• Title/Summary/Keyword: Measurement Validation

Search Result 705, Processing Time 0.028 seconds

Measurement and Frequency Weighting Functions for Human Vibration

  • Kee, Dohyung;Park, Hee Sok
    • Journal of the Ergonomics Society of Korea
    • /
    • v.32 no.4
    • /
    • pp.309-319
    • /
    • 2013
  • Objective: The aim of this study is to review and summarize human vibration measurement process, and necessity and methods of frequency weightings for human vibration. Background: Prolonged human exposure to hand-arm vibration and whole-body vibration can result in a range of adverse conditions and the development of occupational diseases such as vibration white finger. For preventing these adverse effects, it is important to correctly apply human vibration measurement process. Method: This manuscript was based on the review and summary of mechanical and human vibration relevant texts, academic papers, materials obtained through web surfing. Results: This manuscript summarizes human vibration measurement process described in ISO standards and relevant texts. The sensitivity of the human body to mechanical vibration is known to be dependent on both the frequency and direction of vibration. To take this into account, varying frequency weighting functions have been developed, and RMS frequency-weighted accelerations are used as the most important quantity to evaluate the effects of vibration on health. ISO provided nine frequency weighting functions in the form of curves and tables. Researches on frequency weightings are focused on development and validation of new frequency weightings to truly reflect the relationship between vibration exposure and its adverse effects. Application: This would be useful information for systematically applying human vibration measurement and analysis process, and for selecting appropriate frequency weighting functions.

Comparative Study on Similarity Measurement Methods in CBR Cost Estimation

  • Ahn, Joseph;Park, Moonseo;Lee, Hyun-Soo;Ahn, Sung Jin;Ji, Sae-Hyun;Kim, Sooyoung;Song, Kwonsik;Lee, Jeong Hoon
    • International conference on construction engineering and project management
    • /
    • 2015.10a
    • /
    • pp.597-598
    • /
    • 2015
  • In order to improve the reliability of cost estimation results using CBR, there has been a continuous issue on similarity measurement to accurately compute the distance among attributes and cases to retrieve the most similar singular or plural cases. However, these existing similarity measures have limitations in taking the covariance among attributes into consideration and reflecting the effects of covariance in computation of distances among attributes. To deal with this challenging issue, this research examines the weighted Mahalanobis distance based similarity measure applied to CBR cost estimation and carries out the comparative study on the existing distance measurement methods of CBR. To validate the suggest CBR cost model, leave-one-out cross validation (LOOCV) using two different sets of simulation data are carried out. Consequently, this research is expected to provide an analysis of covariance effects in similarity measurement and a basis for further research on the fundamentals of case retrieval.

  • PDF

Study on Antioxidant Activity and Standardization of FDY003 (FDY003의 항산화활성 및 표준화 연구)

  • Lee, Dae-yeon;Kim, Wan-su;Lee, Ho-sung;Yi, Young-woo;Jo, Ju-hwi;Lee, In-hee
    • The Journal of Internal Korean Medicine
    • /
    • v.40 no.6
    • /
    • pp.1112-1121
    • /
    • 2019
  • Objectives: FDY003 is a raw material for medicine consisting of a natural product that is expected to have the advantages of low side effects and high efficacy. In this study, we predict the efficacy and the standardization of the drug by method validation of anticipated index compounds and the measurement of antioxidant activity. Methods: FDY003 is prepared by extracting and purifying 70% of ethyl alcohol (EtOH). The method validation of cordycepin and chlorogenic acid was determined by high-performance liquid chromatography-photo diode array (HPLC-PDA) and the content of FDY003 was calculated. In order to monitor the biological activity of FDY003, antioxidant activity was measured by 1,1-diphenyl-2-picrylhydrazyl (DPPH), 2,2-azino bis (3-ethylbenzothiazoline-6-sulfonic acid) (ABTS), and ferric-reducing antioxidant power (FRAP). The equivalent values of antioxidants such as trolox, ascorbic acid, gallic acid, and caffeic acid were measured by ABTS and FRAP. Results: Chlorogenic acid and cordycepin were both found suitable for method validation in HPLC and FDY003 containing 9.92±0.50 and 17.97±0.27 ㎍/g, respectively. In DPPH, the electron donating ability (EDA) value of FDY003 was increased in a concentration dependent manner. FDY003 confirmed antioxidant activity by ABTS and FRAP. Conclusions: FDY003 contains certain components including cordycepin and chlorogenic acid and has antioxidant ability by various mechanisms. Therefore, it is expected that FDY003 is capable of various physiological activities including anti-cancer activity.

Comparison on Nano-particle Number Measurement Characteristics for Different Particle Generators between Spray type and Soot Type (Spray type과 Soot type 입자발생기별 나노입자 개수농도분포 측정특성 비교)

  • Kim, M.S.;Kwon, J.W.;Chung, M.C.;Lee, J.W.
    • Journal of ILASS-Korea
    • /
    • v.17 no.4
    • /
    • pp.185-191
    • /
    • 2012
  • Particulate matters (PM) that is generated by most diesel engine is regulated by the mass concentration measured by the conventional method it had been. Recently, Europe PMP (Particle Measurement Program) decided to start the regulation of vehicle's nano-sized particle number (PN) from the year of 2011 because of nano-particle's higher degree of harm to the human body. So firstly, the standard level of PN emission is introduced in the Euro 5/6 emissions regulation with a limit of $6{\times}10^{11}$ per km for light duty vehicle. Also KPMP(Korea Particle Measurement Program) was organized to copy quickly international technical trend. In this paper, it was investigated the nano-sized PN measurement characteristics for different particle generators between spray type and soot type. And the difference ratio between particle generators, the characteristic of PN concentration, counting efficiency and linearity was analyzed. Then, we make conclusions as followed. When particle diameter is increased, counting efficiency of two generators is decreased. Also Secondary calibration method is more higher 3% than Primary calibration method. Finally, SOF which is included in soot particles is not totally removed so it have great influence on test result of counting efficiency and linearity.

Non-intrusive measurement of pulse arrival time and Estimation of Systolic Blood Pressure (무구속적 맥파 전달 시간의 측정을 통한 혈압 추정)

  • Chee, Young-Joon;Park, Kwang-Suk
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.489-492
    • /
    • 2005
  • Even though the blood pressure is one of the most widely used index for the healthcare monitoring of hypertensive and normotensive persons, there is no non-intrusive measurement method which is commercialized until now. Pulse Arrival Time (PAT) is known that it has close relation with the systolic blood pressure (SBP) and arterial stiffness. In this study, SBP estimation methods by non-intrusive measurement of PAT are suggested. For the unconstrained measurement of PAT, the first method used the electrically non contact electrocardiogram (ENC-ECG) technique and the reflective type of Photoplethysmography (PPG) sensor on the computer mouse. In the second method, ENC-ECG and the air pressure sensor in the seat cushion on a chair were measured. The third method used ECG electrodes and PPG sensors on the toilet seat cover. The validation and regression analysis of the relationship of PAT and SBP are summarized. These methods have considerable errors to be used for all people. But these can be applied for each subject after the parameter customization within acceptable error. So, it is feasible for suggested methods to be used for monitoring of SBP in daily life in non-intrusive way when there is personal identification system of each subject.

  • PDF

Specifying and Analyzing Formative Measurement of High-order Factor (고차 요인의 형성적 측정방법에 대한 식별 및 분석방법)

  • Yim, Myung-Seong
    • Journal of Digital Convergence
    • /
    • v.11 no.3
    • /
    • pp.101-113
    • /
    • 2013
  • Although the methodological literature is replete with advice regarding the development and validation of multi-item scales based on reflective measures, the issue of index construction using formative measures has received little attention. The aim of this paper is to enhance researchers' understanding of formative measures of high-order factor and assist them in their index construction efforts. This article is also to provide some insights into the nature of formative indicators for researchers to reach an informed choice as to the appropriate high order formative measurement model for their needs. We first provide a brief background on formative indicators, drawing from the limited and fragmented literature on the topic. Next we give an example of constructing an index based on actual survey data and highlight the procedures used to assess its quality. We conclude the article with some thoughts about the use of indexes in empirical studies.

Laser based impedance measurement for pipe corrosion and bolt-loosening detection

  • Yang, Jinyeol;Liu, Peipei;Yang, Suyoung;Lee, Hyeonseok;Sohn, Hoon
    • Smart Structures and Systems
    • /
    • v.15 no.1
    • /
    • pp.41-55
    • /
    • 2015
  • This study proposes a laser based impedance measurement system and impedance based pipe corrosion and bolt-loosening monitoring techniques under temperature variations. For impedance measurement, the laser based impedance measurement system is optimized and adopted in this paper. First, a modulated laser beam is radiated to a photodiode, converting the laser beam into an electric signal. Then, the electric signal is applied to a MFC transducer attached on a target structure for ultrasonic excitation. The corresponding impedance signals are measured, re-converted into a laser beam, and radiated back to the other photodiode located in a data interrogator. The transmitted impedance signals are treated with an outlier analysis using generalized extreme value (GEV) statistics to reliably signal off structural damage. Validation of the proposed technique is carried out to detect corrosion and bolt-loosening in lab-scale carbon steel elbow pipes under varying temperatures. It has been demonstrated that the proposed technique has a potential to be used for structural health monitoring (SHM) of pipe structures.

Development and Validation of the Hospital's CSR Measurement Tool (의료기관 사회적 책임활동 측정 도구개발 및 타당화)

  • Cho, Kyoung Won;Sagong, Mi;Cho, Minje
    • The Korean Journal of Health Service Management
    • /
    • v.12 no.2
    • /
    • pp.149-162
    • /
    • 2018
  • Objectives : This study aimed to develop tools to measure the social responsibility activities of hospitals using ISO 26000 and to verify the validity and reliability of the developed tools. We verified the content and structural validity, as well as the internal consistency of the proposed measurement tool for hospitals' social responsibility. Methods : We conducted an online survey on hospitals/employees from Feb 26 to Mar 12, 2018, and analyzed selected 197 respondents from the survey by removing incomplete responses. Results : The developed hospitals' CSR (HSR) measurement tool consists of 36 items with 5 factors: "consumer issues", "labor practices", "community involvement & development", "fair operating practice", and "environment". Analysis revealed high reliability with Cronbach' alpha of 0.981. Conclusions : It was verified that the developed HSR tool fully reflected hospital characteristics. This tool can be used to diagnose hospitals' social responsibility and to support strategic decision on social responsibility.

Conceptualizing 5G's of Green Marketing for Retail Consumers and Validating the Measurement Model Through a Pilot Study

  • ANSARI, Hafiz Waqas Ahmed;FAUZI, Waida Irani Mohd;SALIMON, Maruf Gbadebo
    • Journal of Distribution Science
    • /
    • v.20 no.4
    • /
    • pp.33-50
    • /
    • 2022
  • Purpose: This pilot study aims to conceptualize a new green marketing mix for retail consumers based on Stimulus-Organism-Response (SOR) model. Moreover, it also aims to conceptualize a testable research model of new green marketing mix with consumers' green purchasing behavior, and to validate the measurement model with traditional as well as modern suggested validating techniques. Research design, data and methodology: A pilot test data from 75 respondents of retail buyers of energy-efficient electric appliances in Pakistan were tested for the confirmatory factor analysis (CFA) by examining a measurement model of the construct through different validation techniques (like Composite Reliability, McDonald's Omega (ω), rho (ρA), HTMT, etc.) as heretofore these scales were not validated through these modern methods. Results: The results revealed that the instrument has a certain degree of reliability and validity through different validating techniques. All the measurement items reach the suggested threshold values. Conclusions: Therefore, this study conceptualized an integrated framework of all the three stakeholders of the environment (government, companies, and public or consumers) to achieve environmental sustainability. Hence, future studies can extend these findings and conduct a full-scale study to establish an empirical relationship between the 5G's of green marketing for retailing businesses and consumers' green purchase behavior.

Assay Validation of Lansoprazole in Human Plasma

  • Lim, Yoon-Young;Woo, Jong-Soo;Kim, Chong-Kook
    • Proceedings of the PSK Conference
    • /
    • 2002.10a
    • /
    • pp.395.3-396
    • /
    • 2002
  • A simple, rapid and reliable high performance liquid chromatography (HPLC) method has been developed for the measurement of lansoprazole in human plasma, and the application of pharmacokinetic study has been evaluated. Omeprazole was used as an internal standard. After adding methyl tert-butyl ether, samples were stored at -7$0^{\circ}C$. The extracts were easily obtained only with pouring the organic phase. The mobile phase was prepared using acetonitrile and water at the volume ratio of 38:62. (omitted)

  • PDF