• 제목/요약/키워드: Measurement Validation

검색결과 699건 처리시간 0.024초

풍동 조건의 마이크로폰 어레이 측정에서 전단층 보정에 관한 연구 (Study on Shear Layer Correction of Microphone Array Measurement in the Wind Tunnel Test)

  • 김위준;이욱;최종수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.92-96
    • /
    • 2007
  • Microphone array beamforming method has been recognized as an important aeroacoustic research field and become a standard technique in localizing sound sources. This method also used in flight acoustic measurement, and especially, it is very useful when measure sounds inside the wind tunnel. In measuring sound which is inside the wind tunnel by traditional beamforming method, there are some errors caused by airstream. The speed and the propagation path of the sound changes as it travel through the airstream. This makes the error which the position of sound is changed a little bit to the down stream direction. In this paper, validation test has made about the correction equation for this wind effects of previous researches. And beamforming including shear layer correction was performed about a sound source in the anechoic open-jet windtunnel.

  • PDF

비틀림 유도파를 이용한 근지표면 전단속도 규명 (Identification of the Shear Velocities of Near Surface Soils Using Torsional Guided Waves)

  • 박경조;오형수
    • 한국소음진동공학회논문집
    • /
    • 제22권8호
    • /
    • pp.771-776
    • /
    • 2012
  • A technique is presented that uses a circular waveguide for the measurement of the bulk shear(S-wave) velocities of unconsolidated, saturated media, with particular application to near surface soils. The technique requires the measurement of the attenuation characteristics of the fumdamental T(0,1) mode that propagates along an embedded pipe, from which the acoustic properties of the surrounding medium are inferred. From the dispersion curve analysis, the feasibility of using T(0,1) mode which is non-dispersive and have constant attenuation over all frequency range is discussed. The principles behind the technique are discussed and the results of an experimental laboratory validation are presented. The experimental data are best fitted for the different depths of wetted sand and the shear velocities as a function of depths are formulated using power law curves.

실시간 공정신호를 통한 용접공정 알고리즘에 관한 연구 (A Study on Welding Process Algorithm through Real-time Current Waveform Analysis)

  • 윤진영;이영민;신순철;최해운
    • Journal of Welding and Joining
    • /
    • 제33권4호
    • /
    • pp.24-29
    • /
    • 2015
  • The current waveform was analysed to monitor the weld quality in real time process. The acquired current waveform was discretely analysed for the top and bottom limits of peaks as well as the pulse frequency measurement. Fast Fourier Transform was implemented in the program to monitor the pulse frequency in real time. The developed algorithm or program was tested for the validation purpose. The cross-section of weld profile was compared to the current waveform profile to correlate the monitored signal and the actual parts. Pulse frequency was also used as auxiliary tool for the quality monitoring. Based on the results, it was possible to evaluate the quality of welding by measure the current waveform profile and frequency measurement.

진자검사 계측을 위한 영상 시스템의 개발 (Development of a Vision System for the Measurement of the Pendulum Test)

  • 김철승;문기욱;이수영;엄광문
    • 전기학회논문지
    • /
    • 제56권4호
    • /
    • pp.817-819
    • /
    • 2007
  • The purpose of this work is to develop a measurement system of the pendulum test with minimal restriction of experimental environment and little influence of noise. In this work, we developed a vision system without any line between markers and a camera. The system performance is little influenced by the experimental environment, if light are sufficient to recognize markers. For the validation of the system, we compared knee joint angle trajectories measured by the developed system and by the magnetic sensor system during the nominal pendulum test and the maximum speed voluntary knee joint rotation. The joint angle trajectories of the developed system during both tests matched well with those of the magnetic system. Therefore, we suggest the vision system as an alternative to the previous systems with limited practicality for the pendulum test.

AHP의 절대적 측정을 이용한 비대면 개인대출심사모형의 개발 (A Non Face-to-Face Private Loan Screening Model Employing the Ratings Approach of AHP : Development and Validation)

  • 민재형;김우섭
    • 경영과학
    • /
    • 제33권3호
    • /
    • pp.65-87
    • /
    • 2016
  • Being the FinTech technologies rapidly developed, the non face-to-face private loan market is also growing dramatically. While the real-world interests in this market are keen, the empirical studies on the issue are few compared to its prospective impact on credit loan market. This paper suggests a credit scoring model for the non face-to-face private loan employing the ratings approach (the absolute measurement method) of AHP. Analyzing a sample of data consisting of 460,000 transaction records over an 8-year period in the United States, we develop a scoring model for the non face-to-face private loan screening, and validate the model for the practical usage. Conducting sensitivity analysis, we suggest customized cut-off points for the loan execution to suit each individual loan institution's need.

공기 중 포름알데히드 측정을 위한 크로모트로핀산법과 DNPH/HPLC방법의 비교.평가 (Comparison of Chromotropic Acid Method and DNPH-HPLC Method for the Measurement of Formaldehyde in the Air)

  • 황윤정;박상곤;백성옥
    • 한국대기환경학회지
    • /
    • 제14권5호
    • /
    • pp.519-524
    • /
    • 1998
  • Formaldehyde is known to have adverse health effects, and is also found to be a product of atmospheric. photochemical reaction%. Several methods have been employed for the measurement of formaldehyde. Among them, two common methods are comparatively evaluated in this study, i.e. the chromotropic acid method and the HPLC method coupled with 2,4- dinitrophenylhydrazine (DNPH) derivatization of carbonyl compounds. Method evaluation and validation were performed with respect to repeatability, linearity, collection efficiency, and recovery efficiency. Comparison of formaldehyde concentrations measured simultaneously in the field using the two (n=20) and 35.8%, respectively. Overall, the measured levels by chromotropic acid method appeared to ice significantly higher than those by DNPH-HPLC method, indicating a positive interference due to the other aldehydes collected together with formaldehyde.

  • PDF

풍동 조건의 마이크로폰 어레이 측정에서 전단층 보정에 관한 연구 (Study on Shear Layer Correction of Microphone Array Measurement in the Wind Tunnel Test)

  • 김위준;이욱;최종수
    • 한국소음진동공학회논문집
    • /
    • 제18권6호
    • /
    • pp.612-618
    • /
    • 2008
  • Microphone array beamforming method has been recognized as an important aeroacoustic research field and become a standard technique in localizing sound sources. This method also used in flight acoustic measurement, and especially, it is very useful when measure sounds inside the wind tunnel. In measuring sound which is inside the wind tunnel by traditional beamforming method, there are some errors caused by airstream. The speed and the propagation path of the sound changes as it travel through the airstream. This makes the error which the position of sound is changed a little bit to the down stream direction. In this paper, validation test has made about the correction equation for this wind effects of previous researches. And beamforming including shear layer correction was performed about a sound source in the anechoic open-jet wind tunnel.

Prediction of Chemical Compositions for On-line Quality Measurement of Red Pepper Powder Using Near Infrared Reflectance Spectroscopy (NIRS)

  • Lee, Sun-Mee;Kim, Su-Na;Park, Jae-Bok;Hwang, In-Kyeong
    • Food Science and Biotechnology
    • /
    • 제14권2호
    • /
    • pp.280-285
    • /
    • 2005
  • Applicability of near infrared reflectance spectroscopy (NIRS) was examined for quality control of red pepper powder in milling factories. Prediction of chemical composition was performed using modified partial least square (MPLS) techniques. Analysis of total 51 and 21 red pepper powder samples by conventional methods for calibration and validation, respectively, revealed standard error of prediction (SEP) and correlation coefficient ($R^2$) of moisture content, ASTA color value, capsaicinoid content, and total sugar content were 0.55 and 0.90, 8.58 and 0.96, 31.60 and 0.65, and 1.82 and 0.86, respectively; SEP and $R^2$ were low and high, respectively, except for capsaicinoid content. The results indicate, with slight improvement, on-line quality measurement of red pepper powder with NIRS could be applied in red pepper milling factories.

초음파 조영제를 애용한 Echo PIV 기법의 개발 (Development of Echo PIV Using Ultrasound Contrast Agent)

  • 김형범
    • 대한기계학회논문집B
    • /
    • 제28권12호
    • /
    • pp.1528-1534
    • /
    • 2004
  • The combination of ultrasound echo images with digital particle image velocimetry (DPIV) methods has resulted in a two-dimensional, two-component velocity field measurement technique appropriate for opaque flow conditions including blood flow in clinical applications. Advanced PIV processing algorithms including an iterative scheme and window offsetting were used to increase spatial resolution. The optimum concentration of the ultrasound contrast agent used for seeding was explored. Velocity validation tests in fully developed laminar pipe flow result of echo PIV showed good agreement with both optical PIV measurements and the known analytic solution based on a volume flow measurement.

이미지프로세싱 기법을 이용한 액적크기 측정 (Droplet size measurement using image processing method)

  • 임병직;정기훈;길태옥;윤영빈
    • 한국가시화정보학회지
    • /
    • 제2권1호
    • /
    • pp.25-31
    • /
    • 2004
  • Droplet size is one of the most important parameter which controls the performance of the combustion system using liquid fuel or oxidizer. Droplet formation and its size are mainly affected by the injection velocity and ambient gas density. Recently, droplet size measurement was conducted by PDPA or Malvern particle analyzer using laser light. But at this paper image processing method was developed to measure droplet size. And its validation was investigated with reticle.

  • PDF