• Title/Summary/Keyword: Measurement View

Search Result 942, Processing Time 0.025 seconds

Image-based Modeling by Minimizing Projection Error of Primitive Edges (정형체의 투사 선분의 오차 최소화에 의한 영상기반 모델링)

  • Park Jong-Seung
    • The KIPS Transactions:PartB
    • /
    • v.12B no.5 s.101
    • /
    • pp.567-576
    • /
    • 2005
  • This paper proposes an image-based modeling method which recovers 3D models using projected line segments in multiple images. Using the method, a user obtains accurate 3D model data via several steps of simple manual works. The embedded nonlinear minimization technique in the model parameter estimation stage is based on the distances between the user provided image line segments and the projected line segments of primitives. We define an error using a finite line segment and thus increase accuracy in the model parameter estimation. The error is defined as the sum of differences between the observed image line segments provided by the user and the predicted image line segments which are computed using the current model parameters and camera parameters. The method is robust in a sense that it recovers 3D structures even from partially occluded objects and it does not be seriously affected by small measurement errors in the reconstruction process. This paper also describesexperimental results from real images and difficulties and tricks that are found while implementing the image-based modeler.

A Study on the Proper Chest Exposure Conditions of Mobile Digital X-ray Unit by Exposure Index (Exposure Index를 이용한 이동형 디지털 X선 장치의 흉부촬영 적정노출조건에 관한 연구)

  • Kim, Jae-In;Lee, Yang-Sub;Jang, Dong-Soo;Jung, Min-Cheol;Bae, Seung-Ho;Lee, Kwan-Sub;Ha, Dong-Yoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.3
    • /
    • pp.139-144
    • /
    • 2011
  • The purpose of this report is recommending a standard indicator which reflects the radiation exposure that is incident on a detector after every exposure event and that reflects the noise levels present in the image data. The experiment was performed with mobile digital X-ray unit and used a acrylic phantom for exposure index measurement. Exposure modality was kVp, mAs, SID. After every exposure, make a data sheet for characteristic curve of detector response. The equipment performed Mobile digital X-ray unit provide the user with values ralated to the incident exposure(air kerma)to the digital detector. They are showed as a logarithmic function shaped. As a result, DEI means a relative measure of exposure to the detector, as compared to the expected exposure for a particular anatomical view. Radiographic technique is the combination of factors used to exposure an anatomical part to produce a high quality radiography and technique charts used most commonly by radiographers to produce consistently exposure level which patient dose can be kept acceptably low.

  • PDF

Visibility Evaluation for Agricultural Tractor Operators According to ISO 5006 and 5721-1 Standards

  • Kabir, Md. Shaha Nur;Song, Mingzhang;Chung, Sun-Ok;Kim, Yong-Joo;Kim, Su-Chul;Ha, Jong-Kyou
    • Journal of Biosystems Engineering
    • /
    • v.40 no.1
    • /
    • pp.19-27
    • /
    • 2015
  • Purpose: A system to measure the visibility of agricultural tractor operators was designed and evaluated according to ISO standards, and a blind area diagram around the tested tractor was created based on the manual method recommended by the National Institute for Occupational Safety and Health (NIOSH). Methods: A visibility measurement system was designed and evaluated based on the ISO 5006 and ISO 5721-1 standards. Two bulbs used to simulate the operator's eyes were mounted on a bar with a supporting frame. A wooden frame was used to determine the seat index point position. The 12-m visibility test circle was divided into six sectors of vision, and the test tractor was placed at the center of the circle. Artificial light was supplied in the darkened environment, and shadow or masking effects were measured manually around the 12-m circle. Results: When the bulbs were placed at the operator's eye level, front visibility was good; no masking was found in the "A" vision sector, but larger masking widths were found in the "B" and "C" vision sectors. Since the masking width exceeded 700 mm, additional tests, such as movement of the light sources to both sides of the operator's eye level, were performed. Less than six masking effects were found in the semi-circle of vision to the front, and more than one masking was found in the "B" and "C" visual fields. The minimum distance between the centers of two masking effects exceeded 2500 mm when measured as a chord on the semi-circle of vision. A blind area diagram was created to define the exact nature of the blind spots and mirror visibility. Conclusions: Visibility evaluation is an effective way to enable proper and safe operation for agricultural tractor operators. Inclusion of this visibility evaluation test in the general testing process might aid tractor manufacturers.

Anaerobic Biodegradation of Lignin by BMP Test and Measurement of Lignin-derived Compound Using GC & GC/MS (BMP법에 의한 리그닌의 혐기성 분해 및 GC와 GC/MS을 이용한 리그닌 분해산물 측정)

  • Kim, Seog-Ku
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.16 no.3
    • /
    • pp.46-51
    • /
    • 2008
  • The traditional view of the fate of lignin under anaerobic conditions is that it is recalcitrant because molecular oxygen is required for depolymerization. The presence of lignin is apparently the most important factor affecting the biodegradability of ligneous materials. The initial step in the degradation of ligneous material to smaller intermediates is catalyzed by enzymes secreted by microorganisms and is generally regarded as the rate limiting step in the microbial mineralization of organic matter. Biochemical methane potential (BMP) test, typically used to assess anaerobic biodegradability of liquid wastes with added nutrients and bacteria, have been adapted to assess initial biodegradation of ligneous material under anaerobic conditions. A method based on selective inhibition of microorganism activity, by 3% toluene, has been used to measure using the initial degradation rate of ligneous material and the accumulation of lignin-derived compounds.

  • PDF

Conceptual Design of a Solid State Telescope for Small scale magNetospheric Ionospheric Plasma Experiments

  • Sohn, Jongdae;Lee, Jaejin;Jo, Gyeongbok;Lee, Jongkil;Hwang, Junga;Park, Jaeheung;Kwak, Young-Sil;Park, Won-Kee;Nam, Uk-Won;Dokgo, Kyunghwan
    • Journal of Astronomy and Space Sciences
    • /
    • v.35 no.3
    • /
    • pp.195-200
    • /
    • 2018
  • The present paper describes the design of a Solid State Telescope (SST) on board the Korea Astronomy and Space Science Institute satellite-1 (KASISat-1) consisting of four [TBD] nanosatellites. The SST will measure these radiation belt electrons from a low-Earth polar orbit satellite to study mechanisms related to the spatial resolution of electron precipitation, such as electron microbursts, and those related to the measurement of energy dispersion with a high temporal resolution in the sub-auroral regions. We performed a simulation to determine the sensor design of the SST using GEometry ANd Tracking 4 (GEANT4) simulations and the Bethe formula. The simulation was performed in the range of 100 ~ 400 keV considering that the electron, which is to be detected in the space environment. The SST is based on a silicon barrier detector and consists of two telescopes mounted on a satellite to observe the electrons moving along the geomagnetic field (pitch angle $0^{\circ}$) and the quasi-trapped electrons (pitch angle $90^{\circ}$) during observations. We determined the telescope design of the SST in view of previous measurements and the geometrical factor in the cylindrical geometry of Sullivan (1971). With a high spectral resolution of 16 channels over the 100 keV ~ 400 keV energy range, together with the pitch angle information, the designed SST will answer questions regarding the occurrence of microbursts and the interaction with energetic particles. The KASISat-1 is expected to be launched in the latter half of 2020.

THE KOMPSAT- I PAYLOADS OVERVIEW

  • Paik, Hong-Yul;Park, Gi-Hyuk;Youn, Hyeong-Sik;Lee, Seunghoon;Woo, Sun-Hee;Shim, Hyung-Sik;Oh, Kyoung-Hwan;Cho, Young-Min;Yong, Sang-Soon;Lee, Sang-Gyu;Heo, Haeng-Pal
    • Proceedings of the KSRS Conference
    • /
    • 1998.09a
    • /
    • pp.301-306
    • /
    • 1998
  • Korea Aerospace Research Institute (KARI) is developing a Korea Multi-Purpose Satellite I (KOMPSAT-I) which accommodates Electro-Optical Camera (EOC), Ocean Scanning Multi-spectral Imager (OSMI), and Space Physics Sensor (SPS). The satellite has the weight of about 500kg and will be operated on the 10:50 AM sun-synchronized orbit with the altitude of 685 km. The satellite will be launched in 1999 and its lifetime is expected to be over 3 years. The main mission of EOC is the cartography to provide the images from a remote earth view for the production of 1/25000-scale maps of KOREA. EOC collects 510 ~ 730 nm panchromatic imagery with the ground sample distance(GSD) of 6.6 m and the swath width of 17 km by push broom scanning. EOC also can scan $\pm$45 degree across the ground track using body pointing method. The primary mission of OSMI is worldwide ocean color monitoring for the study of biological oceanography. It will generate 6 band ocean color images with 800 km swath width and 1km GSD by whiskbroom scanning. OSMI is designed to provide on-orbit spectral band selectability in the spectral range from 400 nm to 900 nm through ground command. This flexibility in band selection can be used for various applications and will provide research opportunities to support the next generation sensor design. SPS consists of High Energy Particle Detector (HEPD) and ionosphere Measurement Sensor (IMS). HEPD has missions to characterize the low altitude high-energy Particle environment and to study the effects of radiation environment on microelectronics. IMS measures densities and temperature of electrons in the ionosphere and monitors the ionospheric irregularities at the KOMPSAT orbit.

  • PDF

Radiographic Liver Size Evaluation after Portosystemic Shunts Ligation in 13 Cases

  • Hong, Sung-kyun;Kim, Hye-jin;Lee, Si-heon;Kim, Wan-hee;Kweon, Oh-kyeong;Jung, Joo-hyun;Yoon, Jung-hee;Choi, Min-cheol
    • Journal of Veterinary Clinics
    • /
    • v.34 no.3
    • /
    • pp.189-192
    • /
    • 2017
  • Thirteen dogs were diagnosed as congenital extrahepatic single PSS by intraoperative mesenteric portovenography or computed tomographic examination, repair surgery was performed by using an ameroid constrictor. Hepatic size was measured from the right lateral view using liver length/T11 length ratio. This measurement was performed on follow-up check of PSS ligation patients. Hepatic size parameter of pre-operative PSS patients is $4.13{\pm}0.13$ (range, 3.11-4.83). After surgery, hepatic size parameter of post-operative PSS patients is $4.79{\pm}0.19$ (range, 3.78- 5.93). Although follow-up periods varied 2 and 26 weeks, all patients showed increased liver size compared to that on pre-operative radiographs (P < 0.01). The increase rate was 1.01-1.46 times than those of preoperative radiographs. But in 5 patients, post hepatic liver size was small compared to the others, which showed low increase rate of body weight, total protein, albumin, and glucose level. It was thought that small value of hepatic size parameter was due to delay of hepatic regeneration. In conclusion, radiographic hepatic size parameter of pre- and post-operative patients is considered an effective evaluation for restoring after PSS surgery.

Evaluation of the Geum River by Multivariate Analysis: Principal Component Analysis and Factor Analysis (다변량분석법을 이용한 금강 유역의 수질오염특성 연구)

  • Kim, Mi-Ah;Lee, Jae-kwan;Zoh, Kyung-Duk
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.1
    • /
    • pp.161-168
    • /
    • 2007
  • The main aim of this work is focus on the Geum river water quality evaluation of pollution data obtained by monitoring measurement during the period 2001-2005. The complex data matrix 19 (entire monitoring stations)*13 (parameters), 60 (month)*13 (parameters) and 20 (season)*13 (parameters) were treated with different multivariate techniques such as factor analysis/principal component analysis (FA/PCA). FA/PCA identified two factor (19*13) classified pollutant Loading factor (BOD, COD, pH, Cond, T-N, T-P, $NH_3$-N, $NO_3$-N, $PO_4$-P, Chl-a), seasonal factor (water temp, SS) and three Factor (60*13, 20*13) classified pollutant Loading factor (BOD, COD, Cond, T-N, T-P, $NH_3$-N, $NO_3$-N, $PO_4$-P), seasonal factor (water temp, SS) and metabolic factor (Chl-a, pH). Loadings of pollutant factor is potent influence main factor in the Geum river which is explained by loadings of pollutant factor at whole sampling stations (71.16%), month (52.75%) and season (56.57%) of main water quality stations. Result of this study is that pollutant loading factor is affected at Gongju 1, 2, Buyeo 1, 2, Gangkyeong, Yeongi stations by entire stations and entire month (Gongju 1, Cheongwon stations), April, May, July and August (buyeo 1) by month. Also the pollutant Loading factor is season gives an influence in winter (Gongju 1, buyeo 1) from main sampling stations, but Cheongwon characteristic is non-seasonal influenced. This study presents necessity and usefulness of multivariate statistic techniques for evaluation and interpretation of large complex data set with a view to get better information data effective management of water sources.

Characteristics of Noise Emission from Wind Turbine Generator According to Methods of Power Regulation (파워 조절 방법에 따른 풍력 터번 발전기의 방사 소음 특성)

  • Jung, Sung-Soo;Cheung, Wan-Sup;Shin, Su-Hyun;Chun, Se-Jong;Choi, Yong-Moon;Cheong, Cheol-Ung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.941-945
    • /
    • 2006
  • In the development of electricity generating wind turbines for wind farm application, only two types have survived as the methods of power regulation; stall regulation and fun span pitch control. The sound measurement procedures of IEC 61400-11 are applied to field test and evaluation of noise emission from each of 1.5 MW and 660 kW wind turbine generators (WTG) utilizing the stall regulation and the pitch control for the power regulation, respectively. Apparent sound power level, wind speed dependence and third-octave band levels are evaluated for both of WTGs. It is found that while 1.5 MW WTG using the stall control is found to emit lower sound power than 660 kW one using the pitch control at low wind speed (below 8 m/s), sound power from the former becomes greater than that of the latter in the higher wind speed. Equivalent continuous sound pressure levels (ECSPL) of the stall control type of WTG vary more widely with wind speed than those of the pitch control type of WTG These characteristics are believed to be strongly dependent on the basic difference of the airflow around the blade between the stall regulation and the pitch control types of WTG. These characteristics according to the methods of power regulation lead to the very different noise emission characteristics of WTG depending on the seasons because the average wind speed in summer is lower than the critical velocity over which the airflow on the suction side of blade in the stall types of WT are separated. These results propose that, in view of environmental noise regulation, the developer of wind farm should give enough considerations to the choice of power regulation of their WTG based on the weather conditions of potential wind farm locations.

  • PDF

The Analysis of Ethanol Distribution Level in Biological Specimens (생체 시료중에서 Ethanol 농도 분포에 관한 연구)

  • Hong, Hoon-Gi;Kim, Dong-Wook
    • Analytical Science and Technology
    • /
    • v.11 no.3
    • /
    • pp.222-228
    • /
    • 1998
  • Five kinds of packed column and two kinds of capillary column were used to get optimum condition for ethanol analysis by using fifteen different volatile, low molecular weight organic substances. Only two columns, Gaskuropack 54 and DB-1, showed good separation efficiency. In the adding salt-effect experiment 0.6N - perchloric acid, 1M - meta-phosphoric acid and saturated NaCl solution were used for alcohol concentration measurement of biological fluids and tissue specimens. Among adding salt experiment, adding saturated NaCl solution showed the most stable value of alcohol concentration. This fact might be due to the increased vaporization of alcohol in the saturated NaCl solution. In the time-course of blood alcohol concentration, the alcohol level was lineary decreased to the diameter of vessel containing specimens. This result was interpreted in view of ethanol level, weight, water content, and hematocrit value. The ethanol distribution levels were measured from samples of blood and tissue obtained from 25 postmortems cases investigated by NISI. This study showed that the distribution level was decreased in order of brain, blood, kidney, spleen, liver, and lung.

  • PDF