 0 and 1; group II, Goutallier stages 2, 3, and 4), and KSS. Results: Old age, ML tear size, and AP tear size negatively correlated with the preoperative KSS (p<0.001). AHD showed a positive correlation with the preoperative KSS (p<0.001). A significantly inferior preoperative KSS was found in females and type III tendon involvement (p<0.001). For supraspinatus and infraspinatus, the preoperative KSS of group II fatty infiltration showed a significantly lower score than group I fatty infiltration (p<0.05). Conclusions: A relatively lower preoperative KSS was associated with old age, large tear size, narrow AHD, female, type III tendon involvement, and group II fatty infiltration of the supraspinatus and infraspinatus. Our study indicates that preoperative KSS can be a good measurement for the preoperative status of patients with rotator cuff tears.

Rice bran fermentation by lactic acid bacteria to enhance antioxidant activities and increase the ferulic acid, ρ-coumaric acid, and γ-oryzanol content

  • Le, Bao;Anh, Pham Thi Ngoc;Kim, Jung-Eun;Cheng, Jinhua;Yang, Seung Hwan
    • Journal of Applied Biological Chemistry
    • /
    • v.62 no.3
    • /
    • pp.257-264
    • /
    • 2019
  • Rice bran is considered a natural source of antioxidants. In this study, rice bran was fermented with lactic acid bacteria to increase its antioxidant activity. Four strains isolated from fermented food, Lactobacillus plantarum MJM60383, Lactococcus lactis subsp. lactis MJM60392, Lactobacillus fermentum MJM60393, and Lactobacillus paracasei MJM60396, were confirmed as safe through stability tests such as safety assessment for biogenic amine production, hemolytic activity, and mucin degradation, and showed high reducing capacity. The antioxidant activity of rice bran fermentation altered by these strains was evaluated using several methods including measurement of $Fe^{2+}$ chelating activity and scavenging activity by 1,1-diphenyl-2-picryl-hydrazil (DPPH), 2,2'-azinobis-(3-ethylbenzothiazoline-6-sulfonic acid) (ABTS), and nitric oxide assays. In this study, the total phenolic content and ${\gamma}$-oryzanol were evaluated by high-performance liquid chromatography. Compared to non-fermented rice bran and a commercial product, rice bran fermented with Lactococcus lactis subsp. lactis MJM60392 showed the highest phenolic content (844.13 mg GAE/g). Moreover, the content of ferulic acids, ${\rho}$-coumaric acid, and ${\gamma}$-oryzanol in rice bran increased after fermentation with L. lactis subsp. lactis MJM60392 and L. fermentum MJM60393 compared to other samples. Indeed, the DPPH radical scavenging activity and NO scavenging activity were also found to be high in these fermented rice brans. These results indicated that fermentation with lactic acid bacteria increases the active compound levels and the potent antioxidant activities of rice bran.

Force Assessment of Thermoformed and Direct-printed Aligners in a Lingual Bodily Movement of a Central Incisor Over Time: A 14-day In Vitro Study

  • Mary Linda Remley;Gabriel Ferreira Pessoa Carvalho Miranda ;Brent Bankhead;Julie McCray;Ki Beom Kim
    • Journal of Korean Dental Science
    • /
    • v.16 no.1
    • /
    • pp.23-34
    • /
    • 2023
  • Purpose: This study aims to investigate the force delivery profile of thermoformed aligners (TFA) compared with direct-printed aligners (DPA) and to explore the effect of different activation amounts on forces and moments of respective groups. A secondary objective is to observe the amount of stress relaxation that occurs over the 7~14 days when aligners are maintained in a simulated intraoral environment. Materials and Methods: An in vitro setup was created to quantify forces and moments. It consisted of a three dimensional-printed base plate and segmented maxillary teeth, placed in a semi-enclosed chamber to maintain a temperature of 37℃. Ninety clear aligners were divided into nine groups of ten aligners each based on material types (Zendura, ATMOS, TC-85) and activation amounts. Aligners were created with 0.00, 0.25- and 0.50-mm activations for lingual bodily movement of the upper left central incisor and kept on models in the "stressed" position in a 37℃ water bath. Three force components acting on the upper left lateral incisor, upper left central incisor, and upper right central incisor were measured for each time point, beginning from the initial baseline measurement, 8 hours, 16 hours, 24 hours, 2 days, 3 days, 4 days, 5 days, 6 days, 7 days, and lastly, 14 days. Result: TC-85 aligners in every activation group showed less force on teeth than Zendura and ATMOS. Significant force levels from 0.0 mm activation were present and stayed consistent over the course of 14 days. Comparisons made for baseline measurements to 7-days and 14-days showed statistically significant change from the baseline force level. Conclusion: TC-85 aligners demonstrated lower, more consistent forces with fewer side effects. Aligners can generate forces even when no activation is programmed. No major decreases in force levels over time were observed; the intra-oral clinical simulated environment and length of observation time could contribute to this.