Measurement of Photo-Neutron Dose from an 18-MV Medical Linac Using a Foil Activation Method in View of Radiation Protection of Patients

  • Yucel, Haluk;Cobanbas, Ibrahim;Kolbasi, Asuman;Yuksel, Alptug Ozer;Kaya, Vildan
    • Nuclear Engineering and Technology
    • /
    • v.48 no.2
    • /
    • pp.525-532
    • /
    • 2016
  • High-energy linear accelerators are increasingly used in the medical field. However, the unwanted photo-neutrons can also be contributed to the dose delivered to the patients during their treatments. In this study, neutron fluxes were measured in a solid water phantom placed at the isocenter 1-m distance from the head of an18-MV linac using the foil activation method. The produced activities were measured with a calibrated well-type Ge detector. From the measured fluxes, the total neutron fluence was found to be $(1.17{\pm}0.06){\times}10^7n/cm^2$ per Gy at the phantom surface in a $20{\times}20cm^2$ X-ray field size. The maximum photo-neutron dose was measured to be $0.67{\pm}0.04$ mSv/Gy at $d_{max}=5cm$ depth in the phantom at isocenter. The present results are compared with those obtained for different field sizes of $10{\times}10cm^2$, $15{\times}15cm^2$, and $20{\times}20cm^2$ from 10-, 15-, and 18-MV linacs. Additionally, ambient neutron dose equivalents were determined at different locations in the room and they were found to be negligibly low. The results indicate that the photo-neutron dose at the patient position is not a negligible fraction of the therapeutic photon dose. Thus, there is a need for reduction of the contaminated neutron dose by taking some additional measures, for instance, neutron absorbing-protective materials might be used as aprons during the treatment.

The Effects of Scapular Stabilization Exercise before Rotator Cuff Repair on Pain and ROM of Middle-aged Women (중년여성의 가시위근 봉합술전 어깨뼈 안정화운동이 통증과 ROM향상에 미치는 영향)

  • Kim, Taeyeob;Yoo, Byungkook
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.2 no.1
    • /
    • pp.63-76
    • /
    • 2014
  • Purpose : The purpose of this study was to ascertain the effects of scapular stabilization exercise before rotator cuff surgery on pain and range of motion of middle-aged women. Method : 20 subjects who agreed on this experiment and were diagnosed with rotator cuff rupture participated in this study. Experimental groups were treated while 40 minutes a day, 5 times per week, for 2 weeks before surgery. The effects of scapular stabilization exercise were evaluated on VAS and range of motion. Collected data were analyzed with SPSS for windows ver. 20.0 program. One-way repeated ANOVA was used to examine a significance of each variable by time. Two-way repeated ANOVA was applied to examine a significance of the experimental group against the control group. In all statistical tests, the significance level was set by ${\alpha}=.05$. Result : The results of this study are as follows: 1) In both control and experimental groups, VASs were decreased significantly according to intervention period. There was no significant difference between VASs of two groups. 2) In both control and experimental groups, ROMs of shoulder, flexion, abduction and external rotation were increased significantly according to intervention period. In these three flexibility measurement variables, there were significant differences between ROMs of two groups. Conclusion : In view of all the results in this study, scapular stabilization exercise on before rotator cuff surgery proved to be effective in improving their pain, range of motion after surgery. It will be sufficient data to perform with their own exercise program.

Development of Strain-gauge-type Rotational Tool Dynamometer and Verification of 3-axis Static Load (스트레인게이지 타입 회전형 공구동력계 개발과 3축 정적 하중 검증)

  • Lee, Dong-Seop;Kim, In-Su;Lee, Se-Han;Wang, Duck-Hyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.9
    • /
    • pp.72-80
    • /
    • 2019
  • In this task, the tool dynamometer design and manufacture, and the Ansys S/W structural analysis program for tool attachment that satisfies the cutting force measurement requirements of the tool dynamometer system are used to determine the cutting force generated by metal cutting using 3-axis static structural analysis and the LabVIEW system. The cutting power in a cutting process using a milling tool for processing metals provides useful information for understanding the processing, optimization, tool status monitoring, and tool design. Thus, various methods of measuring cutting power have been proposed. The device consists of a strain-gauge-based sensor fitted to a new design force sensing element, which is then placed in a force reduction. The force-sensing element is designed as a symmetrical cross beam with four arms of a rectangular parallel line. Furthermore, data duplication is eliminated by the appropriate setting the strain gauge attachment position and the construction of a suitable Wheatstone full-bridge circuit. This device is intended for use with rotating spindles such as milling tools. Verification and machining tests were performed to determine the static and dynamic characteristics of the tool dynamometer. The verification tests were performed by analyzing the difference between strain data measured by weight and that derived by theoretical calculations. Processing test was performed by attaching a tool dynamometer to the MCT to analyze data generated by the measuring equipment during machining. To maintain high productivity and precision, the system monitors and suppresses process disturbances such as chatter vibration, imbalances, overload, collision, forced vibration due to tool failure, and excessive tool wear; additionally, a tool dynamometer with a high signal-to-noise ratio is provided.

Quickly Map Renewal through IPM-based Image Matching with High-Definition Map (IPM 기반 정밀도로지도 매칭을 통한 지도 신속 갱신 방법)

  • Kim, Duk-Jung;Lee, Won-Jong;Kim, Gi-Chang;Choi, Yun-Soo
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.5_1
    • /
    • pp.1163-1175
    • /
    • 2021
  • In autonomous driving, road markings are an essential element for object tracking, path planning and they are able to provide important information for localization. This paper presents an approach to update and measure road surface markers with HD maps as well as matching using inverse perspective mapping. The IPM removes perspective effects from the vehicle's front camera image and remaps them to the 2D domain to create a bird-view region to fit with HD map regions. In addition, letters and arrows such as stop lines, crosswalks, dotted lines, and straight lines are recognized and compared to objects on the HD map to determine whether they are updated. The localization of a newly installed object can be obtained by referring to the measurement value of the surrounding object on the HD map. Therefore, we are able to obtain high accuracy update results with very low computational costs and low-cost cameras and GNSS/INS sensors alone.

A Study on the Correlationship between Wearable ECG and Clinical ECG Measurements (웨어러블 심전도 측정과 임상 심전도 측정과의 상관관계에 대한 연구)

  • Lee, Kang-Hwi;Lee, Seong-Su;Kim, Sang-Min;Lee, Hyeok-Jae;Min, Kyoung-Jin;Kang, Hyun-Kyu;Lee, Joo-Hyeon;Kwak, Hwy-Kuen;Ko, Yun-Soo;Lee, Jeong-Whan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.12
    • /
    • pp.1690-1698
    • /
    • 2018
  • Recent advances in ICT technology have transformed many of our daily lives and attracted a lot of attention to personal health. Heart beat measurement that reflects cardiac activities has been used in various fields such as exercise evaluation and psychological state evaluation for a long time, but its utilization method is limited due to its differentiation from clinical electrocardiogram. Therefore, in this study, we could observe the change of the measured signal according to the change of the distance and the position of the measuring electrodes which are non-standard electrode configuration. Based on the electric dipole model of the heart, correlation with clinical electrocardiogram could be confirmed by synthesizing multiple surface potentials measured with a shorter electrode distance than standard one. From the electromagnetic point of view, the distance between the measuring electrodes corresponds to the distance that the electric potential by the cardiac electric dipole moves, and the electric potential measured at the body surface is proportional to the moving distance of the electric potential. Therefore, it is preferable to make the distance between electrodes as long as possible, and to position the measuring electrode close to the ventricle rather than the atrium. In addition, it was found that standard electrocardiographic waveforms could be synthesized by using arithmetic sum of multiple measuring electrodes due to the relationship of electrical dipole vectors, which is obtained by dividing and positioning a plurality of measuring electrodes on a reference electrode line, such as Lead-I, Lead-II direction. Also, we obtained a significant Pearson correlation coefficient ($r=0.9113{\pm}0.0169$) as a result of synthetic experiments on four subjects.

Image Sensor Module for Detecting Space Illuminance in Indoor Environment (실내 환경의 공간조도 검출을 위한 이미지센서모듈)

  • Moon, Seong-Jae;Lim, Yeong-Seog
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.7
    • /
    • pp.771-778
    • /
    • 2019
  • The traditional illuminance intensity detection method using a single sensor has a problem that uniformity of illuminance detection is deteriorated depending on the measurement position due to the narrow FOV characteristic. In order to overcome this problem, a method of detecting an average illuminance value through a plurality of illuminance sensors is used, but the complexity and detection error are increased. In this paper, we propose a illuminance intensity detection method based on a single image sensor with wide FOV. The proposed method can solve the problems such as system complexity and error increase of existing illuminance sensor. The test results show that the difference of average value is 12% using a illuminance sensor, 10.7% using five illuminance sensors, and 6.2% using an image sensor compared with the reference value using the color difference illuminometer. It is confirmed that the proposed method can easily and accurately detect the space illuminance with improved uniformity.

The Standard Processing of a Time Series of Imaging Spectral Data Taken by the Fast Imaging Solar Spectrograph on the Goode Solar Telescope

  • Chae, Jongchul;Kang, Juhyeong;Cho, Kyuhyoun
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.43 no.2
    • /
    • pp.46.1-46.1
    • /
    • 2018
  • The Fast Imaging Solar Spectrograph (FISS) on the Goode Solar Telescope (GST) at Big Bear Solar Observatory is the imaging Echelle spectrograph developed by the Solar Astronomy Group of Seoul National University and the Solar and Space Weather Group of Korea Astronomy and Space Science Institute. The instrument takes spectral data from a region on the Sun in two spectral bands simultaneously. The imaging is done by the organization of intensity data obtained from the fast raster scan of the slit over the field of view. Since the scan repeats many times, the whole set of data can be used to construct the movies of monochromatic intensity at arbitrary wavelengths within the spectral bands, and those of line-of-sight velocity inferred from different spectral lines. So far there are two standard observing configurations: one recording the $H{\alpha}$ line and the Ca II 8542 line simultaneously, and the other recording the Na I D2 line and Fe I 5435 line simultaneously. We have developed the procedures to produce the standard data for each observing configuration. The procedures include the spatial alignment, the correction of spectral shift of instrumental origin, and the lambdameter measurement of the line wavelength. The standard data include the movie of continuum intensity, the movies of intensity and velocity inferred from a chromospheric spectral line, the movies of intensity and velocity inferred from a photospheric line. The processed standard data will be freely available online (fiss.snu.ac.kr) to be used for research and public outreach. Moreover, the IDL procedures will be provided on request as well so that each researcher can adapt the programs for their own research.

  • PDF

Walkability Evaluation for Elderly People using Wearable Sensing (웨어러블 센싱 기반 고령자를 위한 보행 편의성 평가)

  • Yang, Kanghyeok;Hwang, Sungjoo;Kim, Hyunsoo
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.35 no.7
    • /
    • pp.119-126
    • /
    • 2019
  • The active living of the elderly leads to improve their lives and enhance social networks. In the view of the active living, the walkability is an essential factor for the elderly's daily life. To support the active living, making age-friendly environment is important. Considering that the elderly mainly carry out activities through walking, making the age-friendly walking environment is a preliminary action. The existing studies applied various methods such as surveys by experts. In spite of the benefits in theirs, there is still a limitation that current walkability measurement methods did not incorporate the actual elderly's walking activity. Thus, the purposes of this study is to measure the elderly's walking quantitatively using a wearable sensor, and to investigate the feasibility of comparing several walking environments based on the data collected from the actual elderly's walking. To do this, experiment was conducted in four types environments with 22 senior subjects. The walkability was measured by walking stability represented quantitatively as Maximum Lyapunov Exponent (MaxLE). Through the experiment results, it was confirmed that the stability of the elderly walking was different according to the walking environment, which also meant that bodily responses (walking stability) is highly related to walkability. The results will provide an opportunity for the continuous diagnosis of walking environments, thereby enhancing the active living of the elderly.

Loitering Behavior Detection Using Shadow Removal and Chromaticity Histogram Matching (그림자 제거와 색도 히스토그램 비교를 이용한 배회행위 검출)

  • Park, Eun-Soo;Lee, Hyung-Ho;Yun, Myoung-Kyu;Kim, Min-Gyu;Kwak, Jong-Hoon;Kim, Hak-Il
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.21 no.6
    • /
    • pp.171-181
    • /
    • 2011
  • Proposed in this paper is the intelligent video surveillance system to effectively detect multiple loitering objects even that disappear from the out of camera's field of view and later return to a target zone. After the background and foreground are segmented using Gaussian mixture model and shadows are removed, the objects returning to the target zone is recognized using the chromaticity histogram and the duration of loitering is preserved. For more accurate measurement of the loitering behavior, the camera calibration is also applied to map the image plane to the real-world ground. Hence, the loitering behavior can be detected by considering the time duration of the object's existence in the real-world space. The experiment was performed using loitering video and all of the loitering behaviors are accurately detected.

A Study on Establishment of Basic Safety and Essential Performance Criteria of Mobile Computed Tomography (이동형 전산화단층촬영장치의 기본 안전 및 필수 성능 기준을 마련하기 위한 연구)

  • Kim, Eun Hye;Park, Hye Min;Kim, Jung Min
    • Journal of radiological science and technology
    • /
    • v.44 no.3
    • /
    • pp.261-267
    • /
    • 2021
  • As the number of Coronavirus Disease-19 (COVID-19) patients increases in a global pandemic situation, the usefulness of mobile computed tomography (CT) is gaining attention. Currently, mobile CT follows the basic safety and essential performance evaluation criteria of whole-body or limited-view X-ray CT in order to obtain device approval and evaluation in the Republic of Korea. Unlike stationary CT, mobile CT is not operated in shielded areas but rather areas such as intensive care units, operating rooms, or isolation rooms. Therefore, it requires a different basic safety and essential performance evaluation standard than stationary CT. In this study, four derived basic safety evaluation criteria related to electrical, mechanical, and radiation safety were included (dose indication test, protection against stray radiation, safety measures against excessive X-rays, half-value layer measurement); and seven essential performance evaluation criteria were included (tube voltage accuracy, mAs accuracy, radiation dose reproducibility, CT number of water, noise, uniformity, and spatial resolution); total eleven basic safety and essential performance evaluation criteria were selected. This study aims to establish appropriate basic safety and essential performance evaluation criteria for simultaneously obtaining images with diagnostic value and reducing the exposure of nearby patients, medical staff, and radiologic technologists during the use of mobile CT.